SECTION COOKING EQUIPMENT

Similar documents
SECTION CUSTOM FABRICATED EQUIPMENT

1. Field measurements must be taken to verify existing conditions prior to installation.

A. This Section includes plumbing fixtures and related components.

MARK V XCEL SERIES ELECTRIC CONVECTION OVEN REPLACEMENT PARTS LIST

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

Effective october 14, 2014

COMMERCIAL KITCHEN HOOD WORKSHEET/ CHECKLIST

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

SECTION FUEL OIL SYSTEM (PLUMBING)

SECTION EQUIPMENT WIRING

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

Table of Contents. Steel Frame Bench...3. Workbench Island Locker Bench Pedestal Bench Table...8. Specialty Project Workstation...

Self Service. Bain Marie on Heated Cupboard - 4 GN. Self Service

SECTION PLUMBING FIXTURES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CATALOG OF REPLACEMENT PARTS

Symphony II Adaptable Table System

TOILET ROOM ACCESSORIES Concrete Unit Masonry Carpentry Ceramic Tile Solid Plastic Toilet Partition.

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

Moveable Workstations. Enterprise KEWAUNEE. encouraging new discovery...worldwide

SECTION PANELBOARDS

DESIGN INSTRUCTIONS TO ARCHITECTS AND ENGINEERS [ ] SCHEMATICS [ ] DESIGN [ ] CONSTRUCTION

SECTION WOOD DOORS

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

PRODUCT PRICE LIST 2017

Sitting Height Base Cabinets

Important Information Read Before Use Please Save These Instructions! CAUTION

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

Quotations Frank McQue e:

Solutions AGRICULTURAL LABORATORY & CLASSROOM FURNITURE. Education to Industry. Solutions for Your Workspace & Storage Needs

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Installation Instructions

Compact. Pre-Installation guide. Video. Complete Walkthrough. Scanomat Download Center. Scanomat Connection Diagram

SECTION BULLET- RESISTANT DOORS

VARIABLE FREQUENCY DRIVE SPECIFICATION

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

SECTION PRECAST CONCRETE STRUCTURES

Recommended Guidelines for Foodservice Equipment Catalog Specification Sheets

*********************************************************************************************************

High-Speed Oven. E30SO75ESS designer series

Reliance SG800 Series Steel Water Gage Valves

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - FIXTURES AND TRIM

DISPLAY UNITS (HEATED/CHILLED)

Installation Instructions

Product Guide Specification

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO.

CW-Type Wall Mounted Cabinets Installation Instructions

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

B. Manufacturers: Square-D, G.E. or Westinghosue.

SUPPLEMENT 2 TO SECTIONS 14 & 15

Installation Instructions

PAINTING OF UNPAINTED SURFACES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Installation Instructions

SECTION SWINGING AUTOMATIC ENTRANCES

READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION

AIR ACTIVATED MODULAR INLET

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

***************************************************************************************************************

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

B. American Society for Testing and Materials (ASTM):

The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the Owner.

SECTION LIGHTING PART 1- GENERAL

Music Area Casework General 1.01 Summary Related Sections Definitions Qualifications and Quality Assurance

Description CHROME CHROME AIRGAP ANTIQUE BRASS ANTIQUE BRASS AIRGAP ALMOND ALMOND AIRGAP BRUSHED BRONZE BRUSHED BRONZE AIRGAP

WASHROOM ACCESSORIES 2013 CATALOG

Enterprise ADAPTABLE KEWAUNEE MOVEABLE WORKSTATIONS. encouraging new discovery

19-in. Mini-Rack Cabinet, Type 1

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

MANUFACTURING INC. Specifications

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

St. Monica Food Pantry

STEEL BLASTER CABINET FLOOR MODEL

6000 Series Modular Cabinetry

Protector Standard Base Storage Cabinets are utilized for general storage and are not recommended for corrosive or flammable materials.

Standard Product. Free-Stand Cabinets 19-in. Mini-Rack Cabinet, Components and Accessories

SECTION ARCHITECTURAL WOOD CASEWORK

1. This Section specifies the ethernet Category 5E data cabling system for buildings and structures.

SINGLE-PHASE VSV SWITCH

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Metal Components Incorporated

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

PARTS LIST ELECTRIC BOILERS MODELS: CE24 CE36 CE42 CE48 CE324 CE336 CE342 CE348

1. Show the following information with additional information necessary to indicate shop compliance with the requirements of this section.

Cascade Ph: Casework Fax: Corp

ADDENDUM TO THE CONTRACT. for the GLACIER FIRE STATION KITCHEN AND CLASSROOM RENOVATION. Contract No. E16-181

Installation Instructions

Installation. Maintenance QC2-3 QC2-20 QC2-40 QC QC2-100 remote. Model: PROCESSING FREEZER/CHILLER/REFRIGERATION SYSTEM

Enterprise ADAPTABLE. KEWAUNEE encouraging new discovery MOVEABLE WORKSTATIONS

GE Monogram. Installation. Instructions. Microwave Oven. Under Cabinet Installation. and. JX827 Series Built-In Kit. Models.

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM CASEWORK

Michigan State University Construction Standards WIRING DEVICES PAGE

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

DETAILED STILE AND RAIL WOOD DOOR SPECIFICATION

CATALOG OF REPLACEMENT PARTS

Reliance SG777 Series Steel Water Gage Valves

Transcription:

SECTION 11405 COOKING EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 11401 - Custom Fabricated Equipment. 2. 11419 - Utility Distribution Systems. 3. Division 15 - Water supply, drainage, gas, and related piping. 4. Division 16 - Electrical connections. 1.02 REFERENCES: A. National Sanitation Foundation (NSF). B. Underwriters Laboratories Listing (UL). C. National Electrical Manufacturers Association (NEMA). 1.03 SUBMITTALS A. Submit manufacturer's name, descriptive data, mechanical connections required, and other information necessary for review of standard manufactured articles and equipment before starting work. B. Shop Drawings: 1. Dimensioned plans prepared in minimum 1/4" scale. 2. Include accurately dimensioned details and locations of any special wall openings required by items of equipment extending through walls. 3. Include plans, elevations and sections, all dimensioned and suitable to be used for actual construction of items specified. 1.04 QUALITY ASSURANCE A. Source Quality Control: 1. Manufacturer: Provide equipment manufactured by one manufacturer except where otherwise noted, uniform throughout as to method and type of construction used. 2. Nameplates: Project No. SPECIFICATION GUIDELINES 11405-1

a. Identify model and manufacturer with appropriate nameplates. b. Show electrical characteristics on appropriate nameplates. 1.05 PROJECT CONDITIONS A. Existing equipment designated to be removed from the project site shall be disconnected, packed, and delivered to a Board designated location within Miami-Dade County, Florida, before starting the Work. PART 2 PRODUCTS NOTE TO SPECIFIER: Equipment is subject to change. The A/E shall verify current equipment selection with M-DCPS Food and Nutrition. 2.01 EQUIPMENT A. School Food Service Equipment: NOTE TO SPECIFIER: Provide 2 following convection ovens at each elementary school, 3 at each middle school, and 4 at each high school. 1. Item No., Two Stack Convection Oven: each. a. Blodgett Model Zephaire G or accepted equivalent, with porcelain steel liners, stainless steel doors with glass panels and stainless steel front, left side, right side, top and back panels (each stack 55,000 BTU, 120/60/1PH, 1/3 HP, 9.0 amps). b. Flexible utility connectors furnished with UDS Item No.. 2. Item No., Convection Steamer: One each. a. Cleveland Range Model 24-CGM-200 or Market Forge Co. 3500M36G300A, with finishes and accessories standard to manufacturer. 125,000 BTU, 115/60/1PH, 1/4" cw, 1-1/2" drain, 25 watts per compartment, 50 watts boiler controls. b. Filtration System: 3/8" FPT inlet, 1/2" MPT outlet, up to 1.5 service flow rate, pressure range 20 to 125 psi, NSF certified. Kleensteam by Everpure, Project No. SPECIFICATION GUIDELINES 11405-2

Westmony, IL., or accepted equivalent. c. Flexible utility connectors furnished with UDS Item No.. 3. Item No., Tilting Steam Jacketed Kettle: 2 each. a. Cleveland Model KGL-40-T or Groen DH-40, stainless steel unit, gas fired complete with hot and cold water, swing spout, kettle brush kit, counter balanced spring assisted hinged domed stainless steel kettle cover, elevator type pan support, 2" tangent draw-off with a drain strainer, detachable pan carrier, other trim fittings and other devices standard to the manufacturer necessary for complete operation (100,000 BTU). NOTE TO SPECIFIER: In the following paragraph 4, use of the tilting/braising pan in place of 1 tilting kettle will be determined by M-DCPS Food and Nutrition and the A/E on a per project basis. 4. Item No., Tilting/Braising Pan, 1 each. a. Cleveland Model SGL-30-T4 or accepted equivalent, gas fired, 30 gallon capacity, food strainer for pouring spout, s/s clad cooking surface guaranteed against warping, s/s construction, easy to clean, adjustable thermostat control with range of 100 degrees F to 425 degrees F. Separate main power on/off switch, hot/cold mounted faucet with swing spout, tangent draw-off value for draining. NOTE TO SPECIFIER: In the following paragraph 5, the particular model of deep fry combination with fryer drain cabinet will be determined by M-DCPS Food and Nutrition and the A/E on a per project basis and only used at high schools. 5. Item No., Deep Fry Combination with Fryer Drain Cabinet and Built-In Filter System: a. By Dean, Frymaster, or Keating, with inset frypot covers, one set of heavy duty casters, and with filter unit on right side (120,000 BTU per pot) (120/60 PH.). Project No. SPECIFICATION GUIDELINES 11405-3

6. Item No., Electric Heavy Duty Expando Range: One each. a. Toastmaster Model #RA 12x4 or accepted equivalent, with polished stainless steel cabinet base, 6" stainless steel legs with adjustable bullet feet, and hinged door with magnetic latch. NOTE TO SPECIFIER: Verify Food Lab equipment with M-DCPS Department of Applied Technology. B. Foods Lab Commercial Cooking Center Equipment: 1. Item No., Convection Oven: a. Market Forge Model 4200, or accepted equivalent, with 4 stainless steel feet for mounting on top of Item No. (208/60/3PH, 5 KW). 2. Item No., Deep Fat Fryer: a. Wells "Spacesaver" Model F049, or accepted equivalent, with adjustable legs for mounting on top of Item No. (208/60/1PH, 4.5 KW). 3. Item No., Griddle: a. Wells "Powerline" Model G-13, or accepted equivalent, with adjustable legs for mounting on Item No. (208/60/3PH, 9KW). 4. Item No., Convection Steam Cooker: a. Market Forge "Ultra Steam" Model 9200 CTE, or accepted equivalent, with In-line Water Conditioner and with 4" legs for mounting on top of Item No. (9 KW, 208/60/3PH). Project No. SPECIFICATION GUIDELINES 11405-4

PART 3 EXECUTION 3.01 INSPECTION A. Do not proceed with the work of this section until conditions detrimental to the proper and timely completion of the work have been corrected in an acceptable manner. 3.02 INSTALLATION A. Deliver equipment to job site, uncrate, or unpack and set in place ready for connection to utilities. B. Install flexible connectors furnished with Section 11420 - Utility Distribution and Canopy Ventilation System. END OF SECTION Project No. SPECIFICATION GUIDELINES 11405-5