vacon nxs robust drive for heavy use

Similar documents
vacon nx all in one application manual ac drives Phone: Fax: Web: -

NX Series Inverters. HVAC Pocket Programming Guide

NX series Constant and variable torque Variable Speed Drives for induction motors

ACH550 HVAC Drive Submittal

vacon nx ac drives all in one application manual

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

SX (400 V) System configuration

SX (690 V) System configuration

SX (400V) System configuration

vacon nxp and nxc superlative performance

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1.

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Inverter Drive /Vector Drive Motors & Controls

Fan and Pump AC Inverter

vacon 100 flow ac drives application manual

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Multi-purpose Control Application II

user's manual nx frequency converters beam pump application asfiff13

vacon 100 flow ac drives application manual

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

S11 Adjustable Speed Drive Engineering Specification

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

General Purpose Drives

Emotron FDU 2.0 Variable Speed Drive

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

Emotron FDU 2.0 Variable Speed Drive

1. INTRODUCTION Fire Mode PID Application Parameter lists DESCRIPTION OF PARAMETERS... 8

VF-nC1 Adjustable Speed Drive Engineering Specification

NEWPCC VARIABLE FREQUENCY DRIVES Section LAB RENOVATION BID OPPORTUNITY NO PAGE 1 OF SCOPE

E3 Adjustable Speed Drive Engineering Specification

Design Characteristics. FlexDrive II. Series

user's manual nx frequency converters standard lift application asfiff08

Comp-AC. User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw

ADJUSTABLE SPEED DRIVES. AS1 Drive

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

vacon nxp arfiff30 user manual generator application ac drives

water solutions NX frequency converters applications manual

User's Guide for type ACS55 AC Drives from 0.18 to 2.2 kw

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

Dynamic drives for low power AC motors

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

Manual Overview...1 2

ADJUSTABLE SPEED DRIVES FS1

vacon 100 ac drives application manual

vacon 10 ac drives quick guide

Lexium integrated drives

Drive IT Low Voltage Drives. User's Guide for type ACS50 AC Drives from 0.18 to 0.75 kw

nx frequency converters shaft synchronization application apfiff11 user's manual

vacon nx water solutions application manual ac drives

Vacon 100 Flow Course

General Purpose AC Drives

SV9000 SVReady USER MANUAL CONTENTS OPEN SV9000 USER MANUAL. SV9000 Page 0-1

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

AF91 Adjustable Frequency Drives Series B

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

vacon 100 hvac ac drives application manual

Honeywell. User Manual. SmartVFD COMPACT. Variable Frequency Drives for Constant and Variable Torque Applications

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Altivar 28 drive Altivar 28 enclosed drive

PowerGard Series C 18-Pulse Enclosed Drive Controllers

VarioTrane TR1. Series 2800 TR1-PRC002-E4

This Chapter contains:

General Specifications FECA-TE /2010. Phone: Fax: Web:

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

PowerFlex 400 Submittal

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

Why choose Danfoss? VLT Technical data Dimensions Ordering

EN 50178, IEC

M-Max series drives. The next generation of OEM drives

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 5

Document code: DPD00343A Edited:

The new Yaskawa Varispeed G7 Inverter

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Frequency Inverters. VF-nC3 VF-S11 VF-FS1 VF-PS1 VF-AS1

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

FDU50 Frequency inverters 018 to 037 (S2) FDU50 Frequency inverters 046 to 060 (X2)

Product description. At a glance. Customer benefits

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1.0HP 350HP V Single & 3 Phase Input

Frequency inverters DF Vector frequency inverters DV

FUJI Inverter. Standard Specifications

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

Phoenix DX Clean Power (18 Pulse) AC Drive

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

VLT 8000 AQUA. Introduction

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Transcription:

vacon nxs robust drive for heavy use

the reliable choice The Vacon is a compact AC drive in the power range of 0.7 560 kw and supply voltages of 208 690 V for heavy use in machines, buildings and all branches of industry. The robust design incorporates effective protection against supply network disturbances. Trip-free operation is also guaranteed due to sophisticated motor control principles and motor/drive protection features, component selection and effective cooling. Enclosure classes of IP21 and IP5 and integrated high-level EMC filters make the Vacon suitable for all environments. The Start-Up Wizard and the standard All-In-One Application Package make parameter setting extremely easy in all cases, from simple to complex. The wide and flexible standard I/O and option for five I/O boards provide versatile controllability. The most common fieldbus options are also available. The modular design of the Vacon brings several advantages: the control terminals are safely separated from power terminals, upgrading the control inputs and outputs is easy and convenient, replacing the cooling fan (the only regularly replaceable component) is fast, the display panel can be utilized for parameter copying, etc. Features Easy to use display panel Interactive programming with Start-Up Wizard Versatile All-in-One Package PID controller and PFC for 1-5 pumps Special applications available (water application package, high speed, etc.) Five slots for control boards (2 basic boards and option boards) High switching frequency, low noise Steady state speed error < 1% Low torque ripple Starting torque > 200%, depending on AC drive sizing Suitable for multi-motor applications Snap-on fan Robust power module Removable display Connection to PC or door installation kit Touch-protected connections Separate control unit, flexible I/O interface vacon nxs ip21 fr fr5 fr6 fr7 fr8 fr9 2

design & dimensions The mechanical design is extremely compact. The IP5 units in particular are the smallest AC drives on the market. All units are suitable for both wall and enclosure mounting with all necessary components: integrated EMC filters, AC chokes, cable protection, dust and water protection. The effective super-cooling principle allows high ambient temperatures and high switching frequencies without derating. Mains voltage 80 500 V, 50/60 Hz, ~, Wall-mounted units Loadability Motor shaft power Low (+0 C) High (+50 C) 00 V supply AC drive type current I L (A) 10% current I H (A) Maximum 10% current I S overl. overl. Frame size Dimensions W*H*D (mm) 000 000 0005 0007 0009 0012 0016 00 001 008 005 0061 0072 0087 0105 010 0168 0205 0261 000 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSF 5 A 2 H 0 SSF.. 5.6 7.6 9 12 16 2 1 8 6 61 72 87 105 10 170 205 261 00.6.7 6.2 8. 9.9 1.2 17.6 25. 2 51 67 79 96 6 15 187 6 287 0 2.2.. 5.6 7.6 9 12 16 2 1 8 6 61 72 87 105 10 170 205 25. 5.0 6.5 8.. 1.5 18.0 2.0 5 7 57 69 92 108 11 158 210 255 08 68. 6.2 8.6 10.8 1 18 2 2 6 62 76 92 1 1 17 210 280 6 9 1.1 1.5 2.2 15 18.5 0 7 5 55 90 0 12 160 0. 1.1 1.5 2.2 15 18.5 0 7 5 55 90 0 12 FR5 FR5 FR5 1*91*21 1*91*21 1*91*21 27*591*257 27*591*257 27*591*257 80*50*62 80*50*62 Mains voltage 80 500 V, 50/60 Hz,, Standalone units Loadability Motor shaft power AC drive type current I L (A) Low (+0 C) High (+0 C) 00 V supply 10% current I H (A) Maximum 10% current I S Frame size Dimensions W*H*D (mm) 085 5 A 2 L 0 SSA 85 2 00 50 50 200 160 FR10 595*2020*602 060 5 A 2 L 0 SSA 60 506 85 578 69 250 200 FR10 595*2020*602 0520 5 A 2 L 0 SSA 520 572 60 690 828 250 250 FR10 595*2020*602 0590 5 A 2 L 0 SSA 590 69 520 780 96 15 250 FR 79*2020*602 0650 5 A 2 L 0 SSA 650 715 590 885 1062 55 15 FR 79*2020*602 070 5 A 2 L 0 SSA 70 80 650 9 70 00 55 FR 79*2020*602 vacon nxs ip5 fr fr5 fr6 fr7 fr8 fr9

product range Mains voltage 525 690 V, 50/60 Hz, ~, Wall-mounted units Loadability Motor shaft power Low (+0 C) High (+50 C) 690 V supply AC drive type current I L (A) 10% current I H (A) Maximum 10% current I S overl. overl. Frame size Dimensions W*H*D (mm) 000 0005 0007 0010 001 0018 00 0027 00 6 A 2 L 0SSS.5 10 1.5 18 27 5.0 6.1 8..0 1.9 19.8 2.2 29.7 7.2.5 10 1.5 18 27.8 6.8 8.. 15.0 20. 27.0.0 1 6. 9.0.0 15.0 20.0 27 6 5 15 18.5 0 2.2 15 18.5 001 0052 1 52 5 57 1 51 62 68 82 5 0 27*591*257 27*591*257 0062 0080 0100 62 80 100 68 88 0 52 62 80 78 9 120 10 12 160 55 90 5 55 0125 01 0170 0208 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 125 1 170 208 18 158 187 9 100 125 1 170 150 188 216 255 200 21 25 289 0 12 160 200 90 0 12 160 80*50*62 80*50*62 80*50*62 80*50*62 For all Vacon drives, ability is defined as follows: High: 1.5 x I H (1 min/10 min) @ 50 C; Low: 1.1 x I L (1 min/10 min) @ 0 C; I S for 2 sec every 20 sec. Mains voltage 525 690 V, 50/60 Hz, ~, Standalone units Loadability Motor shaft power AC drive type current I L (A) Low (+0 C) High (+0 C) 690 V supply 10% current I H (A) Maximum 10% current I S Frame size Dimensions W*H*D (mm) 0261 6 A 2 L 0 SSA 261 287 208 12 250 200 FR10 595*2020*602 025 6 A 2 L 0 SSA 25 58 261 92 70 15 250 FR10 595*2020*602 085 6 A 2 L 0 SSA 85 2 25 88 585 55 15 FR10 595*2020*602 016 6 A 2 L 0 SSA* 16 58 25 88 585 00 15 FR10 595*2020*602 060 6 A 2 L 0 SSA 60 506 85 578 69 50 55 FR 79*2020*602 0502 6 A 2 L 0 SSA 502 552 60 690 828 500 50 FR 79*2020*602 0590 6 A 2 L 0 SSA* 590 69 502 90 560 500 FR 79*2020*602 * max. ambient temperature of +5 C Hardware configurations, Standalone units FUNCTION IP21 IP5 (FR10 only) Integrated fuses Integrated load switch EMC filtering L EMC filtering T Integrated brake chopper (cabling top entry) AVAILABILITY Standard Optional (H: +20mm) Standard Optional Standard Optional Optional (H: +1 mm) fr10 fr

product range Mains voltage 208 20 V, 50/60 Hz, ~, Wall-mounted units Loadability Motor shaft power Low (+0 C) High (+50 C) 20 V supply AC drive type current I L (A) 10% current I H (A) Maximum 10% current I S overl. overl. Frame size Dimensions W*H*D (mm) 000 0007 0008 00 0012.8 6.6 7.8 12.5 5. 7. 8.6 12.1 1.8.7.8 6.6 7.8 5.6 7.2 9.9.7 16.5 7. 9.6 1.2 15.6 0. 1.1 1.5 2.2 0.55 0. 1.1 1.5 2.2 0017 0025 001 1 25 1 19. 2.1 12.5 1 25 18.8 26. 25 5 50 FR5 FR5 FR5 1*91*21 1*91*21 1*91*21 008 0061 8 61 52.8 67.1 1 8 6.5 72.0 62 96 15 00 0088 0 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 88 8 97 125 61 88 92 12 1 150 176 18.5 0 15 18.5 27*591*257 27*591*257 27*591*257 010 0170 0205 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 10 170 205 15 187 6 105 10 170 158 210 255 210 280 6 7 5 55 0 7 5 0261 000 2 A 2 H 0 SSF 2 A 2 H 0 SSF 261 00 287 0 205 25 08 68 9 90 55 80*50*62 80*50*62 vacon nxs type designation code 0007 A1A20000C Factory installed I/O boards and expanders (slots A, B, C, D and E) C = Profibus board OPT-C (slot E) 00 = no board (slot D) 00 = no board (slot C) A1 = basic I/O boards OPT-A1 (slot A) A2 = basic output relay board OPT-A2 (slot B) A = basic output relay board OPT-A (slot B) including thermistor input Hardware modifications (power unit, special modifications, board varnishing) Brake chopper option: 0 = no brake chopper 1 = internal brake chopper 2 = internal brake chopper and resistor Emission level: H = fulfils the standard EN 61800- (200), category C2 T = fulfils the standard EN 61800- (200), category C. Low earth current solution for IT networks L = fulfils the standard EN 61800- (200), category C C = fulfils the standard EN 61800- (200), category C1 Enclosure classification: 2 = IP21 5 = IP5 Control keypad: A = standard alpha-numeric keypad B = no keypad G = graphic keypad (Chinese and Russian letters) Nominal mains voltage: 2 = 208 20 V AC (-phase) 5 = 80 500 V AC (-phase) 6 = 525...690 V AC (-phase) Nominal current Maximum current of the unit @ 0 C e.g. 0007 = 7 Amps Product range: 5

vacon nxs control unit There are no fixed inputs or outputs in the Vacon. There are five slots (A, B, C, D and E) for I/O boards, and a suitable board can be selected for each slot (see the table below). The units are delivered with OPT-A1 and OPT-A2 boards if the I/O is not specified. In many countries, boards OPT-A1 and OPT-A are used as standard I/O as the galvanically isolated thermistor input is often required. Removable terminals, snap-in card installation, automatic card identification and instructions on the drive help making quick connections. If necessary, the inputs, outputs and fieldbus boards can be added in the field. The Vacon is simply the most flexible frequency converter series on the market. An external +2 V supply option enables communication with the control unit even if the mains supply is switched off (e.g. fieldbus communication and parameter settings). vacon option boards Card typecode Card slot I / O signal A B C D E D I D O D I DO AI ma ±V AI ma isol. AO ma V AO ma isol. RO NO NC RO N O +10V r e f Therm +2 EXT +2V Pt100 2-20 VAC input NOTE Basic I/O cards (OPT-A) OPT-A1 6 1 2 1 1 2 OPT-A2 2 OPT-A 1 1 1 OPT-A8 6 1 2 1 1 2 1) OPT-A9 6 1 2 1 1 2 2,5 mm 2 terminals I/O expander cards (OPT-B) OPT-B1 6 1 Selectable DI/DO OPT-B2 1 1 1 OPT-B 1 2 1 2) OPT-B5 OPT-B8 1 OPT-B9 1 5 Fieldbus cards (OPT-C) OPT-C2 RS-85 (Multiprotocol) Modbus, N2 OPT-C OPT-C OPT-C5 OPT-C6 OPT-C7 Profibus DP LonWorks Profibus DP (D9 type connector) CANopen (slave) DeviceNet OPT-C8 RS-85 (Multiprotocol, D9 type connector) Modbus, N2 OPT-CI OPT-CJ Modbus/TCP BACNet NOTES: Allowed slots for the board are marked in blue. 6 1) analogue signals galvanically isolated as a group, 2) analogue signals galvanically isolated separately.

vacon nxs standard i/o OPT-A1 Terminal Defaults settings Programmable 1 +10V Reference voltage +2 V GND OPT-A2 Terminal Defaults settings Programmable 21 R01 1...10 kω 2 AI1+ Frequency reference 0 10 V -10 +10 V, 0/ 20 ma AI1- AI common (GND) Differential AI2+ Frequency reference 20 ma 0 20mA, 0/-10 V 10 V R01 RUN Many possibilities 2 R01 2 R02 5 AI2- AI common (differential) GND 6 +2V Control supply (bidirectional) 7 GND I/O Ground 8 DIN1 Start forward Many possibilities 9 DIN2 Start reverse Many possibilities 10 DIN External fault input Many possibilities CMA Common for DIN1 - DIN (GND) Floating 12 +2V Control supply (bidirectional) 1 GND I/O Ground 1 DIN Multi-step speed select 1 Many possibilities 15 DIN5 Multi-step speed select 2 Many possibilities 16 DIN6 Fault reset Many possibilities 17 CMB Common for DIN - DIN6 (GND) Floating 20 VAC N +2 V GND 20 VAC 25 R02 FAULT Many possibilities 26 R02 OPT-A (alternative) Terminal Defaults settings Programmable 21 R01 R01 RUN Many possibilities 2 R01 25 R02 FAULT Many possibilities ma 18 AO1+ Output frequency (0 20 ma) Many possibilities 19 AO1- AO common (GND) 20 ma, 0 10 V 20 DO1 READY, I < 50 ma, U < 8 VDC Many possibilities N PTC 26 R02 28 TI1+ Thermistor 29 TI1- input fault Warning, fault, no response Default settings of OPT-A1, OPT-A2 and OPT-A for the Basic and Standard Applications. other typical options OPTION ORDER TYPECODE AVAILABILITY NOTE IP5 enclosure Factory option All Replace 2 by 5 in the type code, e.g. 02605A5H0 (SSS...) IP5-FR_, FR5, IP5 kit, e.g. IP5- Through-hole mounting Factory option - E.g. 02605ATH0STS..., IP5 back, IP21 front, kits available Integrated brake choppers Standard -6/20, 500 V E.g. 0055A2H1 (SSS...) Factory option -, -/690 V E.g. 02605A2H1 (SSS...) External brake resistors BRR-00-LD-5 0005-005 LD = Light duty: 5 sec nominal torque braking from (80-500 V range) BRR-001-LD-5 0015 nominal speed decreasing linearily to zero, once per 120 sec. HD = Heavy duty: sec nominal torque braking at BRR-005-LD-5 0085-0055 nominal speed + 7 sec nominal torque braking from nominal BRR-0061-LD-5 00615 speed decreasing linearily to zero, once per 120 sec. BRR-0105-LD-5 00725-01055 Replace LD by HD in the type code, e.g. BRR-0105-HD-5 Brake resistors are also available for 208-20 V and 525-690 V drives BRR-000-LD-5 0105-0005 The brake resistor manual is available for more precise selection Integrated brake resistors Factory option -6/500 V Replace 1 by 2 in the typecode, e.g. 0055A2H2 (SSS...) Light duty: 2 sec nominal torque braking from nominal speed decreasing linearily to zero, once per 60 sec. Graphical display panel Factory option All Replace A by G, e.g. 0055G2H1 (SSS..), supports Chinese & Russian PAN-G All Order typecode when ordered separately Panel door installation sets DRA-02B (-0B, -15B) All Length of RS22C cable is specified in the typecode, e.g. DRA-02B includes 2-meter RS22C cable Varnished circuit boards Factory option All Frame sizes -: replace the S by V, e.g. 0055A2H1SSV..., frame size -FR: replace S by G C-level RFI filters Factory option -6/500 V Replace H by C in the typecode, e.g. 0055A5C1 (SSS..) Du/dt & sinus filters Available for all drives, contact local Vacon supplier 7

first-class usability The uncluttered text display panel with a well-defined menu structure and functions such as automatic parameter copy and start-up wizard makes commissioning and fine-tuning as easy as possible. The Vacon PC tools are available for downloading from the Vacon website. These include: Vacon NCDrive for parameter setting, copying, storing, printing, monitoring and controlling Vacon NCLoad for software updating and uploading special software to the drive Vacon NC61- Engineering is available for making tailor-made software. A license key and training required. A maximum of three values can be monitored simultaneously (the multi-monitoring feature). The Vacon PC tools require only an RS22C cable for communication with the drive (no adapters etc. required). Basic I/O Defaults AI1 fref P AI2 fref P DI1 Start forward DI2 Start reverse DI External fault P DI Speed select 1 DI5 Speed select 2 DI6 Fault reset DO1 Ready RO1 Run RO2 Fault Suitable for most purposes Standard I/O Defaults AI1 fref P AI2 fref P DI1 Start forward P DI2 Start reverse P DI External fault P DI Speed select 1 DI5 Speed select 2 DI6 Fault reset DO1 Ready P RO1 Run P RO2 Fault P Basic, with more programming possibilities Local/Remote I/O Defaults AI1 B fref P AI2 A fref P DI1 A Start forward P DI2 A Start reverse P DI External fault P DI B Start forward P DI5 B Start reverse P DI6 A/B selection DO1 Ready P RO1 Run P RO2 Fault P Two external control places 8

software modularity All-in-one Application package (standard) Water Solutions application package (option) Special Applications (several options) Local / Remote Multi-step Speed Multimaster PFC Standard PID Control Advanced Level Control Standard Lift Basic Pump and Fan Control Multipurpose MultiFollower PFC Fire mode PID High speed 1900Hz The All-in-One application package has seven applications (=default settings and functionality of control inputs and outputs, see tables below) which can be selected with one parameter. The application will also be requested by the Start-up Wizard at the first power-up. With this single setting, the controls can be programmed e.g. for two external control places or a pressure control with the integrated PID controller. In most cases, the default basic application is suitable and only the min/max frequencies as well as motor nominal values must be set. Thanks to the modular software applications made by the Vacon NC61- Engineering tool, the All-in-One application package can be replaced by the Water application package that contains several applications optimized for water handling. There are als o several other general-purpose software applications available. P = Programmable Multi-step Speed Control PID Control Multi-purpose Control Pump and Fan Control I/O Defaults I/O Defaults I/O Defaults I/O Defaults AI1 fref P AI1 PID reference P AI1 fref P AI1 PID reference P AI2 fref P AI2 PID actual value P AI2 fref P AI2 PID actual value P DI1 Start forward P DI1 PID start/stop DI1 Start forward P DI1 PID start/stop P DI2 Start reverse P DI2 External fault P DI2 Start reverse P DI2 Interlock 1 P DI External fault P DI Fault reset P DI Fault reset P DI Interlock 2 P DI Speed select 1 DI f ctrl start/stop DI Jog speed sel P DI f ctrl start/stop P DI5 Speed select 2 DI5 Jog speed select P DI5 External fault P DI5 Jog speed select P DI6 Speed select DI6 PID/f ctrl select DI6 Acc/dec time sel P DI6 PID/f ctrl select P DO1 Ready P DO1 Ready P DO1 Ready P DO1 Fault P RO1 Run P RO1 Run P RO1 Run P RO1 Autochange 1 P RO2 Fault P RO2 Fault P RO2 Fault P RO2 Autochange 2 P 16 fixed speeds When PID is required Most flexible of all Control of up to five pumps with auto-change 9

emc and installation environment 1ST ENVIRONMENT 2 1 2 5 2ND ENVIRONMENT The product family standard EN61800- sets limits for both emissions and immunity of radio frequency disturbances. The environment has been divided into the 1st and 2nd environments, i.e. in practice, the public and industrial networks, respectively. Radio Frequency Interference (RFI) filters are typically required to meet the EN61800- standard. These filters are integrated in the Vacon as standard. The 208 20 V and 80 500 V ranges of the Vacon (- ) fulfills the requirements of the 1st and 2nd environments (H level: EN61800-(200), category C2). No additional RFI filters or cabinets are required. The FR10-FR and the 525-690 V range of the Vacon fulfills the requirements of the 2nd environment (L-level: EN61800-(200), category C). The units in the frame sizes of, FR5 and (the voltage range from 80 to 500 V) are also available with extremely low-emission integrated EMC filters (C level: EN61800- (200), category C1). This is sometimes required in very sensitive locations such as hospitals. EMC Selection Table, restricted distribution 1 2 5 Vacon EMC Hospital Residential Area Commercial Light Industry Area Heavy Industry Marine C O H R R R O O L R R T R (IT Network) R (IT Network) R = Required ; O = Optional 10

technical data Mains connection Motor connection Input voltage U in 208 20 V; 80 500 V; 525 690 V; ( 15% +10%) Input frequency 50 60 Hz (± 10%) Connection to mains Once per minute or less (normal case) Output voltage 0 U in Continuous output current High ability: I H Control characteristics Overloadability Max. starting current Output frequency Frequency resolution Control method Switching frequency Field weakening point Acceleration time Deceleration time Braking Low ability: I L High: 1.5 x I H (1 min/10 min), Low: 1.1 x I L (1 min/10 min) I s for 2 s every 20 s 0 20 Hz; up to 7200 Hz with special software 0.01 Hz Frequency control U/f; Open Loop Vector Control (speed, torque) 208..20V/80..500V: -6: 1 16 khz; Factory default: 10 khz -9: 1 10 khz; Factory default:.6 khz FR10-: 1 6 khz; Factory default:.6 khz 525..690V: -: 1 6 khz, Factory default: 1.5 khz 8 20 Hz 0 000 sec 0 000 sec DC brake: 0% * T N (without brake resistor), flux braking Ambient conditions Ambient operating temperature 10 C (no frost) +50 C: I H (FR10-FR: max +0 C) 10 C (no frost) +0 C: I L ( 016 6 and 0590 6: max +5 C) Storage temperature Relative humidity Air quality: - chemical vapours - mechanical particles Altitude Vibration EN50178/EN60068-2-6 Shock EN50178, EN60068-2-27 Enclosure class 0 C +70 C 0 to 95% RH, non-condensing, non-corrosive, no dripping water IEC 60721--, unit in operation, class C2 IEC 60721--, unit in operation, class S2 100% load capacity (no derating) up to 1000 m 1-% derating for each 100 m above 1000 m; max. 000 m 5...150 Hz: Displacement amplitude 1 mm (peak) at 5 15.8 Hz (FR10-FR: 0,25 mm (peak) at 5 1 Hz) Max acceleration amplitude 1 G at 15.8 150 Hz (FR10 and up: 1 G at 1 150 Hz) UPS Drop Test (for applicable UPS weights) Storage and shipping: max 15 G, ms (in package) IP21 and IP5 EMC Immunity Fulfil all EMC immunity requirements Safety Control connections (OPT-A1, -A2 or OPT-A1, -A) Protections Emissions EMC level C: EN61800- (200), category C1 EMC level H: EN61800- (200), category C2 EMC level L: EN61800- (200), category C EMC level T: Low earth-current solution suitable for IT networks, EN61800- (200), category C EN 50178 (1997), EN 6020-1 (2006), IEC 61800-5, CE, UL, CUL; (see unit nameplate for more detailed approvals) Analogue input voltage 0 +10 V ( 10 V +10 V joystick control), R i = 200 kω, resolution 0.1%, accuracy ±1% Analogue input current 0() 20 ma, R i = 250 Ω differential, resolution 0.1%, accuracy ±1% Digital inputs 6, positive or negative logic; 18 0 VDC Auxiliary voltage +2 V, ±15%, max. 250 ma Output reference voltage +10 V, +%, max. load 10 ma Analogue output 0() 20 ma; R L max. 500 Ω, resolution 10 bit, accuracy ±2% Digital output Open collector output, 50 ma/8 V Relay outputs 2 programmable change-over (NO/NC) relay outputs (OPT-A: NO/NC+NO) Switching capacity: 2 VDC/8 A, 250 VAC/8 A, 125 VDC/0. A. Min. switching load: 5 V/10 ma Thermistor input (OPT-A) Galvanically isolated, R trip =.7 kω Overvoltage, undervoltage, earth fault, mains supervision, motor phase supervision, overcurrent, unit overtemperature, motor, motor stall, motor underload, short-circuit of +2 V and +10 V reference voltages