Testing Sync-E Wander to ITU-T G.8262

Similar documents
Tests using Paragon-X, courtesy of

INTERNATIONAL TELECOMMUNICATION UNION. Timing requirements of slave clocks suitable for use as node clocks in synchronization networks

ITU-T G /Y

Measuring Time Error. Tommy Cook, CEO.

When paired with a compliant TCXO or OCXO, the Si5328 fully meets the requirements set forth in G.8262/Y ( SyncE ), as shown in Table 1.

The all-in-one field sync tester

SERIES O: SPECIFICATIONS OF MEASURING EQUIPMENT Equipment for the measurement of digital and analogue/digital parameters

Oscillator Impact on PDV and Design of Packet Equipment Clocks. ITSF 2010 Peter Meyer

The all-in-one field sync tester

CONTRIBUTION TO T1 STANDARDS PROJECT ************************************************************************************************

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

Stratum 3 Simplified Control Timing Modules (MSTM-S3-T2NC)

Power Matters. Time Interfaces. Adam Wertheimer Applications Engineer. 03 November Microsemi Corporation.

ETSI EN V1.1.1 ( )

Stratum 3E Timing Module (STM-S3E, 3.3V)

SCG2000 Series Synchronous Clock Generators

Table MHz TCXO Sources. AVX/Kyocera KT7050B KW33T

Stratum 3 Simplified Control Timing Modules (MSTM-S3-T2-FD)

MSTM-SEC1 Simplified Control Timing Module

8800SX Series P25 Phase II Test Option 05

Raltron Electronics IEEE-1588 Products Overview

SCG4000 V3.0 Series Synchronous Clock Generators

Delay Variation Simulation Results for Transport of Time-Sensitive Traffic over Conventional Ethernet

time sync in ITU-T Q13/15: G.8271 and G

8800SX TETRA Base Station Operation

Virtex-5 FPGA GTX Transceiver OC-48 Protocol Standard

Synchronization System Performance Benefits of Precision MEMS TCXOs under Environmental Stress Conditions

MultiMaster. Base Station Test Tools. Multi Purpose Base Station Tester. Introduction. Feature

OPEN BASE STATION ARCHITECTURE INITIATIVE

Product Brief 82V3391

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

R1TRFTTE. Nemko Canada Inc. 303 River Road Ottawa, Ontario, Canada, K1V 1H2 +1 (613) Sangoma Technologies

JITTER MEASUREMENT IN PDH/SDH-BASED TELECOMMUNICATION NETWORKS: OPTIMISATION AND PERFORMANCE ASSESSMENT OF A DIGITAL SIGNAL PROCESSING METHOD

User Configurable POSITION 303 DATA OUTPUT 450 HEADING 910

SYNCHRONOUS ETHERNET WAN PLL IDT82V3358

6-1.1 Meters required for POI A/T. Any of the following Network Analyzers for Return loss and cable attenuation:-

ZL30410 Multi-service Line Card PLL

AUTOMOTIVE ETHERNET CONSORTIUM

Computing TIE Crest Factors for Telecom Applications

ETSI EN V1.4.1 ( )

ETSI EN V1.2.1 ( )

8800SX DMR Repeater Test Option 06

Sine Resonance Track & Dwell SRTD

INTERNATIONAL TELECOMMUNICATION UNION. SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital terminal equipments General

GPS NAVSTAR PR (XR5PR) N/A

ProBER 2 2 Mb/s Handheld Test Set. The handheld that takes 2 Mb/s testing beyond convention

MSTM-S3-T2 Stratum 3 Timing Module

Characterize Phase-Locked Loop Systems Using Real Time Oscilloscopes

100G CWDM4 MSA Technical Specifications 2km Optical Specifications

Ansoft Designer Tutorial ECE 584 October, 2004

EUROPEAN ETS TELECOMMUNICATION August 1993 STANDARD

2 Operation. Operation. Getting Started

Introduction to BER testing of WDM systems

Atomic Clock Relative Phase Monitoring How to Confirm Proper Phase Alignment & Stability in the Field

Digital Dual Mixer Time Difference for Sub-Nanosecond Time Synchronization in Ethernet

TX CONTROLLER Model EM-IP Quick Start Guide

S5 (PMR-446) Model Programming software for S5 (PMR-446) Model

Agilent ParBERT Measurement Software. Fast Eye Mask Measurement User Guide

WSTS-2015 Tutorial Session

x-mgc Part Number: FCU-022M101

eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards

Low frequency jitter tolerance Comments 109, 133, 140. Piers Dawe IPtronics. Charles Moore Avago Technologies

K-band Waveguide BPF Design using Agilent EMPro Anurag Bhargava Application Consultant Agilent EEsof EDA

CFORTH-X2-10GB-CX4 Specifications Rev. D00A

SYNCHRONOUS ETHERNET IDT WAN PLL IDT82V3380A

AC : MEASURING THE JITTER OF CLOCK SIGNAL

Application Note Considerations when Choosing a Signal Splitter for DAB ETI Streams

EUROPEAN ETS TELECOMMUNICATION September 1996 STANDARD

EUROPEAN ETS TELECOMMUNICATION January 1994 STANDARD

Digital Microwave Radios

ZL30131 OC-192/STM-64 SONET/SDH/10GbE Network Interface Synchronizer

E1UC - Portable E1 USB Data Capture

Agilent MOI for MIPI D-PHY Conformance Tests Revision 1.00 Dec-1, 2011

Stratum 3 Timing Module STL-S3

Gigabit Ethernet Consortium Clause 38 PMD Conformance Test Suite v.7 Report

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

,787, 35,0$5<5$7(86(51(7:25.,17(5)$&(±/$<(563(&,),&$7,21 ,17(*5$7('6(59,&(6',*,7$/ 1(7:25.,6'1,6'186(51(7:25.,17(5)$&(6 ,7875HFRPPHQGDWLRQ,

Assisted Partial Timing Support Metrics

SWT 3000 Teleprotection technical data siemens.com

Comment Supporting materials: The Reuse of 10GbE SRS Test for SR4/10, 40G-LR4. Frank Chang Vitesse

SM3E ULTRA MINIATURE STRATUM 3E MODULE

Introduction to NFC Tester RWC5010A

EUROPEAN ETS TELECOMMUNICATION April 1994 STANDARD

MT9046 T1/E1 System Synchronizer with Holdover

SYNCHRONOUS ETHERNET WAN PLL IDT82V3385

MOST Essentials - Electrical Compliance and Debug Test Solution for MOST50 and MOST150

PTP 820G Licensed Microwave Radio

G7104A Multimaster Base Station Tester

II. LAB. * Open the LabVIEW program (Start > All Programs > National Instruments > LabVIEW 2012 > LabVIEW 2012)

SCG4540 Synchronous Clock Generators

Keysight MOI for MIPI D-PHY Conformance Tests Revision Oct, 2014

NTIA PTP 820G Licensed Microwave

125 Series FTS125-CTV MHz GPS Disciplined Oscillators

Correct Measurement of Timing and Synchronisation Signals - A Comprehensive Guide

ZL30100 T1/E1 System Synchronizer

Agilent MOI for MIPI M-PHY Conformance Tests Revision Mar 2014

Parameter Conditions & Remarks Min Typical Max Unit. Warm up Steady 25 C Load Output to Ground pf

XENPAK-10GB-LRM XENPAK-10GBASE-LRM 1310nm, 220m Reach

RECOMMENDATION ITU-R F * Pre-emphasis characteristics for frequency modulation radio-relay systems for television

Advanced Test Equipment Rentals ATEC (2832) T-Carrier Analyzer

Transcription:

Testing Sync-E Wander to ITU-T G.8262 This document outlines the test process for testing Wander of FE and 1GbE SyncE network elements to G.8262 using the Calnex Paragon Sync. Covered in this document is; 1. Wander Generation G.8262 Section 8 2. Wander Tolerance G.8262 Section 9 3. Wander Transfer G.8262 Section 10 Appendix 1 - G.8262 Wander Testing; Practical interpretation guidance Appendix 2 - Using a Wander Generator as the Reference Source Appendix 3 - Using a Function Generator as the Reference Source Hardware and Software required. Paragon Sync o o o Option 110 1GbE (Optical and electrical support) Option 203 SyncE features Paragon S/W version x87.1 or higher Wander Generator (JDSU ANT-20) OR Function Generator for Wander Tolerance and Wander Transfer tests Synchronisation Source Calnex Solutions Ltd Page 1 of 17

1. Wander Generation G.8262 Section 8 Test Setup Measurement Setup Paragon Setup a) Start the Paragon GUI b) Select Operating Mode c) Select Sync Ethernet (Wander Measurement) d) Close the Operating Mode Window. Calnex Solutions Ltd Page 2 of 17

e) Select Setup Interface and then Physical Settings f) Uncheck Sync E Clock Rx->Tx (Locks Port 2 to the External Reference Clock) g) Select the External Clock source being used h) Select the Line Rate (100BaseT or 1GbE) i) If 1GbE, select Electrical or Optical Interface j) Close the Window Measurement Process Refer to Appendix 1 for G.8262 testing guidance a) Select the Start Capture button to start measurement. b) For the graph to auto update, select from the menu Graph => Auto Graph Refresh => On c) To stop the measurement select Stop Capture d) To evaluate MTIE and TDEV, select Tools => MTIE/TDEV Analysis. Calnex Solutions Ltd Page 3 of 17

e) The TIE graph will be displayed. f) Click the MTIE/TDEV button at the bottom of the Window and the following window will be displayed g) Ensure the boxes for MTIE and TDEV are ticked Calnex Solutions Ltd Page 4 of 17

h) Tick the Masks box and select either ITU-T/SEC Opt 1 (G.813) or ITU-T/SEC Opt 2 (G.813) and click OK. These G.813 masks are the same as ITU-T/EEC Opt 1 (G.8262) and ITU-T/EEC Opt 2 (G.8262) i) Click the Analysis button and the MTIE and TDEV measurements will be shown and can be analysed against the masks. With the screen also showing a Pass/Fail indication. Calnex Solutions Ltd Page 5 of 17

2. Wander Tolerance G.8262 Section 9 Test Setup Measurement Setup Paragon Setup a) Start the Paragon GUI b) Select Operating Mode c) Select Sync Ethernet (Wander Measurement) d) Close the Operating Mode Window. Calnex Solutions Ltd Page 6 of 17

e) Select Setup Interface and then Physical Settings f) Uncheck Sync E Clock Rx->Tx - (Locks Port 2 to the External Reference Clock) g) Select the External Clock source being used h) Select the Line Rate (100BaseT or 1GbE) i) If 1GbE, select if using Electrical or Optical Interface j) Close the Window Setup of the Wander Generator a) An E1/T1source with a Wander Generator such as a JDSU ANT20 should be used b) For setup refer to Appendix 2 c) Note alternatively a Function Generator can be used to perform this measurement. Refer to Appendix 3 for instructions. Measurement Process Refer to Appendix 1 for G.8262 testing guidance a) Start the Wander test (eg. MTW) on the Wander Generator b) Check that with the wander at the input, the EEC is i. Maintaining the clock within performance limits ii. iii. iv. Not causing any alarms Not causing the clock to switch reference Not causing the clock to go into holdover Calnex Solutions Ltd Page 7 of 17

3. Wander Transfer G.8262 Section 10 Test Setup Measurement Setup Paragon Setup a) Start the Paragon GUI b) Select Operating Mode c) Select Sync Ethernet (Wander Measurement) d) Close the Operating Mode Window. Calnex Solutions Ltd Page 8 of 17

e) Select Setup Interface and then Physical Settings f) Uncheck Sync E Clock Rx->Tx g) Select the External Clock source being used h) Select the Line Rate (100BaseT or 1GbE) i) If 1GbE selected select if using Electrical or Optical Interface j) Close the Window Setup of the Wander Generator a) An E1/T1source with a Wander Generator such as a JDSU ANT20 should be used. For set up refer to Appendix 2 b) Alternatively a Function Generator can be used. Refer to Appendix 3 for instructions. Measurement Process Refer to Appendix 1 for G.8262 testing guidance a) Start the Wander test (eg. MTW) on the Wander Generator b) On the Paragon, select the Start Capture button to start measurement. c) For the graph to auto update select from the menu Graph => Auto Graph Refresh => On d) To stop the measurement select Stop Capture e) To evaluate MTIE and TDEV, select Tools => MTIE/TDEV Analysis. Calnex Solutions Ltd Page 9 of 17

f) The TIE graph will be displayed. g) Click the MTIE/TDEV button at the bottom of the Window and the following window will be displayed. h) Ensure the boxes for MTIE and TDEV are ticked Calnex Solutions Ltd Page 10 of 17

i) Tick the Masks box and select either ITU-T/SEC Opt 1 (G.813) or ITU-T/SEC Opt 2 (G.813) and click OK. These G.813 masks are the same as ITU-T/EEC Opt 1 (G.8262) and ITU-T/EEC Opt 2 (G.8262) j) Click the Analysis button and the MTIE and TDEV measurements will be shown and can be analysed against the masks. With the screen also showing a Pass/Fail indication. Calnex Solutions Ltd Page 11 of 17

Appendix 1 G.8262 Wander Testing; Practical interpretation guidance EEC-Option 1: E1 based hierarchy Test Input Stimulus Pass/Fail Criteria Interpretation Notes Wander Generation not applicable MTIE & TDEV pass/fail masks shown in G.8262 Section 8.1.1. Wander Tolerance Sinusoidal stimulus. Defined in G.8262 Section 9.1.1, Table 8 & Figure 7. The EEC is; i. Maintaining the clock within performance limits ii. Not causing any alarms iii. Not causing the clock to switch reference iv. Not causing the clock to go into holdover {G.8262 Section 9} For item i. of the Pass/Fail Criteria, the Standard states that "The exact performance limits are for further study." (G.8262, Section 9) Without further guidance from the Standards, it is suggested that items ii - iv are the primary methods used for determining conformance. Wander Transfer (Note) Not defined. Gain 0.2dB (2.3%) {G.8262 Section 10} There is no definition of the input stimulus to be used in G.8262. Without further guidance from the Standards, it is suggested that the amplitude and frequency values associated with mask points labelled f1, f2 & f3 on G.8262 Section 8.1.1, Table 8 & Figure 7 are used. Calnex Solutions Ltd Page 12 of 17

EEC-Option 2: T1 based hierarchy Test Input Stimulus Pass/Fail Criteria Interpretation Notes Wander Generation not applicable MTIE & TDEV pass/fail masks shown in G.8262 Section 8.1.2. Input Stimulus: A TDEV graph is defined in the input stimulus in G.8262. General purpose modulation sources capable of this output are not readily available. Without further guidance from the Standards, the following approaches are suggested; Wander Tolerance TDEV stimulus. Defined in G.8262 Section 9.1.2, Table 9 & Figure 8. The EEC is; i. Maintaining the clock within performance limits ii. Not causing any alarms iii. Not causing the clock to switch reference iv. Not causing the clock to go into holdover A) In general, the Wander Tolerance requirements are more severe for Option 1 type networks than Option 2 type networks in G.8262 and in G.812. Therefore, if the equipment is being designed for both networks, testing to Option 1 requirements as specified above will suffice. B) If the equipment only requires to comply with Option 2 type networks, comparing the limits in G.812 to G.8262, they are very similar. In the absence of guidance from the Standards, it is suggested that a set of points with amplitude and frequency values from the mask defined in G.812 Section 9.1.3, Table 14 & Figure 5 are used as the stimulus. {G.8262 Section 9} Pass/Fail Criteria: For item i. of the Pass/Fail Criteria, the Standard states that "The exact performance limits are for further study." (G.8262, Section 9) Without further guidance from the Standards, it is suggested that items ii - iv are the primary methods used for determining conformance. Wander Transfer (Note) Not defined. Gain 0.2dB (2.3%) {G.8262 Section 10} A TDEV graph is defined in the input stimulus in G.8262. General Purpose Modulation Sources capable of this output are not readily available. In the absence of guidance from the Standards, it is suggested that a set of points with amplitude and frequency values from the mask defined in G.812 Section 9.1.3, Table 14 & Figure 5 are used as the stimulus. Calnex Solutions Ltd Page 13 of 17

Testing configuration for the Wander Transfer Measurement. The figure below from G.8264 shows the conceptual block diagram for an Ethernet Equipment Clock (EEC). It shows that the selection between the various sources of the reference input is performed before the configured source is applied to the Synchronous Equipment Timing Generator (SETG) i.e. the internal clock generation function. Inputs Outputs Selector A Selector C T4 -> External ETY -> TE STM-N -> T1 PDH -> T2 External -> T3 Selector B SETG G.813/ G.8262 T0 -> SDH / ETH equip. Figure A.2/G.8264: Hybrid SDH/Synchronous Ethernet SETS function Each input will have its own clock recovery circuit to recover frequency from the input signal. It is reasonable to assume that while these input functions are sensitive to jitter, that they will be transparent to Wander. This means that when doing a Wander Transfer measurement, it is effectively the transfer function of the SETG block that is being assessed. Therefore to perform an assessment of the Wander Transfer of the UUT, the input wander can be modulated on to any of the inputs that can be selected as the reference input to the internal SETG function. The configuration diagram in Chapter 3: Wander Transfer - G.8262 Section 10 of this document proposes the approach of modulating the Wander on to the BITS clock input. (The UUT would be configured to use the BITS input as the source of the reference clock.) If there is concern that a different internal topology has been adopted to that shown in the block diagram below or that the input stages may be impacting the Wander Transfer, an alternative configuration can be used, where a Paragon is utilised to modulate Wander on to the SyncE input to the UUT. For this testing approach, the UUT would be configured to use the SyncE input as the source of the reference clock. Refer to the diagram in Chapter 2: Wander Tolerance - G.8262 Section 9 of this document for guidance on how to modulate Wander on to the SyncE input. Calnex Solutions Ltd Page 14 of 17

Appendix 2 - Using a Wander Generator as the Reference Source Below are the wander frequencies and UI values that should be used, if a Wander Generator such as an ANT20 is used, to supply the reference Frequency to the Paragon for the Wander Transfer and Wander Tolerance tests. Note the UI values are calculated assuming an E1 or 2MHz link is used Wander Frequency (Hz) 0.00032 0.0008 0.016 0.13 10 Amplitude (UI) on 2MHz/E1 10.2 4.1 4.1 0.5 0.5 ANT20 Configuration It is possible for the ANT20 to automatically sweep through the values in the table above using the MTW function. The Sync port of the Paragon should be connected to the ANT20 TX port via a T adapter as it is necessary to also feed the TX signal back into the RX port of the ANT20, otherwise an alarm will be seen and the MTW measurement will not start Calnex Solutions Ltd Page 15 of 17

Appendix 3 - Using a Function Generator as the Reference Source Frequency Modulation is defined by the carrier frequency, the modulating frequency and the peak frequency deviation. Below are the modulating frequencies and peak frequency deviation values that should be used to supply the reference Frequency to the Paragon for the Wander Transfer and Wander Tolerance tests. This assumes a carrier frequency of 10MHz. Modulating Frequency (Hz) 0.00032 0.0008 0.016 0.13 10 Peak Frequency Deviation (Hz) 0.05026 0.05026 1.0053 1.0210 78.539 Resultant Amplitude on 10MHz carrier (us) 5.0 2.0 2.0 0.25 0.25 The Voltage output should be set to nominal amplitude of 1.5V peak. If additional values on the G8262 profile are required, the Frequency deviation setting can be calculated by solving the following equation for fdev: Where: fo = carrier frequency fdev = peak deviation frequency fmod = modulation or wander frequency Synchronise the Function Generator to the Master Reference to ensure the Wander is always locked to the Reference clock. 10MHz Master Clock 10MHz network reference Function Generator 10MHz with wander Calnex Solutions Ltd Page 16 of 17

For more information on the Calnex Paragon Sync, and to take advantage of Calnex s extensive experience in sync and packet testing technologies, please contact Calnex Solutions on +44 (0) 1506 671 416 or email: info@calnexsol.com Calnex Solutions Ltd Springfield, Linlithgow West Lothian EH49 7NX United Kingdom tel: +44 (0) 1506 671 416 email: info@calnexsol.com www.calnexsol.com This information is subject to change without notice Calnex Solutions Ltd, 2009