User s Manual. hand-held laser distance meter

Similar documents
ed560l Laser Distance Meter User Manual

Model R8001. Instructionn Manual. Laser Distance Meter. reedinstruments. www. com

AX-DL100 - Laser Distance Meter

USER MANUAL. Laser Distance Meter MODELS DT40M, DT60M, and DT100M

DISTANCE METER

X2 LASER DISTANCE METER. Operating instruction

Table of Contents. Makita LD050P 1

1 Symbols. 4 Foreseeable misuse Do not use the device as a laser pointer. Do not use the device in explosive or aggressive environments.

DE EN FR IT ES RU PL DA NL NO SV

Pipe Laser Model No Instruction Manual

LazerTape 160. Lazer Distance Meter TRIPLETT. Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Manual Laser Range Finder PCE-LDM 44

Table of Contents. Stabila LD 320 1

1. Brief Introduction

IR-829 Infrared Thermometer User Manual

Laser Distance Finder Extech DT500

Bidirectional Ultrasonic Distance Measurement

VC835 DIGTAL MULTIMETER Operation Manual

UT232. Operating Manual. Digital Power Clamp Meter

Model UT233 OPERATING MANUAL

Laser Distance Finder Extech DT500

Dawson DSM150. Digital Light Meter User s Manual

FLUO invisible Ink Densitometer Instruction Manual

Instruction Manual. Self-Leveling Cross-Line Laser Level Model No and

Instruction Manual for Digital Grounding Resistance Meter

INSTRUCTION MANUAL MODEL SAS RS-7 LASER DISTANCE METER

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Model UT511 OPERATING MANUAL

PD-I. English Français Español Português

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

Manifold Electronic Gauge. Model: KC-100B-1 Operation Manual

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

CONTENTS MS2033A. 1.Introduction Safety Information...01

LCR METER Model:

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

Printing Humidity/Temperature Meter

DM-45 Digital Multimeter

Temp. & humidity indicator

Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No

Model: &

Infrared Gun. Perfect For. Easy To Use. Features. Get Professional Results Every Time! Battery Installation. Model: IN1022

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www.

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

GETTING STARTED. Radio layout. LCD display with icons

QUAD 1000 OWNERS MANUAL OPERATION GUIDE

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

312, 316, 318. Clamp Meter. Users Manual

KMD-S04 Multímetro de bolsillo

Multi-beam Self-leveling Line Laser

Revision 1.8 II WARANTY

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

RF/High Frequency Meter HF-A3G

USER MANUAL. Sens it SENS IT 2.4

CONTENT WARNING...1 I INTRODUCTION...3 II ELECTRICAL SYMBOLS...5 III TECHNICAL SPECIFICATIONS...5 IV. STRUCTURE...8 V OPERATIONS...

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

User s Guide. Model MA A AC Mini Clamp-on Meter

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

UT207A/208A/209A Operating Manual. Table of Contents

MANUAL PCE-UT232

Digital Multimeter, Pen Type

INTRODUCTION CHAPTER 1

Revision 1.4 II. Warranty

LCR METER Model:

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

P10 LASER DISTANCE MEASURE. IMPORTANT: Read before Using

PD 5. English Français Español

Leica DISTO TM E7400x The original laser distance meter

? 2 max 3 4 min

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Dawson DDM190. Digital Multimeter User s Manual

Micro-Ohmmeter Model UM200

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) 1327 INSTRUCTION MANUAL

DVM1190 DIGITAL MULTIMETER

User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270

Always there to help you. Register your product and get support at AJ3400/79. Question? Contact Philips.

CONTENT Warning...1 Ⅰ.Introduction...3 Ⅱ. Model...4 Ⅲ. Electrical Symbols...4 Ⅳ.Technical Specification Base Conditions and Working Conditions..

Model : OPERATING MANUAL Table of Contents (1)

Wireless Handy Scanner

Microwave Meter. Instruction Manual

UT231. Operating Manual. Digital Power Clamp Meter P/N:

CLAMP-ON METER 670. User Manual

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Always there to help you. Register your product and get support at AJ3232. Question? Contact Philips.

OVA-50 Optical Variable Attenuator User s Manual

Always there to help you. Register your product and get support at AJ3400/37. Question? Contact Philips.

Model UT201/202: OPERATING MANUAL. Table of Contents

INSTRUCTION MANUAL LM195 LED LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Important safety instructions

Geotagger N3. User Manual (V1.0) Revised by Geosolve.be (Pol F. Gillard) with personal updates and help. Solmeta Technology Co.

Thermo Bluetooth-enabled Thermometer. Model: EMR211 USER MANUAL CONTENTS

Always there to help you. Register your product and get support at AE2430. User manual

Contents ... What is DAB + Digital Radio?... 2 Setting up... 3 Backlit display... 4 Using headphones... 4 Your radio Switch off...

Contents. 1. Safety Description Specifications Operation Instructions Battery Replacement...20.

SMART TWEEZERS Model ST-1 User s Manual Version 1.0

TES-1306 DIGITAL THERMOMETER INSTRUCTION MANUAL 1. SAFETY INFORMATION

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

User Manual Digital Clamp Multimeter. model no.: MSR-C600

MS2030 CAT III 600 V A V AUTO RS232

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

Transcription:

User s Manual hand-held laser distance meter

>1/4 S Safety Regulations Please read the safety regulations and operation guide carefully before operating. Please read all of the operational guide and safety regulations in this manual before operation. Improper operations without complying with this manual guided could cause damage to the device, influence on measurement result or bodily injury to the user. The instrument is not allowed to disassemble or repair in any ways. It is forbidden to do any illegal modification or performance change for laser emitter. Please keep it out of reach of children and avoid using by any irrelevant personnel. It is strictly prohibited to shoot eyes or other parts of body with the laser; it is not allowed take the laser to shoot any objects' surface with strong reflecting. Due to electromagnetic radiation interference to other equipment and devices, please don't use the meter in the plane or around medical equipment, don't use it in inflammable, explosive environment. Discarded batteries or meter device shall not be processed just like household garbage, please handle them in line with related law and regulations. Any quality issues or any questions on the meter, please contact local distributors or manufacturer in time, we are ready to offer solutions for you. Professional casts quality and good quality gets reputation

Batteries Installation, Display and Keyboard Battery Installation and Replacement Discharge the battery door on the back of device, and place battery according to correct polarity, then cover the battery door. Only 1.5 V AAA alkaline battery is applied to the meter. If not used for a long time, please take out the battery to avoid battery corrosion to meter body. Display Laser on Reference Point Maximum Area, Volume and Pythagorean Record Staking-out Power Minimum Continuous Measuring Major Display Auxiliary Display Unit

Keyboard Turn on/ Measuring Addition Area/Volume/ Staking-out Reference Point / Delay Mearsurement Turn off/remove Unit Subtration Pythagorean Measurement Save Back Light Start the Instrument & Menu Setting Turn on / off the Instrument Under off status, press button, device and laser get starting simultaneously and stand by for measurement. Under on status, long press button for 3 seconds to turn the device off. The device can also be shut off without any operation for 150 seconds. Unit setting Press button, reset current measurement unit, the default unit is: 0.000m Backlight Setting Press button, turn the backlight on or off

There are 6 units for selection length area volume Reference Point Press key to change the reference point. There are four reference points: top, screw, bottom and the end piece. Self-Calibration This function can keep the precision of the device. Instruction: Power off, Long press button, and then press, release the button till "CAL" and a figure under it display on the screen. User can adjust the figure with button and according to the accuracy of the meter. Adjusting range: -9 to 9mm.

Length Measurement & Calculation Single Distance Measurement: Turn on the laser beam by short press of the button under measring mode; Press the button again for single measurement of length,then the measured results displayed in the major display area. Continuous Measurement: Long press button under measuring mode and enter into continuous measuring mode. Maximum and Minimum value show on the LCD. Present result displays in major display area. Short press botton to exit continuous measuring mode. Area Measurement: Press button, shows on the screen. One of the side of rectangle blinking on the display, please follow the below instructions for area measuring: Press once for length Press again for width The device calculates and shows the result in the major display area. Press, clear off the result and measuring again if necessary

Volume Measurement Press button twice to enter volume measurement mode. A will shows on the top of screen. Please follow the below instruction for volume measuring: Press for Length Press again for Width Press thirdly for height The device calculates and shows the result in the major display area. Press, clear off the result and measuring again if necessary. Pythagorean Measurement There are four Pythagoras modes in case that user gets difficults to reach the target. Please press button to select the mode. 1. Calculate the second leg by measuring the hypotenuse and another leg.short press to enter Pythagoras mode, the hypotenuse of blinking. Press, measure the length of hypotenuse (a) Press, measure the length of one leg (b) Device calculates the length of another leg (x) 2. Calculate the hypotenuse by measuring the length of two legs.shor press twice, when one leg of blinking, Press, measure the length of one leg (a) Press, measure the length of another leg (b)

Device calculates the length of hypotenuse (x) 3. Press three times till the one hypotenuse of blinking on the screen. Press, measure the length of one side (a) Press, measure the length of the median line (b) Press, measure the length of another side (c) Device calculates the length of the leg in full line (x) 4. Press four times till one hypotenuse of blinking on the screen. Press, measure the length of one hypotenuse (a) Press, measure the length of another hypotenuse (b) Press, measure the length of one leg (c) Device calculates the length of the leg in full line (x)

Legs must short than hypotenuse, or there will be "err" shows on screen. In order to guarantee the accuracy, please make sure all measurements are start from the same point. Addition / subtraction The device can be used for length addition and subtraction. Press, "+" shows in the major display area, entering cumulation mode. Value of last measurement and the result of cumulation will be showed on the screen. Press, "-" shows in the major display area, entering regressive mode. Value of last measurement and the result of difference will be showed on the screen. Not only distance but also area and volume can be added or substracted. For example: Area Addition: Measure the first area, get PIC 1, then press ; Measure the second area, get PIC 2, there is a "+" on the left corner of the screen; At last, press get the addition result as PIC 3. PIC 1 PIC 2 PIC 3 Area Sustraction:The same steps as above.

Staking-out Function Long press, the device switch to staking-out mode. As showed in the below picture, the user can set two difference value a and b; User can adjust these two value by pressing or. Long press or will make you get a large gap of the value when adjust a or b. Press after setting the values, the device enter staking-out mode. User can get instructions by sound and icon. means the device need to go back, means the device need to go forward. When the device get very near to the point, the device will show. Delay Measurement Press, a second number shows in the screen as below picture. User can press or to adjust the time. The max is 60s, min is 3s. Press to turn on the delay measuring function, after certain the delaying time. If press while the laser is on, this function will be turned on at once.

Record Function Long press button for 3s to record your measuring result under measuring mode.it can also record the result under Area, Volume and Pythagoras mode. All the calculating records can be saved by the device. Read / Delete the Record: Short press button, read the records by press button and. Short press to delete recent record and long press to clrear up all the records. Tips You may get some warning information as below: Info message Cause Received signal is too weak Received signal is too strong Solution Chose the surface with stronger reflectance. Use the reflecting plate. Chose the surface with weaker reflectance. Use the reflecting plate. Low battery voltage Change the power supply. The working temperature is out of working range. Use the device in the specified temperature. Pythagoras measuring error. Record damaged Re-measure and ensure that Hypotenuse is bigger than Cathetus. Please contact the distributer.

TECHNICAL DATA Item Working Range Smallest Unit Displayed 40m 60m 80m 100m 0.05 mm Measuring Accuracy Typically ± 1.5 mm ** Continuous Distance Measuring (Tracking) Area / Volume Pythagoras Measuring Length/Area/Volume Addition/Subtraction MAX & MIN Value Skating-Out Delay Measurement Self-Calibration Back Piece Bubble Backlight Laser Laser Type Record Auto Laser Off Auto Switch Off Power Supply Battery Life class II 620-680 nm, < 1 mw 100 pcs 20 s 150 s AAA 2x1.5V Up to 8000 times Storage Temperature -20... +60 С Working Temperature 0 +40 С Storage Humidity Dimensions Specification RH85% 118х54х26.5 mm

** Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties. Instrument Maintenance: The meter should not be stored in high temperature and strong humidity environment for long time; it is not used very often, please take out the battery and place the meter in the allocated potable bag and store in cool and dry place. Please keep the device surface cleaning. Wet soft cloth is applied to clean dust, but erosion liquid is never allowed to use for the meter maintenance. Laser output window and its focus lens can be maintained according to maintenance procedures for optical device. DELIVERY PACKAGE Please check if the accessories are completed according to the below list. NO. Item Unit QTY Note 1 Laser distance meter pc 1 2 Power supply AAA pc 2 3 User' s manual pc 1 4 Portable bag pc 1 5 Hand strap pc 1 6 Giftbox pc 1 7 Reflector pc 1 Just available for 100m