CLAMP-ON METER 670. User Manual

Similar documents
CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

AC/DC Current Oscilloscope Probe Model SL261

AC/DC Current Probes Model MR411 Model MR521

FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF

DIGITAL MULTIMETER with Non-Contact Detection

DIGITAL MULTIMETER with Non-Contact Detection

MR461 MR561 AC/DC OSCILLOSCOPE CURRENT PROBES. User Manual. AC/DC CURRENT PROBE Model MR 561. AC/DC CURRENT PROBE Model MR V CAT III - 600A

MiniFlex MF MF FLEXIBLE AC CURRENT SENSOR. User Manual

MiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes

CLAMP-ON METER. Models 500, 501, 502, 503, 511, 512 & 514. Call toll free (800) or visit

MEGOHMMETER. User Manual

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS

GROUND FAULT/LEAKAGE DETECTOR

Pince Multimètre. Multimeter Clamp. Multimeterzange. Pinza Multimetro. Pinza Multímetro MX 670 / 675 E N G L I S H. User s manual

User s Guide. 400A AC/DC Clamp Meter. Model MA220

DIGITAL ANALOG MEGOHMMETERS

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Clamp-On Ground Resistance Tester Model 3705

200Amp AC Clamp Meter + NCV Model MA250

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

User Guide. Digital AC/DC Clamp Meter Model 38394

Digital Multimeter Models 5212, 5215 & 5217

User s Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Clamp-On Ground Resistance Tester Models 3711 and 3731 USER MANUAL

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

400Amp True RMS AC Clamp Meter + NCV

Clamp-On Harmonic Probe Model 725 OFF V. Model 725 HARMONIC METER AEMC. TDHF K FACTOR khz AV% ODD RECORD-PAUSE MAX MIN AVG

AC Digital Signal Generator Model DSG-8 User Manual

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

AC/DC CLAMP METER USER S MANUAL

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

DM-45 Digital Multimeter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

DM-46 Instruction Manual

CONTENTS MS2033A. 1.Introduction Safety Information...01

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

312, 316, 318. Clamp Meter. Users Manual

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

400Amp True RMS AC/DC Clamp Meter Model EX613

INSTRUCTION MANUAL UTL260

600A Clamp Meters w/tightsight Display

UT207A/208A/209A Operating Manual. Table of Contents

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

BENNING. CM7 Electrical Tester. Service Information

AMM-1022 Digital Multimeter USER`S MANUAL

MW3105 DIGITAL CLAMP MULTIMETER

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

Not for Reproduction

NOTE: Fully read and understand this manual before using this Digital Multimeter.

User's Manual. Clamp-on Power Datalogger. Model

with the Artifical Neutral AN-1

DVM1190 DIGITAL MULTIMETER

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

MS2030 CAT III 600 V A V AUTO RS232

User Manual Digital Multimeter. model no.: MSR-U1000

DM-46 Instruction Manual

USER'S MANUAL DMR-6700

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

MODEL 3620 GROUND RESISTANCE TESTER. User Manual. Shop for AEMC products online at: Press To Measure C1 P2 C2

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Digital Clamp Meter Model: &

Cable Locator Transmitter/Receiver Model 6681

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Digital Clamp Meter (TRMS) Model : 2727

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

DCM730. Digital Clamp Meter User s Manual

Model: &

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

User Manual Digital Clamp Multimeter. model no.: MSR-C600

F 03. Pince multimètre Clamp multimeter Vielfachmesszange Pinza multimetro Pinza multimetrica

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

902 FC. HVAC True-rms Clamp Meter

USER'S MANUAL DMR-4350

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

MS2109A AC/DC Clamp Meter. User Manual. Contents

DDM350 Pen-Type Digital Multimeter User s Manual

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

79/26 Series III Multimeter

Autoranging Multimeter Extech EX503

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

FLEXIBLE CURRENT PROBES

Digital Clamp Meter. User Manual

Transcription:

CLAMP-ON METER 670 675 E N G L I S H User Manual

Certificate of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met its published specifications. An NIST traceable certificate may be requested at the time of purchase, or obtained by returning the instrument to our repair and calibration facility, for a nominal charge. The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com. Serial #: Catalog #: 2117.49 / 2117.50 Model #: 670 / 675 Please fill in the appropriate date as indicated: Date Received: Date Calibration Due: Chauvin Arnoux, Inc. d.b.a AEMC Instruments www.aemc.com

Table of Contents 1. INTRODUCTION... 3 1.1 International Electrical Symbols... 4 1.2 Definition of Measurement Categories... 4 1.3 Receiving Your Shipment... 5 1.4 Ordering Information... 5 1.4.1 Accessories/Replacement Parts... 5 2. PRODUCT FEATURES... 6 2.1 Description... 6 2.2 Model 670/675 Control Features... 7 2.3 LCD Display... 8 2.4 Button Functions... 9 2.4.1 HOLD Button... 9 2.4.2 Correction of Zero in DC measurement... 9 2.4.3 Auto Power OFF... 9 2.4.4 DISPLAY Button... 10 2.4.5 MIN/MAX Function (500ms)... 10 2.4.6 Peak Function (1ms)... 10 2.4.7 Backlight Button... 10 3. SPECIFICATIONS... 11 3.1 Electrical Specifications... 11 3.2 Mechanical Specifications... 13 3.3 Environmental Specifications... 14 3.4 Safety Specifications... 14 4. OPERATION... 15 4.1 AC Current Measurement... 15 4.2 AC Voltage and Current Measurement Simultaneously... 16

4.3 DC Current Measurement (675 only)...17 4.4 AC Volt Measurement... 18 4.5 DC Volt Measurement... 19 4.6 Resistance Measurement... 20 4.7 Continuity Measurement... 21 4.8 Temperature Measurement... 22 4.9 Frequency Measurement Using Voltage Input... 23 4.10 Frequency Measurement Using Current Input... 24 5. MAINTENANCE... 25 5.1 Warning!... 25 5.2 Cleaning... 25 5.3 Battery Replacement... 25 Repair and Calibration... 27 Technical and Sales Assistance... 27 Limited Warranty... 28 Warranty Repairs... 28

CHAPTER 1 INTRODUCTION Warning Read the user manual before operating and follow all safety information. Only use the meter as specified in this user manual. Never use this meter on a circuit with voltages greater than 600Vrms @ 50/60Hz, CAT IV or 1000V, CAT III. Never measure current while the test leads are connected to the input jacks. Do not operate the meter if the body or test leads look damaged. Check the rotary range switch and make sure it is at the correct position before each measurement. Do not perform resistance and continuity test on a live circuit. Use extreme caution when measuring live systems with voltages greater than 60VDC or 30VAC. Use extreme care when working around bus bars and bare conductors. Do not use the meter in over range/overload conditions ( ). For accurate readings, change the battery when the symbol appears. Clamp-on Meter Models 670 and 675 3

1.1 International Electrical Symbols This symbol signifies that the instrument is protected by double or reinforced insulation. This symbol on the instrument indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument. In this manual, the symbol preceding instructions indicates that if the instructions are not followed, bodily injury, installation/sample and product damage may result. Risk of electric shock. The voltage at the parts marked with this symbol may be dangerous. This symbol refers to a type A current sensor. This symbol signifies that application around and removal from HAZARDOUS LIVE conductors is permitted. Ground. In conformity with WEEE 2002/96/EC. 1.2 Definition of Measurement Categories CAT II: For measurements performed on circuits directly connected to the electrical distribution system. Examples are measurements on household appliances or portable tools. CAT III: For measurements performed in the building installation at the distribution level such as on hardwired equipment in fixed installation and circuit breakers. CAT IV: For measurements performed at the primary electrical supply (<1000V) such as on primary overcurrent protection devices, ripple control units, or meters. 4 Clamp-on Meter Models 670 and 675

1.3 Receiving Your Shipment Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage. Save the damaged packing container to substantiate your claim. 1.4 Ordering Information TRMS Clamp-on Meter Model 670...Cat. #2117.49 Includes meter, set of test leads (red/black with safety needle tips), K-type thermocouple, one 9V battery, soft carrying case and a user manual. TRMS Clamp-on Meter Model 675...Cat. #2117.50 Includes meter, set of test leads (red/black with safety needle tips), K-type thermocouple, one 9V battery, soft carrying case and a user manual. 1.4.1 Accessories and Replacement Parts Soft Carrying Case...Cat. #2118.89 K-type Thermocouple...Cat. #2118.90 Set of 2, 5 ft color-coded leads...cat. #2152.05 Clamp-on Meter Models 670 and 675 5

CHAPTER 2 PRODUCT FEATURES 2.1 Description The AEMC Models 670 and 675 are general purpose professional clamp-on meters that measure up to the toughest standards. These meters offer a complete set of measurement ranges (AC Amps, DC Amps [675 only], AC Volts, DC Volts, Ohms, Continuity with beeper, Frequency from V or A, and Temperature) and are in compliance with international safety and quality standards to ensure professional and reliable measuring tools. These meters are designed to measure and display amps and volts at the same time. They are also auto-ranging and provide the best measurement range and resolution for troubleshooting. The Models 670 and 675 are sized for comfortable, one-handed operation. The tapered and hooked jaw design facilitates maneuvering in crowded wiring and breaker panels, making it easy to select conductors. The jaw opening accommodates one 750 kcmil cable or two 350kcmil cables. The large and easy-to-read 9999- count LCD features comprehensive user information symbols, such as low battery, polarity, overload, and an analog bargraph for easy trend readings. Both models are equipped with a Data Hold function that freezes the measurement for later viewing, Min/Max, and Peak function for capture of signals. The Model 670 and 675 are True RMS clamp-on meters that provide RMS measurements for today s non-linear electrical environments. 6 Clamp-on Meter Models 670 and 675

MIN MAX PEAK 1000V CAT III TRMS CLAMP METER TRMS CLAMP METER 2.2 Model 670/675 Control Features 1 1 2 3 MODEL 670 1000V CAT III 600V CAT IV 1000A HOLD 7 2 3 1000V CAT III 600V CAT IV ZERO Press 2s MODEL 675 1000A 1400A 7 8 8 4 4 DISPLAY DUAL TRMS DISPLAY DUAL TRMS DISPLAY 5 5 1000V CAT III 6 6 1. Jaw Assembly Model 670-1.65" (42mm) Model 675-1.58" (40mm) 2. Safety Barrier Anti-slip Guard 3. Lever for Jaw Opening/Closing 4. Button Functions (see 2.4) 5. LCD Display 6. Positive (red) Input and COM (black) Input 7. Data Hold Button 8. Rotary Range Selector Switch Clamp-on Meter Models 670 and 675 7

2.3 LCD Display Icon AUTO HOLD MIN MAX PEAK ZERO Ω A V C /F Hz Function Automatic Range Freezes the Display Minimum Value Maximum Value Peak Value ADC Zero Function (675 only) DC Input AC Input Auto Power OFF Indication Low Battery Continuity Beeper Enabled Resistance Measurement Indicator Current /Voltage Indicator Degrees Celsius/Fahrenheit Frequency Measurement Indicator 8 Clamp-on Meter Models 670 and 675

2.4 Button Functions 2.4.1 HOLD Button The last reading may be held on the display by pressing the HOLD button. The HOLD symbol will appear when this function is activated. To deactivate, press the HOLD button a second time. 2.4.2 Correction of Zero in DC measurement This function on the Model 675 allows the user to zero out magnetization effects in DC current measurements. This operation must be performed after each high amplitude current measurement. Turn the rotary switch to ADC, with no conductor inserted into the clamp, then press the HOLD button (approximately 2 seconds) until the display shows zero current. This is also indicated by an audio beep and the symbol ZERO on the display. 2.4.3 Auto Power OFF If there is no activity for approximately 10 minutes, the clamp will automatically shut down and the symbol will appear To disable Auto Power OFF function, turn the rotary switch to OFF. Press and hold down the HOLD button and set the rotary switch to any position other than OFF. The symbol disappears and Auto Power OFF is deactivated. Clamp-on Meter Models 670 and 675 9

2.4.4 DISPLAY Button When measuring voltage or AC current, pressing the DISPLAY button replaces the measurement shown in the lower display with the frequency measurement of the variable shown in the main display. Pressing again returns to the previous display. In temperature measurement, pressing DISPLAY switches the displays from C to F of the measured temperature. 2.4.5 MIN/MAX Function (500ms) Pressing the MIN/MAX button once will set the meter to MIN mode. Pressing it twice will set the meter to MAX mode. Pressing it three times will set the meter back to normal operation. 2.4.6 Peak Function (1ms) This function is used for measuring 1-ms peak values in voltage or current. To activate the function, press the MIN MAX PEAK button for at least 2 seconds, until PEAK is displayed. To exit this function, press the button again for at least 2 seconds or press the HOLD button twice. The clamp will then return to normal mode. 2.4.7 Backlight Button Press the button once to turn the backlight on. Press it again to turn it off. When backlight is on, the meter will automatically turn the backlight off after approximately 3 minutes. 10 Clamp-on Meter Models 670 and 675

CHAPTER 3 SPECIFICATIONS The tolerances assigned to the values, or declared limits, constitute only the values guaranteed by the manufacturer. Values without a tolerance are for information only. The symbol is displayed when the input signals exceed the limit values possible in each measurement range. The symbol - is displayed in C/ F measurement when there is no input signal (open circuit). 3.1 Electrical Specifications Reference Conditions: 23 C ±3 C, 48 to 65Hz, no DC component, sinusoidal FC = 2, 10% to 100% of range, no external alternative magnetic field, no electrical field, conductor centered in jaws (in A). AC Amperes Range Measuring Range Resolution Accuracy 100A 0.00 to 99.99A 0.01A 1.5% ± 5cts (50 to 60Hz) 2.0% ± 5cts (60 to 500Hz) 1000A 100 to 1000 A 0.1A 4.5% ± 5cts (500Hz to 3kHz) Overload: 1000Arms DC Amperes (Model 675 only) Range Measuring Range Resolution Accuracy 100A 0.00 to 99.99A 0.01A 1.2% ± 5cts 1000A 100.0 to 999.9A 0.1A 1400A 1000 to 1400A 1A 2.5% ± 5cts Overload: 1400ADC Clamp-on Meter Models 670 and 675 11

AC Volts Range Measuring Range Resolution Accuracy 1000V 0.0 to 999.9V 0.1V Input Resistance: 1MW Overload: 1000Vrms 1.0% ± 5cts (50 to 60Hz) 1.2% ± 5cts (60 to 500Hz) 2.5% ± 5cts (500Hz to 3kHz) DC Volts Range Measuring Range Resolution Accuracy 1000V 0.0 to 999.9V 0.1V 1% ± 2cts 1400V 1000 to 1400V 1V Input Resistance: 1MW Overload: 1400vDC Resistance - Ohms (Ω) Range Measuring Range Resolution Accuracy 1000Ω 0.0 to 999.9Ω 0.1Ω 1% ± 3cts 10,000Ω 1000 to 9999Ω 1Ω 3.3VDC (Vmax) Protection: 1000Vrms Continuity ( ) Range Beeper Activation Accuracy Protection: 1000Vrms < 35Ω 1% ± 3cts 3.3VDC (Vmax) Frequency (Hz) Function Range Resolution Sensitivity Accuracy A - Hz 1000Hz 0.1Hz 3Arms 1.0% ± 2cts V - Hz 10,000Hz 1Hz 5Vrms 12 Clamp-on Meter Models 670 and 675

Temperature ( C / F) Range Measuring Range Resolution Accuracy 1000 C -40 to 999.5 C 0.5 C 1200 C 1000 to 1200 C 1 C 1.0% ± 2 C 2192 F -40 to 2192 F 1 F 1.0% ± 4 F Low Battery Indicator: is displayed when the voltage supplied by the battery is lower than the operating voltage. The measurements are then guaranteed for only a short period. Power supply: 9V, NEDA 1604 (6F22) alkaline Battery Life (no buzzer or backlight): 35 hours (670) 30 hours (675) Polarity: displayed when negative signal applied to input 3.2 Mechanical Specifications Digital Display: 3 3/4 digits LCD dual display (max reading 9999) Jaw Opening: 670: 1.65" (42mm) 675: 1.57" (40mm) Dimension (L x W x D): 670: 10.71 x 3.15 x 1.69" (272 x 80 x 43mm) 675: 10.12 x 3.15 x 1.69" (257 x 80 x 43mm) Weight: 670: 17 oz (480g) with battery 675: 15.5 oz (440g) with battery Protection Index of Housing: IP30 according to EN 60529 Ed. 92 Clamp-on Meter Models 670 and 675 13

3.3 Environmental Specifications Altitude: 2000 meters Operating Temperature: -14 to 122 F (-25 to 50 C), 80% RH, non-condensing NOTE: If the meter is to be used below 32 F (0 C), we suggest that the battery be replaced to ensure proper results. Storage Temperature: -14 to 140 F (-25 to 60 C) < 80% RH 3.4 Safety Specifications EN 61010-1 Ed.2001 EN 61010-2-032 Ed.2002 600V CAT IV, 1000V CAT III Pollution Degree 2 Electromagnetic Compatibility (per NF EN 61326) Compliant with electromagnetic compatibility standard NF EN 61326-1 (07/97) + A1 (10/98) + A2 ( 09/2001) - Radiated and conducted emission (NF EN 55022) - Radiated Immunity, criterion B (NF EN 61000-4-3) - Conducted Immunity, criterion A (NF EN 61000-4-6) - Electrostatic discharges, criterion A (NF EN 61000-4-2) - Transients, criterion B (NF EN 61000-4-4) - Shock waves, criterion A (NF EN 61000-4-5) Note: Certain high power radio-electric frequencies are, under certain conditions, capable of interfering with the metrological integrity of the meter. *Specifications are subject to change without notice 14 Clamp-on Meter Models 670 and 675

DISPLAY MIN MAX PEAK 1000V CAT III MODEL 670 TRMS CLAMP METER 1000A HOLD CHAPTER 4 OPERATION 4.1 AC Current Measurement NOTE: Remove the test leads before measuring current if AC voltage is not going to be measured at the same time. Turn the rotary range switch to the Press the lever to open the jaws. range. Clamp the jaws around the conductor to be measured. If reading is unstable and is hard to read, push the HOLD button and read the measurement. WARNING: If overload " " is displayed, unclamp the meter immediately. 1000V CAT III 600V CAT IV DUAL TRMS DISPLAY Clamp-on Meter Models 670 and 675 15

DISPLAY MIN MAX PEAK 1000V CAT III MODEL 670 TRMS CLAMP METER 1000A HOLD 4.2 AC Voltage and Current Measurement Simultaneously Turn the rotary range switch to the or range. Connect the test probe tips to the voltage to be measured. Press the lever to open the jaws. Clamp the jaws around the conductor to be measured. Voltage and current measurements will be displayed simultaneously. If reading is unstable and is hard to read, push the HOLD button and read the measurement. WARNING: If overload " " is displayed, unclamp the meter immediately. 1000V CAT III 600V CAT IV DUAL TRMS DISPLAY 16 Clamp-on Meter Models 670 and 675

4.3 DC Current Measurement (675 only) NOTE: Remove the test leads before measuring current if DC voltage is not going to be measured at the same time Turn the rotary range switch to the range. If needed, the display may be zeroed. Press and hold down the HOLD button for approx 2s. Clamp the jaws around the conductor to be measured. The main display is ADC, the secondary display is VDC. The DISPLAY button is inoperative. If reading is unstable and is hard to read, push the HOLD button and read the measurement. WARNING: If overload " " is displayed, unclamp the meter immediately. MODEL 675 TRMS CLAMP METER 1000V CAT III 600V CAT IV ZERO Press 2s 1000A 1400A DUAL TRMS DISPLAY 1000V CAT III Clamp-on Meter Models 670 and 675 17

MIN MAX PEAK 1000V CAT III TRMS CLAMP METER 4.4 AC Volt Measurement WARNING: Maximum Input Voltage is 600V. Do not exceed this voltage to avoid electrical shock and/or damage to the instrument. Turn the rotary range switch to the range. Insert the red test lead to the red "+" input jack and the black lead to the black "COM" input jack. Connect the test probe tips to the voltage to be measured. If reading is unstable and is hard to read, push the HOLD button and read the measurement. WARNING: Immediately disconnect the meter if overload " " is displayed. MODEL 670 1000V CAT III 600V CAT IV 1000A HOLD DISPLAY DUAL TRMS DISPLAY 18 Clamp-on Meter Models 670 and 675

1000V CAT III 4.5 DC Volt Measurement Turn the rotary range switch to the range. Insert the red test lead to the red "+" input jack and the black lead to the black "COM" input jack. Connect the test probe tips to the voltage to be measured. If reading is unstable and is hard to read, push the HOLD button and read the measurement. WARNING: Immediately disconnect the meter if overload " " is displayed. MODEL 670 TRMS CLAMP METER 1000V CAT III 600V CAT IV 1000A HOLD DISPLAY MIN MAX PEAK DUAL TRMS DISPLAY Clamp-on Meter Models 670 and 675 19

1000V CAT III 4.6 Resistance Measurement Turn the rotary range switch to the range. Insert the red test lead to the red "+" input jack and the black lead to the black "COM" input jack. Bring the test probe tips into contact with the sample under test. WARNING: Immediately disconnect the meter if overload is displayed. WARNING: When making a resistance measurement, make sure that the power is off (dead circuit), and that all capacitors in the measured circuit are fully discharged. MODEL 670 TRMS CLAMP METER 1000V CAT III 600V CAT IV 1000A HOLD DISPLAY MIN MAX PEAK DUAL TRMS DISPLAY 20 Clamp-on Meter Models 670 and 675

DISPLAY MIN MAX PEAK 1000V CAT III TRMS CLAMP METER DISPLAY MIN MAX PEAK 1000V CAT III TRMS CLAMP METER 4.7 Continuity Measurement WARNING: When testing continuity, make sure that there is no power in the tested sample or circuit (dead circuit). This may be checked by using the voltage functions. Turn the rotary range switch to the range. Insert red test lead to the red "+" input jack and the black lead to the black "COM" input jack. Bring the test probe tips into contact with the sample under test. If the resistance is less than 40Ω, the beeper emits a continuous sound. WARNING: Immediately disconnect the meter if overload is displayed. MODEL 670 MODEL 670 1000V CAT III 600V CAT IV 1000A HOLD 1000V CAT III 600V CAT IV 1000A HOLD DUAL TRMS DISPLAY DUAL TRMS DISPLAY Clamp-on Meter Models 670 and 675 21

4.8 Temperature Measurement WARNING: Make sure that there is no power in the tested sample or circuit (dead circuit). Turn the rotary range switch to the TEMP range. To measure the temperature, connect the K-type thermocouple probe to the input terminals, observing the polarity. The main display is in degrees Celsius ( C) by default, and the secondary display in degrees Fahrenheit ( F). The user can change the main display to degrees Fahrenheit ( F) and the secondary display to degrees Celsius ( C) by pressing the DISPLAY button. MODEL 670 TRMS CLAMP METER 1000V CAT III 600V CAT IV 1000A HOLD DISPLAY MIN MAX PEAK DUAL TRMS DISPLAY 1000V CAT III 22 Clamp-on Meter Models 670 and 675

1000V CAT III 4.9 Frequency Measurement Using Voltage Input Turn the rotary range switch to the press the DISPLAY button. range and Insert red test lead to the red "+" input jack and the black lead to the black "COM" input jack. Bring the test probe tips into contact with the sample under test. WARNING: Immediately disconnect the meter if overload is displayed. MODEL 670 TRMS CLAMP METER 1000V CAT III 600V CAT IV 1000A HOLD DISPLAY MIN MAX PEAK DUAL TRMS DISPLAY Clamp-on Meter Models 670 and 675 23

4.10 Frequency Measurement Using Current Input NOTE: Remove the test leads before measuring current if AC voltage is not going to be measured at the same time. Turn the rotary range switch to the the DISPLAY button. Press the lever to open the jaws. range and press Clamp the jaws around the conductor to be measured. WARNING: If overload " " is displayed, unclamp the meter immediately. MODEL 670 TRMS CLAMP METER 1000V CAT III 600V CAT IV 1000A HOLD DISPLAY MIN MAX PEAK DUAL TRMS DISPLAY 1000V CAT III 24 Clamp-on Meter Models 670 and 675

CHAPTER 5 MAINTENANCE 5.1 Warning! Remove the test leads on any input before opening the case. Do not operate the clamp-on meter without a battery case cover. To avoid electrical shock, do not attempt to perform any servicing unless you are qualified to do so. To avoid electrical shock and/or damage to the instrument, do not get water or other foreign agents into the probe. 5.2 Cleaning To clean the meter, wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Do not get water inside the case. This may lead to electrical shock or damage to the instrument. 5.3 Battery Replacement The Clamp-on Meter Models 670 and 675 are powered by a 9V battery. The symbol will appear on the LCD display when the supply voltage drops below proper operating range. This indicates that the battery needs to be changed. Clamp-on Meter Models 670 and 675 25

The meter must be in the OFF position and disconnected from any circuit or input. Place the meter face down and remove the 2 screws with a screwdriver. Replace the old battery with a new 9V battery, making sure of the correct positioning of the wires to prevent any pinching at closing. Replace the battery compartment cover and tighten the screws. 26 Clamp-on Meter Models 670 and 675

Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be submitted to our factory Service Center at one-year intervals for recalibration, or as required by other standards or internal procedures. For instrument repair and calibration: You must contact our Service Center for a Customer Service Authorization Number (CSA#). This will ensure that when your instrument arrives, it will be tracked and processed promptly. Please write the CSA# on the outside of the shipping container. If the instrument is returned for calibration, we need to know if you want a standard calibration, or a calibration traceable to N.I.S.T. (Includes calibration certificate plus recorded calibration data). Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Phone: (800) 945-2362 or (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 repair@aemc.com (Or contact your authorized distributor) Costs for repair, standard calibration, and calibration traceable to N.I.S.T. are available. NOTE: A CSA# must be obtained before returning any instrument. Technical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your instrument, please call, mail, fax or e-mail our technical support hotline: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 200 Foxborough Blvd Foxborough, MA 02035, USA Phone: (800) 343-1391 or (508) 698-2115 Fax: (508) 698-2118 techsupport@aemc.com www.aemc.com NOTE: Do not ship instruments to our Foxborough, MA address. Clamp-on Meter Models 670 and 675 27

Limited Warranty The Models 670 and 675 are warranted to the owner for a period of one year from the date of original purchase against defects in manufacture. This limited warranty is given by AEMC Instruments, not by the distributor from whom it was purchased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC Instruments. For full warranty coverage detail and registration, go to www.aemc.com What AEMC Instruments will do: If a malfunction occurs within the one-year period, you may return the instrument to us for repair or replacement free of charge, provided we have your registration information on file or proof of purchase. AEMC Instruments will, at its option, repair or replace the faulty material. REGISTER ONLINE AT: www.aemc.com Warranty Repairs What you must do to return an Instrument for Warranty Repair: First, request a Customer Service Authorization Number (CSA#) by phone or by fax from our Service Department (see address below), then return the instrument along with the signed CSA Form. Please write the CSA# on the outside of the shipping container. Return the instrument, postage or shipment pre-paid to: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments Service Dept 15 Faraday Dr Dover, NH 03820 USA Phone: (800) 945-2362 or (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 repair@aemc.com Caution: To protect yourself against in-transit loss, we recommend you insure your returned material. NOTE: All customers must obtain a CSA# before returning any instrument. 28 Clamp-on Meter Models 670 and 675

11/15 99-MAN 100335 v7 Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA www.aemc.com