XARS8D18p / XARS12D18p / XARS8L12p Quick Start Guide

Similar documents
Harmony XB5R. Expert Instruction Sheet 11/ EIO

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Power connections, minimum and maximum wiring capabilities, tightening torque

C-Bus 8 Channel Low Voltage Relay

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

/2008. Altistart 22. Soft start - soft stop unit. User manual 09/2009 BBV

Installation Instructions

Altistart 22. Sc~'leider. Soft start - soft stop unit. User manual. c.; Electric 09/ Schneider- Alii start 22

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

BLEMO Frequenzumrichter. Siemensstraße 4 D Rodgau Dudenhofen Germany

Remote Radio Control. Push Button Transmitters. M880 Radio Control for Tower Cranes

G5 System Family and Accessories

Robot e.do. Safety requirements and technical specifications. Rel axes and 6 axes versions

MRT. Instruction Manual. Remote Crane Controls. PSMRTINST-01A October, 2001 Part Number: Copyright 2001 Electromotive Systems

IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment.

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Rosemount 753R Remote Web Based Monitoring Indicator

The system (EF-7700) consists out of two parts: the transmitter (EF-7602) and the receiver including wiring (EF-7701).

Installation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

Installation and Operational Instructions for ROBA -switch Type 017._00.2

2011 / Circuit Tracer

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Refrigeration Drive kw

Base unit Connection

ECM3 EARTH CONTINUITY RELAY

jr. Instruction Manual Remote Crane Controls MagneTek

P700-WLS ioprox Receiver

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Refrigeration Drive FC kw

Installation instructions

02/11/2015

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview

1000 SERIES INSTALLATION SUPPLEMENT Rev. 7/1/10

Panther. Installation instructions. Receivers PN-R15-1 PN-R15-2 PN-R15-13 PN-R IM-PN-RX103-A03-EN Language: English (original)

1000 SERIES INSTALLATION SUPPLEMENT Rev

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

Rosemount 5408 and 5408:SIS Level Transmitters

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Maintenance Information

Earth Fault Indicator EFI-BLZ-50 User Manual

Installing the IPS 4240 and the IPS 4255

Operating Instructions

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

BC145 SIGNAL ISOLATOR BOARD

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

S1 Minor (usually reversible) injury S2 Serious (normally irreversible) injury including death

Data sheet. Function description. Benefits

Modicon Quantum 140 NRP /01 Fiber Converter Modules User Guide

MOTOMAN-MH5(L)S/F, -MH5(L)SII MAINTENANCE MANUAL

02/11/2015

E-STOP relays, safety gate monitors

Dynamo Brushless DC Motor and GreenDriveTM Manual

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

3TK28 Safety Relays. General data. 7/70 Siemens LV

Capacitor Switching Contactors

Commercial Microwave Technical Information. CAUTION All safety information must be followed as provided in Service Manual

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Installation and Operating Instructions for Phase Demodulator Type _.2

Z07- SWING GATE HOME AUTOMATION. zero Z07 - SWING GATE MOTOR SUPPLY V HOME AUTOMATION IT EN FR Z07.REV USER MANUAL AND CONFIGURATION PG1

Radio Control Installation and Operating Instructions System 4

LIGHT- INDUSTRIAL SLIDING GATE OPERATORS

PACSystems* RX3i IC695MDL765

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

INSTALLATION AND OPERATION MANUAL

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

Blue Point Engineering

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Installation guide 873 SmartRadar Control Unit & Antenna Unit

WORLD-BEAM QS30AF Sensor

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

EVERGREEN EM INSTALLATION GUIDE

Dawson DDM190. Digital Multimeter User s Manual

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

H LONTalk Integration Node For Use With H704 and H663 Branch Current Monitors (BCM) H NOTICE DANGER INSTALLATION GUIDE DIMENSIONS

WEBS-MT/R Tower Installation Instructions

Safety light curtain to safeguard the hinge edge IMPORTANT NOTE

Remote Radio Control. WAVE Push button radio control systems

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

USER'S MANUAL DMR-6700

FLEXMini. Instruction Manual

MEGA REMOTE RADIO REMOTE CONTROL SYSTEM

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Multilin DGT. Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators. Control. Advanced Communications

Thuraya Orion IP Satellite Terminal. Maritime Installation Guide

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

INSTALLATION MANUAL. REMOTUS JUPITER Era 4/6/8B

USERS GUIDE EAGLE SMR MOTION SENSOR

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

INSTALLATION INSTRUCTIONS ATV WINCH MULTI-MOUNT Multi-Mount Mounting-Kit: PN Application: YAMAHA BIGBEAR 00+

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

Transcription:

Quick Start Guide Harmony www.schneiderelectric.com www.schneiderelectric.com/control TM XARS8D18W / XARS8D18H / XARS12D18W / XARS12D18H exlhoist XARS8L12W / XARS8L12H DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH p Disconnect all power from all equipment including connected devices, prior to removing any covers or doors, or installing or removing any accessories, hardware, cables, or wires except under the specific conditions specified in the appropriate hardware guide for this equipment. p Always use a properly rated voltage sensing device to confirm the power is off where and when indicated. p Replace and secure all covers, accessories, hardware, cables, and wires and confirm that a proper ground connection exists before applying power to the unit. p Use only the specified voltage when operating this equipment and any associated products. Failure to follow these instructions will result in death or serious injury. p Use appropriate safety interlocks where personnel and/or equipment hazards exist. p Install and operate this equipment in an enclosure appropriately rated for its intended environment. p Do not disassemble, repair, or modify this equipment. p Do not connect any wiring to unused connections, or to connections designated as Not Connected (N.C.). Failure to follow these instructions can result in death, serious injury, or equipment damage. It is recommended to charge the battery once a week, for a duration of at least 4 hours. Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. You can download our technical user guide file as well as the exlhoist configuration software from our website at www.schneiderelectric.com. Power line must be wired and protected with fuse or thermal magnetic switch (ex: SchneiderElectric GV2) in compliance with local and national regulatory requirements for the rated current and voltage of the particular equipment. Failure to follow these instructions can result in death, serious injury, or equipment damage. Put the remote into STOP mode when not operating the unit to avoid accidental operations of motions push buttons. Failure to follow these instructions can result in death, serious injury, or equipment damage. Note: You can decrease the "standby time out" value using the configuration software tool to reduce the time the remote is in run mode. ZART8D ZART8D ZARB18W XARS8D18W ZART12D ZARB18H XARS12D18W XARS8D18H ZART8L ZARB12W ZARB12H XARS8L12H 1/8 ZARB18H XARS12D18H ZART8L XARS8L12W NHA4589 02 09 201 ZART12D ZARB18W

Main characteristics Base station ZARBppp mm in. 291 11.4 87,.44 Install and operate this equipment according to the environmental conditions described in the operating limits. Failure to follow these instructions can result in death, serious injury, or equipment damage. 4 2 1 www.schneiderelectric.com ZARB H 5 2 1 272 (ZARBpW) 10.7 24,8 (ZARBpH) 10.42 241,2 9.5 ZARB W 1 : M12 for external antenna (covered by cap) 2 : Status LEDs : M20 for the safeguarding function input wires (covered by cap) 4 : 2 pins connector 5 : M25 for output wires (covered by cable gland) : M25 for detected applicative alarms input wires (covered by cap) Specifications Operating voltage Current consumption (maximum current in connected or not connected state) Operating temperature Details AC/DC power supply Min max For 24V DC For 24V AC For 48V DC For 48V AC For 240V DC For 240V AC For 24...48 V AC/DC power supply Values ZARB12H ZARB12W ZARB18H ZARB18W 24...48 V AC/DC ± 20% 24...240 V AC/DC ± 20% 24...48 V AC/DC ± 20% 24...240 V AC/DC ± 20% 28 ma 55 ma 155 ma 12 ma 44 ma 44 ma 250 ma 250 ma 25...70 C (1...158 F) For 48...10 V AC/DC power supply 25...70 C (1...158 F) 25...70 C (1...158 F) For 10...240 V AC/DC power supply 25...50 C (1...122 F) 25...50 C (1...122 F) Degree of protection IP5 / NEMA 4 Remote control ZARTppp mm 92 in..2 111 4.7 Specifications Details Values ZART8L ZART8D ZART12D Operating radio range Free field > 00 m 2 12.72 Operating temperature 20...0 C (4...140 F) Operating temperature to charge battery Degree of protection Office environment 10...40 C (50...104 F) IP5 / NEMA 4 Charger for remote device,0 ± 1 1.42 ± 0.04 5,0 ± 1 2.09 ± 0.04 8,0 ± 1 0.1 ± 0.04 mm in. 102,0 ± 1 4.02 ± 0.04 99,0 ± 1.90 ± 0.04 Specifications Operating voltage Details Values 110 / 240 VAC 900 1000 5.4 9.7 Operating temperature Degree of protection Office environment 0...40 C (2...104 F) IP20 Output Plug : Ø 5.5 x Ø 2.5 x 11.0 mm Inner Positive NHA4589 02 09 201 2/8

www.schneiderelectric.com Wiring p Use shielded cables wherever specified for inpunts and outputs connections. p Properly ground the cable shields as indicated in the related documentation. p Route I/O cables separately from power cables. Failure to follow these instructions can result in death, serious injury, or equipment damage. Connect the Base Station protective earth ground connection to the machine ground. Failure to follow these instructions can result in death, serious injury, or equipment damage. Base station terminal wiring S2_S ZARB18W IN5 IN IN1 IN15 IN17 IN18 IN IN4 IN12 IN11 IN1 IN14 IN1 IN2 IN8 IN7 IN9 IN10 S2_S CR_18 CC_18 8 CR_17 CC_17 7 CC_1 5 CC_15 4 CC_14 CC_1 2 AC_Neutral /AC_Phase /+ ZARB12W 2 AC_Neutral /AC_Phase /+ Base station ZARBppH Connector pin out 0 57 5 54 1 58 55 2 59 5 49 45 41 7 29 25 21 17 1 9 5 1 50 4 42 8 4 0 2 22 18 14 10 2 51 47 4 9 5 1 27 2 19 15 11 7 52 48 44 40 2 28 24 20 1 12 8 4 A : Pin number B : ZARB18H description C : ZARB12H description A 1 B CR_18 C A 17 B C A B C A 49 B C 2 4 5 7 8 9 10 11 12 1 14 15 1 CC_18 8 CR_17 CC_17 7 CC_1 4 CC_14 2 2 18 19 20 21 22 2 24 25 2 27 28 29 0 1 2 5 S2/S IN CC_1 CC_15 IN2 S2/S 4 5 7 8 9 40 41 42 4 44 45 4 47 48 IN1 IN4 IN5 IN 50 51 52 5 54 55 5 57 58 59 0 1 2 AC_Neutral AC_Phase AC_Neutral AC_Phase Cable length maximum 50 m (14 ft) DANGER NOTICE FIRE HAZARD Use only the recommended wire sizes for I/O channels and power supplies. Failure to follow these instructions will result in death or serious injury. INORABLE EQUIPMENT Do not tighten screw terminals beyond the specified maximum torque (Nm / lbin.). Failure to follow these instructions can result in equipment damage. 7 mm in. 0.28 mm 2 0.2 2.5 0.2 2.5 0.25 2.5 0.25 2.5 2 x 0.2 1 2 x 0.2 1.5 2 x 0.25 1 2 x 0.5...1.5 AWG 24 14 24 14 2...14 2 x 24 17 2 x 24 1 2 x 2 17 2 x 20...1 N m lbin 0.5...0. 4.42...5.1 Ø,5 mm (0.14 in.) NHA4589 02 09 201 2...14 /8

www.schneiderelectric.com Electrical diagram Base station ZARBppp Inputs / Outputs Input / Output Possible uses ( depending of the configuration) Feedback loop input Base station ZARBppp safety relays internal wiring 1 2 (1) (14) IN1...IN IN7...IN18 Applicative Alarm (only for ZARB18p) Limit Switches (only for ZARB18p) (2) (24) Q0A (1/14) Q0B (2/24) Q1...Q9 Q10...Q1 (NO type) Q17, Q18 (NO+NC type) Safety relays Motion relays Auxiliary relays (Q1 to Q18 only for ZARB18p) Specific relays (only for ZARB18p) 1 : Safety relay 1 2 : Safety relay 2 Base station ZARB18p Applicative alarms Base station ZARB18p wiring diagram for the applicative alarm devices Input Description IN1 IN2 Overload prealarm Overload alarm 1 2 4 5 IN IN4 IN5 Over wind prealarm Over wind alarm Over speed alarm IN_ IN 1 COM IN 2 IN IN 4 IN 5 IN IN Generic alarm The ZARB18p base station implements inputs : IN1...IN Differents sensors can be connected to these inputs These inputs are dedicated for applicative alarms The IN1 to IN input cable length should not exceed 50 m (14 ft) For EStop SIL, PLe, category 4 refer to the user manual. For the other cases, connect to S2_S signals. ZARBppp Informs that the feedback loop is opened ZARTppD ZART8L S2_S Feedback loop Example of wiring for EStop and Stop SIL2, PLd, category Phase for contactors or 24 Vdc for drive Phase / + V1 EStop function : category STOP function : category Example of wiring for EStop and Stop SIL2, PLd, category, mix drives and contactors Phase / + 24 Vdc V2 V1 EStop function : category STOP function : category / AC_NEUTRAL AC_PHASE / + A1 K1 A2 Neutral / 0V S2_S V1 Relay ZARB12 2 To horn Selector Pos2 Selector Pos1 To Z axis contactors or to LI drive Z To Y axis contactors or to LI drive Y To X axis contactors or to LI drive X / AC_NEUTRAL AC_PHASE / + A1 K1 A2 Neutral / 0V S2_S V1 Relay ZARB12 ZARB_ V2 2 To horn Selector Pos2 Selector Pos1 To Z axis contactors To LI drive Y To LI drive X NHA4589 02 09 201 4/8

www.schneiderelectric.com/control www.schneiderelectric.com Mechanical installation 28, 7 10.5 mm in. 218, 8. Ø 4 maxi Ø 0.1 maxi ZARC09 / ZARC091 1 EAV9017 2 1' ZARC091 : Fixation kit with magnet supports ZARC09 : Fixation kit with silent block EAV9017 NHA4589 01 09 201 5/8 EAV9017

www.schneiderelectric.com Pairing with discovering (only for ZARTppD) Base station ID : 0080F40011AE Label : 1 P7/8 1s ON < 5 min 2 4 5 7 8 9 1s NHA4589 01 09 201 /8

www.schneiderelectric.com Pairing with configuration software ID 1: 14 15 12 1 10 11 8 0080F40011AE 0080F40011AE 9 H 1H 1 5 2 2H 4 Base station ID : 0080F40011AE Label : 4H NOTICE INORABLE EQUIPMENT p Always connect the communication cable to the PC before connecting it to the device. p Only use the Schneider Electric cable TCSMCNAMM002P. Failure to follow these instructions can result in equipment damage. RJ45 USB exlhoist configuration software DOWNLOAD www.schneiderelectric.com Diagnostics Base station ZARBppp Diagnostic LEDs LED Color Status Green ON State COM Yellow OFF Power White The remote control system is working properly OFF Description Base station power OFF or internal fault detected No communication between the base station and the remote control device Blinking The communication is established between the base station and the remote control device OFF Base station powered OFF ON Base station powered ON Remote device ZARTppD Diagnostic Display 1s + + <5s Inputs state Relays state Exit NHA4589 01 09 201 7/8

www.schneiderelectric.com Accessories ZARC01 : Charger for remote device EAV57251 ZARC02 : Shoulder belt for remote device ZARC0 : External antenna for base station HRB57274 EAV5990 ZARC04 : Holder for remote device ZARC05 / ZARC12 / ZARC18 : Connector plug female ZARC05 : 1,5 m / 4.92 ft ZARC12 : m / 9.84 ft ZARC18 : 5 m / 1.40 ft HRB57277 EAV5727 ZARC20 : Bellows ZARC21 : Protections EAV52985 EAV52994 NHA4589 01 09 201 8/8