Table of Contents IMPORTANT

Similar documents
Table of Contents IMPORTANT

Installation *HDWL-INSTR-001* IMPORTANT. Plastic Laminate Restroom Partitions Floor-Mounted with Overhead Brace Series 400

Installation. *HDWC-INSTR-007* HDWC-INSTR-007 Rev. K; ECN G 2018 Bradley Page 1 of 24 3/22/2018

Installation. *HDWC-INSTR-006* HDWC-INSTR-006 Rev. K; ECN G 2018 Bradley Page 1 of 24 3/22/2018

Installation. *HDWC-INSTR-008* HDWC-INSTR-008 Rev. H; ECN G 2018 Bradley Page 1 of 24 3/22/2018

INSTALLATION INSTRUCTIONS

Installation Manual for Metal Toilet Partitions Standard Series

Melamine Plastic Laminate. Toilet Partition Installation Manual

BioPrism Solid Surface

Installation Instructions

Installation Instructions


Installation Manual. Solid Plastic Toilet Partitions. IN CANADA & AREAS OTHER THAN U.S.A.: IN THE U.S.A.:

Installation Instructions

Installation Manual for Metal Toilet Partitions Elite & Elite Plus Series

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions for 30, 40, and 50 Series Plastic Laminate Toilet Partitions.

Stainless Steel 95C34 Series

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

EUROLINE CLASSIC PHENOLIC / EVERGREEN. Installation Instructions. Installation Instructions.

INSTALLATION INSTRUCTIONS

Installation Instructions

Toilet Partition Hardware

EUROLINE CLASSIC SOLID SURFACE Installation Instructions

INSTALLATION INSTRUCTIONS FOR ALPACO CLASSIC PARTITIONS

INSTALLATION INSTRUCTIONS FOR ALPACO CLASSIC PARTITIONS

STANDARD STALL INSTALLATION DETAIL

Oxford Stalls Installation Instructions

INSTALLATION INSTRUCTIONS

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

Hardware. Brackets. Cast Chrome Plated Zamac Door Pack for High Pressure Laminate Compartments T O I L E T P A R T I T I O N S

INSTALLATION INSTRUCTIONS SierraSeries SOLID COLOR REINFORCED COMPOSITE (SCRC) TOILET PARTITIONS

Submittal Transmittal

HEADRAIL BRACED INSTALLATION MANUAL. Tools Required

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Laminate Cabinet Installation Instructions

Double Frameless Swing Door QCI5247

Shetland Stalls Installation Instructions

Frameless Inline Door QCI5254

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Frameless Inline Door With Return QCI5263

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

FIXED PANEL SLIDER QCI5241

Assembly and Installation Guide

SSRLS-3 / SSRLU-3 Installation Instructions

FRAMELESS DOOR / PANEL WITH WALL MOUNT HINGES QCI5274

Frameless Inline Door QCI5248

FIXED SHOWER SCREEN For Wall Mount Hinges QCI5283

Frameless Heavy Glass Door with Header

Frameless Heavy Glass Door with Wall Mount Hinges

Frameless Inline Door QCI5250

Frameless Door QCI5284

ASSEMBLY INSTRUCTIONS TALL CABINET - MODEL CS30

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

Frameless Bypass Slider

Two Panel Frameless Bypass Door

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

TIP FOR GETTING STARTED

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

Frameless Fixed Panel Slider

LOFT DOOR HANGER BARN DOORS & HARDWARE. Hardware Installation Instructions. Page

Privacy Wall Glass Selections - Polished Edge Slider Door

PRE-ENGINEERED HORSE STALL SYSTEMS 4884 HSD STANDARD SLIDING DOOR. & Assembly. Installation Instructions

Track Rack. * Track Racks are not lockable

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Dublin Stalls Installation Instructions

INSTALLATION AND CARE INSTRUCTIONS

INTRODUCTION Tools Required Laminate Washroom Products... 4 DUCT PANELS Fixing the Frame: Fixing the Shadow Panels...

Versatrac Bypass Door Units, Conventional and Top Track, 300 and 400 Series

Assembly Instructions Music Library System

Installation Instructions Edge Storage System

K.D. LOCKER ASSEMBLY INSTRUCTIONS

INSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S ROD IRON SCROLL HANGER R H

INSTALLATION INSTRUCTIONS for the JOMY RETRACTABLE LADDER. If there are any questions, please call (800)

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

Frameless Bypass Slider

WAREHOUSE HANGER INSTALLATION INSTRUCTIONS R H INS T A L L A TIO N INS T R U C TIO N S

Assembly Instructions

Rolling Curtain door Manual

Installation Guide 2016

Installation Instructions

Installation And Care Instructions. Vertical Honeycomb Shades

HOUSE PARTS PACKED IN HOUSE BOX PARTS IN PLASTIC BAG (HARDWARE) PARTS IN SMALL PLASTIC BAG (FLOOR CLIPS) PARTS PACKED IN BUNDLE

MobileTrak5 Installation Instructions

INS T A L L A TIO N INS T R U C TIO N S HORSESHOE W/ BAR HANGER

VACUSEAL MODEL 200. HOT TUB PRODUCTS 233 Carrington Road Bethany CT

Calf-Tel Pen System Assembly Instructions

Hardware and Components:

Windload Post 9100/9600/9900 Installation Instructions

Full Overlay Door Panel Preparation and Installation Instructions for 2175, 2115, CLR2160 Models

Transcription:

For Standard Height oors and Panels Only Plastic Laminate Restroom Partitions eiling-hung Series 600 Table of ontents Pre- Information...2 Layout imensions for rackets...3 Mounting rackets to Wall...4 Leveling rackets to Pilasters...5 Mounting rackets to Pilasters...5 6 Pilaster Mounting Hardware...6 Panels & Pilasters... 7 8 Pilaster Shoes...9 Hinges...9 11 Latch and Strike/Keeper...12 13 Urinal Screens...14 15 IMPORTNT Read this installation manual completely to ensure proper installation, then file it with the owner or maintenance department. This installation manual provides instruction for the assembly of normal partition configurations and standard components. Non-standard configurations or components including but not limited to curved or angled walls, partial walls, oversized panels, or modified hardware are not covered in this manual. ompliance and conformity to local codes and ordinances is the responsibility of the installer. THIS SIE UP Packing List Separate parts from packaging and make sure all parts are accounted for before discarding packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. To prevent warping, always lay the material flat. o not lean the material against the wall or stack unevenly. efore beginning installation, make sure that the wall and floor backing are adequate to support the secure mounting of the toilet compartment units. To minimize break-out, always use a support block when drilling through plastic laminate material. Use caution when drilling. ccuracy is important! Product warranties and parts information may be found on radley's web site at bradleycorp.com. *HWL-INSTR-003* HWL-INSTR-003 Rev. ; EN 13-14-030 2013 radley Page 1 of 15 8/29/2013 P.O. ox 309, Menomonee Falls, WI US 53052-0309 PHONE 800.RLEY (800.272.3539) FX 262.251.5817 bradleycorp.com

Plastic Laminate Restroom Partitions, eiling-hung Series 600 Supplies Required: halk line and pencil Tape measure and 4' level Jigsaw (or hacksaw) and circular saw Two spring clamps ¹ ₈", ⁵ ₃₂", ¼", and ³ ₈" drill bits Power drill or screw gun with drill bit extension ⁵ ₁₆" ceramic tile and masonry drill bit Hammer drill Spacer, 12" (305mm) high and strong enough to support weight of panel Hardware Provided ³ ₈-16 x 6" Threaded Rod FST-T5416 1¼" Sq. x Ø ³ ₈" Washer, eveled FST-T680 #10-24 x 2" Flat-Head Machine Screw Torx-T25 rive FST-Z0027 #14-16 Plastic nchor FST-T373 ³ ₈" Flat Washer FST-L376 ³ ₈-16 Hex Nut FST-T375 ³ ₈" Lockwasher FST-T377 #14 x 2" utton-head Sheet Metal Screw FST-Z002 (hrome Plated) #14 x 2" utton-head Sheet Metal Screw FST-P002 (Stainless) #14 x ⁵ ₈" utton-head Sheet Metal Screw FST-Z0016 #10 x ⁵ ₈" utton-head Sheet Metal Screw FST-Z0019 #10 x 1" utton-head Sheet Metal Screw FST-Z0028 #10 x ¾" Flat-Head Sheet Metal Screw Torx-T25 rive FST-Z0006 ¼"- 14 x ⁵ ₈" Sheet Metal Screw FST-S355 #10-24 x ½" utton-head Shoulder Screw FST-S0018 #10-24 x ¾" utton-head Shoulder Screw FST-P004 (Stainless) #10-24 x ¾" utton-head Shoulder Screw FST-Z004 (hrome Plated) #10-24 x 1" utton-head Shoulder Screw FST-Z004 (hrome Plated) #10-24 x 1" utton-head Shoulder Screw FST-P004 (Stainless) #10-24 x ¾" utton-head arrel Nut FST-P003 (Stainless) #10-24 x ¾" utton-head arrel Nut FST-Z003 (hrome Plated) Example of Submittal rawing 60½" (1537mm) wall to centerline 36" (914mm) center to center 61¼" (1556mm) to face 58½" (1486mm) 58½" (1486mm) 1" (25mm) gap 3" 20½" 3½" 8½" 1½" ½" (13mm) gap 3" (76mm) 1" (25mm) gap 36" (914mm) 24" 24" (610mm) (610mm) 10" (254mm) 2 8/29/2013 radley HWL-INSTR-003 Rev. ; EN 13-14-030

Plastic Laminate Restroom Partitions, eiling-hung Series 600 1 Layout imensions - Stirrup racket (Standard) When installing the partition components, consult the applicable Mills Partition submittal drawing for compartment layout dimensions. Panel centerline: Measure the stall width across the back wall and place a mark at the top of the rear wall ( ). Repeat this step for each panel, starting each measurement from the last panel centerline ( 1 ). Pilaster centerline: Measure from the back wall forward to the face of the compartment, subtract ⁵ ₈" (16mm) and mark this location on the ceiling ( ). Mark the same measurement on the opposite end of your layout ( 1 ) and draw a straight line connecting both marks. FOR FREESTNING (FS) PRTITIONS: Refer to submittal drawings and determine the approximate location of the outside panels. Establish dimensions and 1 as explained above. Stirrup brackets: raw a plumb line on all walls from each pilaster and panel centerline. From the highest point in the room, measure 18" (457mm) and 64" (1626mm) from the floor and place a mark on the pilaster/panel plumb line. These marks represent the hole center line of the stirrup brackets. Use a level to transfer that mark to all other plumb lines ( ). "" * "" * Pilaster plumb line "" "" "" * "1" "1" "" * L "" Panel plumb line * 64" (1626mm) 18" (457mm) 1a Layout imensions - ontinuous racket (Optional) When installing the partition components, consult the applicable Mills Partition submittal drawing for compartment layout dimensions. Pilaster centerline: Measure from the back wall forward to the face of the compartment, subtract ⁵ ₈" (16mm) and mark this location on the ceiling ( ). Mark the same measurement on the opposite end of your layout ( 1 ) and draw a straight line connecting both marks. FOR FREESTNING (FS) PRTITIONS: Refer to submittal drawings and determine the approximate location of the outside panels. Establish dimensions and 1 as explained above. "" * Pilaster plumb line "" "" "" * Panel centerline: Measure the stall width across the back wall and place a mark at the top of the rear wall ( ). Repeat this step for each panel, starting each measurement from the last panel centerline ( 1 ). "1" "1" Panel plumb line ontinuous brackets: raw a plumb line on all walls from each pilaster and panel centerline. From the highest point in the room, measure 12½" (318mm) (for stainless steel) or 12¼" (311mm) (for aluminum) from the floor and place a mark on the pilaster/panel plumb line. Use a level to transfer that mark to all other plumb lines ( ). "" * radley HWL-INSTR-003 Rev. ; EN 13-14-030 8/29/2013 3

Plastic Laminate Restroom Partitions, eiling-hung Series 600 2 Stirrup rackets to Wall (Standard) On end panel and pilaster applications, position the bracket with the ear facing toward the inside of the stall. Pilaster bracket is shown here; 1¼" opening brackets are for pilasters, and 1" opening brackets are for panels. Insert the plastic anchors in all holes and secure the brackets to the wall with the #14 x 2" (chrome plated) screws provided. Using the bracket as a template, mark the hole locations on the wall. Remove the bracket and drill a Ø ⁵ ₁₆" hole (min. 2" [51mm] deep) at each hole location. Place the center of each stirrup bracket at the established level line. enter the bracket opening on the pilaster/panel plumb line. established level line floor pilaster/panel plumb line Two-Eared racket One-Eared racket 2a ontinuous rackets to Wall (Optional) On end panel and pliaster applications, position the bracket with the ear facing toward the inside of the stall. Pilaster bracket is shown here; 1¼" opening brackets are for pilasters, and 1" opening brackets are for panels. rackets are used as templates but since the hole patterns may be different, the brackets may not be interchanged. Insert the plastic anchors in all holes and secure the brackets to the wall with the #14 x 2" (stainless) screws provided. Using the bracket as a template, mark the hole locations on the wall. Remove the bracket and drill a Ø ⁵ ₁₆" hole (min. 2" [51mm] deep) at each hole location. Place the bottom of each continuous bracket at the established level line. enter the bracket opening on the pilaster/panel plumb line. Two-Eared racket established level line floor pilaster/panel plumb line One-Eared racket 4 8/29/2013 radley HWL-INSTR-003 Rev. ; EN 13-14-030

Plastic Laminate Restroom Partitions, eiling-hung Series 600 3 Leveling rackets to Pilaster 3" and 4" pilasters only have one bracket Pre-drilled pilasters (Optional). Find top side of pilaster. Particle board will be visible from top side. ottom side will be covered with laminate. Pre-drilled pilasters have notch at top side. Line up side of bracket with the side of pilaster. O NOT let bracket overhang or shoe will not slide down over the bracket. Slide shoe onto top end of pilaster. Make sure the holes on the sides of the shoe are towards the bottom. Push bumps on bracket against the top end of the pilaster. F Secure the bracket to the pilaster with the #10-24 x ¾" (chrome plated) barrel nuts and #10-24 x 1" (chrome plated) shoulder screws provided. E Using the bracket as a template, mark the hole locations on the pilaster. Remove the bracket and drill Ø ¼" (6mm) holes through the piliaster 4 Stirrup rackets to Pilaster (Standard) Refer to the submittal drawing to locate the split dimension and layout location of each marked pilaster. If installing steel reinforced pilasters refer to label on pilaster for attaching brackets. 52" (1321mm) Secure For Stirrup rackets: Secure the bracket to the pilasters using the #14 x ⁵ ₈" screws provided. the rackets For lcove rackets: Secure the brackets to the pilasters using the #10-24 x 1" (chrome plated) shoulder screws and #10-24 x ¾" (chrome plated) barrel nuts and to the panels with the #10-24 x ¾" (chrome plated) shoulder screws and #10-24 x ¾" (chrome plated) barrel nuts provided. Split Split 6" (152mm) Measure 6" (152mm) and 52" (1321mm) up from the bottom of the pilaster bracket and place a mark on the pilaster split centerline. These marks represent the level line for the stirrup brackets. Pilaster shown is for reference only. ctual pilaster varies depending on application. For lcove racket: Place the center of each bracket at the established level line. Using the bracket as a template, mark the hole locations on the pilaster. Remove the bracket and drill Ø ¼" holes through the pilaster at each pilaster bracket hole. Locate the rackets For Stirrup racket: Place brackets at each established level line. enter the bracket opening on the pilaster split centerline. Using the bracket as a template, mark the hole locations on the pilaster. Remove the bracket and drill a Ø ⁵ ₃₂" x ⁵ ₈" (16mm) deep pilot hole at each location. radley HWL-INSTR-003 Rev. ; EN 13-14-030 8/29/2013 5

Plastic Laminate Restroom Partitions, eiling-hung Series 600 4a ontinuous rackets to Pilaster (Optional) Refer to the submittal drawing to locate the split dimension and layout location of each marked pilaster. rackets are used as templates but since the hole patterns may be different, the brackets may not be interchanged. If installing steel reinforced pilasters refer to label on pilaster for attaching brackets. im. "" im. "" "" "" Split Split Secure the bracket to the pilasters using the #14 x ⁵ ₈" screws provided. Refer to step 4 for attachment of alcove brackets luminum racket Stainless Steel racket ¼" (6mm) ½" (13mm) 57¾" (1467mm) 57½" (1461mm) Measure up from the bottom of each pilaster and place a mark on the pilaster split centerline at dimensions "" & "" for the respective bracket (see table). Pilaster shown is for reference only. ctual pilaster varies depending on application. For lcove racket: Place the center of each bracket at the established level line. Using the bracket as a template, mark the hole locations on the pilaster. Remove the bracket and drill Ø ¼" holes through the pilaster at each pilaster bracket hole. Locate the rackets For ontinuous racket: Place the bracket between each established level line. enter the bracket opening on the pilaster split centerline. Using the bracket as a template, mark the hole locations on the pilaster. Remove the bracket and drill a Ø ⁵ ₃₂" x ⁵ ₈" (16mm) deep pilot hole at each location. 5 Pilaster Mounting Hardware This view is an example only. Refer to your submittal drawings to determine placement of the anchors on the pilaster centerline for your application. Typical anchor centers are measured 1" (25mm) in from each edge of pilaster (except 3" & 4" pilasters where only one anchor is used). Pilaster enterline 3" (76mm) 38" (966mm) 22" (559mm) 26" (660mm) 8" (203mm) Insert each threaded rod through the holes and secure with the beveled washer (if needed), lockwasher and nuts. Lock the threaded rod on the underside of the channel with the flat washer and nut. ttach a support nut to the underside of the channel at each threaded rod (see "" below). eveled Washer ³ ₈" Flat Washer ³ ₈" Hex Nut rill a ø ³ ₈" hole in the channel. "" channel and ceiling (not included) required for ceiling hung partition installation. ¾" (19mm) "" channel eiling 2¼" (57mm) max. stud projection 3" (76mm) max. Starting at the highest point in the room, adjust the support nut approximately ¾" (19mm) down from the finished ceiling. Level the remaining support nuts and washers to this height. 6 8/29/2013 radley HWL-INSTR-003 Rev. ; EN 13-14-030

Plastic Laminate Restroom Partitions, eiling-hung Series 600 6 Panels and Pilasters with Stirrup rackets (Standard) Pilasters located at walls should be mounted first. Start at one end and install a panel, then a pilaster. ontinue alternating until installation is complete. When installing in an alcove or in-corner alcove, use an alcove bracket to secure the pilaster to the panel. heck to make sure the pilasters are plumb and level to each other. The pilaster height can be adjusted by moving the support nuts on the threaded rods up or down. Pilasters at Wall When installing pilasters at walls, the gaps range from ½" to 1¼" (13mm to 32mm). Refer to your submittal drawing for your gap sizes. Slide a washer onto each threaded rod. Set the pilaster mounting brackets onto the mounting hardware and at the same time placing the pilaster into the wall brackets. Then add a washer and nut to the underside of each stud and hand-tighten the hex nuts. Panels with Pilasters Refer to your submittal drawing and leave the appropriate gaps. Standard gap is 1" (25mm) between the panel and wall and ½" (13mm) between the panel and pilaster. Place a panel on the spacer and insert the panel into the bracket. Slide a washer onto each threaded rod. Set the pilaster mounting brackets onto the mounting hardware and at the same time placing the pilaster into the wall brackets. Then add a washer and nut to the underside of each stud and hand-tighten the hex nuts. 12" (305mm) Spacer Using the brackets as templates, drill Ø ¼" holes through the pilaster at each pilaster bracket hole. Using the brackets as templates, drill Ø ¼" holes through the panel at each panel bracket hole. Secure the pilaster to the brackets with the #10-24 x ¾" (chrome plated) barrel nuts and #10-24 x 1" (chrome plated) shoulder screws. E Secure the pilaster to the panel and the panel to the wall brackets with the #10-24 x ¾" (chrome plated) barrel nuts and #10-24 x ¾" (chrome plated) shoulder screws. radley HWL-INSTR-003 Rev. ; EN 13-14-030 8/29/2013 7

Plastic Laminate Restroom Partitions, eiling-hung Series 600 6a Panels and Pilasters with ontinuous rackets (Optional) Pilasters located at walls should be mounted first. Start at one end and install a panel, then a pilaster. ontinue alternating until installation is complete. When installing in an alcove or in-corner alcove, use an alcove bracket to secure the pilaster to the panel. heck to make sure the pilasters are plumb and level to each other. The pilaster height can be adjusted by moving the support nuts on the threaded rod up or down. Pilasters at Wall When installing pilasters at walls, the gaps range from ½" to 1¼" (13mm to 32mm). Refer to your submittal drawing for your gap sizes. Slide a washer onto each threaded rod. Set the pilaster mounting brackets onto the mounting hardware and at the same time placing the pilaster into the wall brackets. Then add a washer and nut to the underside of each stud and hand-tighten the hex nuts. Pilasters with Panels Refer to your submittal drawing and leave the appropriate gaps. Standard gap is 1" (25mm) between the panel and wall and ½" (13mm) between the panel and pilaster. Place a panel on the spacer and insert the panel into the wall bracket. Slide a washer onto each threaded rod. Set the pilaster mounting brackets onto the mounting hardware placing the bracket around the panel. Then add a washer and nut to the underside of each stud and hand-tighten the hex nuts. 12" (305mm) Spacer Using the bracket as a template, drill Ø ¼" holes through the pilaster at each pilaster bracket hole. Using the bracket as a template, drill Ø ¼" holes through the panel at each panel bracket hole. Secure the pilaster to the bracket with the #10-24 x ¾" (stainless) barrel nuts and #10-24 x 1" (stainless) shoulder screws for aluminum or stainless steel brackets. E Secure the pilaster to the panel and the panel to the wall brackets with the #10-24 x ¾" (stainless) barrel nuts and #10-24 x ¾" (stainless) shoulder screws for aluminum or stainless steel brackets. 8 8/29/2013 radley HWL-INSTR-003 Rev. ; EN 13-14-030

Plastic Laminate Restroom Partitions, eiling-hung Series 600 7 Secure Shoe to Pilaster fter panels and pilasters are secured with brackets, tighten the hex nut holding the pilaster to the mounting hardware and slide the shoe up into position. Using the hole in the shoe as a template, drill a Ø ⁵ ₃₂" pilot hole all the way through the pilaster. Secure the shoe to the pilaster with the ¼ -14 x ⁵ ₈" fasteners provided. 8 Wraparound Gravity Hinges (Standard) efore installing the hinges, make sure the door openings are the appropriate size, all pilasters are plumb, the pilaster mounting hardware is tightened securely and the shoe is attached to the pilaster. etermine the door swing by facing the compartment from the outside. Refer to your submittal drawings to determine each specific door swing for your application. Right-hand inswing (RHI) Left-hand inswing (LHI) Right-hand outswing (RHO) Left-hand outswing (LHO) eiling Hung Pilaster Measure up 1¾" (44mm) and 54²¹ ₃₂" (1388mm) from the bottom of the pilaster and mark a level line. This line represents the lower hole location of the top and bottom hinge. Using the hinge as a template, align the bottom hole with each level line and drill Ø ¼" holes through the pilaster. Wall Hung 58" (1473mm) 54²¹ ₃₂" (1388mm) 54²¹ ₃₂" (1388mm) 1¾" (44mm) 1¾" (44mm) radley HWL-INSTR-003 Rev. ; EN 13-14-030 8/29/2013 9

Plastic Laminate Restroom Partitions, eiling-hung Series 600 8 Wraparound Gravity Hinges (Standard) The door hinge assembly consists of separate door and pilaster hardware. Identical assemblies are provided for the top and bottom hinge. Insert top nylon cam into the upper and lower door hinge closure bracket so the cam base is flush with the bracket surface. losure racket ottom am Top am oor Hinge Pin Hinge racket arrel Nut Pilaster Screw onnect the pilaster portions of the hinge to the door portions of the hinges by inserting the hinge pin through the top and bottom of the door until the pin is flush with the top of the door. Insert each door hinge closure bracket (with top cam in place) into the upper and lower openings in the door, anchoring with a #10 x 1" screw. Shoulder Screw E With hinges assembled to the door, set the door on the 12" spacer. Postion the door so that the hinge bracket wraps around the pilaster. Starting at the top hinge bracket hole, secure door to pilaster with #10-24 x ¾" (chrome plated) barrel nut and #10-24 x 1" (chrome plated) shoulder screw. Finished View of Hinge Insert bottom nylon cam into the pilaster portion of the hinge bracket assembly. The cam should be set to the same desired position on the upper and lower hinge assemblies. otttom cam can be set in different positions (-30, -15, 0, 15, and 30 ) by sliding cam rib into the different bracket grooves ottom am Pilaster portion of hinge 10 8/29/2013 radley HWL-INSTR-003 Rev. ; EN 13-14-030

Plastic Laminate Restroom Partitions, eiling-hung Series 600 8a ontinuous Spring-Loaded Piano Hinge (Optional) efore installing the hinges, make sure the door openings are the appropriate size, all pilasters are plumb, that the pilaster mounting hardware is tightened securely and the shoe is attached to the pilaster. etermine the door swing by facing the compartment from the outside. Refer to your submittal drawings to determine each specific door swing for your application. Right-hand inswing (RHI) Left-hand inswing (LHI) Right-hand outswing (RHO) Left-hand outswing (LHO) ontinuous Piano Hinge Part # Prefix HWT-S0209 Part # Prefix HWT-S0208 (left hand in, right hand out, (right hand in, left hand out, knuckles facing front) knuckles facing front) The part numbers listed are prefixes only and are used to identify the appropriate door kit based on your door swing as determined above. Inswinging doors should have hinges mounted on the inside of the stall while outswinging doors should have hinges mounted on the outside of the stall. oor side Pilaster side oor side Pilaster side losed oor View The hinge should be plumb and centered in the ⁹ ₃₂" (7mm) gap opening and also top to bottom (approximately ¼" (6mm)down from the top of the door). Using the hinge as a template, drill Ø ¼" holes through the door at the top and bottom holes. Secure the hinge to the door with the #10-24 x ½" shoulder screws and #10-24 x ¾" (stainless) barrel nuts provided. heck to make sure the gaps are still at ⁹ ₃₂" (7mm). Using the hinge as a template drill Ø ¼" holes through the pilaster at the top and bottom holes. Secure the hinge to the pilaster with #10-24 x ¾" (stainless) shoulder screws and 10-24 x ¾" (stainless) barrel nuts. rill Ø ¼" holes through the remaining hinge holes on the door and pilaster. Secure with the fasteners provided. Place a door on a spacer and set the gap at the hinge and latch side. Standard gap is ⁹ ₃₂" (7mm). Spacer 12" (305mm) above finished floor radley HWL-INSTR-003 Rev. ; EN 13-14-030 8/29/2013 11

Plastic Laminate Restroom Partitions, eiling-hung Series 600 9 Latch and Strike/Keeper for Inswing oors Local codes vary from state to state. heck your local codes before installing the coat hook and door pulls. ¹ ₈" (3mm) Position the slide latch on the inside of the door, centered top to bottom on the door. The leading edge of the latch body should be ¹ ₈" (3mm) from the door edge. With the door in the closed position, place the keeper on the pilaster and then align the latch slide bar so that it fits within the top notch of the keeper and operates freely. This will allow the egress function to operate properly should the latch malfunction. L Using the latch as a template, mark the hole locations on the door. Remove the latch and drill an Ø ¹ ₈" x ⁵ ₈" (16mm) deep pilot hole at each location. Secure the latch to the door with the #10 x ⁵ ₈" screws provided. E For 34" 36" doors, drill two Ø ¼" holes (spaced 3½" [89 mm] apart) through the door and mount the door pulls to the door as shown with the #10-24 x 2" flat machine screws provided. 3½" (89mm) Using the keeper as a template, mark the hole locations on the pilaster and drill two Ø ¼" holes through the pilaster. Secure the strike/keeper to the pilaster with #10-24 x ¾" (chrome plated) barrel nuts and #10-24 x 1" (chrome plated) shoulder screws provided. 3" (76mm) 3" (76mm) F Install the coat hook on the inside of the door on the latch side at a location 3" (76mm) down from the top and 3" (76mm) in from the side. Using the coat hook as a template, drill two Ø ¹ ₈" pilot holes ⁵ ₈" (16mm) deep. Secure the coat hook with the #10 x ⁵ ₈" screws provided. Typical Inswing Flat Strike/Keeper Position the strike as shown (door with slide latch should be in the closed position and latch should be able to engage the slot in the flat strike). Using the flat strike/keeper as a template drill two Ø ¹ ₈" pilot holes ¾" (19mm) deep. Secure the inswing flat strike/keeper with the #10 x ¾" screws provided. 12 8/29/2013 radley HWL-INSTR-003 Rev. ; EN 13-14-030

Plastic Laminate Restroom Partitions, eiling-hung Series 600 9a Latch and Strike/Keeper for Outswing oors Local codes vary from state to state. heck your local codes before installing the coat hook and door pulls. Position the slide latch on the inside of the door, centered top to bottom on the door. The leading edge of the latch body should be ⁵ ₈" (16mm) from the door edge. With the door in the closed position, place the keeper on the pilaster and then align the latch slide bar so that it fits within the top notch of the keeper and operates freely. This will allow the egress function to operate properly should the latch malfunction. ⁵ ₈" (16mm) L Using the latch as a template, mark the hole locations on the door. Remove the latch and drill an Ø ¹ ₈" x ⁵ ₈" (16mm) deep pilot hole at each location. Secure the latch and spacer to the door with the #10 x 1" screws provided. E For outswing doors, drill two Ø ¼" holes (spaced 3½" [89mm] apart) through the door and mount the door pulls to the door with the #10-24 x 2" flat machine screws provided (as shown). 3½" (89mm) Using the keeper as a template, mark the hole locations on the pilaster and drill two Ø ¹ ₄" holes through the pilaster. Secure the keeper to the pilaster as shown with #10-24 x ¾" (chrome plated) barrel nuts and #10-24 x 1" (chrome plated) shoulder screws provided. Place the strike on the pilaster below the keeper as shown. Make the hole locations on the pilaster and drill two Ø ¼" holes through the pilaster. Secure the strike to the pilaster with #10-24 x ¾" (chrome plated) barrel nuts and #10-24 x 1" (chrome plated) shoulder screws provided. F Install the wall bumper on the outside of the door on the latch side at a location 3" (76mm) up from the bottom and 3" (76mm) in from the side. rill two Ø ¹ ₈" pilot holes ⁵ ₈" (16mm) deep. Secure the wall bumper with the #10 x ⁵ ₈" screws provided. 3" (76mm) 3" (76mm) Typical Outswing Flat Strike/Keeper Position the strike as shown (door with slide latch should be in the closed position and latch should slide over the top tab portion of the flat strike). 36" (914mm) Install the coat hook on the pilaster 36" (914mm) above finished floor as shown. rill two Ø ⁵ ₃₂" pilot holes ⁵ ₈" G (16mm) deep. Secure the coat hook with the #14 x ⁵ ₈" screws provided. Using the flat strike/keeper as a template drill two Ø ¹ ₈" pilot holes ¾" (19mm) deep. Secure the outswing flat strike/keeper with the #10 x ¾" screws provided. radley HWL-INSTR-003 Rev. ; EN 13-14-030 8/29/2013 13

Plastic Laminate Restroom Partitions, eiling-hung Series 600 10 Urinal Screens with Stirrup rackets (Standard) efore installing the urinal screen components, determine the correct location for your application. raw a plumb line on all walls representing urinal screen centers (see chart below for measurements). These marks represent hole centerlines for the brackets. Use a level to transfer that mark to all other plumb lines. Place the center of each stirrup bracket at each established level line. enter the bracket opening on the plumb line. Using the bracket as a template, mark the hole locations on the wall. Remove the bracket and drill a Ø ⁵ ₁₆" x min. 2" (51mm) deep hole at each hole location. im. "" Insert the plastic anchors in all holes and secure the brackets with the #14 x 2" (chrome plated) screws provided. im. "" urinal plumb line established level line im. "" floor Place the bottom of each urinal screen 18" (457mm) up from floor. Establish a 1" (25mm) gap between the finished wall and urinal screen edge. spacer may help to support the weight of the screen and establish the appropriate distances. E rill Ø ¼" holes through the screen at each bracket hole. Secure the screen to the brackets with #10-24 x ¾" (chrome plated) barrel nuts and #10-24 x ¾" (chrome plated) shoulder screws provided. im. "" im. "" im. "" 15" (381mm) for 42" (1067mm) screens or 18" (457mm) for 48" (1219mm) screens 15" (381mm) for 42" (1067mm) screens or 18" (457mm) for 48" (1219mm) screens 24" (610mm) for 42" (1067mm) screens or 24" (610mm) for 48" (1219mm) screens 14 8/29/2013 radley HWL-INSTR-003 Rev. ; EN 13-14-030

Plastic Laminate Restroom Partitions, eiling-hung Series 600 10a Urinal Screens with ontinuous rackets (Optional) efore installing the urinal screen components, determine the correct location for your application. rackets are used as templates but since the hole patterns may be different, the brackets may not be interchanged. raw a plumb line on all walls representing urinal screen centers. Measure 18½" (470mm) up for 42" (1067mm) tall urinal screens or 21½" (546mm) up for 48" (1219mm) tall urinal screens from the floor and place a mark on the plumb line. Use a level to transfer that mark to all other plumb lines. Using the bracket as a template mark the hole locations on the wall. Remove the bracket and drill a Ø ⁵ ₁₆" x min. 2" (51mm) deep hole at each hole location. Insert the plastic anchors in all holes and secure the bracket with the #14 x 2" (stainless) screws provided. urinal plumb line floor established level line 18½"(470mm) for 42"(1067mm) tall screens or 21½" (546mm) for 48"(1219mm) tall screens E Place the bottom of each urinal screen 18" (457mm) up from floor. Establish a 1" (25mm) gap between the finished wall and urinal screen edge. spacer may help to support the weight of the screen and establish the appropriate distances. Place the bottom of the continuous bracket at the established level line. enter the bracket opening on the plumb line. F rill Ø ¼" holes through the screen at each bracket hole. Secure the screen to the bracket with #10-24 x ¾" (stainless) barrel nuts and #10-24 x ¾" (stainless) shoulder screws provided. radley HWL-INSTR-003 Rev. ; EN 13-14-030 8/29/2013 15