HIGH-MU POWER TRIODE 3CW40,000A7

Similar documents
MEDIUM-MU AIR-COOLED POWER TRIODE 3CX15,000H3

HIGH-MU AIR-COOLED POWER TRIODE 3CX1500D7

RADIAL BEAM POWER CPI RADIAL 4CW50,000J BEAM POWER TETRODE 4CX20,000C

LIQUID-COOLED POWER CPI LIQUID-COOLED 4CW50,000J POWER TETRODE 4CW30,000B

4CM500,000G MULTIPHASE-COOLED POWER TETRODE

L A B O R A T O R I E S 9740 COZYCROFT AVENUE * CHATSWORTH * CALIFORNIA (800) * (818) * FAX: (818)

YC-179 / YC-179A CPI HIGH-MU 4CW50,000J POWER TRIODE YC-179 / YC-179A

Svetlana 4CX7500A Radial Beam Power Tetrode

PL8877/ 3CX1500A7 High-Mu Power Triode

TECHNIlCAL DATA. Amperes Cathode Heating Time..300

9007 Power Tube. VHF Linear Power Amplifier Tube 33 Kilowatt Peak Sync Output Thru VHF-TV Band

WATER COOLED POWER TETRODE 8974

4X150A/7034 Radial Beam Power Tetrode

4-400C/6775 Radial Beam Power Tetrode

8984 Power Tube. VHF Linear Beam Power Tube

Svetlana 3CX3000F7/8162 High-Mu Power Triode

MULTI-PHASE COOLED POWER TETRODE

8988 Power Tube. Linear Beam Power Tube

Power Tube. Beam Power Tube

PET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F

8121 Power Tube. Linear Beam Power Tube

PET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F

8807 Power Tube. Beam Power Tube

8072 Power Tube. VHF Linear Amplifier Tube. Coaxial-Electrode Structure Ceramic-Metal Seals Full Input to 500 MHz Conduction Cooled

2 5 1 A Va c u u m T u b e

M5028 Precision Tuned Magnetron

Western Electric D V a c u u m T u b e

4662 Power Tube. Linear Beam Power Tube

YD1195/8913 YD1197/8937 RF Power Triodes

4665 Power Tube UHF Pulsed Power Amplifier Tube

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

Filament Thoriated tungsten. Filament voltage...14 volts Nominal filament current... 6 amperes Average thermionic emission...

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

8791/V1 Power Tube. VHF-TV Amplifier Tube

8791 Power Tube. Linear Beam Power Amplifier Tube

Transmitter Triode RS 2041 V YD 1262

8792 Power Tube. Linear Beam Power Amplifier Tube

MG7095 Tunable S-Band Magnetron

Transmitter Tetrode. Approx. weight 16 kg. 360 Siemens Aktiengesellschaft. ➀ Tube support ➁ Air inlet ➂ Do not use as terminal.

Western E/ectrk A V a c u u m T u b e

E2V Technologies MG6028 Fast Tuned Magnetron

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

Abridged Data. General Data. MG7095 Tunable S-Band Magnetron for Switched Energy Applications. Cooling. Electrical. Accessories.

Siemens Aktiengesellschaft 137

General Data Electrical Heater for Oxide-Coated Unipotential Cathode: Voltage (AC or DC) 26.5 ± 10% Current at 26.5 volts

MG5223F S-Band Magnetron

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

The AMK 15-2 is a high-power metal/ceramic triode, intended for use in industrial generators for frequencies

Siemens Aktiengesellschaft 211

2 5 4 A V a c u u m T u b e

6884 Power Tube. Beam Power Tube

MG5193 Tunable S-Band Magnetron

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER TYPES 7203 AND 7203A

E2V Technologies MG5223F S-Band Magnetron

Transmitter Tetrode RS 1034

Siemens Aktiengesellschaft 101

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER TYPE 8660

Instruction Manual OM3500 HF SHORTWAVE POWER AMPLIFIER. OM POWER, s. r. o Bác 126 SLOVAKIA

E2V Technologies CX1725, CX1725X Liquid Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

Siemens Aktiengesellschaft 299

E2V Technologies MG5222 X-Band Magnetron

MG6090 Tunable S-Band Magnetron

Transmitter Tetrode TH 347

Preliminary Ver. 1.16A

90 Siemens Aktiengesellschaft

MG MW S-Band Magnetron

E2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron

186 Siemens Aktiengesellschaft

Transmitter Tetrode. Approx. weight 1,1 kg Packing dimensions: approx. 310 mm 310 mm 320 mm. Siemens Aktiengesellschaft 375

Broadband Power Amplifier

BTM Series Pulsed RF Power Amplifier Modules. Application Note

Central Electronics Model 600L Linear Amplifier

E2V Technologies M5187F X-Band Magnetron

411LA Broadband Power Amplifier

Rotating Anode X-Ray Tube Housing Assembly. General Data

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D Herxheim Tel. (07276) FAX 6978

SECTION NEUTRALIZATION BELOW VHF NEUTRALIZATION

CX1140 Hydrogen Thyratron

A 100-Watt Transmitter Using a Pair of VT1625s

PA8HF power amplifier Operating guide

How Vacuum Tubes in Linear Circuits Work

A 75-Watt Transmitter for 3 Bands Simplified Shielding and Filtering for TVI BY DONALD H. MIX, W1TS ARRL Handbook 1953 and QST, October 1951

Transmitter Tetrode RS 2078 SK TH 558

USER MANUAL. Maxwell Technologies BOOSTCAP Energy Storage Modules. User Manual for 15V Modules: 20 F, 23 F, 53 F, 58 F 15 Volts DC


8854 Photomultiplier. 129-mm (5-inch) Diameter, 14-stage QUANTACON TM Type Having a Bialkali Photocathode and High- Gain Gallium-Phosphide Dynodes

MOXTEK. 50kV 10 Watt MAGNUM X-ray Source. X-ray Sources. Contents

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

Wilcoxon Research PA8HF power amplifier Operating guide

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B

2 1 2 E V a c u u m T u b e

COMMANDER HF-2500 COMMANDER HF-2500 MAGNUM. Owner s Manual. PALSTAR, INC. Command Technologies Division 9676 N. Looney Road Piqua, Ohio U.S.A.

TX Miniature Triggered Spark Gaps Description and Use Application Note

PMT/UMT(275) Power Gap Description and Use Application Note

M5187 X-Band Magnetron

ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :

Downloaded from MILITARY STANDARD CAPACITORS, SELECTION AND USE OF

PLEASE READ THIS MANUAL BEFORE ATTEMPTING TO OPERATE EQUIPMENT!!

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

CBA 400M MHZ to 400 MHZ

Transcription:

TECHNICAL DATA HIGH-MU POWER TRIODE 3CW40,000A7 The EIMAC 3CW40,000A7 is a ceramic/metal power triode designed for use as a high power RF amplifier for industrial and scientific applications. The high-mu grid in this tube provides excellent isolation and permits stable operation as a grounded grid linear amplifier in class AB or B. With simple cathode bias the tube operates in class C for high efficiency. Its water-cooled anode has a maximum dissipation rating of 40 kilowatts. GENERAL CHARACTERISTICS 1 ELECTRICAL Filament: Thoriated Tungsten Mesh Voltage...12.0 ± 0.6 V Current @ 12.0 Volts... 110 A Direct Interelectrode Capacitances (grounded grid) 2 Cin...79.5 pf Cout...46.5 pf Cgp...0.27 pf Amplification Factor, Average... 200 Frequency of Maximum Rating (CW)... 110 MHz Frequency of Reduced Ratings (CW)...200 MHz MECHANICAL Overall Dimensions: Length... 12.25 in; 311 mm Diameter... 6.75 in; 171 mm Net Weight...17 lb; 7.7 kg Operating Position... Vertical, base up or down Maximum Operating Temperature: Ceramic/Metal Seals & Envelope... 250ºC Cooling...Water & Forced Air Base... Coaxial Recommended Air Socket for Grounded Grid SK-1320 1 Characteristics and operating values are based upon performance tests. These figures may change without notice as the result of additional data or product refinement. CPI Eimac Division should be consulted before using this information for final equipment design. 2 Capacitance values are for a cold tube as measured in a special shielded fixture in accordance with Electronic Industries Association Standard RS-191.

RADIO FREQUENCY LINEAR AMPLIFIER CATHODE DRIVEN ABSOLUTE MAXIMUM RATINGS: Anode Voltage...12.0 Anode Current...9 Grid Voltage...-1.2 Anode Dissipation...40 Grid Dissipation...750 kvdc Adc kvdc kw W TYPICAL OPERATION, below 30 MHz Class AB 2 Anode Voltage...8.0 10.0 kvdc Anode Current...8.0 8.1 Adc Grid Bias Voltage...-10-40 Vdc Grid Current *...0.51 0.46 Adc Driving Power *...1700 1800 W Anode Output Power *...40 54 kw Approx. Load Impedance...690 705 Ohms *Approximate Values RADIO FREQUENCY POWER AMPLIFIER CATHODE DRIVEN TYPICAL OPERATION, below 30 MHz Class C ABSOLUTE MAXIMUM RATINGS: Anode Voltage...12.0 kvdc Anode Current...9.0 Adc Grid Voltage...-1.2 kvdc Anode Dissipation...40 kw Grid Dissipation...750 W *Approximate Values Anode Voltage...10.0 12.0 kvdc Anode Current...6.6 7.7 Adc Cathode Bias Voltage...150 150 Vdc Grid Current*...0.53 0.56 Adc Cathode Impedance...30 27 Ohms Driving Power*...2300 3200 W Anode Load Impedance...800 780 Ohms Anode Output Power*...37.5 76 kw NOTE: TYPICAL OPERATION data are obtained from direct measurement or by calculation from published characteristic curves. Adjustment of the rf grid voltage to obtain the specified anode current at the specified bias and anode voltages is assumed. If this procedure is followed, there will be little variation in output power when the tube is changed. RANGE VALUES FOR EQUIPMENT DESIGN Min. Max. Filament Current @ 12.0 volts... 109 115 A Interelectrode Capacitances 1 (grounded grid) Cin... 72.0 81.5 pf Cout... 42.0 51.5 pf Cgp... -- 0.33 pf 1 Capacitance values are for a cold tube as measured in a shielded fixture in accordance with Electronic Industries Association Standard RS- 191. 2

APPLICATION MOUNTING & SOCKETING The tube must be operated with its axis vertical. The base of the tube may be up or down at the option of the equipment designer. The tube contains a thoriated-tungsten mesh filament and, although more rugged than other types of filament structures, it should be protected from shock and vibration. STORAGE If a tube is to be stored as a spare it should be kept in its original shipping carton, with the original packing material, to minimize the possibility of handling damage. Before storage a new tube should be operated in the equipment for 100 to 200 hours to establish that it has not been damaged and operates properly. If the tube is still in storage 6 months later it should be operated in the equipment for 100 to 200 hours to make sure there has been no degradation. If operation is satisfactory the tube can again be stored with great assurance of being a known-good spare. COOLING - The tube anode is cooled by circulating water through the water jacket. The table below shows minimum water flow rates for various anode dissipation levels. The cooling water inlet temperature should not exceed 50ºC, and system pressure should never exceed 50 psi (3.4 bar). Outlet water temperature must never exceed 70ºC. When the tube is mounted with the anode up the outer cooler pipe should be used as the water inlet. If the tube is mounted anode down the center cooler pipe should be used as the water inlet. ANODE FLOW PRESSURE DROP POWER KW gal/min liters/min psi mbar 0 3 11.3 3 206 20 15 56.8 19 1309 30 16 60.6 21 1446 40 17 64.4 24 1654 A major factor affecting long life of water-cooled tubes is the condition of the cooling water. If the water is contaminated deposits will form on parts of the anode and water jacket and can cause localized heating of the anode and eventual failure of the tube. Cooling water must be well filtered with effectiveness equivalent to a 40-mesh screen to avoid the possibility of blockage of any cooling passages. Ideally, to insure minimum electrolysis, water resistivity should be maintained above one megohm per cubic centimeter at 25ºC. Water resistivity can be continuously checked in the reservoir by readily available instruments. A relative water resistance check can be made continuously by measuring the leakage current which will bypass a short section of the insulating hose column if metal nipples or fittings are used as electrodes. Eimac Application Bulletin #AB-16, Water Purity Requirements in Liquid Cooling Systems, is available on request; it contains considerable detail on purity effects and system maintenance. Forced-air cooling of the base is also required with 100 cfm (3.0 m 3 /minute) of air at 50ºC maximum directed into and around the base of the tube to cool the grid and filament contact and seal areas. Application Bulletin #AB-20, Temperature Measurements with EIMAC Power Tubes, is available on request and gives measurement technique information. Both anode and base cooling must be applied before or simultaneously with electrode voltages, including the filament. Cooling should normally continue about three minutes after removal of electrode voltages to allow the tube to cool down properly. STANDBY OPERATION - Coolant must be circulated through the anode water jacket whenever filament power is applied even though no other voltages are present. Sixty to eighty percent of the filament power appears as heat in the anode. In the absence of coolant flow temperatures will rise to levels which are detrimental to the tube. If the coolant lines become obstructed the coolant jacket may actually rupture from generated steam pressure. A coolant flow interlock circuit that interrupts power to the filament when flow drops below the minimum value is highly recommended. ABSOLUTE MAXIMUM RATINGS - Values shown for each type of service are based on the absolute system and are not to be exceeded under any service conditions. These ratings are limiting values outside which serviceability of the tube may be impaired. In order not to exceed absolute ratings the equipment designer has the responsibility of determining an average design value for each rating below the absolute value of that rating by a safety factor so that the absolute values will never be exceeded under any usual conditions of supply-voltage variation, load variation, or manufacturing variation in the equipment itself. It does not necessarily follow that combinations of absolute maximum ratings can be attained simultaneously. 3

FILAMENT OPERATION - This tube is designed for commercial service, with no more than one normal off/ on filament cycle per day. If additional cycling is anticipated it is recommended the user contact Application Engineering at CPI/Eimac for additional information. With a new tube, or one that has been in storage for some period of time, operation with filament voltage only, at the nominal value of 12.0 volts, applied for a period of 30 to 60 minutes is recommended before full operation begins. This allows the active getter material mounted within the filament structure to absorb any residual gas molecules which have accumulated during storage. Once normal operation has been established a minimum filament warm-up time of five seconds is normally sufficient. At rated (nominal) filament voltage the peak emission capability of the tube is many times that needed for communications service. A reduction in filament voltage will lower the filament temperature, which will substantially increase life expectancy. The correct value of filament voltage should be determined for the particular application. It is recommended the tube be operated at full nominal voltage for an initial stabilization period of 100 to 200 hours before any action is taken to operate at reduced voltage. The voltage should gradually be reduced until there is a slight degradation in performance (such as power output or distortion). The voltage should then be increased a few tenths of a volt above the value where performance degradation was noted for operation. The operating point should be rechecked after 24 hours. Filament voltage should be closely regulated when voltage is to be reduced below nominal in this manner, to avoid any adverse influence by normal line voltage variations. Filament voltage should be measured at the tube base or socket, using an accurate rms-responding meter. Eimac Application Bulletin #AB-18, Extending Transmitter Tube Life, gives information on the effect of filament voltage on life expectancy. When cold, the resistance of a thoriated tungsten filament is very low, therefore the initial starting (inrush) current when filament voltage is applied can be many times the normal (hot) current; this can be detrimental to the longevity of a filament structure. Filament inrush current should never exceed a value of twice the nominal rated current. The use of a special impedance-limited filament transformer or other step-start circuitry in the supply side (primary) of the filament transformer is recommended. though no other voltages are applied to the tube. ZERO-BIAS OPERATION - With anode voltage less than approx. 6000 Volts the 3CW40,000A7 may be used with no external bias voltage; under these conditions the static (no signal) anode dissipation will be several kilowatts. This value may be reduced by using bias voltage to decrease the resting anode current while increasing anode efficiency. Zener diodes (or a string of series connected forward-biased rectifier diodes) may be employed in the cathode return for this purpose. An external power supply may also be used to apply voltage to the cathode, and in this case polarity must be negative with respect to the grid. In class C service a resistor in the dc cathode return can be employed to establish the necessary cathode bias. INPUT CIRCUIT When operated as a cathode-driven amplifier, the use of a resonant circuit in the cathode is recommended. For best results with a linear amplifier, it is suggested the cathode matching network have a Q of 2 or more. GRID OPERATION The maximum allowable grid dissipation for the 3CW40,000A7 is 750 Watts, determined approximately by the product of the dc grid current and the peak positive grid voltage. This value should not be exceeded except during tuning for very short periods. A grid over-current protection circuit with interlock set to trip-off above approx. 1.5 Amperes should be provided; the actual value of current used for the trip point depends on the value of anode current that occurs during normal operating conditions. A protective spark-gap device should be connected between the dc cathode return and ground to help guard against excessive voltage that may exist under fault conditions. FAULT PROTECTION - In addition to normal cooling interlocks and anode and grid over-current interlocks, it is good practice to protect the tube from internal damage which could result from potential arcing at high anode voltage. In all cases some protective resistance, at least 5 ohms, should be used in series with the tube anode to absorb power supply stored energy in case an arc should occur. An electronic crowbar, which will discharge power supply capacitors in a few microseconds after the start of an arc, may be required. The test for each electrode supply is to short each electrode to ground, one at a time, through a vacuum relay switch and a 6-inch length of #30 AGW copper wire. The wire will remain intact if protection is adequate. Eimac Application Bulletin #AB- 17, Fault Protection, contains considerable detail and is available upon request. Note that both anode (liquid) and base (air) cooling is required when the filament of the tube is operating, even 4

INTERELECTRODE CAPACITANCE - The actual internal interelectrode capacitance of a tube is influenced by many variables in most applications, such as stray capacitance to the chassis, capacitance added by the socket used, stray capacitance between tube terminals, and wiring effects. To control the actual capacitance values within the tube, as the key component involved, the industry and the Military Services use a standard test procedure as described in Electronic Industries Association Standard RS-191. This requires the use of specially constructed test fixtures, which effectively shield all external tube leads from each other and eliminates any capacitance reading to ground. The test is performed on a cold tube in a special shielded fixture. Other factors being equal, controlling internal tube capacitance in this way normally assures good interchangeability of tubes over a period of time, even when the tube may be made by different manufacturers. The capacitance values shown in the manufacturer s technical data, or test specifications, normally are taken in accordance with Standard RS-191.The equipment designer is therefore cautioned to make allowance for the actual capacitance values which will exist in any normal application. Measurements should be taken with mounting which represents approximate final layout if capacitance values are highly significant in the design. HIGH VOLTAGE - The 3CW40,000A7 operates at voltages which can be deadly, and the equipment must be designed properly and operating precautions must be followed. Equipment must be designed so that no one can come in contact with high voltages. All equipment must include safety enclosures for high-voltage circuits and terminals, with interlock switches to open the primary circuits of the power supplies and to discharge high-voltage capacitors whenever access doors are opened. Interlock switches must not be bypassed or cheated to allow operation with access doors open. Always remember that HIGH VOLTAGE CAN KILL. RF RADIATION - Avoid exposure to strong rf fields even at relatively low frequency. Absorption of rf energy by human tissue is dependent on frequency. Under 300 MHz most of the energy will pass completely through the human body with little attenuation or heating affect. Public health agencies are concerned with the hazard, and the published OSHA (Occupational Safety and Health Administration) or other local recommendations to limit prolonged exposure of rf radiation should be followed. HOT SURFACES - Air-cooled surfaces and other parts of tubes can reach temperatures of several hundred degrees C and cause serious burns if touched for several minutes after all power is removed. SPECIAL APPLICATIONS - If it is desired to operate this tube under conditions widely different from those given here, contact the Application Engineering Dept., CPI Eimac Division, San Carlos, Calif. 94070 for information and recommendations. OPERATING HAZARDS Proper use and safe operating practices with respect to power tubes are the responsibility of equipment manufacturers and users of such tubes. All persons who work with and are exposed to power tubes, or equipment that utilizes such tubes, must take precautions to protect themselves against possible serious bodily injury. DO NOT BE CARELESS AROUND SUCH PRODUCTS. The operation of this tube may involve the following hazards, any one of which, in the absence of safe operating practices and precautions, could result in serious harm to personnel. HIGH VOLTAGE Normal operating voltages can be deadly. Remember the HIGH VOLTAGE CAN KILL. LOW-VOLTAGE HIGH-CURRENT CIRCUITS - Personal jewelry, such as rings, should not be worn when working with filament contacts or connectors as a short circuit can produce very high current and melting, resulting in severe burns. RF RADIATION Exposure to strong rf fields should be avoided, even at relatively low frequencies. CAR- DIAC PACEMAKERS MAY BE AFFECTED. HOT WATER Water used to cool tubes may reach scalding temperatures. Touching or rupture of the cooling system can cause serious burns. HOT SURFACES Surfaces of tubes can reach temperatures of several hundredºc and cause serious burns if touched for several minutes after all power is removed. MATERIAL COMPLIANCE - This product and package conforms to the conditions and limitations specified in 49CRF 173.424 for radioactive material, excepted package-instruments or articles, UN2910. In addition, this product and package contains no beryllium oxide (BeO). 5

www.eimac.com. Tel: 650.592.1221. Fax: 650.592.9988 01/05 Printed in USA. 8