NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

Similar documents
POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

Electrical Specifications

Electrical Specifications

Electrical Specifications

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

General. Environmental. EMC & Safety

C B. Models. Models 2MOPP

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

150 Watt Industrial (WLT)

Electrical Specifications

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

LB115S 115W Single Output

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Electrical Specifications

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

VOF XX - XXX - X

LFWLP W 12V 15.00A 25.00A 92%

TB65 65W Single Output Test and Measurement/Industrial Series

VP ELECTRONIQUE MASSY - Tel:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Metal Case Power Supplies

For more information, please visit the product page. output. output current max (A)

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

FED30-48 S 05 - N HC Series Name Input Output Output Remote Control Assembly Option Voltage Quantity Voltage Option PART NUMBER STRUCTURE

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

VMS-300A - XX - XXX - X

SF60/61P & SFU60/61P Series

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

General. Environmental. EMC & Safety

Output Full Load

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

PDAM500 Series 500W Power Supply

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

WAF S 12 W - N S DR Series Name Input Output Output Input Remote Control Load Share Assembly Voltage Quantity Voltage Range Option Option Option

Output Voltage (Vfan) Convection-cooled (6,7) Forced-cooled (8) & Current

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

FED30-48 S 05 W - N HC Series Name Input Output Output Input Remote Control Assembly Option Voltage Quantity Voltage Range Option

Watts HCP Series

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

MTC Series 15 W AC/DC Switching Power Supply Module Medical

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

Output Voltage (Vfan) & Current

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

MI2000ERW. Series. Miniature 1 x 1 20W, Ultra-Wide 2:1 Input DC/DC Con vert ers. Key Features:

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Electrical Specifications

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

HEC-45LTN-45PFAS Rev A

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

DN03S/D Series DC/DC CONVERTER 2-3W, DIP-Package

Output Voltage* (nom.)(adjustable)

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

AC-DC ITE & Medical Switching Power Supply

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

Model Number Output V1/V2/V3 Output I1/I2/I3 max. Ripple & Noise Efficiency(min/nom) Capacitive Load

AC-DC ITE & Medical Switching Power Supply

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

TE60 60W Single Output External Power Test & Measurement/Industrial Series

500 ma DC-DC Step Down Converter P78G-Series

CCH400 & CCH600 Series

Ripple & Max. capacitive Output Current

Power Supplies. Certifications and Compliances Recognized Component, ITE - UL Certified, ITE - CSA C22.2 CSA


25 Watt QMZ Single and Dual Series

Encapsulated Power Supply

QUARTER-BRICK SERIES Single Output Performance Products

MB120S 120W Single Output Medical Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series

POWER. CPS250-M Series. 250 Watt AC-DC Power Supplies. Data Sheet. Total Power: 250 Watts Input Voltage: V # of Outputs: Single

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

Transcription:

Total Power: 40-50 W Input Voltage: 90-264 VAC 120-370 VDC # of Outputs: Single, dual, triple SPECIAL FEATURES 4.25 x 2.5 x 1.15 inch package (1U applications) Universal input Overvoltage and short circuit protection 40 W with free air convection EN55022, EN55011 conducted emission level B EN61000-4-2, -3, -4, -5, -6 immunity compliant UL, VDE and CSA safety approvals NLP40 enclosure kit available SAFETY VDE0805/EN60950/IEC950 File 10401-3336-0093 Licence No. 93662 UL 60950 File No. E132002 CSA C22.2 No. 950 File No. LR41062C Electrical Specifications Input Input voltage range (See Note 9) Input frequency range Input surge current Safety ground leakage current Input current Universal input 120 Vac, cold start 230 Vac, cold start 120 Vac, 60 Hz 230 Vac, 50 Hz 120 Vac 230 Vac 90-264 Vac 120-370 Vdc 47-440 Hz 15 A max. 30 A max. 0.2 ma 0.4 ma 1.4 A rms 0.7 A rms Input fuse UL/IEC127 250 Vac H 3.15 A Output Total regulation (Line and load) Main output Auxiliary outputs ±2.0% ±5.0% Rise time At turn-on 1.0 s, max. Transient response Main output 25% step at 0.1 A/μs 5.0% max. dev., 1 ms rec. to 1.0% Temperature coefficient ±0.02%/ C Overvoltage protection Main outputs 135%, ±15% Short circuit protection Cyclic operation Continuous Minimum output current Single Multiple 0 A (See Note 5) /artesyn-nlp40-power-supply.html

EMC Charateristics (10) Conducted emissions EN55022, FCC part 15 Level B Radiated emissions EN55022, FCC part 15 Level A ESDair EN61000-4-2, level 3 Perf. criteria 1 ESD contact EN61000-4-2, level 3 Perf. criteria 1 Surge EN61000-4-5, level 3 Perf. criteria 1 Fast transients EN61000-4-4, level 3 Perf. criteria 1 Radiated immunity EN61000-4-3, level 3 Perf. criteria 1 Conducted immunity EN61000-4-6, level 3 Perf. criteria 1 General Specifications Hold-up time 120 Vac 230 Vac 12 ms @ 40 W 20 ms @ 40 W Efficiency 75% typical Isolation voltage Input/output Input/chassis 3000 Vac 1500 Vac Switching frequency Fixed 65 khz, ±5 khz Approvals and standards (See Note 8) Weight UL, CSA VDE 60950, IEC950, UL1950 VDE0805, CSA C22.2 No. 950 200 g (7.06 oz) MTBF demonstrated MIL-HDBK-217F 150,000 hours min. Environmental Specifications Thermal performance Operating ambient (see derating curve) 0 C to +70 C (See Notes 6, 7, 9) Non-operating -40 C to +70 C 50 C to 70 C ambient, convection cooled Derate to 50% load 0 C to 50 C ambient, convection cooled 40 W 0 C to 50 C ambient, 20 CFM forced air 50 W Peak (0 C to +50 C, 60 s) (See Note 2) Relative humidity: Non-condensing 5 to 95% RH Altitude: Operating 10,000 feet max. Non-operating 30,000 feet max. Vibration (See Note 4): 5-500 Hz 2.4 G rms peak Shock Per MIL-STD-810E 516.4 Part IV /artesyn-nlp40-power-supply.html

Output Output Current Total Ripple (3) Voltage Max (1) Peak (2) Fan (1) Regulation Model Number (11,12) +3.3 V (I A) 4 A 5 A 4.5 A 50 mv ±2.0% NLP40-76T366J (5) 12 V (I C) 0.2 A 1 A 0.5 A 120 mv ±5.0% +5 V (I A) 4 A 5 A 4.5 A 50 mv ±2.0% NLP40-7608J (5) 12 V (I C) 0.2 A 1 A 0.5 A 120 mv ±5.0% +5 V (I A) 4 A 5 A 4.5 A 50 mv ±2.0% NLP40-7610J (5) +15 V (I B) 1.6 A 2 A 2 A 150 mv ±5.0% 15 V (I C) 0.2 A 1 A 0.5 A 150 mv ±5.0% +12 V (I A) 1.8 A 2.2 A 2.1 A 120 mv ±2.0% NLP40-7627J (5) -12 V (I B) 1.8 A 2.2 A 2.1 A 120 mv ±5.0% +5 V (I A) 4 A 5 A 4.5 A 50 mv ±2.0% NLP40-7629J (5) 3.3 V (I A) 8 A 10 A 9 A 50 mv ±2.0% NLP40-76S3J 5 V 8 A 10 A 9 A 50 mv ±2.0% NLP40-7605J 12 V 3.3 A 4.5 A 4 A 120 mv ±2.0% NLP40-7612J 15 V 2.6 A 3.6 A 3.3 A 150 mv ±2.0% NLP40-7615J 24 V 1.6 A 2.5 A 2 A 240 mv ±2.0% NLP40-7624J 48 V 0.8 A 1.1 A 1 A 300 mv ±2.0% NLP40-7617J Notes 1. Maximum output power is 40 W for natural convection cooling. With 20 CFM fan cooling, the maximum output power is 50 W. 2. Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total reg. limits. 3. Figure is peak-to-peak. Output noise measurements are made across a 50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 μf capacitor. 4. Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. 5. For multiple output units (except -7627J, 76T366J) to maintain stated regulation then: 0.25 I A / I B 5, for I B > 0.3 A 0.50 I A / I B 5, for I B < 0.3 A For maximum output current I(C) on triple output models, i.e. for I C = IMax., I Amin. 0.5 A and I A I B. For NLP40-7627J only, to maintain stated regulation then: 0.5 I A/ I B 2. For NLP40-76T366J only, to maintain stated regulation then: 0.25 I A/ I B 4. 6. For optimum reliability, no part of the heatsink should exceed 120 C, and no semiconductor case temperature should exceed 130 C. 7. CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. 8. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 9. When the input voltage is <90 Vac the operating range is 0 C to +40 C. /artesyn-nlp40-power-supply.html

10. For system EMI compliance, a ground choke may be required before connecting the ground wire to the chassis. It is recommended that this ground choke be placed as close as possible to the systems ac inlet to eliminate noise pick-up in the system. 11. The J suffix indicates that these parts are Pb-free (RoHS6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliantversions may be available on special request, please contact your local sales representative for details. 12. NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/power to find a suitable alternative. DERATING CURVE Output Power (Watts) 50W 20 CFM FORCED AIR COOLING 40W NATURAL CONVECTION COOLING 25W 20W 0 C 10 C 20 C 30 C 40 C 50 C 60 C 70 C Mechanical Drawing 4.25 (107.95) 4.00 (101.60) 0.125 (3.175) J1 N L F1 1 2.50 (63.50) P1 J2 2.25 (57.15) C5 T1 ALL DIMENSIONS IN INCHES (mm) MAXIMUM COMPONENT HEIGHT 1.15 (29.21) TOLERANCE:.xxx ± 0.005".xx ± 0.02" Mounting Hole Diameter 0.138 (3.50) Typical /artesyn-nlp40-power-supply.html

Input Pin Connections J1 Pin 1 Pin 2 Pin 3 P1 Pin 1 AC Line No Pin AC Neutral Safety Ground Output Pin Connections J2 SINGLE DUAL TRIPLE Pin 1 +Vout V (B) V (B) Pin 2 +Vout V (A) V (A) Pin 3 +Vout V (A) V (A) Pin 4 Return Return Return Pin 5 Return Return Return Pin 6 Return Return V (C) Input and Output Connectors Mating Connectors AC (J1) Molex 26-60-4030 type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimpterminals DC (J2) Molex 26-60-4060 type Molex 09-50-3061 with Triurcon 6838 or equivalent crimp terminals /artesyn-nlp40-power-supply.html