AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

Similar documents
AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters

Absolute Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters

Differential Pressure Transmitters

Absolute Pressure Transmitters

AT9000 Advanced Transmitter Differential Pressure Transmitters

PTG series Smart Pressure Transmitter

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

General Specifications

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

General Specifications

General Specifications

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

PAD - Heavy Duty Differential Pressure Trasmitter

Field IT 2600T Series Pressure Transmitters

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

General Specifications

General Specifications

ST3000 ACE Smart Transmitter JTD Series of Differential Pressure Transmitters. Model JTD910A/920A/930A/960A/921A/931A/961A

JTD Series of Differential Pressure Transmitters

General Specifications

General Specifications

General Specifications

General Specifications

Smart Pressure Transmitter

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

General Specifications

General Specifications

General Specifications

General Specifications

DRS390 High stability, flange mounting

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

General Specifications

Fuji Electric France S.A.S. ABSOLUTE PRESSURE TRANSMITTER FEATURES SPECIFICATIONS FKH...5 DATA SHEET

ED701 General Industry Pressure Transmitter

Pressure transmitter (Direct mount type) Caractéristique fonctionnelles FKP* { } {1.3} FKP* {0.

General Specifications

PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

Field indicator for current loops with HART communication Models DIH50, DIH52

General Specifications

General Specifications

General Specifications

General Specifications

ABSOLUTE PRESSURE TRANSMITTER

Rosemount 3101, 3102, and 3105

Fuji Electric France S.A.S. ABSOLUTE PRESSURE TRANSMITTER

General Specifications

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

General Specifications

FKH...5. Absolute pressure transmitter DATA SHEET FEATURES SPECIFICATIONS. Functional specifications

AT9000 Advanced Transmitter Electronic Differential Pressure/ Pressure Transmitter with DE and HART Bilingual Communications.

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

General Specifications

General Specifications

General Specifications

MagneW Two-wire PLUS+ Two-wire Electromagnetic Flowmeter

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

IP26 Series Current to Pneumatic Converter

Data Sheet SS/265VS-EN_1

General Specifications

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

General Specifications

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

FKG... 5 PRESSURE TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

General Specifications

Fuji Electric France S.A.S. PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) FEATURES SPECIFICATIONS FKP...5 DATA SHEET. Functional specifications.

FKP... 5 PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) FEATURES SPECIFICATIONS. Functional specifications

Compact Orifice Flow Meter

General Specifications

General Specifications

General Specifications

Series Smart Pressure Transmitter

General Specifications

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

Field indicator for current loops with HART communication Models DIH50, DIH52

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

SATRON VB Pressure Transmitter

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Series 10-ZSE30A(F)/10-ISE30A

General Specifications

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

General Specifications

General Specifications

FUNCTIONAL SPECIFICATIONS

General Specifications

General Specifications

Transcription:

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable of measuring gas, liquid and vapor, it transmits 4 to 20 ma DC analog and digital signals according to the measured pressure. It can also execute two-way communications between the Communicator, thus facilitating self-diagnosis, range resetting, and automatic zero/span adjustment. SFN, HART and FOUNDATION Fieldbus are available. * Refer to SS2-GTX00Z-0100 for FOUNDATION Fieldbus type for the items marked with [ ]. FEATURES High performance and stability Unique characterization and composite semiconductor sensors realize high accuracy up to 0.04 % F.S. Our proven sensor technology enables Long-term stability up to 0.1 % of URL per 10-year. Wide measuring range (range ability) A wide measuring range is available from a single model. This feature is highly effective in taking measurement over a wide range and reducing the need for inventory. Model GTX60G: 17.5 to 3500 kpa (range ability: 200 to 1) Model GTX71G: 0.7 to 14 MPa (range ability: 200 to 1) High durability Max. range pressure test is cleared more than 100,000 times. Remote communication Two-way communication using digital output facilitates self-diagnosis, range resetting, automatic zero adjustment, and other operations. China RoHS This device is used in the Oil & Gas, Petrochemical, Chemical, Pulp & Paper, Food & Beverage, Machinery, Steel/Metal & Mining, and Automobile industries and therefore does not fall under the China RoHS Legislation. If this device is used in semiconductor manufacturing equipment, labeling on the device and documents for the China RoHS may be required. If such documents are required, consult an Azbil Corp. representative. Anti-vibration specification is up to 3G. HART is a registered trademark of the FieldComm Group. FOUNDATION is a registered trademark of the FieldComm Group. Specifications are subject to change without notice. This product is designed for general industrial use. 1 4th edition

PRODUCT APPROVALS [ ] FM Explosionproof for Division System/ Flameproof for Zone System (Code F1) Explosionproof for Class I, Division 1, Groups A, B, C and D; Class I, Zone 1, AEx d IIC Dust-Ignitionproof for Class II, III, Division 1, Groups E, F and G T5 40 C Tamb +85 C Hazardous locations Indoor/Outdoor Type 4X, IP67 Factory sealed, conduit seal not required for Division applications Caution - Use supply wires suitable for 5 C above surrounding ambient FM Intrinsic Safety (Code F2) IS/I, II, III/1/ABCDEFG/T4; 40 C Tamb +60 C; 80395278, 80395279, 80395280; Entity; TYPE 4X; IP67 I/0/AEx ia/iic/t4; 40 C Tamb +60 C; 80395278, 80395279, 80395280; Entity; TYPE 4X; IP67 Entity Parameters: Vmax (Ui)=30 Volts, Imax (Ii)=100 ma, Pi=1 W, Ci=10 nf, Li=0.5 mh FM Nonincendive (Code F5) NI/I/2/ABCD/T4; 40 C Tamb +60 C; 80395494; NIFW; TYPE 4X; IP67 NI/I/2/IIC/T4; 40 C Tamb +60 C; 80395494; NIFW; TYPE 4X; IP67 S/II, III/1/EFG/T4; 40 C Tamb +60 C; 80395494; NIFW; TYPE 4X; P67 Nonincendive Field Wiring Parameters: Vmax (Ui)=30 Volts, Ci=10 nf, Li=0.5 mh Combination of F1, F2 and F5 (Code F6) ATEX Flameproof (Code A1) 0344 KEMA 08ATEX0004 II 1/2 G Ex d IIC T6 Tprocess=85 C IP66/67 II 1/2 G Ex d IIC T5 Tprocess=100 C 30 C Tamb +80 C IP66/67 II 1/2 G Ex d IIC T4 Tprocess=110 C 30 C Tamb +80 C IP66/67 II 2 D Ex td A21 IP66/67 T85 Tprocess=85 C II 2 D Ex td A21 IP66/67 T100 Tprocess=100 C II 2 D Ex td A21 IP66/67 T110 Tprocess=110 C Caution - Use supply wires suitable for 5 C above surrounding ambient ATEX Intrinsic Safety (Code A2) Azbil Corporation 0344 KEMA 07ATEX0200 X II 1 G Ex ia IIC T4 Tprocess=105 C 30 C Tamb +60 C IP66/67 Electrical Parameters: Ui=30 V, Ii=93 ma, Pi=1 W, Ci=5 nf, Li=0.5 mh II 1 D Ex iad 20 IP66/67 T105 Tprocess=105 C 30 C Tamb +60 C NEPSI Flameproof (Code N1) Ex d IIC T6 DIP A21 TA 85 C Tprocess=80 C 30 C Tamb +75 C Ex d IIC T5 DIP A21 TA 100 C Tprocess=95 C 30 C Tamb +80 C Ex d IIC T4 DIP A21 TA 115 C Tprocess=110 C 30 C Tamb +80 C ENCLOSURE TYPE IP66/67 NEPSI Intrinsic Safety (Code N2) Ex ia IIC T4 Tprocess=105 C 30 C Tamb +60 C Enclosure IP66/67 Electrical Parameters: Ui=30 V, Ii=100 ma, Pi=1 W, Ci=13 nf, Li=0.5 mh NEPSI Type n (Code N5) Ex nl IIC T4 Tprocess=110 C 30 C Tamb +60 C Enclosure IP66/67 Electrical Parameters: Ui=30 V, Ii=100 ma, Pi=1 W, Ci=13 nf, Li=0.5 mh IECEx Flameproof (Code E1) Certificate No. IECEx KEM 08.0001 Ga/Gb Ex d IIC T6 Tprocess=85 C IP66/67 Ga/Gb Ex d IIC T5 Tprocess=100 C 30 C Tamb +80 C IP66/67 Ga/Gb Ex d IIC T4 Tprocess=110 C 30 C Tamb +80 C IP66/67 Ex td A21 IP66/67 T85 Tprocess=85 C Ex td A21 IP66/67 T100 Tprocess=100 C Ex td A21 IP66/67 T110 Tprocess=110 C Caution - Use supply wires suitable for 5 C above surrounding ambient IECEx Intrinsic Safety (Code E2) IECEx KEM 07.0058X Zone 0 Ex ia IIC T4 Tprocess=105 C 30 C Tamb +60 C IP66/67 Electrical Parameters: Ui=30 V, Ii=93 ma, Pi=1 W, Ci=5 nf, Li=0.5 mh Ex iad 20 IP66/67 T105 Tprocess=105 C 30 C Tamb +60 C 2

Azbil Corporation KOSHA Flameproof (Code K1) Ex d II C T6 Tprocess=85 C Ex d II C T5 Tprocess=100 C 30 C Tamb +80 C Ex d II C T4 Tprocess=110 C 30 C Tamb +80 C EMC Conformity [ ] EN 61326-1 (industrial electromagnetic environment) EN 61326-2-3 FUNCTIONAL SPECIFICATIONS No. SS2-GTX00G-0200 Power Supply [ ] 12.5 to 42 V DC Limited to 12.5 to 30 V DC for intrinsic safety, Type n, Nonincendive types Power Supply voltage and load resistance characteristics [ ] See Figure 3. Limited to Load resistance: 250 to 1345 Ω for SFN or DE communication. 250 to 600 Ω for HART communication. Power supply voltage: 12.5 to 30 V DC for intrinsic safety, Type n, Nonincendive types 1345 Type of protection NEMA 3 and 4X IEC IP66/67 = Supply voltage 12.5 0.0219 Measuring span/setting range/overload Resistance value 799 600 Model Measuring Span Setting Range GTX 60G 17.5 to 3500 kpa {0.175 to 35 kgf/cm 2 } 100 to +3500 kpa { 1 to +35 kgf/cm 2 } Overload Resistance value 5250 kpa {52.5 kgf/cm 2 } 250 0 GTX 71G 0.7 to 14 MPa {7 to 140 kgf/cm 2 } 0.1 to +14 MPa { 1 to +140 kgf/cm 2 } 21 MPa {210 kgf/cm 2 } 12.5 18 25.6 30 Supply voltage (V DC) 42 Figure 3. Supply voltage vs. load resistance characteristics Working pressure P kpa {mmhg} 101.3 {760} 100 6.67 2 {1.5} Normal operating range Operative limit 21.1 40 0 40 63 85 115 Temperature of wetted parts ( C) Figure 1. Working pressure and temperature of wetted parts section (for general purpose models) Note) For communication with a communicator, a load resistance of 250 Ω or more is necessary. Output [ ] Analog output (4 to 20 ma DC) with DE protocol Analog output (4 to 20 ma DC) with HART protocol Digital output (DE protocol) Output signal [ ] 3.6 to 21.6 ma 3.8 to 20.5 ma (NAMUR NE43 compliant) Failure Alarm [ ] Upper: 21.6 ma or more Lower: 3.6 ma or less Working pressure P kpa {mmhg} 101.3 {760} 53 {400} Operative limit Normal operating range Operative limit 40 10 0 40 70 80 Temperature of wetted parts ( C) Figure 2. Working pressure and temperature of wetted parts section (for oxygen and chlorine service) 3

Ambient temperature limit Normal operating range 25 to +85 C for general purpose models 10 to +85 C for oxygen and chlorine models Operative limits 40 to +85 C for general purpose models 40 to +80 C for oxygen and chlorine models 30 to +85 C for models with digital indicators Transportation and storage conditions 40 to +85 C Temperature ranges of wetted parts Normal operating range 25 to +85 C for general purpose models 10 to +70 C for oxygen and chlorine models Operative limits 40 to +85 C for general purpose models 40 to +80 C for oxygen and chlorine models Ambient humidity limits 5 to 100 %RH Stability against supply voltage change ±0.005 %FS/V Response time [ ] Below 100 msec. (when damping time is set to 0 sec.) Damping time [ ] Selectable from 0 to 32 sec. in ten stages (SFN) Adjustable from 0 to 120 sec. (HART) Zero Stability ±0.1 % of URL per 10 year (GTX60G) ±0.2 % of URL per 10 year (GTX71G) Lightning protection [ ] Applicable Standards; IEC 61000-4-5 Peak value of current surge (80/20 μ sec.): 6000 A Vibration effect Paint code X, H Less than ±0.1 % of URL, field or pipeline with high vibration level (10 60 Hz, 0 0.21 mm peak displacement/ 60 2000 Hz, 3 g) Paint code E Less than ±0.1 % of URL, field with general application or pipeline with low vibration level (10 60 Hz, 0 0.15 mm peak displacement/60 500 Hz, 2 g) Azbil Corporation Indicator The digital LCD indicator (optional) shows the output in percentage or in engineering units. Range for engineering unit is from -99999 to 99999 when set at the factory, and from -19999 to 19999 when using the communicator. Specify the following items when placing order with engineering units, Pressure range Engineering unit of pressure Method of display, either linear or square-root. These data may be set or changed using the communicator. OPTIONAL SPECIFICATIONS Oil free finish The transmitter is shipped with oil-free wetted parts. External zero/span adjustment function The transmitter can be easily adjusted to zero or span in the field. Indicator must be selected to enable this option. Fieldbus type does not have span adjustment. Elbow This is an adaptor for changing the electrical conduit connection port from the horizontal to the vertical direction, if required by wiring conditions in the field. One or two elbows may be used as needed. Conformance to Non SI units We deliver transmitters set to any Non SI units as specified. Safety Transmitter Select this option to be used as a component of Safety Instrument System (SIS). AT9000 is complied with IEC61508, certified according to Safety Integrity Level 2 (SIL-2) This option is not applicable for FOUNDATION Fieldbus type, DE communication type, external zero/span adjustment (option A2), and Alarm output (option Q7). Alarm Output (contact output) Contact output is prepared as alarm output when alarm (Output Alarm/Sensor Temp. Alarm) condition is detected. It can be set to or Normally Close. Contact output type: One open collector (NPN) Contact rating: 30 V DC max., 30 ma DC max. Residual voltage at output ON: 3.0 V max. Operating mode: Normally Open (default) Normally Close is not recommended. When this option is selected, CHECK terminals for current check cannot be used. This option is not applicable for FOUNDATION Fieldbus type, and with intrinsic safety, Type n, Nonincendive types. Advanced diagnostics [ ] This option is applicable for FOUNDATION Fieldbus type. Refer to SS2-GTX00Z-0100. Custom calibration Calibrate for the specified pressure range at the factory. 4

Azbil Corporation PHYSICAL SPECIFICATIONS Materials Fill fluid Silicone oil for general purpose models Fluorine oil for oxygen and chlorine models Center body 316 SST Transmitter case Aluminum alloy, CF8M (Equivalent to 316 SST) O-ring NBR Paint Standard: Baked acrylic paint Corrosion-proof: Baked urethane paint Color Housing: Silver N-8.2 Cap: azbil bordeaux 2.5R 2.25/5 Weight Approx. 1.3 kg INSTALLATION Electrical connection 1/2 NPT internal thread, M20 internal thread. Grounding Resistance 100 Ω max. Mounting Can be installed on a 2-inch horizontal or vertical pipe (can be directly mounted on a process pipe) Process connection Male: 1/2 NPT, R 1/2, G 1/2, M20 1.5 Female: 1/2 NPT, Rc 1/2 No. SS2-GTX00G-0200 TRANSMITTER HANDLING NOTES To get the most from the performance this transmitter can offer, please use it properly noting the points mentioned below. Before using it, please read the Instruction Manual. Transmitter installation notes WARNING When installing the transmitter, ensure that gaskets do not protrude from connecting points into the process (such as adapter flange connection points and connecting pipes and flanges). Failure to do so may cause a leak of process fluid, resulting in harm from burns, etc. In addition, if the process fluid contains toxic substances, take safety measures such as wearing goggles and a mask to prevent contact with the skin and eyes and to prevent inhalation. Use the transmitter within the operating ranges stated in the specifications (for explosion-proofing, pressure rating, temperature, humidity, voltage, vibration, shock, mounting direction, atmosphere, etc.). Using the transmitter outside the operating conditions may cause device failure or fire, resulting in a harmful physical risk of burning or the like. When performing wiring work in explosion-proof areas, follow the work method specified in the explosion-proof guidelines. CAUTION After installation, do not use the transmitter as a foothold or put your weight on it. Doing so may cause damage. Be careful not to hit the glass indicator with tools etc. This could break the glass and cause injury. The transmitter is heavy. Wear safety shoes and take care when installing it. Impact to transmitter can damage sensor module. Wiring notes WARNING To avoid shocks, do not perform electrical wiring work with wet hands or with live wires. CAUTION Do wiring work properly in conformance with the specifications. Wiring mistakes may result in malfunction or irreparable damage to the instrument. Use a power supply that conforms to the specifications. Use of an improper power supply may result in malfunction or irreparable damage to the instrument. Use a power supply with overcurrent protection for this instrument. 5

Handling precautions for HART specification devices Azbil Corporation If you need to operate with a secondary host (HART communicator, etc.), set the communication interval of the primary host (DCS, device management system) to 8 seconds or more, or suspend communication from the primary host. If the primary host repeats HART communication within 8 seconds, the request from the secondary host may not be received (communication may not be possible). If electrical noise in the environment prevents HARTcommunications with the host, take countermeasures such as separating the signal cables from the source of the noise, improving the grounding, changing to shielded signal cables, etc. Even if noise interferes with HART communications, the 4 20 ma analog signal will be unaffected and can be used for control. If this product is being operated in multidrop mode, there is a limit to the number of devices that can be used. If you are using multidrop mode, please consult with us. PERFORMANCE SPECIFICATIONS Reference accuracy Shown for each item are the percentage ratio for x (kpa), which is the greatest value of either the upper range value (URV) *1, the lower range value (LRV) *2 or the span. Model GTX60G (for regular type) Material of wetted parts: Diaphragm; 316L SST, Others; 316 SST Reference accuracy * 3 * 4 * 5 ±0.04 % (For x 350 kpa {3.5 kgf/cm 2 }) Ambient Temperature effect (Shift from the set range) Change of 30 C * 3 Combined shift: (including zero and span shifts) ± ( 0.008+0.032 350 ) % x (For x<350 kpa {3.5 kgf/cm 2 }) ±0.15 % (For x 350 kpa {3.5 kgf/cm 2 }) ± ( 0.075+0.075 350 ) % x (For x<350 kpa {3.5 kgf/cm 2 }) Model GTX60G (for oxygen/chlorine service) Material of wetted parts: Diaphragm; 316L SST, Others; 316 SST Reference accuracy * 3 * 4 ±0.075 % (For x 1750 kpa {17.5 kgf/cm 2 }) ±0.1 % (1750 kpa {17.5 kgf/cm 2 }>x 140 kpa {1.4 kgf/cm 2 }) Temperature characteristics (Shift from the set range) Change of 30 C * 3 (Range from 5 to +55 ºC) Combined shift: (including zero and span shifts) ± ( 0.025+0.075 140 ) % x (For x<140 kpa {1.4 kgf/cm 2 }) ±0.44 % (For x 350 kpa {3.5 kgf/cm 2 }) ± ( 0.19+0.25 350 ) % x (For x<350 kpa {3.5 kgf/cm 2 }) Model GTX71G (for regular type/oxygen/chlorine service) Material of wetted parts: Diaphragm; 316L SST, Others; 316 SST Reference accuracy * 3 * 4 ±0.15 % (For x 2.1 MPa {21 kgf/cm 2 }) Ambient Temperature effect (Shift from the set range) Change of 30 C * 3 Combined shift: (including zero and span shifts) ± ( 0.05+0.1 2.1 ) % x (For x<2.1 MPa {21 kgf/cm 2 }) ±0.41 % (For x 3.5 MPa {35 kgf/cm 2 }) ± ( 0.18+0.23 3.5 ) % x (For x<3.5 MPa {35 kgf/cm 2 }) *1. URV denotes the process value for 100 % (20 ma DC) output. *2. LRV denotes the process value for 0 % (4 ma DC) output. *3. Within a range of URV 0 and LRV 0. *4. Reference accuracy at calibrated condition. *5. In case code D Digital output (DE communication) is selected, reference accuracy becomes the same as one of for oxygen/chlorine service. 6

Azbil Corporation MODEL SELECTION No. SS2-GTX00G-0200 Model GTX60G (Standard gauge pressure, In-line model) Model No.: GTX G - Selection I (I II III IV V VI VII) - Selection II (I II III IV V VI) - Option Basic Model No. Measuring span 17.5 to 3500 kpa (0.175 to 35 kgf/cm 2 ) GTX60G Selection I I Output 4 to 20 ma (SFN Communication) A 4 to 20 ma (HART Communication) B FOUNDATION Fieldbus communication C Digital output (DE communication) * 1 D II Fill fluid Regular type (Silicone oil) A For oxygen service (Fluorine oil) (not yet available) H III Material (Meterbody Meterbody cover Vent/Drain plugs cover, Vent/Drain plugs) None (Direct mount) None (Direct mount) X IV Material (center body) 316 SST (Diaphragm: 316L SST) A V Process connections Rc 1/2 internal thread 1 1/2 NPT internal thread 2 1/2 NPT external thread 3 R 1/2 external thread 4 G 1/2 external thread 5 M20 1.5 external thread 7 VI Process installation Direct mounting F VII Bolt/nut None X Selection II I Electrical connection 1/2 NPT, Watertight A M20, Watertight * 2 B II Explosion proof [ ] * 3 None XX FM Explosionproof for Division system/flameproof for Zone system F1 FM Intrinsic safety F2 FM Nonincendive F5 Combination of code F1, F2, and F5 F6 ATEX Flameproof A1 ATEX Intrinsic safety A2 IECEx Flameproof E1 IECEx Intrinsic safety E2 NEPSI Flameproof N1 NEPSI Intrinsic safety N2 NEPSI Type n N5 KOSHA Flameproof * 4 K1 III Indicator None X With indicator * 5 A IV Paint Standard X None (316 stainless steel housing) E Corrosion-proof (Urethane) H V Failure alarm UP Scale A DOWN scale B None (for FOUNDATION Fieldbus) * 6 X VI Mounting bracket None X CF8 (L form) 1 *1. Not applicable for the combination with code Q1 Safety Transmitter of Option. *2. Not applicable for the combination with code F1 and F6 of Explosion-proof. *3. For FOUNDATION Fieldbus type. Refer to SS2-GTX00Z-0100. *4. Not applicable for combination with code E of paint. *5. In case the code C FOUNDATION Fieldbus communication of output is selected, code A2 of Option code should be selected. *6. Not applicable for the combination with code A 4 to 20 ma (SFN Communication), B 4 to 20 ma (HART Communication), and D Digital output (DE communication) of output. 7

Model GTX71G (High gauge pressure In-line model) Model No.: GTX G - Selection I (I II III IV V VI VII) - Selection II (I II III IV V VI) - Option Azbil Corporation Basic Model No. Measuring span 0.7 to 14 MPa (7 to 140 kgf/cm 2 ) GTX71G Selection I I Output 4 to 20 ma (SFN Communication) A 4 to 20 ma (HART Communication) B FOUNDATION Fieldbus communication C Digital output (DE communication) * 1 D II Fill fluid Regular type (Silicone oil) A For oxygen service (Fluorine oil) (not yet available) H III Material (Meterbody Meterbody cover Vent/Drain plugs cover, Vent/Drain plugs) None (Direct mount) None (Direct mount) X IV Material (center body) 316 SST (Diaphragm: 316L SST) A V Process connections Rc 1/2 internal thread 1 1/2 NPT internal thread 2 1/2 NPT external thread 3 R 1/2 external thread 4 G 1/2 external thread 5 M20 1.5 external thread 7 VI Process installation Direct mounting F VII Bolt/nut None X Selection II I Electrical connection 1/2 NPT, Watertight A M20, Watertight * 2 B II Explosion proof [ ] * 3 None XX FM Explosionproof for Division system/flameproof for Zone system F1 FM Intrinsic safety F2 FM Nonincendive F5 Combination of code F1, F2, and F5 F6 ATEX Flameproof A1 ATEX Intrinsic safety A2 IECEx Flameproof E1 IECEx Intrinsic safety E2 NEPSI Flameproof N1 NEPSI Intrinsic safety N2 NEPSI Type n N5 III Indicator None X With indicator * 5 A IV Paint Standard X None (316 stainless steel housing) E Corrosion-proof (Urethane) H V Failure alarm UP Scale A DOWN scale B None (for FOUNDATION Fieldbus) * 6 X VI Mounting bracket None X CF8 (L form) 1 *1. Not applicable for the combination with code Q1 Safety Transmitter of Option. *2. Not applicable for the combination with code F1 and F6 of Explosion-proof. *3. For FOUNDATION Fieldbus type. Refer to SS2-GTX00Z-0100. *4. Not applicable for combination with code E of paint. *5. In case the code C FOUNDATION Fieldbus communication of output is selected, code A2 of Option code should be selected. *6. Not applicable for the combination with code A 4 to 20 ma (SFN Communication), B 4 to 20 ma (HART Communication), and D Digital output (DE communication) of output. 8

Azbil Corporation Model No.: GTX G - Selection I (I II III IV V VI VII) - Selection II (I II III IV V VI) - Option Option No options With external Zero/Span adjustment (With external ZERO adjustment only for FOUNDATION Fieldbus) * 8 * 9 One elbow (left) * 3 * 4 * 7 One elbow (right) * 3 * 4 * 7 2 elbows * 3 * 5 * 7 G3 Oil and water free finish Oil free finish * 1 Au Plating Diaphragm 316 SST (Parts in contact with atmosphere) * 11 * 12 * 13 P8 Safety Transmitter * 2 * 9 * 14 (not yet available) Q2 NAMUR NE43 Compliant Output Signal Limits: 3.8 to 20.5 ma (Output 21.6 ma/selected upper limit, 3.6 ma/selected lower limit) * 9 * 14 Alarm Output (contact output) * 10 * 14 Q7 Advanced diagnostics * 15 Q8 Custom calibration R1 Test report T1 Mill certificate T2 Traceability certificate T4 NACE certificate * 6 T5 Non SI Unit W1 No. SS2-GTX00G-0200 *1. No need to select when Fill Fluid code H, or J is selected. *2. Not applicable for the combination with code A2, or Q7 of Option. *3. Not applicable for the combination with code A, or B of Process installation. *4. Not applicable for the combination with code F1, F6 of Explosion proof. *5. Not applicable for any Explosion proof. Please select code XX None of Explosion proof. *6. Applicable for ASTM B575, code B of Material (center body). *7. Not applicable for the combination with code B M20, Watertight electrical connection. *8. Not applicable for the combination with code X None of Indicator. Please select With indicator. *9. Not applicable for the combination with code D Digital output (DE communication) of output. *10. Not applicable for the combination with code F2, F5, F6, N2, N5, E2, and A2 of Explosion proof. *11. In case code P8 is selected, code D of Bolt/nut should be selected. *12. In case code P8 is selected, code E of Paint should be selected. *13. In case code P8 is selected, code X or 2 of Mounting bracket should be selected. *14. Not applicable for the combination with code C Digital output (FOUNDATION Fieldbus communication) of output. *15. Not applicable for the combination with code A 4 to 20 ma (SFN Communication), B 4 to 20 ma (HART Communication), and D Digital output (DE communication) of output. XX A2 G1 G2 K1 K3 L1 Q1 9

Azbil Corporation DIMENSIONS Unit: mm 96 Conduit entries 120 67 Field terminals Blanking plug 80 Meter (optional) 178 134 Atmospheric reference (do not face upward) Process connection 27 Process connection 1/2 NPT or Rc 1/2 20 3 3 5 17.5 M20 or G 1/2 20 5 1/2 NPT or Rc 1/2 TERMINAL CONNECTION (Not applicable for Fieldbus. See SS2-GTX00Z-0100 for Fieldbus.) Table 1: Terminal connection M4 External ground screw S+ S CHK/AL Symbol Details S+ Power supply and output signal + S Power supply and output signal /Check meter CHK/AL Check meter + Ground Table 2: Terminal connection (option Q7 : Alarm output) Symbol Details S+ Power supply and output signal + S Power supply and output signal CHK/AL Alarm + Ground/Alarm 10

Azbil Corporation Mounting to vertical 2 pipe No. SS2-GTX00G-0200 Unit: mm 2 pipe 142 (2) (1) (3) 102 141 85.5 Mounting to horizontal 2 pipe 206 (1) 2 pipe (3) (2) Mounting to wall 65.5 104.5 Bracket dimensions 12 58 5 5.5 hole 22 19.5 19.5 39 39 8 3.5 9 (1) 12 250 138 104 5 5.5 hole 4 (3) M5 bolt/nut* 104.5 71.5 69 8 112 12 69 22 19.5 19.5 3.5 9 39 39 8 2 5.5 hole 2 5.5 hole 4 69 Note) * Bolts for wall mounting are not included. (Length will vary according to wall thickness) 8 12 12 Materials of construction Key No. Description Material (1) Mounting bracket CF8 (2) U bolt/nut SUS304 (3) U bolt/nut SUS304 This drawing shows dimensions when optional mounting bracket is used, and shows typical mounting example. Other variations are also possible. 11

Azbil Corporation Please, read Terms and Conditions from following URL before the order and use. http://www.azbil.com/products/factory/order.html Specifications are subject to change without notice. 1-12-2 Kawana, Fujisawa Kanagawa 251-8522 Japan http://www.azbil.com/ (12) 12 1st edition: Aug. 2014 4th edition: June 2017 No part of this publication may be reproduced or duplicated without the prior written permission of Azbil Corporation.