Digital Anemometer

Similar documents
Wind Direction Transmitter - compact

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter - compact - with serial output x0.x00

Wind Direction Transmitter - compact - GMR, analogue output xxx

Wind Transmitter First Class

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Wind Transmitter First Class / 141 / / 141 / 161

Wind Transmitter - with analogue output xxx

Wind Transmitter - compact

Wind Transmitter First Class Advanced Classified according to IEC ( )

Brightness Transmitter

Precipition Sensor with analogue Intensity Output ,

Wind Transmitter compact xx

Wind Transmitter - with frequency output xx.xxx

Hygro-ThermoTransmitter-compact xxx

Precipitation Monitor ,

Baro Transmitter PTB x1.073

Wind Direction Transmitter First Class analogue output x0.1xx

Sensor PAR xxx

Brightness Transmitter - direction-independent xxx

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx

Precipitation Transmitter xxx / xxx

Combined Wind Transmitter - with analogue output xxx

Wind Transmitter compact xx

Precipitation Transmitter / 008 / 009 / 010 / 011 / 107 / / 009

Instruction for Use /05/09. Wind Transmitter - compact x0.xxx x0.xx x0.xx0

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

Wind Direction Transmitter First Class analogue output x0.1xx

Operating Instructions CAMILLE BAUER METRAWATT METRAOHM /9.97. Low impedance resistance meas. instrument

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Measuring current transformers of the W, W series

Wind Direction Transmitter First Class Low Power Device with digital output, 8 Bit serial-synchronous x0.000

Measuring current transformers of the W AB(P) series

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B

Measuring current transformers of the W B series

PROFiTEST C Test Instrument per DIN VDE /8.14

Baro Transmitter xxx

WIND VANE THIES FIRST CLASS 2014 TMR

Ultrasonic Anemometer

RISH Max-12 and 14 Analog-Digital Multimeter. Data Sheet. RISH Max-12 and 14 Analog-Digital Multimeter. Rishabh Instruments

Instruction Manual. DIGIPRO F2 Exposure Meter for Flash and Ambient Light /11-12

Wind Direction Transmitter First Class - Device with digital output, RS Wind velocity signal acquisition x0.400

METRATESTER 5+ Tester for DIN VDE /6.15

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

Analogue Demo Multimeter ADM

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

MultiMeter-Pocket CAT III 1000 V

Fluke and

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing

OPERATING INSTRUCTIONS

WIND VANE THIES COMPACT

NEW TOUGHEST WIND SENSORS THE WORLD S 1:2

Explosion proof rotary actuator - On/Off or programmable regulating actuator

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Ultrasonic Anemometer 2D

WIND T H E W O R L D O F W E A T H E R D A T A

PROFiTEST C Test Instrument per DIN VDE /11.10

Quick Start Guide AT-6000 Advanced Wire Tracer Series

Analyzer Twin. k +49 (0) / (0) / General Agent Germany:

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry

MY NEW WA 80. FEATURES, OPTIONS.

pipeline integrity PCM + Pipeline Current Mapper

Manual Hand-held Gaussmeter BGM101

Electrical height adjustment. ... easy & reliable. Multilift II telescope Multilift II. Synchron

AS-LED COMBINED OBSTRUCTION LIGHTS

Multifunction AC/DC Voltage Tester

400 Va.c., 500 Va.c., 690 V a.c. Rated current I n. 120 ka

Temperature Input Module for Zone 1 Series 9482/32

PHOTOELECTRIC SENSORS. Online data sheet

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

LENORD. +BAUER... automates motion. GEL 2351 with current or voltage interface. Technical information Version General. Features.

LENORD. +BAUER... automates motion. GEL 295x Customer-specific precision encoder. Technical Information Version General information.

Digital Gauss/Tesla Meter

Overview of types. Technical data

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

Multi-function measuring instrument

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

XY-Stages series 5102

Data Sheet. Analog - Digital Multimeter. RISH Multi RISH Multi Analog-Digital Multimeter. Page 1 of 6. Rishabh Instruments

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

DE EN FR ECOLINE EL 609 BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI EXACTLY WHAT YOU NEED.

Inductive Analog-Sensors

2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Enhanced Sidelobe Suppression

THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry

Pipeline Current Mapper

Multi-function measuring instrument

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Inclination Transmitters Heavy Duty

Features. Rechargeable and waterproof. Controller

Fieldbus Isolating Repeater Series 9185/11

Operating Instructions

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

WIND VANE THIES COMPACT TMR

ZipLevel A / Rev 0508-GB. Operation manual

Temperature transmitter itemp PCP DIN rail TMT 121

Transcription:

THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021404/07/04 Digital Anemometer 4.3406.00.000 ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Box 3536 + 3541 37025 Göttingen Phone +49 551 79001-0 Fax +49 551 79001-65 www.thiesclima.com info@thiesclima.com

Contents 1 Model... 2 2 Application... 2 3 Display... 3 4 Operation... 3 5 Maintenance... 4 6 Technical Data... 5 7 Accessory (optional)... 6 1 Model The Digital Anemometer consists of a wind transmitter with firmly connected cable, a display instrument, and a transport case. The cable is connected to the display instrument by means of a plug. The wind transmitter is made of corrosion-free materials (aluminium, plastics). The display instrument is made of sturdy plastic. The button for function is installed in a way that an easy operation is possible. The compartment on the back side contains a 9V-dry battery for power supply. 2 Application The Digital Anemometer serves for the measurement of wind speeds, and is suited for mobile use. Remark: In order to achieve an exact measurement of the horizontal wind speed, please hold the wind transmitter in vertical position. Attention: Operation and storing under weather conditions is permissible only in vertical position, as otherwise water can get into the instrument. Please protect the display instrument from precipitation. 2-6 021404/07/04

3 Display The following measuring values are indicated on the 3-digits LCD-display: Wind speed as instantaneous value Wind speed as 10 seconds gliding mean values In addition, the following status reports are indicated on the LCD-display: Battery status LOBAT (acoustic signal in addition) Exceeding of measuring range: 199.9 Operating mode gliding mean value: + Gliding mean value in calculation: + blink 4 Operation Connect the wind transmitter to the display instrument by means of a cable. Hold the wind transmitter into the air flow. Switch the display instrument on by pressing the operation button. Switching-on : When pressing the button shortly the display starts in the mode instantaneous value, which is confirmed by a beep. Change-Over of Mode: Further (brief) activations of the button make the display change between instantaneous value and mean value. Each button pressing is confirmed by a short beep. Switching-off: The switching-off is carried out either automatically 60 seconds after the wind transmitter has stopped, or by pressing the button longer than 3 seconds. Remark: When switching the instrument on the formation of the gliding mean value starts automatically. After a calculation phase of 10 seconds, in evidence by the blinking sign + in the LCD-display, the current gliding mean value is available. 3-6 021404/07/04

5 Maintenance After appropriate operation/mounting the instrument works maintenance-free. Heavy pollution can lead to adhesion in the slit between the rotating and stationary parts of the wind transmitter. This slit must always be kept clean. Battery Replacement When the battery voltage is insufficient, in the display appears LOBAT. In this case, the battery must be replaced. A battery compartment is situated on the back side of the instrument. When this compartment is open, the battery is visible, and can be replaced with a new one. 4-6 021404/07/04

6 Technical Data Description Techn. Data Wind Transmitter Measuring Range 0,5... 50 m/s Accuracy ± 3% of meas. value or ± 0,5 m/s Electr. output 2... 630 Hz Cable length 0,5 1,5 m (helix cable) Dimensions Ø 135 x 270 Weight 250 g Ambient temperature -30 +70 C (ice-free) Protection IP 54 Display Instrument Accuracy Resolution Measuring value Display Instrument Display Dimension m/s Battery status LOBAT Exceeding of measuring range 199,9 Identification of gliding mean value + Gliding mean value in calculation + blinking 1 Digit 0,1 m/s Wind speed as instantaneous value or 10 s gliding mean value: LCD display 3 digits, 7 segments, 11,5 mm high General µc-technology Compensation of responsiveness Battery control Current supply 9 V-, alkali-manganese battery connection 5 pole plug Ambient temperature 0... 60 C Dimensions 145 x 80 x 35 (l x b x h) Weight 190 g Protection IP 50 Transport case Material Plastics Dimensions 420 x 330 x 130 (l x b x h) Weight 2 kg 5-6 021404/07/04

7 Accessory (optional) The following accessories are available for the Digital Anemometer: Telescope Serves as extended handhold of the wind transmitter in order to carry out measurements also at places difficult to reach. 4.3405.50.007 length: 0,45 1,45 m Replacement battery 9V 200 030 TYPE: E-block, 6LR61 Certificate of Compliance acc. to DIN 500-49-2.3 T435XXXX 2.3 16 measurement points in the range from 1 to 16 m/s ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany P.O. Box 3536 + 3541 37025 Göttingen Phone +49 551 79001-0 Fax +49 551 79001-65 www.thiesclima.com info@thiesclima.com - Alterations reserved- 6-6 021404/07/04