Model 30/L/0. Model 30/S/0. Shortl Blades, 0 Deflection 3/4" Spacing. Model 35/S/0 Short Blades, 0 Deflection 1/2" Spacing

Similar documents
GRILLE AND REGISTER OPTIONS AND ACCESSORIES

LINEAR DIFFUSERS AND BAR GRILLES


CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW

LINEAR GRILLES AND REGISTERS

LINEAR AIR GRILLE LF - 202/LF 212 / LF / LF ACCESSORIES

GRILLES AND REGISTERS

NOTES: Dimensions in parentheses are mm. For 1600 grille length and width dimensional information, see table on page K1-25.


INSTALLATION & OPERATION MANUAL ML-37 / ML-38 / ML-39 MLR-37 / MLR-38 / MLR-39. Redefine your comfort zone.

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

Document Number ODFD-XXX and OFD-XXX Series Installation Drawings for Out of Wall Curtain Fire Dampers

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

SCD, ASCD Square Cone Diffuser CM = CEILING MODULE CEILING OPENING D = DUCT SIZE. OD = D - 1/8" (3mm)

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

Technical Data VARIABLES

MANUAL INSTALLATION. Linear Bar Grille LBP. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

HALL 1 & HALL 4 RESTROOM FINISH UPGRADE 100 SOUTH WEST TEMPLE, SLC, UT QUOTE # SLP42848 AUGUST 29, 2017 CONSTRUCTION DOCUMENTS ABBREVIATIONS

SECTION AIR DISTRIBUTION SYSTEM

REQUEST FOR INFORMATION

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

METALWORKS TARTAN PANELS General Installation Instructions

Technical Development Program

INSTALLATION, I O OPERATION & MAINTENANCE M A N U A L. Flowline. Architectural Linear Diffusers

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

Mast Solutions Document/Installation Manual

REGISTERS, GRILLES & DIFFUSERS

FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L

IOM 005 Effective 1/13/18 Rev E A I R D I S T R I B U T I O N

Safety Glasses Work Gloves Chop Saw with Cutting Disk. Half Round File Pencil Marker

最終校 08_ スケール.indd 260

PENDANT MOUNT - DIRECT

baldwin 5" High, Solid Brass Solid Brass

FLOWLINE LINEAR DIFFUSERS

PEDESTAL INSTALLATION. Guidelines for installing adjustable height pedestals

ENR# Enlighted remote (5) WC# wireless control dimming. Specify quantity. Requires 8" blank See integrated controls guide for more details.

INTERIOR INSTALLATION

CEILING HI-OUTPUT. Project. Type. Notes

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation.

INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

WALL HI-OUTPUT. Project. Type. Notes

1x lm/ft - Maximum K

Siding Systems NOVIKSTONETM DS DRY STACK STONE INSTALLATION GUIDE

CEILING HI-OUTPUT. Project. Type. Notes

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

KCR-R CONSTANT AIR VOLUME FLOW REGULATOR

CIRCULAR VAV UNITS - CVA

Looking for a small band saw? The Ellis 1100 band saw might be just what you are looking for.

Architectural. 1 Paralum by Jean Nouvel

Lamp type 17 17W T8 (24") 14T5 14W T5 (22") 24T5HO 24W T5 (22") CF40 40W TT5 (24") CF50 50W TT5 (24")

SECTION MECHANICAL IDENTIFICATION

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K

IBD23 CURTAIN TYPE STATIC FIRE DAMPERS 3 HOUR UL555 RATED FOR USE IN STATIC SYSTEMS

JAMESTOWN175 SERIES Fixed, Projected and Casement Steel Windows

Inc. BT Series. BW Series

Wall mounting with holding profile

S.NO Description Quantity Rate Amount

Classic Exposed Tee System (24" x 24", 24" x 48", and 24" x 72") Floating Clouds and Perimeter Wall Attachment

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 27 = LED 2700K 30 = LED 3000K 35 = LED 3500K 40 = LED 4000K

REALLY EZ MAGNETIC DUCT SCRAPER TM

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

COLIBRI Ceiling. Square ceiling diffuser with discs for supply air QUICK FACTS

ORDERING INFORMATION:

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. International Version

metalworks Vector Assembly and Installation Instructions

PENDANT MOUNT - DIRECT/INDIRECT

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm mm

Catalog # Project. Comments. Prepared by. Warranty Five year warranty [38mm] 2.71" [69mm]

WALL MOUNT - DIRECT/INDIRECT. Project. Type. Notes

VISIONGUARD LOUVERS INSTALLATION MANUAL

finish AP alu. paint D custom UNV * *Please consult factory

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

COLIBRITM. Ceiling. Square ceiling diffuser with discs for supply air. Quick guide

21 C SHELVING SYSTEMS 21 C Shelving Systems consist of innovative products that provide visually appealing shelving and storage to any area. This syst

Product Selection Guide

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL

Fire Rating 3 hours- hollow metal doors mounted singly 90 minutes- hollow metal and composite core wood fire doors 20 minutes- wood doors

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

CHAPTER 6 DUCT SYSTEMS

GENERAL ISOMETRIC LAYOUT

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

Architectural Aluminum Frames

Built to Order. Stiles. StileLine. Steel Storefront. Features. Glass. Finishing. Section Contents

07 MECHANICAL 0746p IVR Natural ventilation and air grilles

Catalog # Project. Comments. Prepared by. Warranty Five year warranty. 51mm mm 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K

SECTION LOW PRESSURE DUCTWORK

PENDANT MOUNT ASYMMETRIC

Panel Installation Instructions

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 6 152mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

DA 22 Technical Specification

Frameless Fixed Panel Slider

Classics from Hart & Cooley is a decorator collection of high. quality registers, grilles and diffusers in classic designs and

NK / NL series. Rectangular VAV and CAV air volume control terminals

UNIVERSITY SERIES Fixed, Projected and Casement Steel Windows

Transcription:

model 30 / 35 - Steel Return Grilles & Registers 0 Deflection 0 fixed blade deflection maximizes free area for low pressure loss and sound levels Potential line of sight into duct thru grille is acceptable Model 30/S/0 using heavy, 20 gauge steel frames Aerodynamic blade design resulting in lowest achievable sound and pressure levels lades selected as horizontal or vertical for Model 30/L/0 Model 30/S/0 Shortl lades, 0 Deflection Model 35/S/0 Short lades, 0 Deflection Model 30/L/0 Long lades, 0 Deflection Model 35/L/0 Long lades, 0 Deflection Model 30 / S / 0 Model 35 / S / 0 0 Short lades Model 30 / L / 0 Model 35 / L / 0 0 Long lades NOM DUCT - 11/16 1-1/4 1 LADE VOLUME DAMPER 3-1/4-3

model 30 / 35 - Steel Return Grilles & Registers 45 Deflection 45 fixed blade deflection eliminates line of sight into ductwork Model 30/S/45 using heavy, 20 gauge steel frames NO SIGHT D E SIG N lades selected as horizontal or vertical for Model 30/L/45 Model 30/S/45 Shortl lades, 45 Deflection Model 35/S/45 Short lades, 45 Deflection Model 30/L/45 Long lades, 45 Deflection Model 35/L/45 Long lades, 45 Deflection Model 30 / S / D Model 35 / S / D 45 Vertical Louvers Model 30 / L / D Model 35 / L / D 45 Horizontal Louvers 1 1 1/4 NOM DUCT - 11/16 3-1/4 LADE VOLUME DAMPER -4

model 30 / 35 - Aluminum Return Grilles & Registers 0 Deflection 0 fixed blade deflection maximizes free area for low pressure loss and sound levels Potential line of sight into duct thru grille is acceptable Model 30/S/0 using corrosion resistant aluminum materials Aerodynamic blade design resulting in lowest achievable sound and pressure levels lades selected as horizontal or vertical for Model 30/L/0 Model 30/S/0 Shortl lades, 0 Deflection Model 35/S/0 Short lades, 0 Deflection Model 30/L/0 Long lades, 0 Deflection Model 35/L/0 Long lades, 0 Deflection Model 30 / S / 0 Model 35 / S / 0 0 Vertical Louvers Model 30 / L / 0 Model 35 / L / 0 0 Horizontal Louvers NOM DUCT - 11/16 1-11/32 1-3/8 LADE VOLUME DAMPER 3-5/8-5

model 30 / 35 - Aluminum Return Grilles & Registers 45 Deflection 45 fixed blade deflection eliminates line of sight into ductwork Model 30/S/45 using corrosion resistant aluminum materials NO SIGHT D E SIG N lades selected as horizontal or vertical for Model 30/L/45 Model 30/S/45 Shortl lades, 45 Deflection Model 35/S/45 Short lades, 45 Deflection Model 30/L/45 Long lades, 45 Deflection Model 35/L/45 Long lades, 45 Deflection Model 30 / S / 45 Model 35 / S / 45 45 Vertical Louvers Model 30 / L / 45 Model 35 / L / 45 45 Horizontal Louvers NOM DUCT - 15/16 1-11/32 1-3/8 3-5/8 LADE VOLUME DAMPER -6

model AC Lay-In Ceiling Return Grilles of room air Where reduced border width is preferred over larger surface frame 45 fixed blade deflection eliminates line of sight into ductwork. 0 straight blade maximizes core area Designed for use in conventional 15/16" inverted T-bar or 9/16" narrow slot type suspended ceiling grid systems Reduced order! registers exceeding the industry standard using heavy steel or extruded aluminum frames 1/2" or 3/4" blade spacing lades are parallel to long dimension opposed blade volume control damper satin polish finish volume control dampers Light shield for ceiling plenum return applications LAY-IN T-AR MODEL W/STEEL O W /ALUM. O Model AC30L-45 LAY-IN T-AR 9/16" NARROW SLOT 3/4" SPACING 1/2" SPACING 3/4" SPACING 1/2" SPACING 45 DEFL. 0 DEFL. 45 DEFL. 0 DEFL. 45 DEFL. 0 DEFL. 45 DEFL. 0 DEFL. AC30L-45 AC30L-0 AC35L-45 AC35L-0 AC30D-45 AC30D-0 AC35D-45 AC35D-0 AC30L-45-DS AC30L-0-DS AC35L-45-DS AC35L-45-DS AC30D-45-DS AC30D-0-DS AC35D-45-DS AC35D-0-DS AC30L-45-DA AC30L-0-DA AC35L-45-DA AC35L-45-DA AC30D-45-DA AC30D-0-DA AC35D-45-DA AC35D-0-DA MODULE SIZE MODEL SAC3LOD / XAC3LOD (Shown) = MODULE SIZE - 1 MODEL SAC3LOS / XAC3LOS (Shown) LADE DAMPER 3-3/4 OPEN 45 CORE 0 CORE 1-15/32 23/32 TYP. 3/4 TYP 3/4 TYP NOM MODULE SIZE - 1/4 AVAILALE MODULE SIZES 12 X 12 12 X 24 24 X 24 24 X 48 Note: lades are Parallel to Longer Dimension as Standard 9/16 NARROW SLOT SNAP-IN -8

model E30 Enhanced Capacity Returns 45 Deflection Enhanced blade design for high capacity applications Limited line of sight into duct is acceptable Typically surface installed in the side wall, duct, or ceiling Available in steel using heavy, 20 gauge steel frames, or corrosion resistant aluminum materials 45 fixed blade deflection, 3/4 spacing lades selected as horizontal or vertical for for supplied #8 x 1-1/2 oval head screws Aluminum opposed blade volume control dampers Model E30/L/45 Vertical lades, 45 Deflection Model E30/S/45 Horizontal lades, 45 Deflection -16