EXHIBIT/BOOTH SPECIFICATIONS

Similar documents
Booth Display Rules. Standard Inline booth. Perimeter booth. Island booth. Peninsula Booth

EXHIBIT DISPLAY REGULATIONS LINEAR BOOTH April Orange County Conven on Center Orlando, Florida

EXHBIT DISPLAY REGULATIONS End-Cap Booth

BOOTH CONSTRUCTION & DISPLAY REQUIREMENTS Huntington Convention Center Cleveland, Ohio February 7 9, 2018

A. STANDARD BOOTH. DEFINTION One or more standard units in a straight line.

A. STANDARD BOOTH. DEFINTION One or more standard units in a straight line.

Exhibit Space & Booth Layout Guidelines

A. STANDARD BOOTH. DEFINITION One or more standard units in a straight line

Exhibit Design Regulations

Exhibit Display Rules and Regulations

Exhibit Design Regulations

The maximum back wall height is eight-feet three-inches (8 3 ), including truss, and is allowed only in the rear half of the booth space.

Exhibit & Signage Rules

Exhibit & Signage Guidelines

2018 NAMM Show - Booth Display Types & Regulations

Guidelines for Booth Display/ Rules & Regulations

Guidelines for Display Rules & Regulations

Island and Peninsula Booths under a Skywalk may build up to 16 * Inline/Linear Booths may build up to 8 *

THE INTERNATIONAL WORKBOAT SHOW

DISPLAY RULES AND REGULATIONS

DISPLAY REGULATIONS PAGE 1 OF 6

EXHIBIT DISPLAY GUIDELINES

THE SHOW. Guidelines for Booth Display/ Rules & Regulations

Made possible by a generous grant from. Guidelines for Display Rules & Regulations 2014 Update

Corner Exhibits A Corner Booth is a Linear Booth ( In-Line ) exposed to aisles on two sides. All other guidelines for Linear Booths apply.

Exhibit Display Rules and Regulations

REVISED DISPLAY RULES & REGULATIONS

General Display Rules

Guidelines for Display Rules and Regulations

Index. Linear Booth, Corner Booth and Perimeter Booth 2. End-cap Booth and Peninsula Booth 3. Split Island Booth and Island Booth 4

Display Rules & Regulations

NACS Show Booth Display Guidelines

Made possible by a generous grant from. Guidelines for Display Rules & Regulations 2014 Update

Guidelines for Display Rules & Regulations 2014 Update

Guidelines for Display Rules and Regulations

Booth Construction and Layout

IAEE Booth Display Rules & Regulations

Exhibit Space & Booth Layout Guidelines

Booth Construction and Layout

2018 NRA Annual Meetings & Exhibits. Display Rules & Regulations

BOOTH RULES & REGULATIONS

BOOTH REGULATION VISUALS

You are not allowed to install or place anything above the maximum height allocated for each type of booth.

Linear Booth. Corner Booth

Exhibit Space & Booth Layout Guidelines

Guidelines for Display Rules & Regulations 2014 Update

Made possible by a generous grant from. Guidelines for Display Rules & Regulations 2014 Update

Guidelines Update. For Display Rules and Regulations 3.5' 3.5' 3.5' 12' 1.75' 20'

DISPLAY/BOOTH RULES AND REGULATIONS

NRF BOOTH GUIDELINES

Guidelines for Display Rules & Regulations 2007 Update

Guidelines for Display Rules & Regulations 2014 Update

Guidelines for Display Rules & Regulations 2005 Update. made possible by a generous grant from Champion Exposition Services

Exhibit Space & Booth Layout Guidelines

Exhibitor Guidelines for Booth Display Rules and Regulations

Linear Booth. Corner Booth (3.048M) 10' (1.524M) (1.524M) 5' (1.524M) (3.048M) 10' (1.219M) PLAN VIEW LEFT SIDE VIEW (2.438M) (1.

EXHIBITOR RULES for AFP 2018 (Effective 02Aug2017)

Guidelines for Display Rules & Regulations 2014 Update

September 29 October 1, 2013 Indiana Convention Center 100 South Capitol, Indianapolis, Indiana 46225

Guidelines For Display Rules And Regulations

Booth Construction. Installation & Dismantle. AAO 2016 Exhibit Prospectus

NEW BOOTH PACKAGE SPECS + DECOR RULES

Exhibit Space & Booth Layout Guidelines

Exhibit Space & Booth Layout Guidelines

Booth Design Guidelines

Exhibit Space & Booth Display Guidelines

Booth Design Guidelines

NON-EXHIBITOR/Business MEMBERSHIP

EXHIBITOR MANUAL North Carolina State Fairgrounds

TBA BUSINESS MEMBER BENEFITS MEMBERSHIP INFORMATION

Stand construction regulations

General Rules. of the needs exhibitions. Every. have. management for booth. Flooring in. your exhibit. are not. contracted. from view in.

Appendix G - Booth Rules and Regulations

All exhibits must have floor covering (wall-to-wall carpeting or other flooring), with no concrete floor exposed.

Example. *Please see the MODEX 2018 Rules and Regulations (attached) for full details on all rules and regulations.*

digital graphics page 1 of 1

EXHIBIT RULES & REGULATIONS

GHC 18. Sponsor Expo Webinar. June 27, 2018

Historic Preservation DESIGN GUIDELINES

Tenant Sign Criteria. Guidelines. Requirements. Braelinn Village, Peachtree City

2015 Exhibitor Handbook. This handbook including the attached booth rules are binding parts of the exhibitor agreement.

2016 Exhibitor Handbook. This document including the attached booth rules are binding parts of the Exhibitor Agreement.

2018 Exhibitor Handbook. This document and the attached booth rules are binding parts of the Exhibitor Agreement.

SUNSET & FRANCISQUITO SHOPPING CENTER S I G N P R O G R A M

Construction Guidelines 1

2018 FUNERAL DIRECTORS CONVENTION AND EXPO EXHIBITOR RENTAL APPLICATION AND CONTRACT

KAY BAILEY HUTCHISON CONVENTION CENTER MAY 3-5, 2019

Exhibitor Prospectus. Cardinal Health Retail Business Conference

OPERATING GUIDELINES Toronto Comicon

SIGN PERMIT APPLICATION

Estimated Cost of Project Contractor License No. Contractor Qualifier No.

OPERATING GUIDELINES Toronto Comicon

DRAFT V. SITE ELEMENTS SIGNS

70% 26% HOW DOES ATMAE HELP ME? WHO ATTENDS OUR MEETINGS Annual Conference Sponsorship and Exhibitor Opportunities

COMMERCIAL KITCHEN HOOD WORKSHEET/ CHECKLIST

APPENDIX 3-CLASSROOMS (review by MB) General Guidelines- All Classrooms

UNIQUE KIOSK SITE INSPECTION FORM

CITY OF MERCER ISLAND DEVELOPMENT SERVICES GROUP 9611 SE 36 th Street, Mercer Island, WA (206)

DOUGLAS COUNTY ZONING RESOLUTION Section 30 Lighting Standards 3/10/99. -Section Contents-

SECTION EMERGENCY RESPONDER RADIO COVERAGE SYSTEMS

Transcription:

BOOTHS ALL BOOTHS 10 WIDE X 10 DEEP UNLESS OTHERWISE NOTED. AISLES ALL AISLES 10 WIDE. MAIN AISLES 15 20 WIDE. CEILING HEIGHTS NORTH HALL AISLES N100-N1700 33 * AISLES N1800-N3200 35 * CENTRAL HALL AISLES C4000-C4600 25 ** AISLES C4800 31 *** AISLES C5100-C7800 35 AISLES C3400-C3900 25 SOUTH HALL, LEVEL 1 AISLES S10000-S12200 25 AISLE S12300 (EVEN NUMBERED BOOTHS) 25 AISLE S12300 (ODD NUMBERED BOOTHS) 30 AISLES S12400-S15100 30 *THE NORTH HALL HAS LOWER CEILING HEIGHTS IN SEVERAL AREAS; SEE FLOOR PLAN FOR SPECIFICS. **PORTIONS OF BOOTHS IN THE C4600 AISLE HAVE A CEILING HEIGHT OF 21 6. ***PORTIONS OF BOOTHS C4881 AND C4981 HAVE A CEILING HEIGHT OF 15. UTILITIES ELECTRICITY, GAS, COMPRESSED AIR, WATER AND TELEPHONES ARE AVAILABLE. ALL UTILITIES COME FROM OVERHEAD AT THE LAS VEGAS CONVENTION CENTER, EXCEPT IN THE SOUTH HALL, ELECTRICITY AND TELEPHONE SERVICES COME FROM THE COLUMNS. FLOORLOAD UNLIMITED NORTH HALL, CENTRAL HALL *, SOUTH HALL, LEVEL 1 *EXCEPT FOR AISLES C4800-C4900, WHICH HAVE A 175 LBS/SQ FT MAXIMUM WEIGHT LOAD

BOOTH SPECIFICATIONS PLEASE REVIEW THE FOLLOWING BOOTH SPECIFICATIONS TO ENSURE THAT YOUR DISPLAY MEETS THE EXHIBIT/BOOTH GUIDELINES. ALL BOOTHS, REGARDLESS OF SIZE, ARE REQUIRED TO FOLLOW THESE GUIDELINES. FOR QUESTIONS REGARDING BOOTH SPECIFICATIONS, PLEASE CONTACT SHOW MANAGEMENT AT 866-962-7469 OR OPERATIONS@WORLDOFCONCRETE.COM. BOOTH EQUIPMENT Standard 10 x 10 Linear Booths will be set with 8 3 high black back drape and 3 high black side drape. All booths MUST have a professionally finished floor covering. LINEAR (IN-LINE) BOOTHS Definition: Linear Booths have at least one side exposed to an aisle and have at least one adjacent neighbor on either side of the booth. Booths are typically 10 wide and 10 deep. In the back 5 section, display material, signage, equipment and product may not exceed 12 in overall height. Any display material, signage, equipment and product over 8 3 must be professionally finished or draped on the back. Show Management will determine what is considered professionally finished. Exhibitor may be required to order drape to cover unapproved back wall. Signs, banners, logos, images, symbols or flags (including those manufactured on the product or equipment) are not permitted on the backside of the back wall or sidewall at any height. In the front 5 section, equipment, product, display material and signage may not exceed 4 in overall height. Please reference the diagram of allowable configurations. No signs or truss work hung from the ceiling are allowed in linear booths. Note: When three or more Linear Booths are used as a single exhibit space, the 4 height limitation in the front of the booth is applied only to that portion of exhibit space, which is within 10 of an adjoining booth. 12 maximum height for display material, signs, back wall and sidewalls, equipment and product; no signage permitted on the back side of the back wall or sidewalls at any height, backside over 8 3 must be professionally finished or draped. 4 maximum height for equipment, product, display material, signs and sidewall 10 X 10 or 10 X 20 BOOTHS 5 feet 5 feet Back wall (plan view) 10 X 30 and LARGER BOOTHS Back wall (plan view) 5 feet 5 feet

PERIMETER LINEAR BOOTH Definition: A Perimeter Booth is a Linear Booth that backs to a wall of the facility rather than another exhibit booth. All guidelines for a Linear Booth apply to a Perimeter Booth except that the maximum back wall and sidewall height allowed in the back 5 section is 16 for display material, signage, equipment and product. This includes signs, banners, logos, images, symbols or flags. No signs or truss work hung from the ceiling are allowed in perimeter booths. PENINSULA BOOTHS Definition: Peninsula Booths are exposed to aisles on three (3) sides and are backed by linear booths. Peninsula Booths are 20 wide by 20 deep or greater. The same principles apply regardless of booth size. Display material, signage (including hanging signs), sidewalls and back wall will be permitted up to a maximum height of 26 when ceiling height permits; except in the 5 section on each side of the back wall which has a 4 maximum height for equipment, product, display material, signs, sidewall and back wall. Unlimited height for equipment and product is permitted throughout the allowable booth space. Please reference the diagram of allowable configurations. No signage (including hanging signs) is permitted on the backside of the back wall at any height. Hanging signs must be placed at least 5 from the back wall. Unlimited height for equipment and product; 26-ft. maximum height for display material, signs, back wall and sidewall (when ceiling height permits); no signage (including hanging signs) permitted on the backside of the back wall at any height; hanging signs must be at least 5 from the back wall 5 Min. Back wall (plan view) 5 Min. 4-ft. maximum height for equipment, product, display material, signs, back wall and sidewall

ISLAND BOOTHS Definition: An Island Booth is any 20 wide by 20 deep or greater booth exposed to aisles on all four sides of the booth. Display material and signage (including hanging signs) will be permitted up to a maximum height of 26 when ceiling height permits. Unlimited height for equipment and product is permitted throughout the booth.

HANGING SIGNS Hanging signs are defined as banners, logos, images, symbols and flags. Hanging signs and truss work hung from the ceiling are not permitted in linear and perimeter booths. Hanging signs will be permitted in the following booth configurations to a maximum height (dependent on ceiling height in exhibit hall)of: Peninsula Booth: 26 maximum from floor to top of sign Island Booth: 26 maximum from floor to top of sign - ALL hanging signs must be a minimum of 9 off the floor (from the floor to the bottom of the sign). Signs may be hung from the ceiling (where permitted), truss work or equipment. Signs that will be hung from the ceiling or truss work must be installed and dismantled by Freeman. HANGING SIGNS FROM EQUIPMENT Hanging signs from equipment must conform to the height limitations above. Freeman must approve rigging of signs that weigh over 250 pounds and are hung by the exhibitor or Exhibitor Appointed Contractor. For questions on hanging signs, please call Freeman Decorating at 702-579-1700. LIGHTING Lighting (including lasers) must be contained within the confines of the booth and must not wash into aisles or other booths. Strobe lights that are not sold as product by the exhibiting company are prohibited. Note: Las Vegas Convention Center has specific rules on the use of halogen lights. Please reference the Exhibitor Service Manual for full details. SOUND/MUSIC Sound of any kind may not be projected outside the confines of the booth. Show Management reserves the right to determine if sound constitutes interference and must be discontinued. DEMONSTRATIONS When conducting demonstrations or presentations, all activity and viewers must be contained within the booth and all aisles must remain clear. To prevent gatherings in an aisle, demonstrations cannot be conducted on any edge of the booth along an aisle.

TENTS, AWNINGS, CANOPIES Covered or canopied booths require approval by show management. Exhibitors must submit structural approved plans and a Certificate of Insurance with the coverages outlined in Clause 25 of the Exhibitor Contract. Covered areas will be required to have approved battery-powered smoke detectors which emit alarms audible outside of the enclosed or covered area. There must be fire extinguishers, minimum class 2A10BC*, in each enclosed area. There shall be a locally approved Fire Watch for enclosures larger than 300 square feet (92.9 sq. m). All multi-story exhibits and covered/canopied booths are required to submit structural engineered certified plans to Show Management (tyler.johnson@informa.com) and the LVCC (boothplans@lvcva.com) for approval. A Certificate of Insurance with the coverages outlined under Clause 25 of the Exhibitor Contract should also be included. Written requests must be submitted at least two months prior to move-in and must include detailed plans showing size, height, location, anchoring detail, and certification of flame retardant for all materials. Exhibitors using canopies or false ceilings over their exhibit may use vertical supports up to 3 inches in width in the corners of their space. Vertical supports that are strictly decorative will not be permitted.