MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

Similar documents
TRANSDUCER IN-LINE AMPLIFIER

TRANSDUCER IN-LINE AMPLIFIER

SENSOTEC UNIVERSAL INLINE TRANSDUCER AMPLIFIER BIPOLAR VOLTAGE MODEL. $!}~ f?(' 7. ()ept 1200 CHESAPEAKE AVE" COLUMBUS OHIO (614)

Model TS. Transducer Simulator User s Guide. Sensotec Sensors

SENSOTEC, INC Arlingate Lane Columbus, Ohio Phone (614) Facsimile (614) Toll Free Free (800)

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Series APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.

BC145 SIGNAL ISOLATOR BOARD

Instruction Manual. HB Series Mini Level Sensor

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

AMP-13 OPERATOR S MANUAL

MODEL AT-10 ANALOG TRANSMITTER

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

SSR VL-12P-xC-NCS

MINCO PRODUCTS, INC Commerce Lane, Minneapolis, Minnesota U.S.A. Telephone: (763) FAX: (763)

TT881 Explosion-Proof Temperature Assembly Installation and Operating Instructions

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

CEC VIBRATION TRANSMITTER

CSG110 Strain Gauge Universal Amplifier

Current Probe Fixture Instruction Manual

SSR V-12C. Industrial Switching Applications: Hellroaring Technologies, inc. P.O. Box 1521, Polson, Montana 59860

Series 3000 Model R-107A

TIC-TAC-TOE Instruction Manual Model #7764

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

Sno-Ball Game Instruction Manual Model #7755-Sno-Ball Insert Model #7757-Alley and Tub

P.O. BOX 1521 POLSON, MT SSR V-12C

Copyright 2014 by Minarik Drives

OPERATION MANUAL LDM-1000

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Instruction Manual Model M Switch, DPDT, Manual Select

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

Signal Isolation Module. Instruction Manual SIM

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

SSR-150xxx-40VL-12P-xC-xxxCS

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

VOLUME CONTROL CONNECTION TERMINAL

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

SX204. Headphone Amplifier. Symetrix. Owner s Manual

Model A-5. Mid Range Wet/Wet Differential Pressure Transducer. A-5, Datenblatt Seite 1 DESCRIPTION FEATURES

Preliminary Data Sheet!

Technical Manual TRANSDUCER AMPLIFIER TYPE S7TW. Doc. Ref CD1210W

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

MODEL 3810/2 Line Impedance Stabilization Network

742A Series Resistance Standards

ZT-4 Tonnage Load Module By Toledo Integrated Systems User s Manual

PCO-7114 Laser Diode Driver Module Operation Manual

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Programmable K-Factor Scaler B and Programming Software Kit B

SETUP SUNSTAR 传感与控制 Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatabilit

Glass Electrode Meter

AMP-12 OPERATOR S MANUAL

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

Model 1791 VHF Radio User's Manual

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

S-4VC/S-6VC. For Connecting Four/Six Pairs of Speakers to an Amplifier or Receiver, with Precise Volume Adjustment in any Zone

Installation and Operating Manual

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

User s Guide Instructions for Installation and Operation

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

WORLD-BEAM QS18AF Sensor with Background Suppression

Precision Frequency To Voltage Converter Card

Broadband Current Probe Series Operation Manual

Model 9305 Fast Preamplifier Operating and Service Manual

MODEL TI196 Current Loop Meter Installation and Operation Instructions

Model RH. Rod End In-line Tension Load Cell DESCRIPTION FEATURES

305 Stimulus Isolator. Description

FP-4855 Flat Panel Television Stand ASSEMBLY INSTRUCTIONS

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Digital Lighting Systems, Inc.

SB.5.1 MODEL STRAIN GAGE CONDITIONER INSTRUCTION MANUAL. Instrument Series

C5000 & C5000NF PULSE INITIATOR. Introduction

Bulk Current Injection Probe Test Procedure

Amplified High Speed Photodetectors

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

HT2 Humidity Transmitter HT2 Humidity and Temperature Transmitter Installation and Operating Instructions

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure

XIA3145 INSTALLATION/OWNER S MANUAL 2/1-Channel Mobile Power Amplifier

Distribution Amplifiers 1

201AP Charge Amplifier User Manual

TSSP-1 (Stainless Steel Thermistor Probe) Manual Rev A

X-PT 5. English. Printed: Doc-Nr: PUB / / 000 / 00

8003 1/8 DIN Temperature Controller

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Tel: (949) Fax: (949) IAA100 Product Manual

DIN Thermocouple Conditioner MODEL 5M14(V)

E7000, E7500, and E ma Analog Transmitters

Transcription:

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT 2080 Arlingate Lane, Columbus, Ohio 43228 (614) 850-5000

Sensotec, Inc. 2080 Arlingate Lane Columbus, Ohio 43228 Copyright 1995 by Sensotec, Inc. all rights reserved Telephone: (614) 850-5000 FAX: (614) 850-1111 Toll Free: 1-800-848-6564 E-mail: sales@sensotec.com WWW: http://www.sensotec.com Model UBP-10, Universal In-line Transducer Amplifier (Bi-polar supply, 0-10 volt output) Sensotec Part Number: 008-0319 - 00 Rev. C: February, 1999 IMPORTANT! IT IS RECOMMENDED THAT YOU READ THIS DOCUMENT THOROUGHLY BEFORE APPLYING POWER TO THIS UNIT. THIS DOCUMENT CONTAINS INFORMATION ON WIRING, CALIBRATION, AND USE OF FEATURES.

Table Of Contents Chapter 1 INTRODUCTION 1.1 Overview.............................. 1-1 1.2 Specifications.......................... 1-2 1.3 Layout................................ 1-3 Chapter 2 INSTALLATION / SETUP 2.1 Wiring................................ 2-1 2.2 Setup................................ 2-3 2.3 Panel Mounting Template................. 2-5 Chapter 3 CALIBRATION 3.1 Calibration............................ 3-1 3.2 Using Shunt Calibration.................. 3-1 Chapter 4 WARRANTY / REPAIR POLICY 4.1 Limited Warranty on Products............. 4-1 4.2 Service Under Warranty.................. 4-1 4.3 Non-Warranty Service................... 4-2 4.4 Repair Warranty........................ 4-2

1.1 Overview Chapter 1 INTRODUCTION Sensotec s Universal In-Line Amplifiers are housed in a small plastic package, which is connected between the transducer and a readout instrument. The Model UBP-10 amplifier supplies a highly regulated bridge excitation voltage for the transducer and converts the millivolt signal of the transducer to a 0-10 volt DC signal. The Universal In- Line features include three selectable excitation voltages, programmable gain settings, a wide adjustment range on the zero and a buffered solid-state shunt cal relay for quick calibration. 008-0319-00 page 1-1

1.2 Specifications Power Requirements: Bridge Excitation: Output Voltage Range: Frequency Response: Zero Balance Range: 24-32 volts DC (with (-)Output voltage = 1/3 of supply) 10, 5, or 3 volts DC @ 70 ma (user selectable) 0-10 volts @ 2 ma DC - 5000 Hz +/- 50% coarse, +/- 15% fine adjustment range Gain Adjustment Range: Switch selectable (1 to 10 mv/v), +/- 25% fine adjust Short Circuit Protection: Environment Protection: Shunt Calibration: Long Term Zero Drift: (+)Output to (-)Output IP-66 or NEMA4 Solid-state relay.1% of Full Scale per 6 months page 1-2 Model UBP-10 Universal In-Line Amplifier

1.3 Layout Figure 1-1: Layout of Model UBP-10 In-Line Amplifier 008-0319-00 page 1-3

page 1-4 Model UBP-10 Universal In-Line Amplifier

2.1 Wiring Chapter 2 INSTALLATION / SETUP The Model UBP-10 Universal In-Line Amplifier (Sensotec p/n 060-6827-06) can be powered from a 24 to 32 volt single voltage supply. The following diagram shows the wiring transducer, power supply and readout. Cables should be stripped back 3 inches with the wires stripped and tinned 1/2 inch. Connections to the terminal block are made by pressing the orange levers and inserting the wires into the holes next to the levers. The terminal block will accept wire up to AWG 20. Install a shunt cal resistor with the value specified on the transducer data sheet. Figure 2-1: Transducer to In-Line Wiring 008-0319-00 page 2-1

Figure 2-2: 24 to 32 Single Voltage Supply to In-Line Wiring NOTE: For the single voltage supply, (-)OUTPUT is biased approximately 1/3 of the supply voltage. The output will swing 0-10 VDC around the (-)OUTPUT reference voltage. page 2-2 Model UBP-10 Universal In-Line Amplifier

2.2 Setup Use the following procedure for setting up the excitation and the coarse gain: 1. Determine the EXCITATION VOLTAGE required by the transducer being used. 2. Set the EXCITATION SELECT JUMPER as shown below: (See Fig.1-1 for location of jumpers) 3. Determine the sensitivity of the transducer in mv/v from the transducer calibration sheet. 4. Set the COARSE GAIN SWITCH (See Fig.1-1 for location of switch) to the nearest mv/v setting in the corresponding excitation column in Table 1. 008-0319-00 page 2-3

Table 1: Coarse Gain Setup SWITCH POSITION ON EXCITATION (VDC) 10 5 3 1 1 mv/v 2 mv/v 3.2 mv/v 2 & 3 & 5 1.2 mv/v 2.4 mv/v 4 mv/v 2 & 4 1.5 mv/v 3.0 mv/v 5 mv/v 2 2 mv/v 4 mv/v 6.6 mv/v 3 & 6 2.5 mv/v 5 mv/v 8.32 mv/v 3 3.0 mv/v 6 mv/v 10 mv/v 4 & 7 3.5 mv/v 7 mv/v 11.6 mv/v 4 4 mv/v 8 mv/v 13.2 mv/v 5 & 8 4.5 mv/v 9 mv/v 15 mv/v 5 5 mv/v 10 mv/v 16.6 mv/v 6 6 mv/v 12 mv/v 20 mv/v 7 7 mv/v 14 mv/v 23.2 mv/v 8 8 mv/v 16 mv/v 26.6 mv/v page 2-4 Model UBP-10 Universal In-Line Amplifier

2.3 Panel Mounting Template The Universal In-Line Amplifier can be easily mounted to a panel by using the template below for marking the holes in the panel. The cover must be removed to get access to the mounting holes. Use # 6 or # 8 screws for mounting box to panel. Figure 2-3: Panel Mounting Template 008-0319-00 page 2-5

page 2-6 Model UBP-10 Universal In-Line Amplifier

3.1 Calibration Chapter 3 CALIBRATION Step 1. Apply power and allow unit to stabilize for 10 minutes. Step 2. With zero load or pressure on the transducer, adjust the ZERO potentiometers to indicate zero on the readout instrument or voltmeter connected to the output. Step 3. Apply full scale pressure or load to the transducer and adjust the SPAN potentiometer to indicate full scale on the readout instrument or voltmeter. Step 4. Re-check zero and full scale (repeat steps 2 & 3). 3.2 Using Shunt Calibration Sensotec transducers feature a calibration technique called shunt calibration. This method applies a known resistance across one leg of the transducer, which simulates an output as if a load or pressure was applied to the transducer. When performing shunt calibration, the transducer should be at ZERO pressure or load. The full scale output and shunt cal output is found on the TRANS- DUCER CALIBRATION SHEET. This information can be used to calibrate the amplifier s output voltage and the readout s display with the following equations. 008-0319-00 page 3-1

TRANSDUCER CALIBRATION DATA Full Scale Output = mv/v. Shunt Resistor Value of Ohms Shunt Cal Output = mv/v. The following equations are used to calculate output voltage and display units: FORMULA TO CALCULATE OUTPUT VOLTAGE SHUNT CAL OUTPUT FULL SCALE OUTPUT X 10V = OUTPUT VOLTAGE X 10V = FORMULA TO CALCULATE DISPLAY UNITS SHUNT CAL OUTPUT FULL SCALE OUTPUT X FULL SCALE UNITS = DISPLAY UNITS X = Step 1. Apply power and allow the amplifier to warm up. Step 2. With zero load or pressure on the transducer, adjust the ZERO potentiometer to indicate zero on the readout instrument or voltmeter. page 3-2 Model UBP-10 Universal In-Line Amplifier

Step 3. Connect a jumper across PINS 5 & 6 of the power terminals (See Fig. 1-1) or wire in a switch as shown in wiring section. Adjust the SPAN potentiometer to the calculated voltage or calculated units on the readout instrument or voltmeter. Step 4. Disconnect the shunt cal jumper or release the shunt cal switch and repeat steps 2 & 3 if needed. 008-0319-00 page 3-3

page 3-4 Model UBP-10 Universal In-Line Amplifier

Chapter 4 WARRANTY / REPAIR POLICY 4.1 Limited Warranty on Products Any of our products which, under normal operating conditions, proves defective in material in workmanship within one year from the date of shipment by SENSOTEC, will be repaired or replaced free of charge provided that you obtain a return material authorization from SENSO- TEC and send the defective product, transportation charges prepaid with notice of the defect, and establish that the product has been properly installed, maintained, and operated within the limits of rated and normal usage. Replacement product will be shipped F.O.B. our plant. The terms of this warranty do not extend to any product or part thereof which, under normal usage, has an inherently shorter useful life than one year. The replacement warranty detailed here is the buyer's exclusive remedy, and will satisfy all obligations of SENSO- TEC whether based on contract, negligence, or otherwise. SENSO- TEC is not responsible for any incidental or consequential loss or damage which might result from a failure of any SENSOTEC product. This express warranty is made in lieu of any and all other warranties, express or implied, including implied warranty of merchantability or fitness for particular purpose. Any unauthorized disassembly or attempt to repair voids this warranty. 4.2 Service Under Warranty Advanced authorization is required prior to the return to SENSOTEC. Before returning the items, either write to the Customer Service Department c/o SENSOTEC, Inc., 2080 Arlingate Lane, Columbus, Ohio 43228, or call (800) 848-6564 with: 1) a part number; 2) a serial number for the defective product; 3) a technical description* of the defect; 4) a no-charge purchase order number (so products can be returned to you correctly); and 5) ship and bill addresses. Shipment to SENSOTEC shall be at Buyer's expense and repaired or replacement items will be shipped F.O.B. our plant in Columbus, Ohio. Nonverified problems or defects may be subject to an evaluation charge. Please return the original calibration data with the unit. 008-0319-00 page 4-1

4.3 Non-Warranty Service Advance authorization is required prior to the return to SENSOTEC. Before returning the item, either write to the Customer Service Department c/o SENSOTEC, Inc., 2080 Arlingate Lane, Columbus, Ohio 43228, or call (800) 848-6564 with: 1) a model number; 2) a serial number for the defective product; 3) a technical description* of the malfunction; 4) a purchase order number to cover SENSOTEC's repair cost; and 5) ship and bill addresses. After the product is evaluated by SENSOTEC, we will contact you to provide the estimated repair costs before proceeding. Shipment to SENSOTEC shall be at Buyer's expense and repaired items will be shipped to you F.O.B., our plant in Columbus, Ohio. Please return the original calibration data with the unit. 4.4 Repair Warranty All repairs of SENSOTEC products are warranted for a period of 90 days from date of shipment. This warranty applies only to those items which were found defective and repaired, it does not apply to products in which no defect was found and returned as is or merely recalibrated. Out of warranty products may not be capable of being returned to the exact original specifications or dimensions. * Technical description of the defect: In order to properly repair a product, it is necessary for SENSOTEC to receive information specifying the reason the product is being returned. Specific test data, written observations on the failure and the specific corrective action you require is needed. page 4-2 Model UBP-10 Universal Inline Amplifier