MTP-NT INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

MTP-NT. Preliminary version Sophisticated multi-channel telemetry system for rotating application, fully software programmable with 16 bit resolution

KMT - Kraus Messtechnik GmbH

User Manual MTP Multi-channel telemetry system for rotating application, full software programmable with 16 bit resolution

KMT - Kraus Messtechnik GmbH

Telemetrie-Messtechnik Schnorrenberg

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive

KMT - Kraus Messtechnik GmbH

400 (±2,5 V/ V/ ,3% V4A

KMT - Kraus Messtechnik GmbH

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Order/Technical Support Tel: (800) / FAX: (800) /

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

DETECTING SHORTED TURNS

G3EJS 2-Tuner. Having recently bought an FT-817, and immediately missing the internal tuner my IC-703 has, I started looking for an answer.

HTC Technical Manual

Induction heating of internal

Iron Powder Core Selection For RF Power Applications. Jim Cox Micrometals, Inc. Anaheim, CA

Assembly Instructions: Kit #5

VR20 - Inductive sensor (LVDT) Measurement range from 25 to 600 mm

COMPLIANT Common Mode Chokes - UU9.8 & UU10.5 Series

EMC Near-field Probes + Wideband Amplifier

Table of Contents. Table of Figures. Table of Tables

Exercises of resistors 1. Calculate the resistance of a 10 m long Copper wire with diameter d = 1.0 mm.

SoftRock v6.0 Builder s Notes. May 22, 2006

KMT - Kraus Messtechnik GmbH

RFID. Technical Training. Low Frequency Antenna Design. J.A.G Jan 2009 Texas Instruments Proprietary Information 1

Telemetrie-Messtechnik Schnorrenberg

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

INTER PLANT STANDARD STEEL INDUSTRY

Generator Power [kw]

Topic 4 Practical Magnetic Design: Inductors and Coupled Inductors

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Inductive Proximity Detectors Technical Guide

User Manual CTP4/8/16

Encoder - Absolut 2RMHF-SSI

Pacific Antenna 20 and 40M Lightweight Dipole Kit

Pacific Antenna 20 and 40M Lightweight Dipole Kit

Pacific Antenna 20 and 40M Lightweight Dipole Kit

Telemetrie-Messtechnik Schnorrenberg

Inductors & Resonance

Target Temperature Effect on Eddy-Current Displacement Sensing

Ileana-Diana Nicolae ICMET CRAIOVA UNIVERSITY OF CRAIOVA MAIN BUILDING FACULTY OF ELECTROTECHNICS

A short, off-center fed dipole for 40 m and 20 m by Daniel Marks, KW4TI

SoftRock v6.0 Builder s Notes. April 6, 2006

Dx: Digital Multi-Channel Telemetry System

Technical data. General specifications. Measurement range min max. 360

DESIGN AND TECHNOLOGY OF THE MAINS SINGLE PHASE, LOW POWER TRANSFORMER

NCS3 Series Isolated 3W 4:1 Input Single Output DC-DC Converters

LANGER EMV-TECHNIK. Operating Instructions. A 100 / A 200 / A 300 Optical Fibre Probe

LC31L-BAT Link Coupler

INDEX PREFACE... 1 CAUTIONS... 2 OPERATION ON SITE(9) STANDARD INSTRUMENT... 3 OPTIONAL ACCESSORIES... 4 OPERATION OF TRANSMITTER(3)...

MAGNETIC LOOP SYSTEMS SIMPLIFIED

AC/DC POWER SUPPLY KIT

AP Physics C. Alternating Current. Chapter Problems. Sources of Alternating EMF

ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment)

LENORD GEL BAUER

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

PKG-341-MLA-CBL System Diagram and Specifications

Low Frequency Velocity Sensor

CELES MP Flexible - Compact - High Efficiency. Induction Heating - Power from 2 to 12 kw - Frequency from 20 khz to 2 MHz.

TRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

EMC filters. Mounting instructions. Date: January 2006

ATUs - ANTENNA TUNING UNITS THE ATU. An Antenna Tuning Unit MAKE YOUR OWN ATU

14 : TRANSDUCERS I. INTRODUCTION II. FARADAY S LAW OF ELECTROMAGNETIC INDUCTION A. A SINGLE WIRE MOVING IN A MAGNETIC FIELD

AXON J1DB. digital 1-channel telemetry for strain gauge measurement with additional monitoring of inductive energy on the rotor unit

Line Frequency Transformer

Iron Powder Cores for High Q Inductors By: Jim Cox - Micrometals, Inc.

Some hints/tips on how to assemble nice COAX TRAPS!

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders 18 bit ST / 12 bit MT

nical catalogue Tech

Properties of Inductor and Applications

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

The electronic anti-scale system

Electromagnetic Compatibility

How should one design a 50kHz, 1200VA transformer as per IEC 61558?

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

SOME STUDIES ON HIGH FREQUENCY RESONANT INVERTER BASED INDUCTION HEATER AND THE CORRESPONDING CHOICE OF SECONDARY METALLIC OBJECTS

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

EFFICIENCY APPLICATION NOTES. Power Purifier - IPP#15. General. Why is it Important to Consider Efficiency?

SONO 1500 CT Ultrasonic flow sensor

AC/DC Resistance Standard DRR-112

Transformers. Objectives

Leakage Flux Recovery Coil for Energy Harvesting Using Magnetoplated Wire

Use optocouplers for safe and reliable electrical systems

A Transmatch for Balanced or Unbalanced Lines

AUR.EL RTX-MID-868-OOK DESCRIPTION. MECHANICAL DIMENSIONS and PIN-OUT. Absolute maximum values

Chapter Moving Charges and Magnetism

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

CONTENTS 2/ /7 8/9 10/11 12/13 14/15 16/17 18/19 20/21 22/23 24/25 26/27 28/29 30/31 32/ Contact Us 38

Lesson 11: Antennas. Copyright Winters Version 1.0. Preparation for Amateur Radio Technician Class Exam

QUINT-PS/ 3AC/24DC/10

SELECTION GUIDE. Nominal Input Voltage Output Voltage. Output Current

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

Transcription:

Telemetrie-Messtechnik Schnorrenberg MTP-IND-PWR User Manual Inductive power supply set Power supply for power head 25 and 50mm mounting tape to fix coil on shaft Ferrite tape 30mmx3m CUL 1.00 mm (Enamelled copper wire) DC Power cable Optional AC/DC Adapter 120Watt (24V 5A) IND-PWR AC/DC module Input: AC from coil Output 6.5VDC max. 1000mA Power Head with 5m cable Picture shows standard Inductive Power Supply for diameter up to 300mm

MTP-IND-PWR - AC/DC Module for inductive power MTP-IND-PWR AC/DC Module for inductive power Input: 30-60kHz 10-60V AC Output: 6.5 DC Current: up to 1000mA Weight: 60 gram Vibration: 5g Shock: 3000g IND- PWR COIL AC IN - 30-60kHz 6.5V DC OUT Control pin assignment IND- PWR COIL AC INPUT - 30-60kHz IND- PWR 6.5V DC OUTPUT Version 2012-01 2 Technical Data are subject to change without notice!

MTP module housing - dimensions Weight about 60 grams Version 2012-01 3 Technical Data are subject to change without notice!

MTP-inductive power supply Installation of coil for inductive powering on shaft Attach for electromagnetic isolation Ferrite Tape 2x parallel and 1x in the middle over two layer around the shaft Strip the isolation from the end of the wire with a skinning tool or head up you soldering iron over 450 C to burn off the insulation from the wire! Make power coil with 3-18 windings for 1000-20mm diameter (see diagram) and twisted the end of wire. Use 0.63 1.00 mm (1.00mm for diameter of 100-1000mm) CUL wire (Enamelled copper wire) Version 2012-01 4 Technical Data are subject to change without notice!

Solder the end of the wire on the AC IN of the IND-PWR module and isolate all solder points with shrink tubing. Fixed with 3 layers mounting tape Note: The inductive load of the MTP- IND-PWR and the capacitor in the Power Head must be in resonance to get the optimal transmission. The inductive load of the shaft depends of diameters, material and number of windings! Control the output voltage and move the power-head in the max distance to the coil. The output voltage must be 6.5 V! 6.5 DC OUT max. 1500mA AC IN The pins Coil are the AC power input from the coil. On the pins +6.5 and GND you get a stabilized output voltage of 6.5V DC. The max. load current on the DC output is 1000mA. The IND-PWR converter will use instead battery pack! Never use any battery together with the MTP-IndPwr! You should mount the power head at a fixed location that it s as free as possible from vibration influences. The center of the coil should be in the same horizontal position as the center of the power head. The distance is optimal in the range between 5 and 10mm. (depends of shaft and current consumption) Version 2012-01 5 Technical Data are subject to change without notice!

Find the correct amount of windings of inductive power coil Optimum windings for steel shafts 1200 1000 Diameter mm 800 600 400 200 0 0 5 10 15 20 Windings Windings Diameters (mm) 3 1000 5 490 7 290 9 190 10 150 12 120 14 80 16 45 18 20 Distance 5-15mm Magnetic field Distance dependent of current consumption e.g. 1000mA at 5-10mm, 500mA at 10-15mm Version 2012-01 6 Technical Data are subject to change without notice!

IND-PWR-HEAD-XXL Version 2012-01 7 Technical Data are subject to change without notice!

Dimensions of IND-PWR-HEAD-XXL Version 2012-01 8 Technical Data are subject to change without notice!

MTP-IND-PWR Following must be considered at the mounting of the inductive power head Shaft with Cu wire Coil Magnetic field 25-30mm Don t use for mounting any kind metal in this area (25-30mm)! Otherwise magnetic energy will flow in the metal and decrease the distance between power head and coil (on shaft)! Example of mounting Wrong!!! Mounting (only if metal) plate cover the active area of Version 2012-01 9 Technical Data are subject to change without notice!

MTP-IND-PWR-XXL Pin connection CONTROL - Not used! DC 10-30V AC 25-35kHz output (120 WATT) for power head E= have no function Powering and AC out LED flashing = auto adjustment LED ON = finish IND-resonance of Power head reached! Control out of function Power control LED Power Switch AC 25-35kHz output for power head Power INPUT DC 10...30V Typical 24V 5V (>120WATT) Version 2012-01 10 Technical Data are subject to change without notice!

Safety notes for inductive powering The device should only applied by instructed personnel. The power head emits strong magnetic radiation at 30-60 khz to a distance of 20 cm. Therefore persons with cardiac pacemakers should not work with this device! Magnetic data storage media should be kept in a distance of at least 3m from the power head to avoid data loss. The same is valid for electromagnetic sensitive parts, devices and systems. Do not place the power head in the switched-on state on metallic objects, because this results in eddy currents which could overload the device and strong heat up small objects. Also the probe could be destroyed! No metallic objects, other than the disc-type coil, should be located in the air gap of the power head. The same applies to metallic parts within a radius of up to 30 mm in all directions. Do not use damaged or faulty cables! Never touch in the area between shaft and inductive head, the rotating shaft itself or rotor electronic contacts during operation! This is a Class A system suitable for operation in a laboratory or industrial environment. The system can cause electromagnetic interferences when used in residential areas or environments. In this case the operator is responsible for establishing protective procedures. Version 2012-01 11 Technical Data are subject to change without notice!