Global Water Instrumentation, Inc.

Similar documents
Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc.

RHS SERIES RH Set Point Controller/Probe

HydroLynx Systems, Inc.

TRANSDUCER IN-LINE AMPLIFIER

METEOROLOGICAL INSTRUMENTS

CS105 BAROMETRIC PRESSURE SENSOR

AMP-13 OPERATOR S MANUAL

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

NOVALYNX CORPORATION MODEL 110-WS-16TH TEMPERATURE AND RELATIVE HUMIDITY SENSOR INSTRUCTION MANUAL

Programmable K-Factor Scaler B and Programming Software Kit B

Owner s Manual & Safety Instructions

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Glass Electrode Meter

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Planishing hammer stand For use with SKU Planishing hammer

Ambient Weather WS-0270 Wireless Indoor / Outdoor Thermometer with Indoor Humidity User Manual

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

HHMA2 DC / TRUE RMS AC NON-CONTACT MILLIAMMETER

C5000 & C5000NF PULSE INITIATOR. Introduction

1523, 1524 Thermometer Readout User s Guide

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

TDS-535 Tuned Dipole Set Operation Manual

LM600 Landmark Permanent Blind

LD8000 Series LD8025 LD8050 LD8100

Shrinker and stretcher

METEOROLOGICAL INSTRUMENTS

Owner s Manual & Safety Instructions

K-FACTOR SCALER B & B

SAS-543 Biconical Antenna Operation Manual

SSR-150xxx-40VL-12P-xC-xxxCS

Broadband Current Probe Series Operation Manual

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

Model: SS660-PT-R Stainless Steel Poly-Top Floor Scale Series. Installation, Set-Up and Operation Manual

SAS-563B Active Loop Antenna Operation Manual

SAS-562B Active Loop Antenna Operation Manual

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Model: SS660-OB Stainless Steel Floor Scale Series. Installation, Set-Up and Operation Manual

The component shall reproduce the original musical sound, purely and naturally.

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Broadband Current Probe Series Operation Manual

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

OWNER'S MANUAL TIE ROD, WALL & FLOOR MOUNTED JIBS. Model JIB-HC, JIB-LC, JIB-FM

TRANSDUCER IN-LINE AMPLIFIER

SRS-200 Solar Radiation Sensor Installation and Setup Instructions. SRS-200 with optional Leveling Plate and Mounting Bracket. Revision 2.0.

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

PixController, Inc. Wireless Vibration Sensor For Indoor and Outdoor Use

AMP-12 OPERATOR S MANUAL

14 Piece Slide Hammer and Puller Set

4. CONNECTIONS. Make sure all connections to and in your Universal Rectifier are tight.

Advanced Test Equipment Rentals ATEC (2832)

Instruction Manual. HB Series Mini Level Sensor

USER S MANUAL PROCESS CONTROL MODULE PCM3

PORTROD WALL MOUNTED HEIGHT ROD

ANTENNA SYSTEMS. PTX Offset Antenna.60/.76/.90./1.1m INSTALLATION & ASSEMBLY INSTRUCTIONS

INSTRUCTION MANUAL INF Fax: (503)

200Amp AC Clamp Meter + NCV Model MA250

742A Series Resistance Standards

instructions for Models QC-10 and QC-20 Sound Calibrators MODELS QC-10/QC-20 SOUND CALIBRATORS GENERAL DESCRIPTION

MODEL 3810/2 Line Impedance Stabilization Network

M E E T I N S T R U M E N T A T I E MAS ma Soil Moisture Sensor. User Manual. Version 4

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

LT3000 ULTRASONIC LEVEL TRANSMITTER

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

LJ element beam for 10 or 12 meters INSTRUCTION MANUAL. CAUTION: Read All Instructions Before Operating Equipment

HT2 Humidity Transmitter HT2 Humidity and Temperature Transmitter Installation and Operating Instructions

Instruction Manual Model Upconverter

Models 2230 and 2240

Soil Moisture Smart Sensors (S-SMx-M005)

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

MODEL M1023 QUICK CHANGE COLLET ATTACHMENT INSTRUCTION MANUAL. Phone: On-Line Technical Support:

MANUAL METAL SHRINKER/STRETCHER

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

METEOROLOGICAL INSTRUMENTS

Temp / RH / CO 2 Hand-Held Meter

Angular Rate Sensor. Owner's Manual

FXL-168 FIXED RACK ASSEMBLY INSTRUCTIONS SALES ORDER #

PHASE ROTATION METER. Operating and Instruction Manual. a n d A C C E S S O R I E S

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

9 QUICK RELEASE WOODWORKING VISE

PRODUCT SAFETY SOLUTIONS MODEL HWI-01. Model HWI-01 Serial Number:

Fit IPL-R. Instruction Manual (Rev06 - Jun 2018; Firm. Vers.11)

Handheld Infrared Thermometers

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Operator s Manual. PP022 Passive Probe

GT Series Grooving Tool

TSSP-1 (Stainless Steel Thermistor Probe) Manual Rev A

Owner s Manual ODYSSEY BENCH MODEL. O4100B shown REV E. Southern Avenue, Phoenix, AZ USA Workhorseproducts.

Copyright 2014 by Minarik Drives

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

INSTRUCTION MANUAL. Specifications Electrical. Front-To-Back Ratio VSWR at Resonance Less than 1.5:1 Nominal Impedance. Mechanical

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

SAS-551 Passive Monopole Antenna Operation Manual

Transcription:

Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Barometric Pressure: WE100 Solar Radiation: WE300 Wind Speed: WE550 Wind Direction: WE570 Humidity: WE600 Air Temperature Sensor: WE700 Surface Temperature Sensor: WE710 Solar Shield: WE770 00-671 Rev. 11/30/09-1 -

Congratulations on your purchase of the Global Water Weather Sensor. This instrument has been quality tested and approved for providing accurate and reliable measurements. We are confident that you will find the sensor to be a valuable asset for your application. Should you require assistance, our technical staff will be happy to help. Table of Contents I. Checklist Page 3 II. Inspection 3 III. General Sensor Installation 4 IV. Barometric Pressure Sensor 5 V. Solar Radiation Sensor 7 VI. Wind Speed Sensor 8 VII. Wind Direction Sensor 9 VIII. Humidity Sensor 10 IX. Temperature Sensor 11 X. Solar Shield 12 XI. Maintenance 12 XII. Troubleshooting 13 XIII. Warranty 14 XIV. Appendix A: Temperature Calibration Check 15 XV. Appendix B: 2 Wire Sensor Measurement Diagram 16 XVI. Appendix C: 3 Wire Sensor Measurement Diagram 17 XVII. CE Certification 18 * Copyright Global Water Instrumentation, Inc. 2002-2 -

I. Sensor Checklist a. Weather Sensor b. Weather Sensor Manual II. Inspection a. Your Weather sensor was carefully inspected and certified by our Quality Assurance Team before shipping. If any damage has occurred during shipping, please notify Global Water Instrumentation, Inc. and file a claim with the carrier involved. Use the checklist to ensure that you have received everything needed to operate the weather instrument(s). - 3 -

III. General Sensor Installation a. Weather sensors have many applications and therefore many installation options. The sensors should be located in a clear area on a level surface. b. Install your Weather sensor so that it is easily accessible for calibration purposes. You may need to remove and reinstall it in the future, so plan ahead! c. All Global Water Weather sensors produce a 4-20 ma output signal. 4-20 ma is an industrial standard signal for process control monitoring. Most PLCs (Programmable Logic Controller), RTUs (Remote Telemetry Unit), and data acquisition systems accept this signal directly. If the system only accepts voltage signals, the sensor output must be converted to a voltage signal by reading the voltage across a precision resistor in series with the signal wire. Since Ohms Law states that V = IR, if the 4-20 ma signal is dropped across a 250 ohm resistor, the output will be 1 to 5 volts DC. If the 4-20 ma signal is dropped across a 125 ohm resistor, the output will be halved to 0.5 to 2.5 VDC. The 4-20 signal wire is connected to the datalogger voltage input terminal. The resistor is placed between this input and the ground terminal of the datalogger s battery. The power (or voltage to the sensor) must be connected to positive battery terminal of the datalogger. d. The sensors may be pulsed on or turned on by the logging system prior to taking a reading. Use a warm up time appropriate to the Weather sensor you are using to assure that the sensor is fully on. The sensors can run continuously for real time applications. Each sensor draws between 4 and 20 ma depending on whether the sensor is reading at the minimum or maximum of its range. - 4 -

IV. e. Weather sensors may be stored without any special provisions. Place the sensor inside a bag to keep the sensor clean and store on a shelf or hang it on a wall. Barometric Pressure Sensor a. Barometric Pressure sensor specifications. Output: Range: Accuracy: Operating Voltage: Current Draw: Warm Up Time: Operating Temperature: Size of Probe: Weight: 4-19mA 800-1100 millibars +1% of full scale 10-36VDC Same as sensor output 3 seconds minimum -40 to +55 C 3 x2 x1.13 lb. b. The sensor is a two-wire sensor using the red wire for power and the black wire for the output signal. Warning: Always connect the sensor with the power turned off. c. The barometric pressure sensor may be stored without any special provisions. Place the sensor inside a bag to keep the sensor clean and store on a shelf or hang it on a wall. d. When you read a barometer the reading directly from it is the "station pressure." Two things affect the barometer's reading, the high or low air pressure caused by weather systems, and the air pressure caused by the station's elevation, or how high it is above sea level. No matter what weather systems are doing, the air's pressure decreases with height. If you're trying to draw a weather map of air pressure patterns, you need a way to remove the effects of the station's elevation. That is, you want to see what the pressure would be at the station if it were at sea level. - 5 -

You need to calculate, sea-level pressure, which is defined as: "A pressure value obtained by the theoretical reduction of barometric pressure to sea level. Where the Earth's surface is above sea level, it is assumed that the atmosphere extends to sea level below the station and that the properties of that hypothetical atmosphere are related to conditions observed at the station." To do this, you have to take into account the barometric reading at the station, the elevation above sea level, and the temperature. - 6 -

V. Solar Radiation Sensor a. Solar Radiation sensor specifications. Output: 4-20mA Range: 0-1500 Wm 2 Accuracy: 1% of full scale Operating Voltage: 10-36VDC Current Draw: Same as sensor output Warm Up Time: 3 seconds minimum Operating Temperature: -40 C to +55 C Size of Probe: 3" diameter x 1 1/2" high Weight: 1/4 lb. b. The sensor is a two-wire sensor using the red wire for power and the black wire for the output signal. Warning: Always connect the sensor with the power turned off. c. Ensure that the sensor is placed on a level surface, use the alignment bolts to adjust the sensor until it is level. Remove the red cap to begin taking readings. d. The solar radiation sensor or pyranometer is an instrument for measuring solar radiation received from a whole hemisphere. It is suitable for measuring global sun plus sky radiation. Solar radiation varies significantly among regions. Season and time of day are major considerations, but surrounding terrain elevation, man-made obstructions, and surrounding trees can also cause large variations in locations with a small area. Often, the required measurement is, energy flux density of both direct beam and diffuse sky radiation passing through a horizontal plane of known unit area (i.e., global sun plus sky radiation). e. Calibration should be confirmed annually. - 7 -

VI. Wind Speed Sensor a. Wind Speed sensor specifications. Output: Range: Accuracy: Operating Voltage: Current Draw: Warm Up Time: Operating Temp: Size of Probe: Weight: 4-20mA 0-110 MPH.2 MPH over the range 11 to 55 MPH 10-36VDC Same as sensor output 3 seconds minimum -40 to +55 C 7 diameter x 8 ½ long 1 lb. b. The sensor is a two-wire sensor using the red wire for power and the black wire for the output signal. Warning: Always connect the sensor with the power turned off. c. The sensor comes with a stainless steel elbow that can be mounted on a 1 diameter tube. For best results ensure that the sensor is mounted parallel to the ground surface. d. The wind speed sensor or anemometer produces a sine wave voltage signal with a frequency that changes linearly with the wind speed. The frequency is transformed into a 4-20 ma sensor signal output. - 8 -

VII. Wind Direction Sensor a. Wind Direction sensor specifications. Output: Range: Accuracy: Operating Voltage: Current Draw: Warm Up Time: Operating Temp: Size: Weight: 4-19 ma 0 to 360 (352 electrical, 8 open) 1% of full scale 10-36VDC Same as sensor output 3 seconds minimum -40 to +55 C 8 ½ diameter x 10 ½ long 1 lb. b. The sensor is a two-wire sensor using the red wire for power and the black wire for the output signal. Warning: Always connect the sensor with the power turned off. c. The ridge on the fixed portion of the sensor represents the 0 direction of the sensor. The sensor comes with a stainless steel elbow that can be mounted on a 1 diameter tube. For best results ensure that the sensor is mounted parallel to the ground surface. d. A wind direction sensor produces a ratiometric voltage signal. That voltage signal is transformed into a 4-19 ma sensor output signal. - 9 -

VIII. Humidity Sensor a. Humidity sensor specifications. Output: Range: Accuracy: Operating Voltage: Current Draw: Warm Up Time: Operating Temp: Size of Probe: Weight: 4-19mA 0-100% RH + 2% RH 10-36VDC 3 ma plus sensor 3 seconds minimum -40 to +55 C 1 ½ diameter x 7 long ½ lb. b. The humidity sensor is a three-wire sensor. Three wire sensors use the red wire for positive voltage, the white wire for the output signal, and the black wire for ground. Warning: Always connect the sensor with the power turned off. c. Do not install the humidity sensor in direct sunlight. d. A humidity sensor utilizes a thin polymer that varies in dielectric constant directly proportional to changes in the amount of water vapor at the sensor element. The element provides a linear voltage output that is converted into a 4-19 ma sensor output signal. - 10 -

IX. WE700 and WE710 Temperature Sensors a. Temperature sensor specifications. Output: WE700 Range: WE710 Range: WE700 Accuracy: WE710 Accuracy: Operating Voltage: Current Draw: Warm Up Time: Storage Temperature: Size of Probe: Weight: 4-19mA -50 C to + 50 C (-58F to +122F) -50 C to + 85 C (-58F to +185F) ±0.2 F or ±0.1 C ±0.5 F or ±0.27 C 10-36VDC Same as sensor output 3 seconds recommended -50 C to +100 C ¾" diameter x 4 ½" long ½ lb. b. The sensor is a two-wire sensor using the red wire for power and the black wire for the output signal. Warning: Always connect the sensor with the power turned off. Do not install the temperature sensor in direct sunlight. c. To check the temperature sensor calibration you will need: 1 thermometer 1 insulated container of at least on gallon 1 power supply 1 current meter Connecting wires as necessary Connect the sensor to the power supply and current meter in the following way. Attach the black wire to the positive input of the current meter. Connect the ground terminal of the power supply to the ground of the current meter. Attach the red wire to the positive terminal of the power supply. Warning: Always connect the sensor with the power turned off. See Appendix A for the temperature calibration worksheet. - 11 -

X. Solar Shield a. Solar Shield specifications. Global Water Size: Weight: 4 diameter x 8 ½ long 1 lb. b. The solar shield is used to protect sensors, typically humidity and temperature, from direct sunlight. Insert a sensor into one of the two holes located on the underside of the shield. The shield provides a friction lock so the sensors will not accidentally fall out. The sensors can be removed by firmly twisting and pulling them out of the solar shield. c. The shield comes with a stainless steel elbow that can be mounted on a 1 diameter tube. For best results ensure that the shield is mounted vertically. XI. Maintenance a. Global Water recommends confirming the calibration annually. b. The sensors should be cleaned periodically. Sensors can be cleaned using a damp cotton cloth. NOTE: DO NOT submerge sensors. The sensors are water resistant, not water proof. - 12 -

XII. Trouble Shooting Global Water Issue: Sensor reading incorrectly a. Verify power source is supplying correct voltage. b. Clean the sensor. c. Confirm the sensor s calibration. Other issues d. Call Global Water for tech support: 800-876-1172 or 916-638-3429 (many problems can be solved over the phone). Fax: 916-638-3270 or Email: globalw@globalw.com. When calling for tech support, please have the following information ready; 1. Model #. 2. Unit serial number. 3. P.O.# the equipment was purchased on. 4. Our sales number or the invoice number. 5. Repair instructions and/or specific problems relating to the product. Be prepared to describe the problem you are experiencing including specific details of the application, installation, and any additional pertinent information. e. In the event that the equipment needs to be returned to the factory for any reason, please call to obtain an RMA# (Return Material Authorization). Do not return items without an RMA# displayed on the outside of the package. Clean and decontaminate the sensor if necessary. Include a written statement describing the problems. Send the package with shipping prepaid to our factory address. Insure your shipment, Global Water s warranty does not cover damage incurred during transit. - 13 -

XIII. Warranty a. Global Water Instrumentation, Inc. warrants that its products are free from defects in material and workmanship under normal use and service for a period of one year from date of shipment from factory. Global Water s obligations under this warranty are limited to, at Global Water s option: (I) replacing or (II) repairing; any products determined to be defective. In no case shall Global Water s liability exceed the products original purchase price. This warranty does not apply to any equipment that has been repaired or altered, except by Global Water Instrumentation, Inc., or which has been subject to misuse, negligence or accident. It is expressly agreed that this warranty will be in lieu of all warranties of fitness and in lieu of the warranty of merchantability. b. The warranty begins on the date of your invoice. - 14 -

XIV. Appendix A: Temperature Calibration check Step 1) Step 2) Step 3) Step 4) Step 5) Step 6) Fill a container of water with enough ice that it will not melt quickly. The water must be circulated frequently and during measurements. Insulated containers work best. Place the temperature sensor and thermometer into the bottom of the container. Turn on the power supply and the current meter. Let the sensor stabilize for 30 minutes before taking any measurements. Record the ice bath temperature, IT =, and record the output current of the sensor, IC =. Fill a container with enough warm water that it will not cool down quickly. Insulated containers work best. Place the temperature sensor and thermometer into the container. Turn on the power supply and the current meter. Let the sensor stabilize for 30 minutes before taking any measurements. Record the warm water temperature, WT =, and record the output current of the sensor, WC =. Step 7) Subtract IC from WC, WC- IC = = C. Step 8) Subtract IT from WT, WT- IT = = T. Step 9) Calculate B. WC (C/T)(WT)= = B. Step 10) Find the low current value for the sensor. (C/T)(50)+B= = LC. This current is the output current the sensor would produce if the temperature were -50 C. Step 11) Find the high current value for the sensor. (C/T)(50)+B= = HC. This current is the output current the sensor would produce if the temperature were 50 C. Step 12) Use these new current values to recalibrate the system that is monitoring the sensor output. - 15 -

XV. Appendix B: 2 Wire Sensor Measurement Diagram - 16 -

XVI. Appendix C: 3 Wire Sensor Measurement Diagram - 17 -

Declaration of CE Conformity Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 USA FAX: 00 1 916 638 3270 Phone: 00 1 916 638 3429 declares that the Products: Product Name: Weather Sensors, Air Temperature, Flat Surface Temperature, Humidity, Wind Speed, Wind Direction, Barometric Pressure, Solar Radiation Model Number: WE700, WE710, WE600, WE550, WE570, WE100, WE300 conforms to the following European Council directives: Low Voltage Directives: 2006/95/EC; Requirements covering all health and safety risks of electrical equipment operating within certain voltage ranges. According to the following standards: EN61010-1: 2001 Electro-Magnetic Directives: 2004/108/EC; Requirements to prevent electrical and electronic equipment from generating or being affected by electromagnetic disturbances. According to the following standard: EN 61326-1: 2006 Global Water hereby certifies that the product stated above conforms to all directives and standards required for it to bear the CE mark. Dale Daniel Engineering Manager Global Water Instrumentation, Inc. - 18 -