Response Plus & Link Paging Systems Data Sheet

Similar documents
PRODUCT MANUAL VHF & UHF Pocket Paging Transmitter. Version 1.00 April 2017

On-site Wireless Paging System (POCSAG) Operation Manual. M-909X 8 individual buttons plus 1 group call button. M-916X 16 individual buttons

NetPage Network Wireless Paging System (POCSAG) NP-14 Series. Operation Manual CCW

Maintenance Manual. MTD SERIES 900 MHz, 10-WATT, DATA ONLY MOBILE RADIO. Mobile Communications LBI TABLE OF CONTENTS

ST600 TRANSMITTER OPERATING INSTRUCTIONS

GM339 & GM399 - Select V Mobile Radio Versatility & Sophistication on the Move

Videowave Wireless Video & Telemetry VTX1394SED & VRX1394SED

The wireless alternative to expensive cabling...

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

CP150 CP200. Commercial Series Two-Way Radios and Accessories. Seven Essential Elements of Solid Two-Way Communication

Applications: FM wireless audio, USB PC audio broadcasting, wireless microphones, maternal and child care.

SMARTALPHA RF TRANSCEIVER

TK-3301 PMR446 Transceiver - New ProTalk -

khz to 2.9 GHz Spectrum Analyzer

Guest Receiver INDEX INDEX. Guest Paging System... 1 Guest Receiver... 1 Desktop Transmitter...3. Transmitting Enhancement TX-125 series...

VBRC 5. Radio Communicator. Installer Manual

The wireless alternative to expensive cabling...

i2820h (USA) ie2820(europe)

Technical Equipment Specification

TK-272G/372G. Strength & Durability

Commercial Analogue Series VX-450, VX-4600 and VXR-9000

PDL Base. Radio Modem User's Guide. Revision 0.2 (preliminary) May 1999 Copyright 1999 Pacific Crest Corporation Document M00522

PSM1000. In-Ear Personal Monitoring Systems. PSM1000 In-Ear Personal Systems THE SOUND OF CONFIDENCE.

in all conditions, where safe communication is fundamental

OEM PRODUCTS WIRELESS WORLD LOCAL SOLUTION

UHF narrow band radio data module CDP-TX-04S-R 434 MHz /869 MHz

S O P H I S T I C A T E D A U T O M A T I O N

ISTATION-N (Integration Station) User Manual

Multi Agency Communications Center

TA-80. Digital Plug-on Transmitter

Synthesized Transmitter

PRX4SERL Four Zone Receiver Decoder

VHF AND UHF TRANSMITTER PRODUCT MANUAL. Version 1.01 August Copyright 2017 Sea Air and Land Communications Ltd. All rights reserved.

VisorTrac A Tracking System for Mining

VHF WIRELESS MICROPHONE SYSTEM

32 CHANNEL SELECTABLE CH MHZ DOWN VOLUME

Remote Radio Control. M880 WAVE2 C Transmitter Range. M880 for Low Integrity Stop Circuit Applications

Wireless Microphone Systems User Guide

The amazing evolution of the 706 series

Remote Switching. Remote Gates. Paging.

evolution wireless G4 ew 100 G4-ME2 ew 100 G4-ME4 Lavalier Set

PRODUCTS AND ACCESSORIES

Remote Switching. Remote Gates. Paging.

NC369 Paging Transmitter Installation Instructions

evolution wireless G4 ew 300 G4-Base SK-RC Bodypack Base Set

Analog and POCSAG digital radio pager tester PS 622 User Manual

CP 6632 Handheld process signal calibrator

KWM1900 Wireless microphone system

evolution wireless G4 ew IEM G4 Wireless Monitor Set

ADDENDUM 1. Bid# , Radio Interoperability System for the Sheriff's Office

Lifetime Power Energy Harvesting Development Kit for Wireless Sensors User s Manual - featuring PIC MCU with extreme Low Power (XLP) Technology

Handheld 3.3GHz Spectrum Analyzer

GPS Time and Frequency Reference Receiver

FM-RRFQ SERIES FM TRANSMITTER & RECEIVER HYBRID MODULES. Transmitter. Receiver. Applications

GV-700 VIBE PORT. Installation and. Operating Manual

GP329 PLUS AND GP339 PLUS PROFESSIONAL PORTABLE RADIOS

SWR TRUE Antenna Analyzer

BOOMERANG PAGING SYSTEM (RCL T800) Manual

Product Catalog: Europe

SRT PAGING & DATA RECEIVER MANUAL

Controls and Indicators

evolution wireless G4 ew 100 G4-835-S ew 100 G4-845-S ew 100 G4-865-S Vocal Set

DITCH WITCH ELECTRONIC GUIDANCE EQUIPMENT

Product Catalog: Europe

Digital Migration Radio PD6 Series

GM339/GM399. Conventional Select V Mobile Radio

TX4400 UHF CB RADIO INSTRUCTION MANUAL TX4400 INSTRUCTION MANUAL PAGE 1

TK-2312E TK-3312E. New Product Release Information. VHF FM Transceiver UHF FM Transceiver. March 2011

Preliminary Users Manual, Telex SAFE-1000 System.

SMR5000F. User Manual. Smart Radio Data Repeater. Web Site: P.N.: Book 092

PSM 900 Personal Monitor System. Personal Monitoring. Redefined.

evolution wireless G4 ew 300 G4-865-S Handheld Set

WMS 450 Wireless Microphone System

New Product Release Information TK-2406M TK-3406M2. VHF FM Transceiver UHF FM Transceiver. March SCHEDULE

UHF Narrow band radio data module CDP-TX-05M-R 426 MHz CDP-RX-05M-R 426 MHz

Motorola s Smallest Professional Radio. Compact, Easy to Use & Versatile. GP328 Plus & GP338 Plus Professional Portable Radios

The wireless alternative to expensive cabling...

DUAL BAND FM WIRELESS TRANSCEIVER RXQ1. Applications

PART E SPECIFICATIONS

DDS-PLL SYNTHESIZER DPL-2.5GF USER S MANUAL DIGITAL SIGNAL TECHNOLOGY, INC.

Alert Systems Product Catalogue. Version 08-1a

evolution wireless G4 ew 112 P G4 Camera Lavalier ME 2 Set ew 122 P G4 Camera Lavalier ME 4 Set

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz Operating Frequency Tolerance khz

MEMOCAL 2000/2000S. Hand-held calibrator

Digital Migration Radio PD605. DMR Standard Radio, Feature-Rich, Innovative Design, Compact Size, Integrates with Hytera Applications

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308

IC-F7000. Advanced selective call and ALE make HF communication easier than ever!

PDWM2800. Professional UHF Wireless Microphone System. with (2) Handheld Wireless Mics

Wireless LAN network. Wireless USB network

evolution wireless G4 ew 500 BOOM G4 Pro Camera Plug-on Transmitter set

Wireless systems.

Freedom Series UHF Synthesized Wireless Microphone System WRT-805A/807A/808A WRR-802A/805A MB-806A, WRU-806A

RF RECEIVER DECODER RDF1. Features Complete FM Receiver and Decoder. Applications

MODEL 640 DAPT XTRA. Dial Access Paging Terminals for Display and Voice Pagers

IntelPage 5W (POCSAG) Transmitter

evolution wireless G4 ew 512 P G4 Pro Camera Lavalier MKE 2 Set

Wireless LAN network. Wireless USB network

Digital Patrol Radio PD415

UHF Synthesized Wireless Microphone Systems WRT-805A/807A/808A WRR-802A/805A MB-806A, WRU-806A

Digital Patrol Radio PD412 Compliant with DMR standard Dual Mode Analog & Digital. Embedded RFID reader

Transcription:

Response Plus & Link Paging Systems Data Sheet The Response Paging System offers the latest innovations in wireless paging and monitoring. It s a cost effective and flexible system that provides the ability to quickly identify, validate and respond appropriately to activated alarms. Unnecessary evacuations have a significant impact on commerce and industry in terms of interrupted productivity, downtime and loss of revenue. They are also a considerable drain on the resources of the Fire and Rescue Services both in terms of lost time and costs. Save money and time by reducing evacuations through quickly identifying triggered alarms Improve response times by enabling personnel to identify the exact location of an alarm Sustain productivity, output and sales through the avoidance of unnecessary evacuations Enhance safety by improving the coordination of evacuations Build better relationships with the local fire authority Response Plus paging system has a wide range of applications that will fit all types of industries requiring a paging network. It can also be integrated with Notifier by Honeywell fire detection systems that immediately notifies designated fire marshals exactly where an alarm has been triggered, ensuring alarms can be identified and validated quickly, reducing time and costs associated with unnecessary evacuations. The Response Plus can be used to support four dry volt free contacts and serial data input. The contacts can be set to normally open N/O or normally closed N/C as required. When activated these will send pre-programmed messages to a particular pager address (which could be to an individual pager or group of pagers at the same time). Response Link is an entry level paging system suitable for a range of applications. It includes four dry contact alarm outputs that provide basic emergency information whilst offering the same paging capability. The Response Link supports four dry volt free contacts, which can be set to normally open N/O or normally closed N/C as required. This document is not intended to be used for installation purposes. Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. For more information, contact: NOTIFIER. Charles Avenue, Burgess Hill, West Sussex, RH15 9UF. United Kingdom Phone: +44 (0) 1444 230 300 Fax: +44 (0) 1444 230 888 Page 1 of 5-990-169_0912 ISO9001 Design, Manufacture and Supply to Quality Management Systems Certified to ISO9001:1994

Response Plus Paging System The Response Paging Systems consist of wall-mounted HIPS (High Impact Polystyrene) enclosure containing a transmitter enclosed in an aluminium surround. The units includes a 240-volt 3-pin plug, status indicator LED for Power and Transmission, and straight wire antenna, connected to the top of the enclosure using a 3/8 BNC bayonet connection. The Response Plus can be used to support four dry volt free contacts and serial data input. The contacts can be set to normally open N/O or normally closed N/C as required. When activated these will send pre-programmed messages to a particular pager address (which could be to an individual pager or group of pagers at the same time). Paging system consists of a wall-mount enclosure, power supply and transmitter Compatible with the Notifier serial protocol Status indicator LED for Power and Transmission 230V AC mains power supply with fused spur option An antenna (dipole) installed external to equipment enclosure RS232 data port input RS232 data port programming Four contact closure alarms Alphanumeric Pagers (supplied separately) Response Plus Paging System HLS RES PL Mechanical Specification Height 26.2 cm Width 15.5 cm Depth 5.0 cm Electrical Specification Power output 240v AC 500mW to 4W ±1dB 50 Ω Power usage Sleep: 40mA Transmit: 1.2A approx Frequency Range UHF: 427.5-475MHz, synthesized Channel Spacing 12.5kHz or 25kHz Baud Rate (Transmission) 512 or 1200 Baud Transmit Message Format POCSAG Message Length Up to 240 characters in total 4W System Connectivity Interface Serial connection Data Input Paging Protocols Environmental Operating Temperature Optional Additions (Technical approval required prior to order) Telephone interface 32 input dry contact expansion RS232 serial connection to Notifier Control Panel + 4 dry contacts 9600 Baud N:8:1 (for changing unit parameters and message output) Adjust for serial data input In addition to Notifier RS232 link, supports SALCOM, Scope, ESPA, Ascom -10 C to +60 C Page 2 of 5-990-169_0912

Response Link Paging System The Response Paging Systems consist of wall-mounted HIPS (High Impact Polystyrene) enclosure containing a transmitter enclosed in an aluminium surround. The units includes a 240-volt 3-pin plug, status indicator LED for Power and Transmission, and straight wire antenna, connected to the top of the enclosure using a 3/8 BNC bayonet connection. The Response Link is an entry level paging system that supports four dry volt free contacts, which can be set to normally open N/O or normally closed N/C as required. Paging system consists of a wall-mount enclosure, power supply and transmitter Compatible with the Notifier serial protocol Status indicator LED for Power and Transmission 230V AC mains power supply with fused spur option An antenna (dipole) installed external to equipment enclosure Four contact closure alarms Alphanumeric Pagers (supplied separately) Response Link Paging System HLS RES LI Mechanical Specification Height 26.2 cm Width 15.5 cm Depth 5.0 cm Electrical Specification Power output 240v AC 500mW Power usage Sleep: 40mA Transmit: 1.2A approx Frequency Range UHF: 427.5-475MHz, synthesized Channel Spacing 12.5kHz or 25kHz Baud Rate (Transmission) 512 or 1200 Baud Transmit Message Format POCSAG Message Length Up to 240 characters in total System Connectivity Interface Serial connection Environmental Operating Temperature 4 dry contacts 9600 Baud N:8:1 (for changing unit parameters and message output) -10 C to +60 C Page 3 of 5-990-169_0912

Response Pager The Response pagers are simple, compact and discreet personal devices for short messages. They re lightweight, comfortable to wear and come with a robust belt/pocket clip. Simple, compact and discreet personal device Durable, rugged and reliable Lightweight and comfortable to wear Easy to read alphanumeric text Protective case Bright backlight Easy to replace batteries Low battery indication Unread message indication Robust belt clip Display Screen protector Response Link Pager HLS-RES-PAGRD Frequency range 440-470Mhz Dimensions 75mm x 51mm x18mm Weight 65g (inc Battery) Display 12 Line x 18 alphanumeric English characters Memory Up to 60 messages Format POCSAG, FLEXTM AAA Battery Battery life 30 days without switching off Response Wrist Watch Pager The wrist watch pager allows users to respond to alerts quickly and easily with added comfort. The colour LED alphanumeric display can read up to 22 characters and includes alert modes: sound, vibrate and LED. Hand and PC programmable / USB ID programmer PLL or crystal, 137-930 MHz, POCSAG or Flex Alert modes: sound, vibrate, LED, silent 4 or 8 line English display, 3 zoom modes (English). Single colour or double colour Language support: Chinese, English, German, Korean, Turkish, Farsi, French Out of range, low battery, repeat message and unread message indicators Menu selectable, user choice special functions Second watch function Rechargable Li battery Response Link Wrist Watch Pager HLS-RES-PAGWA Frequency range 138-930 MHz Cap codes 8 Receiver type Synthesized or crystal Baud rate 512, 1200, 2400 bps Paging sensitivity -106dB @ 512 bps / -105DB@1200 bps/ -104dB @ 2400 bps Channel spacing 25 KHz or 12.5 KHz Frequency deviation +/- 4.5 KHz Frequency stability +/- 10 PPM Selectivity > 55dB Image rejection > 52db Spurious rejection > 52db Intermediation > 50db Alert tone volume 72dB+ @ 12 inch Weight 60g with battery Display 16 characters per line, 22 characters max. Dimensions 45mm x 46mm x 14mm Memory capacity Up to 19 messages (3000 characters) Battery type Rechargable Li battery Operating Temperature -10 C to 15 C Page 4 of 5-990-169_0912

Product Range at a Glance Part Number Response Plus Paging System HLS RES PL Response Link Paging System HLS RES LI Response System Survey Kit Response Plus Interface Unit additional 4 Contacts Response Plus Interface additional 32 Contacts Response Dipole Antenna with 5mtrs cable Response Programming Software & Cable HLS-RES-SK HLS-RES-INT4 HLS-RES-INT32 HLS-RES-ANT2 HLS-RES-COM Pager Red (For use with Link & Plus) HLS-RES-PAGRD Wrist Pager (Black) HLS-RES-PAGWA Response Radio Paging Licence (5 Years) HLS-RES-LICENCE Also available is Response Aid, which meets Equality Act 2010 recommendations for alerting the deaf and hard of hearing to fire alarms. Page 5 of 5-990-169_0912 Charles Avenue Burgess Hill W. Sussex RH15 9UF T: +44 (0) 116 246 2255 F: +44 (0) 116 246 2210 E: sales@notifierfiresystems.co.uk