Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

Similar documents
READ THESE INSTRUCTIONS BEFORE YOU BEGIN INSTALLATION. Ground yourself before touching board. Some components are static sensitive.

Electro Controls. Input-Output Modules WattsIndustries.co.uk

CAP6637A AC-DC Open Loop Converter

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

Thornwood Drive Operating Manual: Two-SCR General Purpose Gate Firing Board FCRO2100 Revision H

B MTS Systems Corp., Model Function Generator

IO-DIM4 4-Channel, Digital to Analogue Converters

Know and understand you and your co-workers competence level before opening a live panel to diagnose

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

An Electronic Watt-Watt-Hour Meter

658 Current to Position Converters

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

With Audible Detect Signal

User s Manual for Integrator Short Pulse ISP16 10JUN2016

Overview. Features. Specifications. Important Notes

Rev.8.8 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2015 NUWAVE TECHNOLOGIES, INC.

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

2 Thermistor + Op-Amp + Relay = Sensor + Actuator

BC145 SIGNAL ISOLATOR BOARD

IF30. User's manual. Description. Table of contents IF30

DR3535 DR3535-O. Hardware Reference Manual. Document Revision A7 May 16, 2018 MICROKINETICS CORPORATION

DC Current Transducers

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

DynaDrive INFORMATION MANUAL SDFP(S)

Digital amplifier for proportional valves PEM XD

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

CAMTO. Arc detecting relay. system. January Revised August D D1200

Continental Hydraulics Installation Manual CEM-PA-A

ECM3 EARTH CONTINUITY RELAY

Application Solutions for: Analog (Input /

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

ScaleRCHelis.com Light Controller Users Manual

Design and Technology

Thornwood Drive Operating Manual: Six-SCR General Purpose Gate Firing Board FCOG6100 Revision R

Free Report By Humphrey Kimathi

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Microprocessor Control Board Set Up Procedures (OR PLC)

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

Anacon Power & Controls Relay Assembly Specialists An Anacon Electronic Sales, Inc. Company

Wireless Analog Output Modules

8 Channel, DMX to 0 10 volt, Decoder board

Continental Hydraulics Installation Manual CEM-RA-A

DPFHP451 HIGH PERFORMANCE BILEVEL STEP MOTOR / MANUAL PRESET INDEXER DRIVER PACK

OPERATING MANUAL FOR A 6-SCR GENERAL PURPOSE GATE FIRING BOARD, PART NO. FCOG6100 REV. J, J', J", K INTRODUCTION PRODUCT DESCRIPTION

EM-100 Controller. Installation Precautions. July 2016

Accessories Power Amplifiers

DC Voltage Hawk II H235 Series Advanced Digital Panel Meter

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

PHASE CUT SIGNAL DRIVERS

ALX-SSB 5 Band Filter Assembly Manual 19 November 2018

AC/DC ELECTRONICS LABORATORY

Analog Servo Drive 25A20DD

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Anacon Power & Controls

Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW)

354B SERIES SHAWNEE II High Speed Predetermining

VersaMax Mixed Discrete / High-Speed Counter Module

Blue Point Engineering

555 Morse Code Practice Oscillator Kit (draft 1.1)

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

1825 Duet Plus Installation Guide

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

Box chopper amplifier BOE

TEN-TEc INSTRUCTION SHEET MODEL KRS-A

TRIMLIGHT SELECT WIRING INSTRUCTION MANUAL

Proportional pressure controller

Contents. Warranty and Disclaimer 2

Pulse Scaler for DIN Rail Attachment

Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter

RT-5005/5006/5007/5008

MLA High Performance Microstepping Driver. User s Guide E. Landon Drive Anaheim, CA

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Breadboard Primer. Experience. Objective. No previous electronics experience is required.

AMC mA Positioner

DENISON HYDRAULICS Proportional Pressure Control Valves

1 Second Time Base From Crystal Oscillator

MODEL: D03128 CLAMP METER

33609/J Limiter/Compressor

CAT BOARD A CONTROL AND TRIGGER BOARD FOR 3-PHASE POWER SUPPLIES

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

Touchless Control: Hand Motion Triggered Light Timer

Pre-Laboratory Assignment

Series 354. SHAWNEE II High-Speed Digital Predetermining Counter. The 354B Directly Replaces 354A. COUNTERS PRODUCT HIGHLIGHTS

12V Dimmer Kit, version 2

AME140 Lab #2 INTRODUCTION TO ELECTRONIC TEST EQUIPMENT AND BASIC ELECTRONICS MEASUREMENTS

Installation, Operation and Maintenance Manual

Agilent 8761A/B Microwave Switches

VersaMax Mixed Discrete / High-Speed Counter Module

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Mini-Catalog of CONTROL INTERFACES. SIGNAL TRANSDUCERS and SIGNAL CONDITIONERS

MIC2287. Features. General Description. Applications. Typical Application. 1.2MHz PWM White LED Driver with OVP in 2mm 2mm MLF and Thin SOT-23

MOS FET Relay. Ordering Information. SSR for Switching Analog Signals, with an Insulation Value of 2.5 kvac between Input and Output Terminals

Transcription:

Product overview The AX-ROM135 and the AX-ROM1000 Modules enable an Analogue, Pulse or Floating point signal and convert to either a 0-135Ω or a 1KΩ Proportional Resistive output signal. The output resistance signal does not wrap around if the input signal exceed the highest or lowest selected input value. Both units are powered from 24Vac or 24Vdc, feature LED indication and are designed for mounting on TS35 section DIN rail. Three versions of the unit are available and must be selected at time of order. Features 135Ω & 1kΩ output versions (other values also) Analogue, pulse or floating point inputs 24Vac/dc powered DIN Rail mounting (TS35) High quality rising clamp terminals LED indication Product specifications Input Signal: Output: Power Supply: Power Consumption: Terminals: LED Indication: Ambient Temperature Range: Dimensions: Country of Origin: 8 Analogue (current/voltage) signal ranges 6 Selectable pulse input ranges 6 Selectable floating point ramp rates 135Ω and 1kΩ (Electrically isolated) 24Vac/dc 250mA max Rising clamp 0.5-2.5mm² cable ON when power on 0 to 50 C 120mm x 80mm x 25mm (approx.) U.S.A. Order codes AX-ROM135 AX-ROM1K 135Ω Resistance Output Module 1kΩ Resistance Output Module For all units, specify the following A B C D A = Beginning resistance value B = End resistance value C = Wattage D = Version 1, 2 or 4 (see page 2) Order Online at: www.annicom.com Email orders and enquiries to: Sales@annicom.com Issue 1.2 (21/03/14) Page 1 of 6

Requirements Input: Source Relay contact closure, transistor, or triac Trigger Level 4.5 to 30 volts DC, 10 to 26.4 volts AC Pulse Ranges: (Custom pulse ranges available also) Off Time 80 milliseconds minimum Version 1 0.02 to 5 seconds / 0.02 second increments 0.1 to 25.5 seconds / 0.1 second increments 0.59 to 2.93 seconds / 0.01 second increments Version 2 0.1 to 10 seconds 0.023 to 6 seconds Version 4 0-10 second Duty Cycle Pulse (samples in a 10 second window) Impedance 750 Ohms nominal Floating Point: (Custom rates of change available also) Rates of change Version #1: 30, 60 and 90 sec. Version #2: 45, 120 and 240 sec. Impedance 750 ohms nominal Analog: Ranges - Version 1 & 2 0-5Vdc or 1-5Vdc 0-15Vdc or 3-15Vdc 0-10Vdc or 2-10Vdc 0-20mA or 4-20mA Impedances Voltage 10,000 Ohms Output: Resolution Mechanical Requirements Relay Contacts: Type Rating Electrical Life Mechanical Life Current 250 Ohms STANDARD RESISTOR NETWORKS ROM - 0/135-3 watts (±5%) ROM - 0/1000-1/4 watt (±5%) STANDARD RESISTOR NETWORKS ROM - 0/270-3 watts (±5%) ROM - 0/500-1/4 watt (±5%) ROM - 0/1500-1/4 watt (±5%) ROM - 0/2K - 1/4 watt (±5%) ROM - 0/4K - 1/4 watt (±5%) ROM - 0/5K - 1/4 watt (±5%) ROM - 0/10K - 1/4 watt (±5%) ROM - 0/20K - 1/4 watt (±5%) ROM - 0/40K - 1/4 watt (±5%) 256 steps (no wrap around). Form C, Gold-clad Silver 2 amp max. Resistive @ 24V 100,000 operations 10 million operations Page 2 of 6

Page 3 of 6

Every effort has been taken in the production of this data sheet to ensure accuracy. Axio do not accept responsibility for any damage, expense, injury, loss or consequential loss resulting from any errors or omissions. Axio has a policy of continuous improvement and reserves the right to change this specification without notice. Page 4 of 6

Installation READ THESE INSTRUCTIONS BEFORE YOU BEGIN INSTALLATION. Ground yourself before touching board. Some components are static sensitive. MOUNTING: Circuit board may be mounted in any position. If circuit board slides out of snap track, a non-conductive stop may be required. Use only fingers to remove board from snap track. Slide out of snap track or push against side of snap track and life that side of the circuit board to remove. Do not flex board or use tools. POWER CONNECTIONS - THIS PRODUCT ACCEPTS 24VDC OR 24VAC POWER. Be sure to follow all local and electrical codes. Refer to wiring diagram for connection information. Be sure to make all connections with power off. 1. DC Power - Refer to wiring diagram for connection information. If the 24Vdc power is shared with devices that have coils such as relays, solenoids, or other inductors, each coil must have a MOV, DC Transorb, or diode placed across the coil or inductor. The cathode, or banded side of the DC Transorb or diode, connects to the positive side of the power supply. 2. AC Power - Refer to wiring diagram for connection information. Check the wiring configuration of any other loads that may be connected to this transformer. If requires by BAS or controller specification, the 24Vac neutral can be earth grounded at the transformer. Analog input, digital input, and analog output circuits should not be earth grounded at two points. Any field device connected to this transformer must use the same common. If you are not sure of other field device configuration, use separate transformers for isolation. If the 24Vac power is shared with devices that have coils such as relays, solenoids, or other inductors, each coil must have an MOV, AC Transorb, or other spike snubbing device across of the shared coils. Without these snubbers, coils produce very large voltage spikes when de-energizing that can cause malfunction or destruction of electronic circuits. Refer to wiring diagram for connection information. 3. You should measure the actual voltage output of the secondary. If the output is not fully loaded you may read a higher voltage than the circuit board can handle. CHECKOUT Version identification: Most AX-ROM s are shipped as version #1. An IC chip on the AX-ROM is labelled with the version program number. You may have to remove the resistor network card to view and compare to table on page 1. Resistor network: Each AX-ROM requires a plug-in resistor network card (RN) to operate properly. This resistance card determines the simulated slide wire potentiometer values for the output. Insert the RN (usually in a separate package from AX-ROM) into the AX-ROM. There are two rows of pins on the RN and two rows of female connectors on the AX-ROM. See page 1 drawing for proper RN orientation. The AX-ROM resistance output simulates a potentiometer. Terminal R is the wiper, B is the low end of the potentiometer and W is the high end. Upon power-up, the wiper will start at the B position and will remain there until the first PULSE or FLOATING POINT signal is received. The ANALOG version will begin tracking the input signal instantly after sampling the input signal to eliminate error. The output resistance will not change on the PULSE version until the end of the pulse. To check the resistance output, vary the input signal and measure the resistance. The resistance between terminals B and R will increase as the input signal increases and the resistance between W and R will decrease. If both floating point inputs are on for 3 seconds, the DRN3.1 resets to minimum resistance output. Setting the jumpers: Remove power from the AX-ROM. Place jumpers S1 through S6 in the appropriate positions. All six jumpers must be in proper position for each input type. Hold the AX-ROM with the label at top to orient its jumper shunts with the chart. Version #1 and Version #2 share the same analog inputs. Ramping time for floating point inputs are selectable. Version #4 accepts a continuous pulse signal command string within a 10 second window. No pulse in this 10 second window produces minimum percent output. A 10 second pulse in this 10 second window produces 100% output. Continuous pulse will produce maximum percent output. When power is restored, changes will be recognized. Apply 24Vac/dc to PWR terminals +24V and -, the FAIL-SAFE input terminals are closed ton the OUTPUT terminals. Check for continuity. When power is applied to terminals +24V and -, the POWER LED will light and the fail-safe terminals will be disconnected from the output terminals. Fail-back only occurs when the DRN3.1 has lost power. For fail-back to minimum resistance, add a jumper between B (minimum) and R (wiper) only. For fail-back to maximum resistance, add a jumper between W (maximum) and R (wiper) only. For fail-back to a specific resistance, a manual potentiometer or fixed resistors can be added between B (minimum) and R (wiper) only. Page 5 of 6

TESTING THE INPUT: Voltage input: Connect the + or positive wire to V/I+. Connect the common to 24V-. Apply a voltage from control source. Measure voltage at 24V- and V/I+ at terminal block. If the commanded voltage is not present, remove the + or positive wire and measure from + wire to 24V-. If no voltage is measures check the wiring from controller. If voltage disappears or is reduced when connected to the AX-ROM, confirm input jumper is set to voltage mode and remove signal input wires and power from unit. Measure the resistance from 24V- to V/I+. Resistance in the voltage modes will be around 10k. If input is shorted contact our Technical Support. If not shorted remove the controller input common and connect 24Vac/dc to the AX-ROM. Check for ground loop: Place meter in voltage mode and measure Vac and Vdc from analog input common wire to power supply common. If any voltage is measures in DC or AC a ground loop most likely exists. Check power commons and/or ground potentials. Use a separate 24 volt transformer for the AX-ROM and let common float. Current input: Confirm the input jumper is in the correct position. Measures input resistance should be around 250 Ohms. Connect + or positive to V/I+ and common or - to 24V- Apply ma signal. Place meter in voltage and measure voltage across V/I+ and 24V- 4mA is equal to 1 volt and 20mA is equal to 5V. Use Ohms law to find voltage from current. (Current x 250 = Volts. Sample: 13mA or 0.012 x 250 = 3 volts). If no voltage is present, check wiring for open. Current cannot exist without voltage present from V/I+ to 24V- unless dead shorted. Pulse Width Modulated (or PWM) input: Apply 24Vac/dc to the PWR terminals. Connect your meter to the to the R and B terminals on the output terminal block. Set meter to resistance range of resistor network. Connect a jumper wire from UP to the 24 + terminal. Connect a jumper wire to the 24 - only. You are now ready to simulate a timed pulse signal. For testing purposes, select.1 to 25.5 or 0.1-10 seconds on version 2. Be sure to reset power to allow the DRN3.1 to recognize new settings. Take the free end of the jumper wire from PWR - and connect by holding wire to the UP terminal. Count to 50% of timing range and remove. Verify the pulse UP LED indication. Voltage can be measures across the input to verify proper voltages. Read output. Has the output changed? The output should be close to 50% of set output. Floating Point/Tri-state: Apply 24Vac/dc to the PWR terminals. Connect your meter to the R and W terminals on the output terminal block. Set meter to resistance range of resistor network. Connect a jumper wire from Up to the 24 + terminal. Connect a jumper wire to the 24- only. You are now ready to simulate a timed pulse signal. For testing purposes, select the 30 or 45 second range on version 2. Be sure to reset power to allow the AX-ROM to recognize new settings. Take the free end of the jumper wire from PWR- and connect by holding wire to the UP terminal. Count to 50% of timing range and remove. Verify the pulse UP LED indication. Voltage can be measures across the input to verify proper voltages. Read output. Has the output changed? The output should be close to 50% of set output. Placing the wires on the DWN + and - terminals should decrease the output signal. Testing the output: Measures resistance from B to R terminals is the maximum resistance the RN can output. This measurement will not change. Measured resistance from W to R will increase proportionally to the command input value. A clicking sound will occur when resistance is changed. Resistance changes in steps. Resistance range divided by 256 will be the set size. Except for version 3 where step size is selected. Command a change or simulate an input signal to change the output. Measure the resistance value. If the resistance has not changed, check settings and reset power. Verify the input is functional. Most common problem: The analog input from the controller can contain electrical noise. This noise is seen by the AX-ROM as a change in commanded input signal and quickly changes the output. The most common symptom is a constant chatter of the relays Standard precautions should be taken to prevent noise on the signal input of the AX-ROM (i.e. Do not run signal wiring near line voltage wiring or fluorescent light fixtures). Versions 1 and 2 of the AX-ROM were modified in 2001 to add extra filtering to the input. Time response full scale is about 6 seconds. Check version number on your AX-ROM if high speed response or extra filtered version is required contact our sales department. TEST POINTS FOR RESISTOR NETWORK (RN) CARD The resistor Network card does not have to be attached to the AX-ROM motherboard for this test, but if attached to the AX-ROM, you must remove power before testing. Using an Ohm meter, test the last resistor as illustrated on page. The value indicated should be 1/2 the total resistance range of the Resistor Network card. Example: A 500 Ohm reading indicates a 0-1000 Ohm Resistor Network card. A 67.5 Ohm reading indicated a 0-135 Ohm Resistor Network card. Page 6 of 6