FlashQuant Workstation The Best Way to Get the Right Answers... is in a Flash FlashQuant Workstation: Integrating MALDI Speed with Triple Quad Selectivity
5.03E+02 0.011 1.40E+03 2.680 5.26E+02 0.011 1.30E+03 2.700 6.23E+02 0.014 2.00E+03 3.400 3.49E+03 0.090 7.70E+03 21.90 6.25E+03 0.092 1.03E+04 22.30 Triple Quad Selectivity @ MALDI Speed Means Faster Discovery 6.72E+03 0.093 1.15E+04 22.70 4.62E+04 1.070 7.76E+04 261.0 5.21E+04 1.120 8.70E+04 271.0 4.99E+04 1.090 7.71E+04 263.0 2.56E+05 9.910 3.49E+05 2400 2.66E+05 10.400 3.95E+05 2520 2.50E+05 10.600 3.80E+05 2580 In the quest for faster discovery, the melding of innovative design, technology, and ideas is paramount, and that s exactly what the FlashQuant Workstation delivers. Specifically designed for high throughput early ADME workflows, the FlashQuant Workstation brings laboratories the ability to discover more potential drug candidates faster through increased analysis speed and data quality. The FlashQuant Workstation accelerates the quantitative analysis of pharmaceutical compounds by a factor of 25 and more, which leads to faster answers, faster decisions, and faster discovery. Now, labs no longer have to sacrifice speed for quality results, or sacrifice infinitely valuable time for one invaluable discovery. 2.50E+05 10.600 3.80E+05 2580 FlashQuant Workstation Innovative design for high throughput small molecule quantification. 5.03E+02 0.011 1.40E+03 2.680 5.26E+02 0.011 1.30E+03 2.700 6.23E+02 0.014 2.00E+03 3.400 3.49E+03 0.090 7.70E+03 21.90 6.25E+03 0.092 1.03E+04 22.30 4.62E+04 1.070 7.76E+04 261.0
Innovative Technology Leads to Innovative Discovery The FlashQuant Workstation combines a patented MALDI ion source with the industry standard triple quadrupole or Q TRAP MS/MS system for amazingly fast small molecule analysis. The MS/MS selectivity yields reliable, consistent quantitative results at incredible speeds. Being able to collect MRM data at Patented Q0 High Pressure Cell Unique, high-pressure collisional focusing technology maximizes ion transmission for enhanced sensitivity. s a m p l e s i n 5 m i n u t e s Patented LINAC Collision Cell With acquisition this fast, the need for proven high performance collision cell technology is essential. The patented LINAC collision cell accelerates ions through the collision quadrupole, ensuring maximum ion transfer at greatly reduced dwell times. Clear Advantages of Faster Answers, Faster Decisions, and Faster Discovery FlashQuant Software Get results fast with FlashQuant Software, expressly designed to quickly and easily set up and run 96 or 384 well plates. A single, elegant workspace displays the workflow, experimental parameters, and data associated with the targeted analytes. The easy-to-use software simplifies the quantitation experiment from sample analysis to report in 3 easy steps. very high rates becomes your significant advantage. 25x Optimized Ion Path For trusted quantitation, select either the pharmaceutical industry standard triple quadrupole or significantly Detector Reliable pulse-counting detector delivers superb linear response, wide dynamic range, and accurate results Standard Plate Formats SBS compliant 96 and 384 well plate a n d m o r e enhance qualitative performance with the 4000 Q TRAP ion path. day after day. formats supported for easy integration in standard workflows. Plate Stage With pump down in under 2 minutes, the The FlashQuant Software Manual Workspace allows users to ablate samples, acquire data, tune acquisition methods and visually inspect a plate. The Batch Workspace allows users to create, edit, or import batch definition files for running 96 or 384 well plate formats. accurate, fast-moving stage allows highspeed plate reading with high analytical precision for answers in a flash. Patented FlashLaser Source High repetition laser optimized for small molecule quantitative analysis delivers consistent results and the robust integration guarantees high uptime and >150,000 samples between cleanup. Once the data has been acquired, the MRM Quant Workspace clearly and concisely displays the quantitative information for the study. Change Over in a Flash The FlashQuant Workstation easily converts to operate with the Turbo V source. Once in this configuration, the workstation is also compatible with NanoSpray, PhotoSpray and DuoSpray sources.
Addressing the Compelling Need to Discover More Drugs Faster Streamlining the pharmaceutical development process while improving safety and efficacy is a goal of every pharmaceutical company. Faster, more thorough evaluations of New Chemical Entities (NCEs) assures proper selection of the most promising drug candidates in an effort to reach this goal. With amazing speed and accuracy, the FlashQuant Workstation rapidly runs through early ADME in vitro assays such as metabolic stability assays using liver microsomes and hepatocytes, drug permeability assays such as CaCO-2 and PAMPA, as well as CYP inhibition and induction assays, to achieve quantitative results that are beyond reproach. Intensity, cps 1.3 es 1.2 es 1.1 es 1.0 es 9.0 e4 8.0 e4 7.0 e4 6.0 e4 5.0 e4 4.0 e4 3.0 e4 2.0 e4 1.0 e4 0.0 0.890 0.895 0.900 0.905 0.910 0.915 0.920 0.925 0.930 0.935 0.940 0.945 0.950 0.955 0.960 Time, min Total runtime of 3 sec MRM traces: Propranolol Talinolol m/z 260 m/z 116 m/z 364 m/z 100 Area Ratio 5 4 3 2 1 0 area ratio 0.12 0.1 0.06 0.04 0.02 0 0 5 10 15 20 25 30 concentration (ng/ml) Concentration (ng/ml) y = 0.0041x + 0.0005 R 2 = 0.9997 0 200 400 600 800 1000 Linearity in a Flash Example of MRM signals from a set of four adjacent 1 µl spots of the same concentration (red trace is ISTD propranolol and blue trace is analyte talinolol). Calibration curve demonstrates 3 orders of magnitude linearity with excellent R 2 value of 0.9997. 2.1 e5 2.0 e5 1.9 e5 1.8 e5 1.7 e5 0.40 0.25 0.55 0.75 0.94 1.04 1.39 1.67 1.87 1.97 2.31 2.88 3.62 3.72 2.60 2.83 2.93 3.52 3.92 4.40 3.28 4.50 4.88 4.93 5.13 120.00% Buspirone 1.6 e5 Intensity, cps 1.5 e5 1.4 e5 1.3 e5 1.2 e5 1.1 e5 1.0 e5 9.0 e4 8.0 e4 7.0 e4 100.00% 80.00% 60.00% 40.00% LC-ESI/MS/MS MALDI-MS/MS 6.0 e4 5.0 e4 4.0 e4 20.00% 3.0 e4 2.0 e4 1.0 e4 0.00% 0 5 10 15 20 25 30 35 0.0 0.5 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Time Time, min Reproducible Quantitation in a Flash Reproducibility of 96 sample spots of buspirone at 50 nm concentration. The overall CV is less than 5% when using an internal standard and the total analysis time for 96 samples is approximately 5 minutes. Equivalent Answers in a Flash Microsomal incubation of buspirone at 0, 5, 15 and 30 minute time points. The samples were split and run by LC-ESI/MS/MS and the new FlashQuant Workstation (MALDI-MS/MS). Excellent correlation between the two techniques is observed. The most significant difference between the techniques is the time to complete the study; ~5 minutes for 96 samples by FlashQuant Workstation, and 1.6 hours by fast LC-ESI/MS/MS.
Discovery in a Flash You can rest assured, the FlashQuant Workstation delivers quantitation results you can trust to make confident decisions and reliability you expect from the leader in life science mass spectrometry. Let us show you how faster answers can speed up your discovery. Visit www.appliedbiosystems.com/flash CLASS 1 LASER PRODUCT For Research Use Only. Not for use in diagnostic procedures. Applera Corporation is committed to providing the world s leading technology and information for life scientists. Applera Corporation consists of the Applied Biosystems and Celera Genomics businesses. Applied Biosystems/MDS SCIEX is a joint venture between Applera Corporation and MDS Inc. Applied Biosystems, AB (Design) and Applera are registered trademarks of Applera Corporation or its subsidiaries in the U.S. and/or certain other countries. MDS and SCIEX are registered trademarks of MDS Inc. API 4000, FlashLaser, FlashQuant, Turbo V, and DuoSpray are trademarks and LINAC, Q TRAP, NanoSpray, and PhotoSpray are registered trademarks of Applied Biosystems/MDS SCIEX. All other trademarks are the sole property of their respective owners. 2007 Applera Corporation and MDS Inc. All Rights Reserved. Information subject to change without notice. Printed in the USA, 07/2007 Publication 114BR25-01 Headquarters 850 Lincoln Centre Drive Foster City, CA 94404 USA Phone 650.638.5800 Toll Free 800.345.5224 www.appliedbiosystems.com International Sales For our office locations please call the division headquarters or refer to our Web site at www.appliedbiosystems.com/about/offices.cfm