Upgrade of Reflectometry Profile and Fluctuation Measurements in Alcator C-Mod

Similar documents
Microwave reflectometry for plasma density profile. measurements on HL-2A tokamak

SOL Reflectometer for Alcator C-Mod

Fast Electron Temperature Diagnostic Based on Langmuir Probe Current Harmonic Detection on D-IIID

PHASE DETECTION USING AD8302 EVALUATION BOARD IN THE SUPERHETERODYNE MICROWAVE INTERFEROMETER FOR LINE AVERAGE PLASMA ELECTRON DENSITY MEASUREMENTS

Microwave Imaging in the Large Helical Device

Development of local oscillator integrated antenna array for microwave imaging diagnostics

GA A24030 ECE RADIOMETER UPGRADE ON THE DIII D TOKAMAK

ICRF Mode Conversion Flow Drive Studies with Improved Wave Measurement by Phase Contrast Imaging

Diagnostic development to measure parallel wavenumber of lower hybrid waves on Alcator C-Mod

Initial Results from the C-Mod Prototype Polarimeter/Interferometer

Investigation of RF-enhanced Plasma Potentials on Alcator C-Mod

Design and commissioning of a novel LHCD launcher on Alcator C-Mod

First Results From the Alcator C-Mod Lower Hybrid Experiment.

Overview of ICRF Experiments on Alcator C-Mod*

Comparisons of Edge/SOL Turbulence in L- and H-mode Plasmas of Alcator C-Mod

Advanced Density Profile Reflectometry; the State-of-the-Art and Measurement Prospects for ITER

Automatic electron density measurements with microwave reflectometry during highdensity H-mode discharges on ASDEX Upgrade

Upper limit on turbulent electron temperature fluctuations on Alcator C-Mod APS DPP Meeting Albuquerque 2003

Development of C-Mod FIR Polarimeter*

Levitated Dipole Experiment

Development of the frequency scanning reflectometry for the registration of Alfvén wave resonances in the TCABR tokamak

Reflectometry for density and fluctuation measurement on EAST

TIME/SPACE-PROBING INTERFEROMETER FOR PLASMA DIAGNOSTICS

Lower Hybrid. Ron Parker Alcator C-Mod PAC Meeting January January 2006 Alcator C-Mod PAC Meeting 1

Relative Frequency Calibration for Fast Frequency Sweep Microwave Reflectometry

Full-wave feasibility study of magnetic diagnostic based on O-X mode conversion and oblique reflectometry imaging

Dust Measurements With The DIII-D Thomson system

Poloidal Transport Asymmetries, Edge Plasma Flows and Toroidal Rotation in Alcator C-Mod

Measurements of Mode Converted ICRF Waves with Phase Contrast Imaging in Alcator C-Mod

Improved core transport triggered by off-axis ECRH switch-off on the HL-2A tokamak

External Stimulation of Edge Modes

Reflectometry for density and fluctuation measurement on EAST

Density Fluctuation Measurements Using a Frequency Hopping Reflectometer in JT-60U

Initial Data of Digital Correlation ECE with a Giga Hertz Sampling Digitizer

Electron density profile reconstruction on the TCABR sweeping reflectometer

DESCRIPTION OF THE OPERATION AND CALIBRATION OF THE MILLIMETER I/Q PHASE BRIDGE-INTERFEROMETER

High Temporal Resolution Polarimetry on the MST Reversed Field Pinch

P. Koert, P. MacGibbon, R. Vieira, D. Terry, R.Leccacorvi, J. Doody, W. Beck. October 2008

Imaging EBW emission on MAST to diagnose the plasma edge

GA A22338 A HYBRID DIGITAL-ANALOG LONG PULSE INTEGRATOR

A NEW MULTI-POINT, MULTI-PULSE THOMSON SCATTERING SYSTEM FOR THE MST RFP

VARIABLE REPETITION RATE THOMSON SCATTERING SYSTEM FOR THE GLOBUS-M TOKAMAK

Investigating High Frequency Magnetic Activity During Local Helicity Injection on the PEGASUS Toroidal Experiment

Performance of the Prototype NLC RF Phase and Timing Distribution System *

Status of C-Mod Diagnostics. Presented by Jim Irby For the C-Mod Group

Advanced Tokamak Program and Lower Hybrid Experiment. Ron Parker MIT Plasma Science and Fusion Center

J.A. Casey and J.H. Irby. M.I.T. Plasma Fusion Center

2D Physical optics simulation of fluctuation reflectometry

ICRF mode conversion in three-ion species heating experiment and in flow drive experiment on the Alcator C- Mod tokamak

Initial Active MHD Spectroscopy Experiments Exciting Stable Alfvén Eigenmodes in Alcator C-Mod

Development of Collective Thomson Scattering System Using the Gyrotrons of Sub-Tera Hz Region

Alcator C-Mod Ion Cyclotron Antenna Performance

Magnetic Reconnection and Ion Flows During Point Source Helicity Injection on the Pegasus Toroidal Experiment

Ion Heating Arising from the Damping of Short Wavelength Fluctuations at the Edge of a Helicon Plasma Source

Absolute distance interferometer in LaserTracer geometry

Structure and Characteristics of the Quasi-Coherent Mode

Sideband Smear: Sideband Separation with the ALMA 2SB and DSB Total Power Receivers

Holography Transmitter Design Bill Shillue 2000-Oct-03

Modern radio techniques

Heterodyne Sweeping Radiometer

USER OPERATION AND MAINTENANCE MANUAL

EVLA Memo 105. Phase coherence of the EVLA radio telescope

History of Velocimetry Technology

Observation of quasi-coherent edge fluctuations in Ohmic plasmas on NSTX

On the difference between phase and amplitude behaviours: dependencies on the radiation pattern and on the turbulence level. S.

The Coaxial Multipactor Experiment (CMX): A facility for investigating multipactor discharges

ICRF antenna matching systems with ferrite tuners for the Alcator C-Mod tokamak

Paul Scherrer Institute Pierre-André Duperrex. On-line calibration schemes for RF-based beam diagnostics

Measurements of edge density profile modifications during IBW on TFTR

PHASE TO AMPLITUDE MODULATION CONVERSION USING BRILLOUIN SELECTIVE SIDEBAND AMPLIFICATION. Steve Yao

Measurement of Mode Converted ICRF Waves with Phase Contrast Imaging and Comparison with Full-wave Simulations on Alcator C-Mod

Development of microwave imaging reflectometry at NIFS

The Compact Toroidal Hybrid A university scale fusion experiment. Greg Hartwell

Optical phase-coherent link between an optical atomic clock. and 1550 nm mode-locked lasers

Field-Aligned ICRF Antenna Characterization and Performance in Alcator C-Mod*

DECEMBER 1964 NUMBER OF COPIES: 75

Detection and application of Doppler and motional Stark features in the DNB emission spectrum in the high magnetic field of the Alcator C-Mod tokamak

Terahertz radar imaging for standoff personnel screening

HF Receivers, Part 2

- RF Master-Reference Update (F.Ludwig, H.Weddig - DESY, K.Czuba - TU Warsaw) - Beam Stability Update (C.Gerth, F.Ludwig, G.

Co-current toroidal rotation driven and turbulent stresses with. resonant magnetic perturbations in the edge plasmas of the J-TEXT.

3.10 Lower Hybrid Current Drive (LHCD) System

Physical model of the LISA Pathfinder differential acceleration measurement and its application to LISA. LISA Symposium 5 September 2016, Zurich

Facilities and Upgrades PAC Presented by Jim Irby for the C-Mod Group

Nanometer-level repeatable metrology using the Nanoruler

SA210-Series Scanning Fabry Perot Interferometer

Frequency Stabilized Lasers for LIDAR 6/29/2016 Mark Notcutt and SLS Team Stable Laser Systems Boulder CO

Field Aligned ICRF Antenna Design for EAST *

325 to 500 GHz Vector Network Analyzer System

200-GHz 8-µs LFM Optical Waveform Generation for High- Resolution Coherent Imaging

System Upgrades to the DIII-D Facility

Diode Laser Control Electronics. Diode Laser Locking and Linewidth Narrowing. Rudolf Neuhaus, Ph.D. TOPTICA Photonics AG

Simple System for Active Frequency Stabilization of a Diode Laser in an External Cavity

ABSTRACT. Supported by U.S. DoE grant No. DE-FG02-96ER54375

PSFC/JA RF-Plasma Edge Interactions and Their Impact on ICRF Antenna Performance in Alcator C-Mod

Low Noise, High Power DFB Laser Part #LN Pxx

Pedestal Turbulence Dynamics in ELMing and ELM-free H-mode Plasmas

60 GHz RX. Waveguide Receiver Module. Features. Applications. Data Sheet V60RXWG3. VubIQ, Inc

Optical Vernier Technique for Measuring the Lengths of LIGO Fabry-Perot Resonators

High Density LHRF Experiments in Alcator C-Mod and Implications for Reactor Scale Devices

Transcription:

PSFC/JA-98-29 Upgrade of Reflectometry Profile and Fluctuation Measurements in Alcator C-Mod Y. Lin, J. Irby, P. Stek', I.H. Hutchinson, J. Snipes, R. Nazikian 2, M. McCarthy 2 ' 3 October 1998 Plasma Science and Fusion Center Massachusetts Institute of Technology Cambridge, MA 02139 'Present address: Jet Propulsion Laboratory, Pasadena, CA 91109. 2 Princeton Plasma Physics Laboratory, P.O. Box 451, Princeton, NJ 08543. 3 Present address: Los Alamos National Laboratory, Los Alamos, NM 87545. To be published in Review Scientific Instruments. This work was supported in part by the U. S. Department of Energy Contract No. DE- AC02-78ET51013. Reproduction, translation, publication, use and disposal, in whole or in part by or for the United States government is permitted.

Upgrade of Reflectometry Profile and Fluctuation Measurements in Alcator C-Mod Y. Lin, J. Irby, P. Stek* I. Hutchinson, J. Snipes Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 R. Nazikian, M. McCarthyt Princeton Plasma Physics Laboratory, P. 0. Box 451, Princeton, NJ 08543 Abstract This paper reports on the upgrade of the reflectometry profile and fluctuation measurements in Alcator C-Mod. The reflectometer consists of five amplitude modulated 0-mode millimeter-wave channels operating between 50 GHz and 110 GHz. The system provides the electron density profile for densities up to 1.5 x 1020 m- 3. An upgrade has been implemented to improve the reliability of the system, eliminate 27r ambiguities in the group delay measurement, and enhance the fluctuation measurements. An upgrade of the 88 GHz channel has been installed, which allows fluctuations on both the upper and lower side-band signals to be measured independently with high resolution. Some preliminary fluctuation and density profile results are discussed. *Present address: Jet Propulsion Laboratory, Pasadena, CA 91109 tpresent address: LANL H827, Los Alamos, NM 87545 1

I. Introduction The Alcator C-Mod tokamak is a high field (Bo = 5-8 T), high density (ne > 1.0 x 1020 M- 3 ), compact machine (Ro = 0.67 m, a = 0.23 m). Proper H-mode pedestal studies [1] will require a high resolution edge density profile measurement. On Alcator C-Mod reflectometry currently provides our best edge density profile data, though without the spatial resolution to fully resolve the pedestal region. However, the reflectometer system described here does provide reliable information during L-mode operation, and a very useful upper bound on H-mode density scalelengths. The study of edge density fluctuations and turbulence in different H-mode plasmas has also become important, especially in Enhanced D, H-mode [2], a type of H-mode first observed in Alcator C-Mod. A high resolution reflectometry fluctuation measurement will provide more information about plasma edge phenomena. The reflectometer in the Alcator C-Mod tokamak is an amplitude modulated (AM) reflectometer working in O-mode [3]. It consists of five channels with center frequencies of 50, 60, 75, 88, and 110 GHz. The measured densities range from 0.31 x 1020 m- 3 to 1.50 x 1020 M 3. AM reflectometry was originally proposed to improve the temporal resolution of the reflectometry system [4] [5] [6]. An AM reflectometer continuously measures the group delay to the critical surface on a time scale fast compared to changing plasma conditions. The modulation frequency should be chosen so small that less than one fringe needs to be tracked during the time of interest and the two critical layers are in the fluctuation correlation length (See the review article [7]). However, in the existing system, too high a frequency was initially chosen, and there were multiple fringe jumps in the phase measurement. Signal loss due to the frequency drift of the mm-wave sources was also a problem. Both issues have been solved in the upgrade. The usual differential phase measuring scheme for AM reflectometry, i.e., measuring the phase difference between the upper (USB) and lower (LSB) side-bands of the AM waves, reduces fluctuation sensitivity compared to the base-band technique. The differential phase scheme effectively subtracts correlated fluctuations found in the USB and LSB signals. In order to study density fluctuations at the critical surface, the USB and LSB signals should be separated and measured independently. A prototype of such a system at 88 GHz has been developed and installed. In Section II, the upgrade of the reflectometer is presented. The upgrade includes stabilizing the frequency drift of the mm-wave sources, reducing the AM modulation frequency, and installing a fluctuation measurement channel. Some preliminary results are presented in Section III. More issues about the 2

reflectometer are discussed in Section IV. II. Reflectometer Upgrades A. Frequency Stabilization of Gunn Oscillators The group delay detecting system includes narrow band-width filters and limiting amplifiers. This measuring scheme restricts the allowable frequency drift of the mm-wave sources (Gunn oscillators) to be less than ±5 MHz. The frequency of a Gunn oscillator depends on the bias voltage, varactor voltage, and temperature. Since all applied voltages are well controlled, frequency drift is mainly due to a change in ambient temperature. The drift can be as high as 10 MHz/ 0 C for Gunn oscillators in the frequency range of 50-110 GHz, which makes the system unreliable even under small variations in room temperature. A method that controls the temperature and stabilizes the Gunn oscillators frequencies has been implemented (Similar schemes used in reflectometry for fusion plasma have been reported, for example, [8]). Fig. 1 shows the method used. A thermo-electric chip (TEC) is mounted onto an aluminum block, which is in thermal contact with the Gunn oscillator. The signal of the temperature sensor in the aluminum block is used to control the TEC, which can heat as well as cool the Gunn oscillator. The feed-back temperature control system controls the temperature of the Gunn oscillator to within A0.1 0 C, and stabilizes the frequency to within ±2 MHz during a run day. This control range is sufficient to keep all IF signals within allowable passbands. B. Profile Measurement Upgrade For 0-mode reflectometry, the density profile is obtained by an Abel inversion of group delays [9]: c lafd Rc(fo) = R o -ur(f) 27r2 f 0 (f 2 (1) - f2)1 where R,(fo) is the critical surface position for the wave with frequency fo, and Rout is the outmost plasma edge (ne(rout) = 0). As shown in Eq. (1), in order to obtain R,(fo), one needs to measure the group delays, 7(f), of all frequencies f < fo. The AM profile measurement system, as shown in Fig. 2, measures the phase difference (AD = 0,, - 0) of the upper side-band (USB), f + Af, and lower side-band (LSB), f - Af, and determines the group delay r = 1" 3

The modulation frequency, Af, must be chosen carefully [7]. It cannot be too large or multiple fringes will have to be followed; but it cannot be so small as to seriously limit spatial resolution. The modulation frequency was initially set at 500 MHz for high spatial resolution. However, because of the short beat-wave wavelength, the measured AzI had several fringe jumps and tracking the phase could be difficult without manual intervention in the analysis process. A lower modulation frequency of 132.5 MHz is now used and has solves this problem. The use of I/Q (sin/cos) detectors provided more than adequate resolution (± 30) for density profile measurements. Limiting amplifiers in the phase detecting system also reduce the amplitude effects in the phase measurement. The absolute group delay calibration obtained by assuming a mirror reflection from the vacuum vessel inner wall was found to be inadequate, possibly due to changes in coupling of the reflected waves into the horns, spurious reflections and over-moded waveguides. Instead, a combined profile derived from the two-color interferometer (TCI), Thomson scattering, and the fast scanning Langmuir probe are used to calibrate the reflectometer. The density profile below the lowest density measured by the reflectometer, 0.31 x 1020 m-3, which is usually outside of the last closed flux surface (LCFS), can only be provided by the Langmuir probe. By assuming the reflectometer profile to be the same as the interpolated profile of the TCI, Thomson scattering, and the probe during the L-mode portion of the discharge, some offset corrections can be determined for group delays (Fig. 3). C. Fluctuation Measurement Upgrade A prototype system at 88 GHz (cutoff density n, = 0.96 x 1020 m- 3 ) designed to study fluctuation specifically has now been installed. As shown in Fig. 4, the USB and LSB signals are separated by introducing a reference signal that is the mixed output of the two Gunn oscillators. The phases of the USB and LSB signals are measured independently. No limiting amplifier is used, thus both amplitude and phase fluctuations of the reflected signals can be studied. The new system measures the phase change of the baseband signal as do many other reflectometers, for which some models have been developed to explain fluctuations. This system also allows correlations between the USB and LSB to be studied. III. Results A typical profile evolution during the L-mode to H-mode (L-H) transition 4

is shown in Fig. 5. The edge density profile steepens in less than 5 ms. The profile is obtained using the calibration method described in Section II (B). While the spatial error is still large due to calibration inaccuracy, the temporal resolution is adequate. The reflectometer easily follows fast changes of the density profile. Some preliminary results from the upgraded fluctuation channel are also presented. Coherent frequencies are observed in H-mode phase, especially in Enhanced D, (EDA) H-mode. Fig. 6 shows a case when the plasma undergoes H-mode to L-mode and back to H-mode transitions. Clear coherent frequencies are observed in the complex FFT power spectra, IS(f)l2, during the H-mode phase. No coherent mode has been observed in L-mode. In Fig. 7, coherent frequencies clearly evident in EDA H-mode broaden and vanish when the plasma enters an ELM free period. Coherent modes are usually in the frequencies range of 100-150 khz. As shown in Fig. 7, they are also modulated by sawtooth oscillations in EDA H-mode. The value of the center frequency is closely correlated to D, signal level. The spectra are obtained by FFT analysis on the complex signal as has been discussed previously [10] [11]: S(f) = E(t) [cos <b(t) + i sin 4D(t)] e-i 2 7 t dt (2) where E(t) cos P(t) and E(t) sin 4(t) are the sin and cos outputs of the I/Q detector respectively. IV. Discussion As pointed out in [7] [12], etc., AM reflectomery can have difficulties separating the primary return from multiple reflections from the vacuum wall or other targets due to its limited range resolution. We believe these effects only affect the initial wall calibration since in the C-Mod design the plasma return signal should strongly dominate. Statements to the effect that multiple reflections are not detectable in AM systems assume static conditions. Any motion of the spurious targets or the plasma make them painfully obvious. Scans of the plasma position together with comparisons to probe, interferometer, and Thomson scattering data must be used to sort out these issues. Some compensating methods, such as adding mm-wave absorpent material on the nearby vacuum wall and sweeping the modulation frequency, which can average out most spurious signals, are also being considered. Improvements to the waveguide structure is also being considered in order to reduce 5

sensitivity to both mechanical vibrations and coupling effects at the horns. 1-D models, 2-D models, models with scattering effects, and models considering specific critical surface structures have been developed to explain fluctuations measured by reflectometry (Ref. discussions in [11]). However, due to the complicated features of the problem, the physical meaning of fluctuations is still an open issue. How to express reflectometry fluctuations in terms of fundamental plasma parameters, such as the density fluctuation level and k-spectra, and how to relate the reflectometry fluctuations with other fluctuation diagnostics in Alcator C-Mod are still under study. V. Summary An upgrade on the reflectometer in Alcator C-Mod has been implemented. The upgrade has improved the reliability of the system, new high sensitivity fluctuation electronics has been added, frequency drift in the mm-wave sources has been stabilized, and 27r phase ambiguities in the group delay measurement have been eliminated. With improved calibration techniques, the Alcator C-Mod reflectometer should provide reliable density profile information during the next run campaign. Acknowledgements The authors would like to thank Jim Reardon for valuable discussions on profile calibration. This work was supported by U.S. DOE Contract No. DE-AC02-78ET51013 and DE-AC02-76-CHO-3073. 6

References [1] A. E. Hubbard, R. L. Boivin, R. S. Granetz, M. Greenwald, I. H. Hutchinson, J. H. Irby, Y. In, J. Kesner, B. LaBombard, Y. Lin, J. E. Rice, T. S. Pedersen, J. A. Snipes, P. C. Stek, Y. Takase, S. M. Wolfe, S. Wukitch, Phys. Plasmas, 5, 1744 (1998). [2] Y. Takase, R. L. Boivin, F. Bombarda, P. T. Bonoli, C. Christensen, C. Fiore, D. Garnier, J. A. Goetz, S. N. Golovato, R. Granetz, M. Greenwald, S. F. Horne, A. Hubbard, I. H. Hutchinson, J. Irby, B. LaBombard, B. Lipschultz, E. Marmar, M. May, A. Mazurenko, G. McCracken, P. O'shea, M. Porkolab, J. Reardon, J. Rice, C. Rost, J. Schachter, J. A. Snipes, P. Stek, J. Terry, R. Watterson, B. Welch, and S. Wolfe, Phys. Plasmas, 4 (5), 1647 (1997). [3] P. Stek, Ph. D. thesis, Reflectometry Measurements on Alcator C-Mod, Massachusetts Institute of Technology, March, 1997. [4] V. Vershkov, V. Zhuravlev, Sov. Phys.-Tech. Phys., 32, 523 (1987). [5] J. Sanchez, B. Branas, T. Estrada, E. de la Luna, and V. Zhuralev Rev. Sci. Instrum., 63, 4654, (1992). [6] G. R. Hanson, J. B. Wilgen, T. S. Bigelow, I. Collazo, and C. E. Thomas, Rev. Sci. Instrum., 63, 4658, (1992). [7] C. Laviron, A. J. H. Donn6, M. E. Manso, J. Sanchez, Plasma Phys. Control. Fusion, 38, 905 (1996). [8] K. W. Kim, E. J. Doyle, T. L. Rhodes, W. A. Peebles, C. L. Retig, and N. C. Luhmann, Jr., Rev. Sci. Instrum., 68, 466 (1997). [9] F. Simonet, Rev. Sci. Instrum. 56 (5), 664 (1985). [10] K. Shinohara, S. Shiraiwa, K. Hoshino, Y. Miura, K. Hanada, H. Toyama and JFT-2M group, Jpn. J. Appl. Phys., 36, 7367 (1997). [11] T. Rhodes, W. Peebles, E. Doyle, P. Pribyl, M. Gilmore, R. Moyer and R. Lehmer, Plasma Phys. Control. Fusion, 40, 493 (1998). [12] E. Doyle et al, in Diagnostics for Experimental Thermonuclear Fusion Reactors, P. E. Stott et al, eds., (Plenum Press, New York, 1996). 7

Figure Captions: Figure 1. Gunn Oscillator Frequency Stabilization. Depending on the level of temperature sensor signal, the thermo-electric chip (TEC) heats or cools the aluminum block, which is in thermal-contact with the Gunn oscillator. The temperature is controlled, thus the frequency is stabilized. Figure 2. Layout of Profile Measurement System. The group delay is obtained by measuring the phase difference between the upper and lower side-bands. Limiting amplifiers reduce the amplitude effects in the phase measurement. The three waves, 132.5 MHz, 235 MHz, and 30 MHz, are derived from a single wave source. Figure 3. Density Calibration. At a time point (in L-mode) when probe data are available, a combined profile derived from the interferometer (TCI), Thomson scattering, and the probe provides the calibration for reflectometer data. Corrections to the group delays are determined by assuming that the reflectometer produces the same profile as the combined profile. Figure 4. Layout of the Fluctuation Measurement Channel. A reference signal, 515 MHz, derived by mixing signals from the two Gunn oscillators is used to separate the upper and lower side-bands. The phases of the sidebands are measured independently (Only the USB is shown in the figure). The waves of 132.5 MHz and 500 MHz are derived from a single wave source. Figure 5. Profile Evolution during L-H Transition. The edge profile measured by the reflectometer steepens rapidly in the L-H transition. The relative changes of positions have errors of less than 0.5 cm while the absolute positions have errors of less than 1 cm. Figure 6. Fluctuation Power Spectra IS(f)1 2 in L-H-L Transitions. Coherent frequencies in the 100-150 khz range are observed during H-mode phases, but no such coherent frequency occurs during L-mode operation. Figure 7. Fluctuation Power Spectra IS(f)12 in Different H-modes. Coherent frequencies clearly evident in Enhanced Da (EDA) H-mode broaden and vanish when the plasma enters an ELM free period. In EDA H-mode, The center frequency is modulated by sawtooth oscillations and correlates with D, signal level. 8

Insulation Sensr Gunn Oscillator Wave Guide Aluminum Block TEC Power Rack Mount (Heat Sink) Figure 1: fo = 50, 60, 75, 110 GHz Modulation Gunn OSC 1 132.5MHz fo < ---- L Gunn OSC 2 Up-ConvertorA fo +397.5 MHz Mixer S L R M A Pre-mp 530 & 265 MHz R 530 MHz Limiting BPF Amp L 600 MHz R Mixer 235 MHz Mxr 30MHz Reference Ito 30 MHz BPF Limiting Amp camac Figure 2: 9

3.0 Shot 980213027 2.5 - t=0.4rs Limite r 2.0 - oo LCFS 1.5- SS S1.0 TCI o Thomson + Probe A Reflectometer - Combined 0.0... 0.70 0.75 0.80 0.85 0.90 R (m) - Figure 3: 10

GuR OSC 1 88 GHz L. (AA- Modulation 132.5 MHz R Up-Convertor p 515 MHz REF Mixe L A Gunn OSC 2 88.515 GHz LMixer LA Pre-Amp Soo MHz Mixer R L Mixe 132.S MHZ. 600 MHz R Soo MHz ixrl 1A 500 MHz SN A Reference va Cs C M Figure 4: 11

1.5 Shot 980213027 A t=0.638s L-mode 3 t=0.643s H-mode 0 1.0 0.5 n n LCFS Limiter 0.84 0.86 0.88 0.90 0.92 0.94 R (m) Figure 5: N 200 150 100 Shot 980218025 103 102 50 10I 1U 0.8 0.6 0.4 -.-.n(r=0). - -- --- 0.2 0.0 H-mode L-mode H-mode 0.72 0.74 0.76 0.78 Time(s) 0.80 0.82 Figure 6: 12

N 200 150 100 Shot 980218020 103 102 50 1.8 0.8 101 1'U 0.6 0.4 0.2 0.0 0.72 0.74 0.76 0.78 0.80 0.82 Time(s) Figure 7: 13