HI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date

Similar documents
This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

High Performance Current Transducer ITL 900-T = A

High precision measurement system for current and voltage IHC-A/B-RM01/03

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

LEAK CURRENT HiTESTER ST5540/ST Washington Street Melrose, MA Phone Toll Free

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

38 Series - Relay Interface Modules A

LED Driver Linear / area fixed output

Laboratory Accreditation Programmes

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

E Series 9.00 (1/2) E series

Page 2 of 69 VDE Report No.: / DC - DC Converter for building in. TDK Innoveta Inc. iba - Series (see model matrix appendix 1)

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

LED Driver Linear / area fixed output

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

38 Series - Relay interface modules A. Features /

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

Technical Data Sheet. Zeta 20

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

SUBJECT TO CHANGE WITHOUT NOTICE

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

BIODEX MULTI- JOINT SYSTEM

LFWLP W 12V 15.00A 25.00A 92%

satech SynchroStar GPS 200 Series

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

V P N. Voltage transducer DVM 4200 = 4200 V

ASHIDA Numerical OC/EF Protection Relay

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

Control Cable installation: Best Practice

Power supply CP-D 24/4.2 Primary switch mode power supply

Transformers, Power Supply Units and Socket Outlets

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Technical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

38 Series - Relay interface modules A

38 Series - Relay interface modules A

V P N. Voltage transducer DVL 1000 = 1000 V

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

79/26 Series III Multimeter

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Technical Specifications Micromedical VisualEyes 505 by Interacoustics

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

BENNING. CM7 Electrical Tester. Service Information

LED Driver Compact dimming

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

GAMMA 20 DIGITAL MULTIMETER

Multi-voltage Multi-function. Wiring diagram (without control signal)

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

V P N. Voltage transducer DVM 2000-B = 2000 V

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MID energy meter B21 Single-phase energy meter, 65 A

HVR. Lead Wire Length (H, mm)

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

Transcription:

Last Amended on - Page 1 of 14 I. AUDIO EQUIPMENT 1. Audio-Video and Similar Electronics Apparatus Safety Requirement Marking & Instructions Laser Radiation (Products Marked Class I only) Heating under normal Operating Condition Constructional requirement with regard to the protection against electric shock Electric Shock Hazards under normal operating Conditions Insulation Requirements Surge Test Humidity Treatment Insulation Resistance and Dielectric Strength Test Fault Conditions IEC 60065:2005 (Cl. 5) IEC 60065:2005 (Cl. 6.2) IEC 60065:2005 (Cl.7) Except 7.2 IEC 60065:2005 (Cl.8) IEC 60065:2005 (Cl.9) IEC 60065:2005 (Cl.10) IEC 60065:2005 (Cl.11) 0 to 400 C 0.001 to 11.11x10 6 MΩ 0 to 100 C, 20 to 99% Rh 0.01 to 200mm 0.01kV to 5kVac/dc 0 to 30N 10 Hz to 55Hz to10hz, 0.35mm 40 to75v, 0 to 75 N 0.001V to 1000Vac/dc 1µA to 20 Ma 0.01 kv to 15 kv 0 to100 C, 20 to 99% Rh 0.01 to 5kV ac/dc 100 kω to 2 GΩ 0 to 400 C 0 to 1000Vac/dc

Last Amended on - Page 2 of 14 Mechanical Strength IEC 60065:2005 (Cl.12) Clearances & Creepage (Cl. 13) IEC 60065:2005 Batteries (Cl. 14.10) IEC 60065:2005 Terminal (Cl. 15) IEC 60065:2005 External flexible Cords IEC 60065:2005 (Cl. 16) 0 to 9999 Counts 10 g to 20 kg 0.01mm to 200 mm Upto 6.0 Nm Torque & 0.5 Nm for Spring Hammer 2 Joules 10 Hz to 55Hz to 10 Hz 0.35mm, 0 to 199.9 C 0.05 mm to 1 mm 0.01mm to 200 mm 0 to1000 Vac/dc 0.001V to 100V 1 µa to 10 A ac/dc 0 to 6 Nm 0.01 mm to 200mm 0.01 A to 50A, 0.01 to19.99 C` 0.001 mm to 25 mm 0.01 mm to 200 mm 40 N, 0.25 Nm Connection & Mechanical Fixings IEC 60065:2005 (Cl. 17) 0 to 6 Nm 0 to 30 N Stability & Mechanical Hazards IEC 60065:2005 (Cl. 19) Resistance to fire IEC 60065:2005 (Cl. 20) Inclination 0 to 20 Force 0 to 250 N Mass 20N, Ball Ø 5mm 0 to 500 Vac, 9.5 mm 1ms to 99.99 min

Last Amended on - Page 3 of 14 II. IT EQUIPMENT 1. Safety of information technology including electrical business General Components Power Interface IEC 60950-1 :2005 IEC 60950-1 :2005(Cl. 1.6) Voltage AC 0.05 V to 500V DC 0.01V to 300 V Current AC 0.001A to 20A DC 0.001A to 5A Power: 0.1W to 2000W Markings & Instructions IEC 60950-1 :2005 (Cl.1.7) Protection from Hazards Protection from Electric Shock & Energy Hazards IEC 60950-1 :2005 (Cl. 2.1) 40V to 75V, 0 to 75N 0 to 5 kv ac/dc, (100k to 2G) Ω 0.05 mm to 1 mm, 0.01 mm to 200 mm SELV Circuits IEC 60950-1 :2005 (Cl. 2.2) Voltage AC/ DC 0.01 V to 1000V Current AC/ DC 0.001 V to 10 A TNV Circuits IEC 60950-1 :2005 (Cl. 2.3) Voltage AC/ DC 0.01 V to 1000 V Current AC/ DC 0.001 A to10 A 0.01 to 5kV ac/dc

Last Amended on - Page 4 of 14 Safety of information technology including electrical business Limited Current Circuits Limited Power Sources IS 13252 (Part1): 2010 IEC 60950-1 :2005 (Cl. 2.4) IEC 60950-1 :2005 (Cl. 2.5) Current AC/ DC 0.001 A to10 A & Visual Examination Voltage AC/ DC 0.01V to 1000 V Current AC/ DC 0.001 A to 10 A Provision for earthing and bonding IEC 60950-1 :2005 (Cl. 2.6) 0 to 50 A, 19.99 V 0.001 mm 2 25 mm 2 0.001-5 ohms Over-current and earth fault protection in primary circuits IEC 60950-1 :2005(Cl. 2.7) Insurances IEC 60950-1 :2005 (Cl. 2.9) 0 to 100 C, 20 to 99% Rh 0 to 5kV Clearances, Creepage distances and distances through insulation IEC 60950-1 :2005 (Cl. 2.10) 0.05 mm to 1 mm, 0.01 mm to 200 mm 0.01 kv to 15 kv 0.01 to 5 kvac/dc 0 to100 C, 20 to 99%Rh

Last Amended on - Page 5 of 14 Safety of information technology including electrical business Wiring Connection and Supply General Connections to mains Supply IEC 60950-1 :2005(Cl.3.1) IEC 60950-1 :2005 (Cl. 3.2) Voltage AC/ DC 0.01 to 1000V 0.001mm to 25 mm 0.01mm to 200 mm 0.01 kvac/dc to 5 kvac/dc kvac/dc 0 to 100N Wiring Terminals for external conductors IEC 60950-1 :2005 (Cl 3.3) 0 to 400 C 0.001mm to 25mm 0.01mm to 200mm Disconnections from the main Supply IEC 60950-1 :2005 (Cl 3.4) Interconnection of IEC 60950-1 :2005(Cl. 3.5) Physical Requirements Stability / IEC 60950-1 :2005 (Cl.4.1) Inclination 0 to 20, Force 0 to1000 N Mechanical Strength / IEC 60950-1 :2005 (Cl. 4.2) 0 to 250 N, 0 to 1000 N 0 to 199.9 C Design & Construction:(Cl. 4.3) Batteries (Cl. 4.3.8) Human Exposure to UV Radiation only / IEC 60950-1 :2005 (Cl. 4.3.13.4) 0 to 100N, 0.25 Nm Voltage AC/DC 0.01 V to 100 V/ 1µA to 5 A

Last Amended on - Page 6 of 14 Safety of information technology including electrical business Protection against hazardous moving parts Thermal Requirements Opening in Enclosure IEC 60950-1 :2005 (Cl.4.4) IEC 60950-1 :2005 (Cl. 4.5) IEC 60950-1 :2005 (Cl.4.6) 0 to 100N 0 to 199.9 C 0 to 400 C 10 mω to 1MΩ (-)50 C to 100 C 0.01to 200 mm Resistance to fire IEC 60950-1 :2005 (Cl. 4.7) 0 to 1350 C Mass 20 N, BallØ5 mm 0-500 c, 9.5mm 1 ms to 99.99 min requirements & simulated abnormal conditions Touch current & protective conductor current IEC 60950-1 :2005 (Cl. 5.1) 1µA to 20mA Electric Strength Test IEC 60950-1 :2005 (Cl. 5.2) 0.01 to 5kV ac/dc Abnormal operating & fault conditions IEC 60950-1 :2005 (Cl. 5.3) 0 to 400 C 10 mω to 1 MΩ 1 µa to 20 ma Connections to Telecommunication network IEC 60950-1 :2005 (Cl. 6.1, 6.2, 6.3) 0.01 to 5kV ac/dc 100 kω to 2 GΩ 0.01 V to1000 V/ 0 to 10A ac/dc Connection to cable Distribution System (Cl. 7.1, 7.2,7.3, 7.4) IEC 60950-1 :2005 0.01 to 5 kv ac/dc 0.01 kv to 15 kv

Last Amended on - Page 7 of 14 III. 1. 2. EMI TEST FACILITY Self-ballasted lamps for general lighting Services lighting and similar Radio Interference/ Disturbance Measurement (Conducted & Magnetic field Radiated emission) IS 15111 (Part 2):2002 IEC 60969 ed1.2:2001 IS 6873 (Part 5):2012 CISPR 15:2009 EN 55015 (Cl. no. 4.3.1) Conducted and Radiated (Magnetic Field) 9 khz to 30 MHz 20 db µa to 100 db µa 150 khz to 30 MHz 20 db µa to120 db µa 3. 4. AC static Watt Hour meter AC static transformer operated watt hour & VAR-Hour meter IS 13779:1999 IEC 62053-1:2003/CBIP 304 IEC 62052-11:2003 IS 14697:1999 IEC 62053-22:2003 IEC62053-23:2003 IEC 60255-25:2000 Conducted and Radiated (Magnetic Field) 9 khz to 30 MHz 20 db µa to100 db µa 150 khz to 30 MHz 20 db µa to 120 db µa 5. Measuring relays & protection IS 60947 (Part 5/Sec1): 2003 IEC 60947-5-1:2009 IEC 60204-1:2005 6. Electromechanical control circuit devices 7. of machines

Last Amended on - Page 8 of 14 8. 9. 10. 11. 12. Electronic used on rail vehicles Medical electrical (Table 201) for measurement, control and laboratory use Uninterruptible power systems (Cl. No. 2.4.1) measuring transducers for converting ac electrical Quantities into dc electrical quantities IEC 60571:2006 IEC 60601-1-2:2007 IEC 61326-1:2005 IEC 62040-2:2005 IS12784 (Part 1): 1989 IEC:60688:2002 IEC 61000-6-3:2011 IS 6873(P-2/Sec-1):2012 CISPR 14-1:2011 (Cl. No 4.1.1) IS 6873(Part-3):2009 CISPR 13:2009 (Cl. No. 4.2) IS 6873 (Part 4):2009 CISPR 11:2009/ EN 501:1999 (Cl. No. 5.1) IS 6873(Part -7):1999/ CISPR 22:2008/EN 55022 (Cl. No. 5.1) Conducted and Radiated (Magnetic Field) 9 khz to 30 MHz 20 db µa to 100 db µa 150 khz to 30 MHz 20 db µa to 120 db µa

Last Amended on - Page 9 of 14 IV. SAFETY TESTING FACILITY 1. i) Safety of house hold & Similar (read in for Microwave Oven) ii) Safety of house hold & Similar read in for clock. Marking Protection Against Electric Shock Starting Of Motor Operated Appliances Input and Current Temperature Rise Clause-7 Clause-8 IS:302-1:2008 & Clause-9 IS:302-1:2008 & Clause-10 Clause-11 0 to 60V (AC) 0 to 75 N 0 to 12 kw 0 to 12 kw 0 to 400 C

Last Amended on - Page 10 of 14 insulation and Leakage Current at Operating Temperature Clause-13 0 to 1999µA 0 to 199.9mA 0 to 5 kv, 200mA (100 to 2G) iii) Safety of house hold & Similar read in for Microwave Oven. iv) Safety of house hold & Similar read in for clock. Radio & Television Interference Suppression (Transient Over Voltage test) Moisture Resistance Test Insulation Resistance and Electric Strength (After Humidity treatment) Clause-14 IS 302-1:2008 & IS 302-1:2008 & Clause-15 Clause-16 Upto 15 kv 0-100 C, 20-99% Rh 0 to 1999 µa 0 to 199.9 ma 0 to 5kV, 200 ma (100 to 2G) Ω Overload Protection Clause-17 0 to 400 C 0 to 300V/0 to 30A Upto 12 kw

Last Amended on - Page 11 of 14 Endurance Test Clause-18 0 to 12 kw, 0 to 9999 h Upto 100000 cycle Abnormal Operation Clause-19 0 to 400 C Stability and Mechanical Hazards Clause-20 Inclination 0 to 20 Weight 22.5kg, 7kg, 3.5kg Mechanical Strength Clause-21 0 to 9999 Counts 10g to 20kg 0 to 200mm, 0 to 25mm Up to 5 Nm Torque &1 Nm for Spring Hammer v) Safety of house hold & Similar read in for Microwave Oven. Construction xvi) Internal Wiring Clause-22 IS:302-1:2008 & Clause-23 0 to 100W/m 2 and Visual and Physical Test

Last Amended on - Page 12 of 14 vi) Safety of house hold & Similar Section 26 read in for clock. xvii) Components xviii) Supply Connection And External Flexible Cords Clause-24 IS 302-1:2008 & Clause-25 0 to 99999 Counts xix) Terminal For External Conductor Clause-26 0 to 5 Nm 0.01 to 200 mm xx) Provision For Earthing Clause-27 0 to 19.99V 0 to 50A xxi) Screws and Connections Clause-28 0 to 5Nm

Last Amended on - Page 13 of 14 vii) Safety of house hold & Similar Section 25 read in for Microwave Oven. viii) Safety of house hold & Similar read in for clock. xxii) Creepage distances and Clearances xxiii) Resistance to heat, Fire and Tracking xxiv) Resistance to Rusting Clause-29 Clause-30 IS:302-1:2008 & Clause-31 IS 302-1:2008 & 0.05 mm to 1mm 0.01mm to 200 mm 0 to 1350 C 0 to 40 C, 0 to 100 C 20 to 99% Rh

Last Amended on - Page 14 of 14 Radiation Hazards Clause-32 0 to 10 mw/cm 2 -X-X-X-X-X-X-X-X-X-X-X-X-X-X-