ENDUREED VIVA SERIES Specifications

Similar documents
SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

Slate Shingle Specifications

B. Related Sections: The following Sections contain requirements that relate to this Section:

1.04 QUALITY ASSURANCE

AIA Specification. Section Slate Shingles PART 1 GENERAL

SECTION ASPHALT SHINGLES

SECTION SLATE SHINGLES. 1.1 SUMMARY A. Section Includes: 1. Slate shingles over underlayment nailed to roof sheathing.

RESIDENTIAL ROOFS ADDENDUM NUMBER ONE. August 28, 2017

4. Metal roof jacks at penetrations and attachments

eco-shake INSTALLATION INSTRUCTION

SECTION ASPHALT SHINGLES

SECTION WOOD SHINGLES

PROJECT INSTRUCTIONS Roofing

ESR-1129 Reissued June 1, 2011 This report is subject to renewal in two years.

Ash Brook Golf Course Scotch Plains, New Jersey

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

SECTION LAP SIDING. A. Fiber cement lap siding, panels, single, trim, fascia, moulding and accessories.

Inspire Aledora Slate Application Guidelines

Asphalt Shingle Installation at Roof Edges, Intersections and Valleys

ROOFING City of Grand Rapids Building Safety Division

DIRECTIONS FOR APPLICATION

SECTION ASPHALT SHINGLES

A P P L I C A T I O N I N S T R U C T I O N S

DIRECTIONS FOR APPLICATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: IKO INDUSTRIES LIMITED

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

Viva Synthetic Thatch Installation Instructions

DIRECTIONS FOR APPLICATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER:

b) Symphony comes pre-packaged in color and width blends. There is no need to mix Symphony at the job site. Currently Symphony is available in the

B. Terracotta Precast Facade Assembly consisting of single-leaf, through body color terracotta clay tiles.

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

Turada Hardwood Shingles and Shakes Installation instructions

RED DIAMOND SHINGLES Roof Installation Introduction:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT

Timberline and Sovereign Expanded Fastener Placement Area

SECTION SHEET METAL FLASHING AND TRIM

DIVISION 6 WOOD AND PLASTICS

1. Section : Rough Carpentry 2. Section : Exterior Insulation and Finishing Systems 3. Section : Metal Roof Panels

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

INTEX Millwork Solutions SECTION EXTERIOR PVC PERGOLAS (IBC Compliant)

Copyright 2010 AIA MasterSpec Premium 08/10 PRODUCT MASTERSPEC LICENSED BY ARCOM TO TRA SNOW AND SUN.

Installation Guide. Cedar Shake. Distributed by: BEST MATERIALS LLC, Phoenx AZ

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

StormMaster Slate General Instructions 1.) GENERAL INSTRUCTIONS 2.) ROOF DECK VENTILATION 3.) ROOF DECK

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF PANELS REPORT HOLDER:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

LAMINATED SHINGLES CERTAINTEED SHINGLE APPLICATOR S MANUAL SUPPLEMENT

SECTION INTERIOR FINISH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

ForceField Air & Water Barrier System. installation instructions

1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights

ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year.

F-WAVE REVIA SYNTHETIC ROOFING SHINGLES

t H e B e A U t Y o F s H A K e. t H e s t r e n G t H o F L A M A r i t e. s H i n G L e s A n d A c c e s s o r i e s

Hip & Ridge Shingles Installation Instructions

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

ES Report GAF-Elk Shingle Roof Covering Systems ESR-1475

Brava Old World Slate Installation Guide

SECTION ROUGH CARPENTRY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF EVALUATION SUBJECT:

Hatteras Shingles. CertainTeed Shingle Applicator s Manual. YOUR OBJECTIVE: To learn the correct procedures for installing Hatteras shingles

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

FLORIDA PRODUCT APPROVAL 5VCRIMP FLORIDA PRODUCT APPROVAL NO R2. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

Wood shakes and wood shingles

*To obtain a copy of TAMKO s limited warranty, visit us online at tamko.com or call us at

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

ROOFING APPLICATION STANDARD (RAS) No. 130

WOODSTART STARTER SHINGLE, STARTER STRIP PLUS, STARTER STRIP SHINGLE, AND TRI BUILT STARTER STRIP

SHEET METAL FLASHING AND TRIM Christ on the Mountain

PRODUCT EVALUATION Effective July 1, 2009 RC-204

SECTION CARPENTRY

Multi-Width Shake. Widths: 9", 8", 7", 6", 4" Length: 22" Thickness at butt: 5/8" Single-Width Shake. Widths: 9" Length: 22" Thickness at butt: 5/8"

PREMIUM LAMINATED ASPHALT SHINGLES Frederick, MD

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

HERITAGE LAMINATED ASPHALT SHINGLES Frederick, MD

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

MAGNUM. I N S P E C T I O N S Inc. ROOF Walked on roof, crawled attic where accessible.

OWENS CORNING LAMINATE SHINGLES INSTALLATION INSTRUCTIONS

T h e b e a u t y o f s l a t e. T h e s t r e n g t h o f L a m a r i t e. S h i n g l e s a n d A c c e s s o r i e s

IRONWOOD SHAKE & FLASHING SPECIFICATIONS

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

SECTION BULLET- RESISTANT DOORS

EVALUATION REPORT GAF Materials Corporation 1361 Alps Road, Building 7-3 Wayne, NJ 07470

Cambridge English Application Instructions

SECTION INTERIOR FINISH CARPENTRY

C e r t a i n T e e d S h i n g l e A p p l i c a t o r s M a n u a l. and Carriage House STEEP. Slope Application. (over 21/12)

Slate Shingle Specifications

Installation Guide. Titan Old World Slate REV Titan Manufacturing Phone: (407) Fax: (866)

ASPHALT T E C H N O L O G I E S

Technical Note No. 028

Transcription:

ENDUREED VIVA SERIES Specifications

SECTION 07312 HDPE THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. This Section Includes the following: 1. Endureed Viva Series synthetic thatch shingles. 2. Self-adhering sheet underlayment. B. Related Sections include the following: 1. Section 06100- ROUGH CARPENTRY for roof deck wood structural panels and additional framing. 2. Section 07600 SHEET METAL FLASHING for metal counter flashings not part of this section. 1.02 SUBMITTALS A. Product Data: For each type of product indicated. B. Samples for Verification: For the following products, of sizes indicated, to verify color selected. 1. Endureed Viva Series synthetic Thatch Shingle: 12" shingle 2. Optional Self-Adhering Underlayment: 12 inches square. C. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency or by manufacturer and witnessed by a qualified testing agency, for Endureed Viva Series thatch shingles. D. Maintenance Data: For Endureed Viva Series synthetic thatch shingles to include in maintenance manuals. E. Warranties: Special warranties specified in this Section. 1.03 PERFORMANCE REQUIREMENTS A. General: Provide installed Endureed Viva Series synthetic thatch shingles, self adhering membrane and base flashings if required, that remain watertight; do not permit the passage of water; and resist specified uplift pressures, thermally induced movement, and exposure to weather without failure. B. Fire-Test-Response Characteristics: Provide Endureed Viva Series synthetic thatch shingle and related roofing materials with the fire-test-response characteristics indicated, as determined by testing identical products per test method below by UL or another testing and inspecting agency

acceptable to authorities having jurisdiction. Identify materials with appropriate markings of applicable testing and inspecting agency. 1. Exterior Fire-Test Exposure: Class A, ASTM E 108 or UL 790, for application and roof slopes indicated. C. Wind Uplift Design: Provide roofing system that complies with the following: 1. Roofing System Manufacturer s written design instructions. 2. 2007 UBC Chapter 16 Division III require wind forces: a) Exposure Category: Exposure D b) Basic Wind Speed: 110mph c) Importance Factor: 1.0 3. ASTM D3161 110mph wind rating. 1.04 QUALITY ASSURANCE A. Manufacturer Qualifications: Endureed Viva Series synthetic shingles as manufactured by Global Innovation LLC. B. Testing Agency Qualifications: An independent testing agency with the experience and capability to conduct the testing indicated, as documented according to ASTM E 548. 1.05 DELIVERY, STORAGE, AND HANDLING A. Store roofing materials in a dry, well-ventilated, weather tight location according to Endureed Viva Series synthetic thatch shingle manufacturer s written instructions. Thatch shingle boxes must remain properly stacked. Boxes not to exceed shipping configuration. Store underlayment rolls on end on pallets or other raised surfaces. Do not double-stack rolls. 1. Handle, store, and place roofing materials in a manner to avoid significant or permanent damage to roof deck or structural supporting members. B. Protect unused underlayment from weather, sunlight, and moisture when left overnight or when roofing work is not in progress. 1.06 WARRANTY A. Special Warranty: Manufacturer s standard form in which manufacturer agrees to repair or replace Endureed Viva Series synthetic thatch shingles that fail in materials or workmanship in accordance with current warranty terms. Material failures include manufacturing defects, rot/decay, de-lamination, or UV degradation.

PART 2 PRODUCTS 2.01 BASIS-OF-DESIGN PRODUCT A. Product indicated on the drawings and described in this section are Endureed Viva Series synthetic thatch shingles 2.02 MATERIALS A. Synthetic Thatch Shingle: Simulated reeds/leaf formed into a textured shingle with variegated colors and cut with a random cut pattern. 1. Leaf Style: Endureed Viva Series Viva Palm Thatch 2. Shingle Dimensions: 36-inches long by 26-inches tall 3. Average Exposure Length: 7 inches B. Synthetic Thatch Hip shingle: Simulated reeds/leaf formed into a textured shingle with variegated colors and cut with a random cut pattern. (Not used in all roof applications) 1. Leaf Style: Endureed Viva Series Viva Palm Thatch 2. Provides 7 lineal inches of hip coverage C. Optional Self-Adhering Sheet Underlayment. 1. Product: Elastophene Stick HR FR GR ( Tan ) manufactured by Soprema. 2.03 ACCESSORIES A. Asphalt Roofing Cement: ASTM D 4586, Type II, asbestos free. B. Roofing Nails: ASTM F 1667; 11 gauge stainless-steel, annular ring shank, sharp-pointed, with a minimum 11/32-inch diameter flat head and of sufficient length to penetrate ¾ inch into solid wood or extend at least 1/8 inch through plywood sheathing. 2.04 METAL FLASHING AND TRIM A. Sheet Metal Flashing and Trim: Comply with requirements in Section 07600 SHEET METAL FLASHING. 1. Recommended Sheet Metal: 16oz copper. 2. 2. Alternate Sheet metal as recommended or approved by architect and/or local building department. PART 3- EXECUTION

3.01 EXAMINATION A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of work. 1. Examine roof sheathing to verify that sheathing joints are supported by framing and blocking or metal clips and that installation is within flatness tolerances. 2. Verify that substrate is sound, dry, smooth, clean, sloped for drainage, and completely anchored; and that provision has been made for flashings and self-adhering membrane. 3. Submit written report, to the Contractor signed by Installer, listing conditions detrimental to performance of work. B. Proceed with installation only after unsatisfactory conditions have been corrected.