Dry Verge System. For more information on CEMEX visit

Similar documents
Installation guide for 20/20

manthorpe Roll-Out Dry Fix Ridge System building products Fixing Instructions MBP 8265e

Roll-Fix Kit The complete dry hip kit RFIG

REDLAND DRY VALLEY. Installation Instructions for Redland Dry Valley. Version: 6. Date: May Redland Technical Solutions

Sandtoft installation guides

Basic Fitting Details No. 1

technical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit

technical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit

Glidevale eaves ventilation

Glidevale eaves ventilation

technical datasheet Eaves Protector Stainless Steel Polytop Fixings 2 x 600mm Centres Eaves Protector

Insuvent Designed to ensure ventilation in existing roofs when insulation quilts are installed

BARRELL VAULT BATTENLESS

PROFESSIONAL PITCHED ROOFING ANCILLARIES

Barrel Vault Counter Batten and Batten

SANERI 3 º. Self-adhesive SBS-elastomer bitumen cap sheet

TECHNICAL BULLETIN 28

Continuous Dry-Verge, Dry Fix & Roofline Building Plastics

How many tiles can you see?

ROOFING DESIGN AND FIXING GUIDE

ONDUVILLA. The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S

2 Fibre cement slates fixing guide

CLIP RANGE & COMPATIBILITY TAKE A CLOSER LOOK. Part of BMI GROUP

Special Roofs and Vertical Slating

POCKET GUIDE TAKE A CLOSER LOOK TO COMPLETE REDLAND RANGE. Part of BRAAS MONIER BUILDING GROUP

ABOUT THIS GUIDE. April Clay plain tiles. fixing guide

GLOSSARY. A useful collection of definitions for commonly used terms in tile roofing.

Turada Hardwood Shingles and Shakes Installation instructions

BBA BRITISH BOARD OF AGREMENT CERTIFICATE NO. 87 / 1823 / C

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION

Technical Bulletin Fascia Installation Details

Shingle Installation Guidelines

video 10 YEAR GUARANTEE Durable and lightweight Guaranteed waterproof for 10 years Economical and easy to fix AVAILABLE IN A RANGE OF COLOURS

Inspire Aledora Slate Application Guidelines

Installation Guide. Guardian Slate Roof System. England, Scotland & Wales

CROSSBAR RAFTER ISOMETRIC

NEW equinox INSTALLATION GUIDE Issue

SmartVent Eave Edge Installation Instructions

50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated

Slate Shingle Specifications

Hard wearing and durable Quick and easy to install Fully adjustable for batten gauges of mm

Shingle Installation Guide

eco-shake INSTALLATION INSTRUCTION

Trapezoidal Roof KS1000 RW Installation Guide

15 YEAR GUARANTEE. Tough and long lasting Guaranteed waterproof for 15 years Economical and easy to fix AVAILABLE IN A RANGE OF COLOURS

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

BARDOLINE INSTALLATION INSTRUCTIONS

Tuff-Rib Install Guide

Fibre cement slates fixing guide

IKO0716 July Roofing Shingles. Selector & Fixing Guide

RED DIAMOND SHINGLES Roof Installation Introduction:

PROJECT INSTRUCTIONS Roofing

Installation Instructions

Five Star Panel Installation Instructions

Installation Manual. Future Roof Shingle / Slate Products

Three layer Felt Roofing using cold applied adhesive

This document is provided for guidance only, it is not intended to cover all local code variations.

1 Roof Substrate (Deck) OWENS CORNING BERKSHIRE SHINGLES INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Verge Flashing. Verge Flashing. Only use if flashings requirements can be site measured before ordering. Verge Clip

OWENS CORNING LAMINATE SHINGLES INSTALLATION INSTRUCTIONS

Installation Manual. Future Shingle Products

The Leka System Installation Guide

HOW TO Fix Onduline Corrugated Bitumen Sheets

EASY SLATE FIXING GUIDE

ZONAL FIXING METHOD USER GUIDE AND FIXING TABLES FOR FORTICRETE ROOF TILES

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE

Polytegola N. Bitumen Roof shingles. Application guide

Installation guide. Step-by-step instructions

Contents. Stage 1. Preparation of the aperture 9. Interior finishing 25

Installation Instructions

Lonsdale ThermGard Rafter Glazing Bars for conservatory roofs Introduction

ROOFING APPLICATION STANDARD (RAS) No. 130

ZIP System Roof Sheathing INSTALLATION MANUAL A REVOLUTION IN ROOFING

GV Standard PitchVent

ALPINE TRAY. To get the best from this product please follow these recommendations.

NEW equinox INSTALLATION GUIDE Issue

SECTION SLATE SHINGLES. 1.1 SUMMARY A. Section Includes: 1. Slate shingles over underlayment nailed to roof sheathing.

Ekoroof LiteTile Dimensions

Installer s Handbook. Pocket Guide to Roofline & Cladding Installation BBA BRITISH BUILDING PRODUCTS

AS TESTED TBA FIREFLY TBA FIREFLY BAL-FZ BUSHFIRE ROOF SYSTEM INSTALLATION GUIDE EASY TO INSTALL EASY TO CARRY EASY TO TRANSPORT

FOREWORD HARMONY TECHNICAL SPECIFICATIONS

The stylish light weight bitumen shingle tile strip roofing system Design and installation manual

SECTION 9: ROOF STRUCTURE, ROOFING MATERIALS AND FLASHING, GUTTER, DOWNSPOUTS, AND SKYLIGHTS. Background

DIRECTIONS FOR APPLICATION

Installation Guide. Please read before installing SIPs Kit. 1 Method Statement for the erection of a SIPS Industries Kit Materials...

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

Pitched roofs rafter level

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application

TYPICAL BARGE DETAIL - CROSS SECTION

Brava Old World Slate Installation Guide

Installation Instructions

SECTION WOOD SHINGLES

Knowledge of SCG Roof Installation

BBS Rusticated & Splaycut Cavity System

Stone coated steel roof tile INSTALLATION GUIDE

ROOFING City of Grand Rapids Building Safety Division

Transcription:

Dry Verge System The Russell Dry Verge System is a high quality purpose designed mechanically fixed and mortarless verge finish which requires no maintenance. It comprises of: Individual units for left or right hand verge. High quality grade PVC-u. PVC-u ridge end caps suitable for use with dry or bedded ridge. When used at top edge abutment, lead flashing to be dressed over the top of the verge unit, in accordance with L.S.A. guidelines. Suitable for normal batten gauges between 305mm and 345mm. Manufactured in brown, dark grey and terracotta to contrast or compliment any application. Can be fixed in all weather conditions. Maintenance free. No special tools required. Eliminates the need for wet mortar and undercloak. Sealing strip prevents the ingress of rain into the verge system. Standard Verge Unit gives neat attractive appearance, compatible with all Russell standard interlocking profiles. Thin Leading Edge, compatible with Galloway and Lothian tiles. Allows normal headlap variation. Interlocking feature prevents units from disengaging. Verge stop end prevents ingress of birds and vermin into the roof void. Maximum pitch 45 o, minimum pitch as recommended for tile profile. Components Standard Dry Verge Unit (RH) Thin Leading Edge (T.L.E) Dry Verge Unit (RH) Universal Angle Ridge End cap Dry Verge Eaves Stop End (RH) Half Round Ridge End Cap CEMEX Roof Tiles Nicolson Way, Wellington Road, Burton-on-Trent, Staffordshire, DE14 2AW Tel: 01283 517070 Fax: 01283 516290 www.cemex.co.uk

Cloaked Verge System The Russell Cloaked Verge System is designed to provide a mechanical dry, durable mortarless finish to the verge. Eliminates the need for mortar bedding and pointing. Components comply with BS EN 490 & 491 : 1994, BS 5534 : and BS 8000 : Maintenance free. Fast installation in all weather conditions. Attractive, neat uniform finish to the verge. Purpose made half tiles provide flexibility to allow setting out. Block End Ridges (either Universal Angle or Half Round) provide a neat weatherproof finish at the apex. Are available in colours and finishes to match Derwent, Double Roman and Pennine profiles to assist in setting out. Cloak Verge tiles are compatible for use with Russell Dry Fix Ridge Systems. Pennine Half Tile and Right Hand Cloak Verge Unit Derwent Half Tile and Right Hand Cloak Verge Unit Double Roman Half Tile and Right Hand Cloak Verge Unit Dimensions A A B B C D E Half Round Block End Ridge K L L K F Left Hand Cloak Verge Half Tile Right Hand Cloak Verge G H I F Double Roman Profile shown

Technical Data Installation Russell Cloak Verge tiles are quick and easily fitted by the roofing contractor. When setting out the roof, the verge overhang should be equal at both verges and should not exceed 50mm maximum. This can be readily achieved utilising half tiles. Where the distance from the inside face of the unit to the wall exceeds 12mm, a soffit closure strip is required to prevent the ingress of birds and vermin. Every cloak verge tile should be nailed with the same nail recommended for the standard tiles. Attractive weatherproof finish maintenance free. Maximum pitch 45 o. Site Work Preparation Carry out roofing underlay in the normal way, allowing approximately 38-50mm overhang beyond the brickwork/rendering. The outerskin of brickwork must be flush with the underside of the tiling battens. Battening Where rafter pitch exceeds 30 o and no batten end fixing is available (i.e. over brickwork), secondary battens (spanning minimum of two rafters) are necessary, to increase strength and rigidity. Gauge out the eaves course and establish the verge overhang, the distance from the inner face of the cloak verge tiles to the brickwork/render should not exceed 12mm without a soffit closure strip being fitted. Setting Out During setting out it may not be possible to achieve a flush fit by shunting of the tiles, it will therefore be necessary to introduce half tiles, either next to the cloak tiles or elsewhere in the tiling in order to maintain bond throughout. Laying Cloak Verge Tiles Start tiling from the right hand verge, allowing approx. 38-50mm overhang. Lay the main tiles in the normal manner from right to left. Fit purpose made half round block end ridge tiles at either end of ridge, either mortar bedded or dry ridge fix system. Derwent Double Roman Pennine A 120 120 120 B 420 420 420 C 375 365 350 D 180 180 180 E 335 335 335 F G H 145 145 145 I 320 315 310 J 75 120 110 K 23 23 23 L 35 35 35 This table is to be read in conjunction with the previous page Approx. dimensions in mm

Dry Hip System Recommended Specification The Russell Dry Hip System is designed to provide a mechanically fixed, neat and attractive finish to the hip line without the use of mortar. It is suitable for use with all of the Russell smooth finish interlocking tile range. Usable on roof slopes up to a maximum of 45 0 pitch and where the hip eaves intersection is 90 0 on plan. The system is available in 3m packs either: a) To suit flat tiles and slates b) To suit profiled tiles Can be fitted in all dry weather conditions. Purpose designed block end hip tiles, to finish off the base of the hip with a pleasant appearance and secure mechanical fixing. Available in either: a) Universal Angle b) Third Round A Dry Hip Pack Comprises Hip Tile Support Strips Hip Joint Gasket 100mm S/S Nails 115mm S/S Nails Hip Batten Spacers Hip Roll Hip Batten Connector 4No 1No Hip end tiles are available to order separately.

Dry Hip System For Flat Tiles The componenets Universal Angle jointing gasket with 115mm S/S nail and washer Hip Batten Spacer Hip Roll (Not to scale) Hip Tile support strip (1.6m) 450mm Hip batten connector 100mm Stainless Steel annular ring shank nail Universal angle hip end tile

Dry Hip System The componenets Hip Batten Spacer Half round jointing gasket with 115mm S/S nail and washer Hip Roll (Not to scale) Hip Tile support strip (1.6m) 450mm Hip batten connector 100mm Stainless Steel annular ring shank nail

Fixing Instructions Datasheet Dry Ventilation Ridge System 1 2 3 Position the centre legs of the Ridge Batten Connectors to suit the rafter angle. Secure to each rafter with 2 nails through the holes provided. Position and secure the top tile battens. Place a 50mm square ridge batten across the Ridge Batten Connectors. Fold up the 4 arms of each Ridge Batten Connector, tightly fold over and secure with clout felt nails. 4 5 6 Position the Vent Flow Units along the Ridge Batten and secure the overlaps with felt nails. NOTE: Ensure that the underlay is turned up the Vent Flow Unit, but does not obstruct the airflow path. (See cross section detail). Lay the roof tiles in the normal manner. Position the ridge tile with the Ventilator Strip and pre-assembled Profile Fillers each side of the ridge. Where a Dry Verge System is used the Ventilator Strip should overlap the Dry Verge Unit while the Profile Filler should be cut to butt with its edge. (Inset) 7 8 Locate the Jointing Gasket on the end of the ridge tile and position the next ridge tile. Secure with the s/s ring shank nail 100 x 3.75mm and neoprene washer provided. Subsequent Ventilator Strips should be connected using the spare Profile Fillers. (Inset) Finish off the ridge ends with a suitable ridge capping system. Where a Dry Verge System is used the Ridge End Cap should be secured in the recommended manner. CEMEX Roof Tiles Nicolson Way, Wellington Road, Burton-upon-Trent, Staffordshire DE14 2AW Tel: 01283 517 070 Fax: 01283 516 290 www.cemex.co.uk/russell

Fixing Instructions Datasheet Dry Ventilation Ridge System 1 Figures in () are for the number of items supplied in a 3m pack. CEMEX Roof Tiles Nicolson Way, Wellington Road, Burton-upon-Trent, Staffordshire DE14 2AW Tel: 01283 517 070 Fax: 01283 516 290 www.cemex.co.uk/russell

Dry Valley The dry valley system provides a maintenance free means of discharging water from the roof and is suitable for use with interlocking and profiled tiles. The product is supplied in 3m lengths 80mm or 105mm high dependant on tile profile being used.