MTS AND MTS PR¼ 16 OUTPUT SEQUENTIAL TIMER PENTAIR CLEAN AIR SYSTEMS

Similar documents
Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Digital flow ELEMENT transmitter for continuous flow measurement

Liquid ring vacuum pumps in compact design

IP26 Series Current to Pneumatic Converter

ph or ORP Transmitter

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

ICARUS ELECTRONIC GAS VOLUME CONVERTER

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

FITTINGS. Pneufit C composite and Pneufit M fittings Metric Ø 3 to 16 mm O/D tube

PAD - Heavy Duty Differential Pressure Trasmitter

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Electronically controlled proportional pressure regulating valves

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

vacon nx installation manual ac drives fr7 ip54 kit

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

82880 series 2/2-way motorised valves

Heavy duty pressure controls Type MBC 5000 and MBC 5100

INLINE flowmeter for continuous flow measurement

Technical Information Nivector FTC968, FTC968Z

Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output

Conductivity Transmitter

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

ED701 General Industry Pressure Transmitter

TX-1AA TRANSMITTER. Note:

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

SINGLE SHUT OFF QUICK RELEASE COUPLINGS

Base Mounted Plug-in Unit

Air Hose Products.

Ex-control switch Typ 294 without and Typ 295 with measuring instrument

MODEL: DAST-20. Telemetering System

NRT 105: Electronic fan-coil controller, equiflex

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

MODEL: MRP6. Final Control Elements

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

INSERTION paddle wheel flowmeter for continuous flow measurement

FLOWave SAW-Flowmeter

SONOMETER TM 1100 Ultrasonic compact energy meter

Product Launch Package. Refrigeration Marketing Units Emerson Climate Technologies Europe

SALES SERVICE +358 (0)

Ultrasonic level transmitter, non-contact

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MBC /602(L) MBC /602(L) MBC /602(L)

CARTRIDGE-STYLE RECOVERY POWDER BOOTH

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Pressure transmitter AKS 32 and AKS 33

2/2 way Proportional Valve (motordriven)

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Positive Displacement Flow sensors

TIDALFLUX 2300 F Technical Datasheet

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

SOLENOIDS, COILS & ACCESSORIES Product Index

SONOMETER TM 1100 Ultrasonic compact energy meter

Characteristics curve Fluid: water p: 1 bar. Weight. Sectional diagram. no. [kg]

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

FLOWPET-NX (Oil Service Mechanical Register)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Digital flowmeter for continuous flow measurement

DONGAN ELECTRIC MANUFACTURING CO.

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

SATRON VB Pressure Transmitter

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Room Temperature Controllers. for heating and cooling systems

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

OPTIFLUX 5000 Technical Datasheet

PROPORTIONAL PRESSURE CONTROLS TECNORD

/2 way motorised valves

B34 Series Regulator Commercial and Industrial Regulator

COFFEE LABORATORY WHITE STONE VA TEL

Sicherheit, auf die Sie sich verlassen können

PRESSURE REGULATORS PARKER PRESSURE REGULATING VALVES PRESSURE REGULATORS

Flowmetering System Controller KMA4000 / PLU4000 Operating instructions

WATERFLUX 3000 Quick Start

Electro Controls. Input-Output Modules WattsIndustries.co.uk

A6500-UM Universal Measurement Card

4/3 Proportional Directional Valve, Size SAE 10

with Electronic Assistant

Preset counters, electronic

Target disk flowmeter for liquids and gases

C O M F O R T F O R L A R G E S P A C E S. R a d i a n t h e a t i n g

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Insertion Flow sensor for continuous flow measurement

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

Electronic Heating Energy Meters

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Standard valves to ISO Product range overview

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Positioner with HART Communication Type 3780

Transcription:

MTS AND MTS PR¼ 16 OUTPUT PENTAIR CLEAN AIR SYSTEMS

MTS DESCRIPTION The Model MTS sequencer has been designed to guarantee the control of diaphragm valves mounted on pulse-jet dust collector filters containing filter bags or cartridges. All the technical characteristics comply with the CE Directive. The MTS conforms to the European norm (89/336 EEC and 93/68 EEC). Upon request it is possible to supply the unit in accordance with the European Directive EC/94/9 ATEX, ATEX II 3D (zone 22). The MTS sequencer is available in the following versions: MTS4, MTS8, MTS12, MTS16. The MTS Sequencer allows you to set and visualise via the display: Number of valves Pulse time Pause time Number of shut-down cleaning cycles When in shut-down cleaning mode, the pause time is the same as that set in normal operation. MAIN FEATURES Ability to regulate pulse time and pause time via a digital display Remote contact Shut-down cleaning with number of cycles easily set Selection of inlet and outlet voltages (AC/DC) DIMENSIONS MTS 4 16 (mm) 03

MTS TECHNICAL CHARACTERISTICS Power inlet Number of outlets Power absorption Pulse time Pause time Remote control Shut-down cleaning Standard: 115/230 V AC (±10%), 50/60 Hz (Selectable via jumpers) Minimum 2 to Maximum 16 outlets Without outlet: 2.5 VA. Outlet: 25 VA 20 W 0.01 9.99 sec. 1 999 sec. Activated via external contact (normally open) free of power. Optional: 24/48 V AC (±10%), 50/60 Hz 1 99 cycles. To be operated from the normally closed contact of fan remote control switch. Main fuse 500 ma delayed 115/230 V 2 A delayed 24/48 V Connections Push-in terminal blocks max. section 2.5 mm 2 Protection rating IP65 Temperature Storage: 20 C/+80 C Working temp: 10 C/+50 C, with duty cycle (intermittent) 30% Dimensions Weight Enclosure MTS 4-8-12-16 out: Box 213 185 113 mm Approx. 2 kg (all models) ABS grey transparent cover * NB: for voltages 115 V AC and 230 V AC the inlet and outlet voltage has to be the same. 04

MTS PR¼ DESCRIPTION The Model MTS PR¼ -24/DC sequencer is an integrated model which incorporates the remote pilot valves, model PR¼, which can be pneumatically connected to the diaphragm valves type VEM rather than with electrical connections. This version has been designed to guarantee the control of diaphragm valves mounted on pulse-jet dust collector filters containing filter bags or cartridges. All the technical characteristics comply with the CE Directive. The MTS-PR¼ conforms to the European Directive (89/336 EEC and 93/68 EEC). Upon request it is possible to supply the unit in accordance with the European Directive EC/94/9 ATEX, ATEX II 3D (zone 22). The pilots are mounted within the enclosure, are pre-wired and have a ¼ Gas female thread to be used for the pneumatic connections between the remote pilot and the diaphragm valve. The MTSPR¼ is available from a minimum of 2 pilot valves to a maximum of 16 pilot valves mounted within the enclosure. MAIN FEATURES Remote pilot valves (brass) pre-wired in enclosure complete with electronic sequencer Ability to regulate pulse time and pause time via a digital display Remote contact Shut-down cleaning with number of cycles easily set Selection of inlet and outlet voltages (AC/DC) GENERAL CHARACTERISTICS Fluid Air inlet Operating pressure Exhaust Air dry and oil free ¼ Gas From 0.5 to 7.5 bar 1 8 Gas CONSTRUCTION CHARACTERISTICS Pilot body Pilot Locknut O-ring Brass Brass Zinc plated NBR 05

MTS PR¼ DIMENSIONS SEQUENCER MTS2 4 - PR¼ SEQUENCER MTS6 12 - PR¼ TECHNICAL CHARACTERISTICS Power inlet Number of outlets Power absorption Pulse time Pause time Remote control Shut-down cleaning Standard: 115/230 V AC (±10%), 50/60 Hz (Selectable via jumpers) Minimum 2 to maximum 16 outlets Without outlet: 2.5 VA. Outlet: 25 VA 20 W 0.01 9.99 sec. 1 999 sec. Activated via external contact (normally open) free of power. Optional: 24/48 V AC (±10%), 50/60 Hz 1 99 cycles. To be operated from the normally closed contact of fan remote control switch. Main fuse 500 ma delayed 115/230 V 2 A delayed 24/48 V Connections Push-in terminal blocks section max. 2.5 mm 2 Protection rating IP65 Temperature Storage: 20 C/+80 C Working temp: 10 C/+50 C, with duty cycle (intermittent) 30% 06

Mecair 16 Output Sequential Timer EU Compliant Rev02 02/15