Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner.
600W Single Output ower Supply SE-600 s e ries 3 SECIFICATION MODEL OUTUT INUT ROTECTION ENIRONMENT SAFETY & EMC OTHERS NOTE DC OLTAGE RATED CURRENT CURRENT RANGE RATED OWER OLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETU, RISE TIME HOLD TIME (Typ.) OLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OER LOAD OER OLTAGE OER TEMERATURE WORKING TEM. WORKING HUMIDITY STORAGE TEM., HUMIDITY TEM. COEFFICIENT IBRATION SAFETY STANDARDS WITHSTAND OLTAGE SE-600-5 5 100A 0 ~ 100A 500W RILE & NOISE (max.) Note.2 150mp-p OLTAGE TOLERANCE Note.3 4.75 ~ 5.5 2.0% 0.5% 2.0% 1000ms, 50ms/230AC 20ms/230AC 1000ms, 50ms/115AC at full load 16ms/115AC at full load 90 ~ 132AC / 180 ~ 264AC selected by switch 254 ~ 370DC 47 ~ 63Hz 78% 12A/115AC 25A/115AC <2.0mA / 240AC 7.5A/230AC 50A/230AC 105 ~ 125% rated output power rotection type : Shut down o/p voltage, re-power on to recover 5.75 ~ 6.3 13.8 ~ 16.2 18 ~ 21 27.6 ~ 32.4 31 ~ 36.5 57.6 ~ 67.2 rotection type : Shut down o/p voltage, re-power on to recover 85 5 (TSW1) Detect on heatsink of power transistor rotection type : Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.05%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1 Approved SE-600-12 SE-600-15 SE-600-24 SE-600-27 SE-600-48 12 50A 0 ~ 50A 600W 150mp-p 10 ~ 13.5 15 40A 0 ~ 40A 600W 150mp-p 13.5 ~ 16.5 1.0% 1.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 83% 84% 87% 87% 88% I/-O/:3KAC I/-FG:1.5KAC O/-FG:0.5KAC 150mp-p 22 ~ 26.4 150mp-p 24 ~ 30 200mp-p 43 ~ 56 ISOLATION RESISTANCE I/-O/, I/-FG, O/-FG:100M Ohms/500DC MTBF 197K hrs min. MIL-HDBK-217F (25 ) DIMENSION 247*127*63.5mm (L*W*H) ACKING 2.1Kg; 6pcs/13.4Kg/0.98CUFT 24 25A 0 ~ 25A 600W 27 22.2A 0 ~ 22.2A 599.4W 48 12.5A 0 ~ 12.5A 600W File Name:SE-600-SEC 2006-04-13
600W Single Output ower Supply SE-600 s e ries Mechanical Specification 11.5 18 Case No. 926A Unit:mm 4-M3 L=4 20 30 63.5 11 220 247 230/115AC Air flow direction 8.2 10 I/ 1 2 3 Top view RS O/ 1 2 3 4 5 6 CN4 - + 13 10 127 +Adj. RS - + 220 16 4-M3 L=4 20 30 110 8.5 7.5 137 76 5-M3 L=4 Bottom view 32 207.5 Derating Curve AC input terminal : DC Output terminal : in No. Assignment in No. Assignment 1 AC/L 1~3 + 2 AC/N 4~6-3 FG RS Connector (CN4) : JST B-XH or equivalent in No. 1 2 Assignment +S -S Mating Housing JST XH or equivalent Terminal JST SXH-001T or equivalent Static Characteristics 100 80 60 100 90 80 70 Other 5 LOAD (%) 40 20 LOAD (%) 60 50 40-20 0 10 20 30 40 50 60 70 AMBIENT TEMERATURE ( ) (HORIZONTAL) 90 180 95 190 100 200 115 230 INUT OLTAGE (AC) 60Hz 130 260 File Name:SE-600-SEC 2006-04-13
600W Single Output ower Supply SE-600 series MODEL:SE-600-24 OUTUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 RILE & NOISE 1: 150 mp-p (Max ) I/: 230AC O/:FULL LOAD 1: 61 mp-p (Max ) 2 OUTUT OLTAGE ADJUST RANGE CH1: 22 ~ 26.4 I/: 230 AC I/: 115 AC O/:MIN LOAD 19.43 ~ 28.55 / 230 AC 19.43 ~ 28.55 / 115 AC 3 OUTUT OLTAGE TOLERANCE 1: 1%~ -1% (Max) I/: 200 AC / 264 AC O/:FULL/ MIN LOAD 1: 0.1 %~ -0.1 % 4 LINE REGULATION 1: 0.5 %~ -0.5 % (Max) I/: 200AC ~ 264 AC O/:FULL LOAD 1: 0.03 %~ -0.03 % 5 LOAD REGULATION 1: 0.5 %~ -0.5 % (Max) I/: 230 AC O/:FULL ~MIN LOAD 1: 0.06 %~ -0.06 % 6 SET U TIME 7 RISE TIME 8 HOLD U TIME 230AC: 1000 ms (Max) I/: 230 AC 230AC/ 135 ms 115 AC: 1000 ms (Max) I/: 115 AC 115AC/ 141 ms O/:FULL LOAD 230AC: 50 ms (Max) I/: 230 AC 230AC/ 20 ms 115AC: 50 ms (Max) I/: 115 AC O/:FULL LOAD 115AC/ 23 ms 230AC: 20 ms (TY) I/: 230 AC 230AC/ 24 ms 115AC: 16 ms (TY) I/: 115 AC 115AC/ 19 ms O/:FULL LOAD 9 OER/UNDERSHOOT TEST < +5% I/: 230 AC O/:FULL LOAD 10 DYNAMIC LOAD 1: 2400 mp-p I/: 230 AC O/:FULL /Min LOAD 90%DUTY/1KHZ TEST: <5 % 498 mp-p Model: SE-600-24 Test Report 1 / 5
600W Single Output ower Supply SE-600 series INUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 INUT OLTAGE RANGE 176AC~264 AC I/:TESTING O/:FULL LOAD 130 ~264 I/: LOW-LINE-3= 173 HIGH-LINE+15%=300 O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF ) TEST: OK 2 INUT FREQUENCY RANGE 47HZ ~63 HZ OSC I/:176AC ~ 264 AC O/:FULL~MIN LOAD 3 EFFICIENCY 87 % (TY) I/: 230 AC 4 INUT CURRENT O/:FULL LOAD TEST: OK 87.9 % 230/ 7.5 A(TY) I/: 230 AC I = 6.2 A/ 230 AC 115/ 12 A (TY) I/: 115 AC O/:FULL LOAD I = 10.4 A/ 115 AC 5 INRUSH CURRENT 230/ 50 A(TY) I/: 230 AC I = 44 A/ 230 AC 115/ 25 A(TY) COLD START I/: 115 AC O/:FULL LOAD I = 22 A/ 115 AC 6 LEAKAGE CURRENT < 2 ma / 240 AC I/: 254 AC O/:Min LOAD L-FG: 1.4 ma N-FG: 1.4 ma ROTECTION FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 OER LOAD ROTECTION 105 %~ 125 % I/: 230 AC I/: 115 AC O/:TESTING 120 %/ 230 AC 120 %/ 115 AC Shunt down Re-power ON 2 OER OLTAGE ROTECTION CH1: 27.6~ 32.4 I/: 230 AC I/: 115 AC O/:MIN LOAD 30 / 230 AC 30 / 115 AC Shunt down Re- power ON 3 OER TEMERATURE ROTECTION SEC: 85 + 5 O.T.. I/: 230 AC O/:FULL LOAD O.T.. Active Shut down o/p voltage,recovers automatically after temperature goes down 4 SHORT ROTECTION SHORT EERY OUTUT 1 HOUR I/: 264 AC O/:FULL LOAD Shunt down Re-power ON Model: SE-600-24 Test Report 2 / 5
600W Single Output ower Supply SE-600 series ENIRONMENT TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 TEMERATURE RISE TEST MODEL:SE-600-24 1. ROOM AMBIENT BURN-IN:1HRS I/: 230AC O/: FULL LOAD Ta=29.8 2. HIGH AMBIENT BURN-IN:2HRS I/: 230AC O/: FULL LOAD Ta=49.1 NO osition /N ROOM AMBIENT Ta= 29.8 HIGH AMBIENT Ta= 49.1 1 LF1 TR-348 40.7 58.1 2 BD1 D25XB60 25A/600 46.1 65.1 3 Q3 IRF460 20A/500 77.1 97.5 4 R58 22Ω/2W R/MO 72.4 82.2 5 C5 1000u/200 CAXON 85 37.9 54.8 6 TSW1 ST-85 50.1 68.9 7 T1 coil TF-874 58.6 74.9 8 C13 220U/25 CAX 105 36.0 53.3 9 U2 SG3525A 51.6 69.1 10 L4 TR-321 75.6 92.7 11 R61 680Ω/2W R/MO 98.2 114.0 12 C19 10u/400 CAXON 105 35.4 52.7 13 D16 ESAD92-02 20A/200 60.3 77.9 14 C25 1500u/35 CAXON 105 50.9 68.5 15 ZD1 6KE200A 35.7 53.2 2 OER LOAD BURN-IN TEST 1 HOUR ( MIN ) 3 LOW TEMERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/: 230 AC O/: 120 % LOAD I/: 230 AC O/: 100 % LOAD Ta= -20 TEST:OK TEST:OK 4 HIGH HUMIDITY HIGH TEMERATURE HIGH OLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 40 I/: 272 AC O/:FULL LOAD Ta= 40 HUMIDITY= 95 %R.H + 0.05 %(0~50 ) I/: 230 AC O/:FULL LOAD 6 IBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) TEST:OK + 0.01%(0~50 ) TEST:OK Model: SE-600-24 Test Report 3 / 5
600W Single Output ower Supply SE-600 series SAFETY TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 WITHSTAND OLTAGE I/-O/: 3 KAC/min I/-FG: 1.5 KAC/min O/-FG: 0.5 KAC/min I/-O/: 3.6 KAC/min I/-FG: 1.8 KAC/min O/-FG: 0.6 KAC/min I/-O/: 8.32 ma I/-FG: 7.43 ma O/-FG: 7.54 ma 2 ISOLATION RESISTANCE I/-O/:500DC>100MΩ I/-O/: 500 DC I/-O/: 4 GΩ I/-FG: 500DC>100MΩ O/-FG:500DC>100MΩ I/-FG: 500 DC O/-FG: 500 DC I/-FG: 2 GΩ O/-FG: 2 GΩ 3 GROUNDING CONTINUITY FG(E) TO CHASSIS OR TRACE < 100 mω 40 A / 2min 7 mω 4 AROAL TU: Certificate NO : UL: File NO : N/A E.M.C TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 CONDUCTION EN55022 CLASS B 2 E.S.D EN61000-4-2 INDUSTRY AIR:8K / Contact:4K I/: 230 AC (50HZ) O/:FULL/50% LOAD I/: 230 AC/50HZ O/:FULL LOAD ASS Test by certified Lab CRITERIA A 3 E.F.T EN61000-4-4 I/: 230 AC/50HZ CRITERIA A INDUSTRY INUT: 2K O/:FULL LOAD 4 SURGE IEC61000-4-5 I/: 230 AC/50HZ CRITERIA A INDUSTRY L-N :2K O/:FULL LOAD L,N-E:4K Test by certified Lab & Test Report repare M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 CAACITOR LIFE CYCLE SUOSE C25 IS THE MOST CRITICAL COMONENT I/: 230AC O/:FULL LOAD Ta= 25 LIFE TIME= 360247 HRS I/: 230AC O/:FULL LOAD Ta= 40 LIFE TIME= 143309 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 197K HRS Model: SE-600-24 Test Report 4 / 5
600W Single Output ower Supply SE-600 series COMONENT STRESS TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 ower Transistor ( D to S) or (C to E) eak oltage 2 Diode eak oltage D 14 Rated Q 3 Rated FQA24N50 : 500 24 A S20LC20U : 200 20A 3 Clamp Diode eak oltage D5 Rated BY26E : 1K 4 Control IC oltage Test U2 Rated 3525A : 40 1A I/:High-Line +3 = 267 O/: (1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3 = 267 O/: (1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3 = 267 O/: (1)Full Load (2) Dynamic Load 90%Duty/1KHz I/:High-Line +3 = 267 O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 478 (2) 380 (3) 496 (1) 156 (2) 156 (3) 130 (1) 522 (2) 522 (1) 14.5 (2) 14.5 (3) 14.5 5 ower Transistor ( D to S) or (C to E) eak oltage U4 Rated TO242 : 700 I/:High-Line +3 = 267 O/: (1)Full Load Turn on (2) Full Load (3)Output Short (1) (2) (3) 616 536 602 6 Control IC oltage Test U4 Rated TO242 : 9 I/:High-Line +3 = 267 O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) (2) (3) 5.84 5.84. 5.84 DATE SAMLE TEST RESULT TESTER AROAL 2003/3/4 RD SAMLE ASS INCENT TSENG MAX LIN 2003/4/30 2006/3/22 RODUCT SAMLE A303E35 RODUCT SAMLE W0601B192 ASS INCENT TSENG MAX LIN ASS INCENT TSENG MAX LIN 2003/12/12 A50-F023 Model: SE-600-24 Test Report 5 / 5