For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Similar documents
TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

Installation Instructions

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

1530(F) Mortise Exit Devices Installation Instructions

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

7130(F) Series Mortise Exit Devices Installation Instructions

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

INSTALLATION INSTRUCTIONS CRL JACKSON

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CRL JACKSON

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

Installation Instructions

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

ED5200(A) Series Rim Exit Devices

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

Entry Mortise Handleset

WD WD7000 Series

MORTISE LOCK INSTALLATION INSTRUCTIONS

1510(F) Surface Vertical Rod Exit Devices Installation Instructions

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

Privacy Wall Glass Selections - Polished Edge Slider Door

BEFORE STARTING INSTALLATION

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Assembly Instructions 10 X 10 Aluminum Frame Building

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

CONCEALED ROD CRASH BAR PR-7085 SERIES EXIT DEVICE ASSEMBLY DETAILS PR mm. 10mm. Lock cylinder. 10mm. Cross bar length (see note #8) Dogging

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

BioPrism Solid Surface

Installation Instructions

Installation Instructions for 45H & 47H Mortise Locks

Entry Mortise Lock Set Lever to Lever

Oxford Stalls Installation Instructions

1500(F) Rim Exit Devices Installation Instructions

Installation Instructions For Profile Series v.g1 Exit Device

ICU TRACKLESS SLIDING DOOR

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Shetland Stalls Installation Instructions

INSTALLATION INSTRUCTIONS

Chapter 9. Windows and Exterior Doors

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Wood Doors. Wood Doors ASSA ABLOY.

7210 Surface Vertical Rod Exit Device Installation Instructions. Outside Trim

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Hollow Metal & Aluminum Doors

Installing Your Electronic Deadbolt

Installation Instructions

Installation Instructions For The 8850FL Series Mortise eboss

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

Installation Instructions. Installation Type

Chapter 9. Windows and Exterior Doors

Passage Mortise Lock Set Lever to Lever

Installation Instructions. Installation Type

Important: Read this first!

Motorized or Crank Operated Fortress Zipper Track Shade with Housing and Side Track Installation Instructions

101B, 210X, ELM, VSTB Installation Manual

INSTALLATION INSTRUCTIONS

Atrium Patio Door Field Service Manual

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

Tools Required. * When installing on a fire door, please see instructions below. *

2300 BI-FOLD INSTALLATION GUIDE

Senior Swing. Caution

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

TH955 & TH959. Heavy Duty Thumbpiece Trim For use with ED5000 Series Exit Device. Metal, Wood or Composite Doors

Victory Fire Door Inspections

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

Sliding Glass Door Assembly and Installation Guide

IMPORTANT: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE

C-Series & S-Series Classic Frame with Transom (Single or Pair)

SIDE FOLDING POST ADJUSTMENTS

Please read and understand all instructions before beginning. These instructions cover impact and non-impact aluminum French Door 650/750.

CL4500 Installation Instructions

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL

ICU TRACK SLIDING DOOR

Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

KIT. Assembly Instructions. HayDay, LLC

INSTALLATION INSTRUCTIONS

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

Installation Instructions

DC3210. Recommended Closer Size

Assembly Instructions

VACUSEAL MODEL 200. HOT TUB PRODUCTS 233 Carrington Road Bethany CT

INSTALLATION INSTRUCTIONS

READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION

Installation Instructions

Finish Hardware. Contents. Section 10

Installation Instructions For Profile Series v.g1 Cylindrical Lock

Transcription:

SARGENT Installation Instructions for LP8600 x LR8600 & 12-LP8600 x 12-LR8600 Series Low Profile Panic and Fire Exit Devices on Double Egress & Double Doors or LS8600 & 12-LS8600 Low Profile Exit Device on Single Door For installation assistance, contact SARGENT at 800-727-5477 www.sargentlock.com Patent pending and/or patent www.assaabloydss.com/patents DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY. 12-LR8600 19-LP8600 Lock down key To operate: Depress pushrail Insert hex key and turn NOTES: 1) The doors should be properly reinforced and should be fully prepared by the door manufacturer. 2) Rails can not be cut down in the field. APPLICATION ILLUSTRATION OUT Right hand Double Doors Double Egress CAUTION, BEFORE STARTING: Check hand of door LP8600 & LR8600 exit devices are non handed, ET trim is field reversible. LS86000 curved lip strike is handed. 2-3/4" backset only 1-3/4" thick doors only Verify box label for size, function and hand of exit device Available lengths: Length L for 36" wide doors Length M for 42" & 44" wide doors Length N for 46" & 48" wide doors Door should be fitted and hung unless low ceiling condition exists (For low ceiling conditions, install mortise lock and top rod before hanging door. Low ceiling exists if ceiling height is less than: (2 x door height) mounting height i.e. 7' door with device mounted at 41" aff would need (2 x 7') 41" or 10'7" ceiling.) Doors that are hung should be square and plumb. Clearance between the doors should be per the door manufacturers specification; i.e. gap between doors should be 1/4" at center line of bevels. (If gap is over 1/4" doors must be shimmed to decrease the gap.) SINGLE DOOR 1

REQUIRED TOOLS: Hammer Drill with 11/32" drill bit Needle nose pliers Locking pliers #2 Phillips screw driver Flash light #3 Phillips screw driver Tape measure A INSTALL MORTISE LOCKS B INSTALL TRIM (IF APPLICABLE) 1) Using the appropriate portion of template A6381, supplied with trim, drill all required holes in the door. 2) Align the spindle with the outside hub and install ET trim. 3) Secure with 1/4-20 screws and cup washers. 1) Mount primary and secondary mortise locks in doors with (2) #12 flat head machine screws provided. 2) Install outside fronts to mortise locks with (2) #8 flat head machine screws provided. Secondary mortise lock Primary mortise lock Outside hub Cup washer D INSTALL TOP ROD ASSEMBLY C ASSEMBLE TOP ROD AND EXTENSION 1) If rod assembly is in two pieces, continue with step 2. If rod assembly is in one piece go, to part D. 2) Slide rod together and align holes. 3) Secure with spiral pin. 1) Insert rod assembly into door, as shown. 2) Align connecting tube with top mount. 3) Rotate rod assembly clockwise until projects 1/4 above the door. Connecting tube Extension rod and mount Connector Spiral pin Latch tail rod Connecting tube NOTE: After rods are installed, doors can be blocked open until chassis is installed. If doors are closed and latched before chassis is installed, the s can be retracted from the inside by pulling the latch tail toward the hinge. 2

E INSTALL TOP CASE AND STRIKE F INSTALL CHASSIS IN RAIL case button case 1) Slide top case over top until threaded holes line up with 2 C-Sunk holes at the top of the door. 2) Using (2) #10-24 x 3/8" oval head screws fasten top case in place. 3) Mount top strike to frame using (2) #10-24 flat head screws provided. 1) Depress lift arm and slide chassis into rail as shown. NOTE: Ensure notch at the top of the door is large enough, so that there is no interference or bind with the top case button. Frame header section 2) Align tapped holes in chassis to C-Sunk holes in rail. Using (2) #6-32 flat head screws, secure chassis to rail. 650 strike G INSTALL RAIL 1) Rotate link connector up and place rail assembly in door cavity as shown. 2) Align C-Sunk holes in chassis with tapped holes in door and secure with (2) #10-24 flat head screws. 3) Position mounting bracket to support end of rail and secure with (2) #10-24 pan head screws. #10-24 flat head screws #10-24 pan head screws connector Mounting bracket 3

H CONNECT LINKAGE I ADJUST SECONDARY MORTISE LOCK (LR8600) 1) Rotate link connector down and pull toward mortise lock. 2) Align one pair of holes on link connector with mortise tail and secure using (2) #8 truss head screws. REPEAT FROM PART B ON OPPOSITE DOOR. connector 1) Depress rail and observe center. If is projected, flush or just beyond outside front, adjustment is correct. 2) If adjustment is required, remove (2) #8 screws from linkage. 3) Rotate lever trim to align next set of holes. 4) Reinstall the #8 screws and repeat step 1. connector Mortise tail J Mortise tail ADJUST PRIMARY MORTISE LOCK (LP8600) 1) With both doors closed, check for proper top and center latch throw and engagement with strikes. 2) Depress push rail to retract latches and open door. If center does not retract to clear the LR8600 outside front, adjustment is required. 3) Remove (2) #8 screws from linkage. 4) Rotate lever trim to align next set of holes. 5) Reinstall the #8 screws. 6) Repeat step 1 to verify adjustment. Activation Center LR8600 outside front 5) If binding condition occurs where top remains retracted and center remains extended when door closes, remove the (2) #8 screws installed in part H. 6) Install link spacer between the link connector and mortise tail, reinstall #8 screws. Then repeat step 1. spacer Latch 7) If binding condition occurs where top remains retracted and center remains retracted when door closes, remove the (2) #8 screws installed in part H. 8) Install link spacer between the link connector and mortise tail. Reinstall #8 screws. Then repeat step 1. spacer 4

K CENTER BOLT ADJUSTMENT L TOP BOLT ADJUSTMENT 1) If there is not enough center latch projection and engagement into the other door, the center can be adjusted. 2) Open door and depress the activation to project the latch. 3) Using locking pliers, grip the latch near the lock front. 4) Insert a 5/32" allen wrench into the latch. Pull the latch out until you can freely turn the adjusting screw. 5) To increase projection, turn the adjusting screw counterclockwise. To decrease projection, turn the adjusting screw clockwise. When desired projection is achieved, rotate the adjusting, screw so the flats are aligned with the 2 press fit pins. 6) Release the pliers and allow the latch to snap back. Activation 1) If there is not enough top latch engagement into top strike to latch the door securely, complete the following steps: 2) Remove top case from door and rotate the top counterclockwise to increase projection. 3) Reinstall top case, and recheck the adjustment. case Press fit pin Adjustment screw Center latch M OPERATION VERIFICATION 1) Open and close doors several times in different sequences to ensure proper operation and latch engagement into strikes. Center latch should project into opposing door regardless of closing order. 2) If s are not retracting or projecting properly, review/repeat parts I thru L. N INSTALL COVERS 1) Verify that all adjustments have been made and all mounting screws are tight. 2) Install front cover and end cap, secure with (2) #8 cover screws on each. End cap Front cover 5

REQUIRED SCREWS (2) #8-32 (Lock fronts) (2) #10-24 Pan head (Mounting bracket to door) (4) #8-32 #8 Under-cut oval (Covers) (2) #6-32 (Chassis to rail) (2) #12-24 (Mortise lock to door) (4) #10-24 (2 Chassis to door) (2 Strike to frame) (2) Cup washer (Trim mounting) (2) #10-24 Under-cut oval ( case to door) (2) #8-32 Truss head ( connector to mortise tail) (2) 1/4-20 Flat head (Trim mounting) SCREW PACKS AND MISCELLANEOUS PARTS 68-1317 Front cover (Finished) 68-1316 End cap (Finished) 01-0696 Spiral pin 68-1186 Primary outside front 68-1183 Secondary outside front 77-0883 Curved lip strike () 77-0884 Curved lip strike (Right hand) 650 strike pack 77-4236 Screw pack (Mortise lock) 68-4373 Screw pack (Chassis) 68-3677 Screw pack ( case) 68-4383 Screw pack (Mounting plate) 651 Kit Lexan touch pad 816 Cylinder dogging kit FOR ADDITIONAL INFORMATION CONTACT SARGENT AT 1.800.727.5477 6