G81 PART 1 FRAMEWORK APPENDIX

Similar documents
Company Directive STANDARD TECHNIQUE: SD5F. Relating to connecting multiple small low voltage connections with limited network analysis

Company Directive STANDARD TECHNIQUE: SD5R/2. Earth Fault Loop Impedances and Phase to Neutral Loop Impedances at LV Installations

ELECTRIC NETWORK DESIGN APPROVAL APPLICATION

Company Directive STANDARD TECHNIQUE: SD7F/2. Determination of Short Circuit Duty for Switchgear on the WPD Distribution System

Company Directive STANDARD TECHNIQUE: SD1E/2. Technical Requirements for Customer Export Limiting Schemes

Company Directive POLICY DOCUMENT: SD4/7. Relating to 11kV and 6.6kV System Design

STANDARD TECHNIQUE: SD4A/1

WESTERN POWER DISTRIBUTION

EDS LV NETWORK DESIGN

Table of Contents. Introduction... 1

FAQ ON EARTHING STANDARDS 16/08/2018

STANDARD TECHNIQUE : SD4T

Section 1.0: Introduction. Section 3.0: Planning. Section 4.0: Power Quality. Manual 0295 Supply & Planning Manual Updated: 01/08/2017

Click to edit Master title style. Click to edit Master title style. Northern Powergrid Asset Recording Guidance

MV network design & devices selection EXERCISE BOOK

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS

Licensed Electricians Practical Assessment (LEP)

Company Directive STANDARD TECHNIQUE: TP21D/2. 11kV, 6.6kV and LV Earthing

GRID INTERCONNECTION OF EMBEDDED GENERATION. Part 2: Small-scale embedded generation

Licensed Electricians Practical Assessment (LEP)

Australian Standard. Switchgear assemblies and ancillary equipment for alternating voltages above 1 kv AS

TS RES - OUTSTANDING ISSUES

POWER SYSTEM ANALYSIS TADP 641 SETTING OF OVERCURRENT RELAYS

Earthing Requirements for HV Transmission Structures

kv AC substation

Protection of Electrical Networks. Christophe Prévé

Chapter 6. WIRING SYSTEMS Safe Electrical Design

Company Directive STANDARD TECHNIQUE: TP14C. Distribution Business Provided Metering Facilities

Collection of standards in electronic format (PDF) 1. Copyright

Embedded Generation Connection Application Form

Connection Impact Assessment Application

Course 11 Distribution Transformer Applications Instructor: David R. Smith, PE Due: April 24, 2017 (EV), April 25, 2017 (LC)

Energy Networks Association

Distribution Code. Approved by CER. Version: 5.0 Date: April Distribution System Operator ESB Networks Limited

Equipment Description Quantity as per drawings Actual quantity

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

Electrical Description

SPTS 1 - Ratings and General Requirements for Plant, Equipment and Apparatus for The ScottishPower System and Connection Points to it.

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

Company Directive STANDARD TECHNIQUE: TP6F/1. Power Measurement Conventions

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

Embedded Generation Connection Application Form

Distribution transformers Part 2 Ground mounted transformers not closecoupled

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

TABLE OF CONTENT

FACILITY RATINGS METHOD TABLE OF CONTENTS

STANDARD TECHNIQUE : SD7A/6

(Circuits Subject to Requirements R1 R5) Generator Owner with load-responsive phase protection systems as described in

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

Company Directive ENGINEERING SPECIFICATION EE SPEC: 5/5. Relating to 11kV Distribution Transformers

IMP/010/011 Code of Practice for Earthing LV Networks and HV Distribution Substations

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

COMMISSION REGULATION (EU) No /.. of XXX

Impact Assessment Generator Form

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

NZECP 36:1993 ISSN COVER PAGE

SINGLE-PHASE VSV SWITCH

Company Directive STANDARD TECHNIQUE : TP21A/2. Relating to Safety Limits for Touch and Step Voltages - Earthing System Design/Assessment

Calculating and compensating for power transformer and cable (or line) losses - standard methods

Earthing Guidance Notes

ATTACHMENT - AESO FUNCTIONAL SPECIFICATION

CUSTOMER SUPPLIED HIGH VOLTAGE METERING UNIT SPECIFICATION FOR 11, 22 & 33 kv

Standard Development Timeline

Busway Design The Easy Way. By: IIEE-ABU DHABI CHAPTER

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

ER 87 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) ESR 27(2) (2 marks) ESR 74A(1AA)

S&C Vista Underground Distribution Switchgear Outdoor Distribution

Functional Specification Revision History

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011

ECP HV METERING EQUIPMENT COMMISSIONING PROCEDURE

Manual: Distribution Substation Manual (DSM) Section D: Substation Drawing Revision List

Customer Standard. Standard for Embedded Generation (5MW and above)

Connection of Embedded Generating Plant up to 5MW

Status Date Prepared Reviewed Endorsed Approved

3-phase short-circuit current (Isc) at any point within a LV installation

Fatima Michael college of Engineering and Technology

DESIGN PRACTICE NOTE DESIGN/REVIEW REQUIREMENTS FOR TRACTION BONDING PLAN

, Power Industries and Communications Industry Training Board

DESIGN OF A 45 CIRCUIT DUCT BANK

EDS LV WAVEFORM MAINS CABLE RATINGS

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

LOVAG GENERAL INSTRUCTION G2 MEASUREMENT UNCERTAINTY. This instruction of a general nature and does not relate to specific standards.

IMP/007/011 - Code of Practice for the Application of Lightning Protection

EDS FAULT LEVELS

Embedded Generation Connection Application Form

Balancing and Settlement Code. Code of Practice Two

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

CELLULES MEDIUM VOLTAGE

Back to the Basics Current Transformer (CT) Testing

Short-Circuit Current Calculations

WITHDRAWN JULY Manual: Distribution Substation Manual (DSM) Section I: Introduction

Chapter G Sizing and protection of conductors

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

OPERATING CODE NO. 5 (OC5)

QUESTIONNAIRE for Wind Farm Power Stations only

Transcription:

G81 PART 1 FRAMEWORK APPENDIX Housing Development design framework appendix to be read in conjunction with the latest version of: ENA Engineering Recommendation G81 Part 1 Framework for design and planning, materials specification and installation and record for low voltage housing development installations and associated, new, HV/LV distribution substations Part 1 Design and Planning. Page 1

WESTERN POWER DISTRIBUTION HOUSING DEVELOPMENT DESIGN FRAMEWORK DLH SPECIFIC APPENDIX 1.0 INTRODUCTION 1.1 This G81 Framework Annex specifies Western Power Distribution s requirements for design and planning of low voltage housing developments. This document shall be read in conjunction with: The National Framework Documents The Adoption Agreement Western Power Distribution (WPD) Housing Development Framework Appendices relating to installation and materials WPD Framework Appendix on cable recording techniques WPD Standard Technique ST:SD5A/1: the design of LV domestic connections WPD Standard Technique ST:SD5R/3: earth fault loop impedances and phase to neutral loop impedances at LV installations WPD Standard Technique ST:TP21D: 11kV, 6.6kV and LV system earthing WPD Standard Technique ST:SD8B Part 1: LV cable ratings 1.2 Implementation requirements are given in Annex 1 1.3 The change history for this document (since issue B) is included in Annex 2. 1.4 In the event of query please speak to the WPD Planner acting as the focal point of contact for the scheme. 2.0 INFORMATION REQUIRED FROM APPLICANT The following information shall be provided by the applicant with the design: 2.1 For each feeder Number of customers and connections on each phase Maximum imported feeder demand in Amperes Maximum exported feeder demand in Amperes Fuse selected and maximum clearance time ph to earth fault at cut out Maximum voltage regulation (% of nominal voltage) at cut out positions, at the connection point and at the end of each section of mains (i.e.at each mains tee). Values shall be given for maximum for voltage drop and also maximum voltage rise, where this applies Maximum earth fault loop resistance (ohms), at end of each mains tee and at each cut-out position Maximum voltage unbalance (%) Diversity (%) Maximum length of cable in duct Maximum number of services from one mains joint Page 2

2.2 Demand assumptions A listing of demand profile classes and ADMDs/ annual consumption used for each category of service 2.3 Information (as required in Distribution Code - DPC 5.2.1), on Individual maximum power requirements kva or kw Type and electrical loading of equipment to be connected, e.g. number and size of motors, cookers, showers, generators, heat pumps, space and water heating arrangements including details of equipment which is subject to switching by the Supplier 2.4 Economic Rating Criteria The criteria that has been used to assess the capitalised cost of transformer losses for the purposes of selecting transformer types and sizes: Capitalised cost of variable (copper) losses ( /Watt), based on maximum copper losses when the transformer operates at its nameplate rating. Capitalised cost of fixed (iron) losses( /Watt) 2.5 Maximum design PSCCs at connection of service to main (ka) 1ph 230V 3ph 230/400V 2ph 230/460V 2.6 Design PSCC at LV busbars of HV/LV transformer (ka) 2.7 Unmetered supplies Classes and maximum demands (in accordance with the Unmetered Supplies Operational Information published by Elexon). 2.8 Confirmation that cable ratings employed are as WPD ratings (defined in ST:SD8B Part 1). 2.9 A layout plan, typically to scale 500/1, ( the as laid plan shall be no smaller scale than 500/1) showing the proposed route and types of all cables, identifiable by feeder, locations of points of supply, link boxes, substation positions etc. 2.10 Tenure - Means by which cable routes and substation sites are to be secured, e.g. public highway, easement etc. Page 3

3.0 WPD DESIGN REQUIREMENTS 3.1 WPDs design requirements are specified in Standard Technique (ST):SD5A 3.2 Maximum PSCCs at connection of service to main 1ph 230V 16 ka 3ph 230/400V 25 ka 2ph 230/460V 25 ka 3.3 Cost of Losses WPD apply the following transformer loss evaluation when assessing the lifetime costs of transformers: Capitalised value of variable (i.e. copper) losses = 0.243/Watt (based on maximum copper losses when operating at name plate rating). Capitalised value of fixed (i.e. iron) losses = 1.791/Watt. In addition to the above, transformer losses shall not exceed the maximum values defined in EE SPEC:5. 3.4 Underground cable ratings - criteria for underground cables Underground cable ratings specified in ST:SD8B Part1 and Part 2 shall be used. The choice of spring, summer, autumn or winter ratings and the use of continuous or cyclic ratings is determined by the nature and the time of year of the load. Typically autumn cyclic ratings are applicable to housing estate designs. Distribution ratings shall not be used for design purposes. A duct up to 15m in length can be used without de-rating the cable. Two or more duct lengths can be used on a section, provided that there is no more than 30m of duct in a particular 250m cable section and that there is a minimum of 10m separation between each duct length. The duct rating shall be used if 15m or more of continuous duct is installed on a particular 250m cable section. Page 4

ANNEX 1 A1 IMPLEMENTATION For a period of 3 calendar months from the date of issue of this document ICPs may either comply with the previous issue (Issue B) or this version (). This document shall be implemented in full 3 calendar months after the date of issue. Page 5

ANNEX 2 A2 CHANGE HISTORY A summary of the changes included since Issue B of this document are included below: Clause / Description Paragraph changes (April 2012) 1.1 References to the following documents added: WPD ST:SD5A WPD ST:SD5R WPD ST:TP21D WPD ST:SD8B Part 1 1.2 New clause referring to Annex 1 (Implementation) added. 1.3 New clause referring to Annex 2 (Change History) added. 1.4 Existing clause 1.2 re-numbered as 1.4. 2.1, 2 nd bullet Changed to maximum imported demand. 2.1, 3 rd bullet Maximum exported demand added. 2.1, 5 th bullet Voltage regulation wording clarified. 2.1, 6 th bullet Earth fault loop impedance at cut-out positions added. 2.3, 2 nd bullet Generators and heat pumps added. 2.7 Reference to BSCP 520 replaced with reference to Unmetered Supplies Operation Information published by Elexon. 2.8 Reference to ST:SD8B Part 1 added. 3.0 The following clauses (from Issue B) have been removed and replaced by the reference to ST:SD5A: 3.1 Voltage Regulation 3.2 Maximum earth loop impedance 3.5 LV Generation connections 3.6 Services 3.7 Demands 3.8 Voltage unbalance 3.10 HV/LV transformer ratings 3.11 HV/LV substations 3.12 LV protection 3.13 Provision for connecting LV generation to LV fuse boards / cabinets / pillars. 3.1 Clause referring to ST:SD5A added. 3.2 Existing clause 3.3 re-numbered as 3.2. 3.3 Existing losses clause 3.4 amended and re-numbered as 3.3 3.4 Existing clause 3.9 on LV cable ratings is replaced by clause 3.4. The new requirements refer to ST:SD8B Part 1. Annex 1 New implementation Annex added. Annex 2 New change history Annex added. Page 6