THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

Similar documents
Dr. Magda Rau Eye Clinic Cham, Germany

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

Improving Lifestyle Vision. with Small Aperture Optics

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK.

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

EXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange

Refractive Power / Corneal Analyzer. OPD-Scan III

Unique Aberration-Free IOL: A Vision that Patients

Clinical Evaluation 3-month Follow-up Report

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

ROTATIONAL STABILITY MAKES THE DIFFERENCE

Advanced Technology IOLs

Long-term quality of vision is what every patient expects

Customized intraocular lenses

Subjective refraction OPTICS OF HUMAN EYE & REFRACTIVE ERRORS

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

PreciSAL Preloaded Lens System

Principles and clinical applications of ray-tracing aberrometry (Part II)

Raise your expectations. Deliver theirs.

Treatment of Presbyopia during Crystalline Lens Surgery A Review

Evolution of Diffractive Multifocal Intraocular Lenses

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

The Dysphotopsia Mystery. John J. Bussa, M.D.

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

Technicians & Nurses Program

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

FOR PRECISE ASTIGMATISM CORRECTION.

Refractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens

Contents. Corneal Markers, Scleral Depressors

case report Scleral lens fit based on OCT data

GETTING STARTED WITH DMEK

Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

Optical Path Difference Scanning System OPD-Scan II ARK-10000

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

Clinical Evaluation 3-month Follow-up Report

AHEAD Superior technology, thoughtfully designed with you in mind for an intelligent approach to cataract surgery.

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

Sutureless Trocar-Cannula Based Transconjunctival Flanged Intrascleral Intraocular Lens Fixation

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects

Ocular Scatter. Rayleigh Scattering

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision

Forget Most Everything! The Surgical Management of Presbyopia 2/23/2016. Refraction vs. Diffraction. Presbyopic IOL s Patient Expectations

Accommodating IOL s History and Clinical Management

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses

Intraocular lens Difficulties

Subjective refraction

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

Clinical Update for Presbyopic Lens Options

Sulcoflex Pseudophakic Supplementary IOLs


IOL Review and FLACS Update

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

COMPARISON OF THE MEDICONTUR 860FAB

Fitting Manual Use with kerasofttraining.com

DESIGNED FOR SUCCESS...GUARANTEED TO FIT

LASIK & Refractive Surgery

WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION. Cataract treatment

IOL Predictions for the Coming Year

Cataract Information. victoriaeye.com

Vision for What They Love.

4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston

Optical Zone Diameters for Photorefractive Corneal Surgery

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL

Roadmap to presbyopic success

By Dr. Abdelaziz Hussein

Wavefront Aberrations in Eyes With Acrysof Monofocal Intraocular Lenses

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

Multifocal and Accommodative

KERATOCONUS. In the most advances cases, the corneal deformation can be easy observed fig. 1. Fig. 1

Optical Connection, Inc. and Ophthonix, Inc.

The procedure was nearly complete. I was

Evolution of the Cataract Patient

OCULUS Pentacam AXL Always an Axial Length Ahead

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE

Biology 70 Slides for Lecture 1 Fall 2007

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT

Advances in the design and

PROFESSIONAL FITTING GUIDE

Modified Peripheral Iris Fixation of a Foldable Intraocular Lens Following Phacoemulsification

The Miracle of Pi in Eye. Rajesh Khanna, MD

Fitting Manual Use with

Diffractive Optics. Multifocal Lenses. Correction of Pseudophakic Presbyopia with Multifocal IOLs. Basic Designs

Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome

Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes

Transcription:

XtraFocus

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES. CONTENT Based on the well-established principle of pinhole optics, this intraocular implant represents an innovative alternative for the ophthalmic surgeon. The following pages will provide detailed information required for safe and effective use of the XtraFocus Pinhole Implant. OVERVIEW... 05 TECHNICAL SPECIFICATIONS... 07 INDICATIONS... 09 PREOPERATIVE EVALUATION... 10 SURGICAL PROCEDURE... 13 POSTOPERATIVE FOLLOW-UP... 15 FREQUENTLY ASKED QUESTIONS... 18 LITERATURE... 21 VIDEO GALLERY... 23 Camera Obscura, Perdika (Greece)

OVERVIEW The XtraFocus Pinhole Implant is a pinhole intraocular implant. It has a 6.0 mm occlusive portion with a 1.3 mm pinhole aperture, with no dioptric power. It was conceived for the treatment of irregular corneal astigmatism with additional secondary indications. The pinhole aperture is able to effectively minimize the impact of corneal aberrations on the image quality. Dr. Claudio Trindade With two angulated open-loop haptics, it is designed to be implanted in the cilliary sulcus of pseudophakic eyes, in a piggyback configuration. Attention: The XtraFocus should not be implanted in phakic patients. 5 5

TECHNICAL SPECIFICATIONS TOTAL DIAMETER PINHOLE DIAMETER OPTIC DIAMETER POSITION HAPTIC MATERIAL 14.0 mm 1.3 mm 6.0 mm (concave-convex / no refractive power) Sulcus 2 Open-Loop 14 (250 micron) BLACK Hydrophobic Acrylic WATER CONTENT < 0.5 % INJECTOR (RECOMMENDATIONS) Alcon Monarch III with D cartridge Medicel VISCOJECT TM -BIO 2.2 FOUR SPECIFIC FEATURES TO PREVENT UVEITIS-GLAUCOMA-HYPHEMA SYNDROME (UGH) larger overall diameter (14.0 mm) 14 angulated haptics thin haptics (250 micron) rounded and polished edges of haptics and occlusive portion 7

INDICATIONS The main indication for the XtraFocus Pinhole Implant is the treatment of irregular corneal astigmatism (ICA). This includes Keratoconus Pellucid Marginal Degeneration Post-Radial Keratotomy ICA Post-Penetrating Keratoplasty ICA Post-LASIK Ectasia Traumatic corneal laceration Secondary indications are Near Vision Enhancement in Monofocal Pseudophakia (Depth of Focus Extension) Reduction of Dysphotopsias in Multifocal Pseudophakia (Halos and Glare) 9

PREOPERATIVE EVALUATION The preoperative evaluation is simple and does not 2. CORNEAL TOPOGRAPHY 4. REFRACTION PREOPERATIVE RETINAL EVALUATION require any special equipment. However, some important tests should be performed. The indication is based on FOUR main parameters: 1. PINHOLE ACUITY TEST Consider a good candidate if there is a solid and reliable improvement when the pinhole is placed on top of the best refraction. If the patient requires excessive time and effort to achieve improvement during the test, the XtraFocus implantation might not render a good visual result. This is usually observed in extremely irregular corneas. Avoid extremely irregular corneas, such as Keratoconus with K readings above 60.0 D Radial Keratotomy with multiple intersecting incisions and K readings below 28.0 D. The clinical benefits of the XtraFocus are limited by the amount of high order aberration. Patients with severe topographic irregularity and / or central corneal opacities may not achieve sufficient improvement in visual acuity with this treatment. In those cases, other corneal treatments (including a corneal graft) may be necessary. 3. PUPILOMETRY Consider a good candidate if the pupil diameter is Consider a good candidate someone with a moderate myopic refraction (approx. - 2.0 D). This will result in a very solid near vision with reasonable distance vision, which can be improved with glasses post-operatively. Although subjective refraction is challenging in cases of irregular corneal astigmatism, this is a very important point to be considered. If the implantation of the XtraFocus is being considered during cataract surgery, a - 2.0 D target is advisable. Implantation of the XtraFocus Pinhole Implant makes fundus examination more difficult. Therefore, it is mandatory to perform a thorough posterior segment examination, including binocular indirect ophthalmoscopy with scleral indentation, before the implantation of the device. Any retinal pathology should be treated before implantation and risk factors for retinal disease (especially those conditions that affect the peripheral retina) should be considered in the preoperative evaluation. If any vitreoretinal treatment is needed after implantation, the device would have to be explanted. Even with a favourable pinhole acuity test, central corneal opacities (corneal dystrophies, scars, severe haze, etc.) represent a relative contraindication for this treatment. 3.0 mm or larger in mesopic conditions. The larger the pupil, the greater the benefit of implantation. See the postoperative follow-up section for more detailed information. 10 11

SURGICAL PROCEDURE Routine steps for posterior chamber IOL implantation, through a 2.2 mm corneal incision. The XtraFocus Pinhole Implant can be implanted with most commercially available IOL delivery systems. The device should not be implanted upside down. To ensure proper orientation, the leading haptic should be directed to the left during implantation. Care should be taken to achieve proper centration of the intraocular implant. A subtle decentration towards the nasal portion of the pupillary area is advisable. Rotation of the implant may help achieving the targeted position. In case of primary piggyback implantation (concomitant with cataract surgery) it is advisable to remove OVD from the capsular bag after in-the-bag IOL implantation, to avoid unintentional placement of the XtraFocus inside the capsular bag. There is no need to perform peripheral iridectomy, since the pinhole aperture allows for adequate aqueous flow. 13

POSTOPERATIVE FOLLOW-UP A conventional cataract surgery follow-up regimen should be adopted. A few important details should be observed: AUTOREFRACTION Autorefraction readings are not reliable after implantation of the XtraFocus. A false hyperopic shift is observed after implantation. Since the black material of the XtraFocus is transparent to infrared light (see page 17) the infrared light emitted by the auto refractor is affected by the negative meniscus shape of the XtraFocus, generating a false hyperopic shift. This reading should be ignored. SUBJECTIVE REFRACTION Because of the Depth of Focus Extension caused by the XtraFocus implantation, changes during subjective refraction becomes less evident to the patient. Therefore larger dioptric steps (two or more diopters) should be considered by the examiner. 15

POSTOPERATIVE FOLLOW-UP RETINAL EXAMINATION The ability to perform binocular indirect ophthalmoscopy and some treatments (e.g. retinal photocoagulation, pars plana vitrectomy) is limited after implantation of the XtraFocus Implant. Image 1 To overcome this limitation the black acrylic has the unique feature of being transparent to infrared light (images 1 and 2) Examination of the posterior segment is possible with Infrared-based imaging equipment such as OCTs and scanning laser ophthalmoscopes. With special lenses (scanning laser ophthalmoscope contact lens or a non-contact ultra-wide-field lens), the field of view can be expanded to 150 degrees (image 3). For wider examination of the peripheral retina a B-Mode Ultrasound may be necessary. Image 2 Image 3 16 17

FREQUENTLY ASKED QUESTIONS DO PATIENTS REPORT REDUCTION OF LUMINANCE? Because of the restriction of light entrance imposed by the pinhole aperture, a sensation of darkened vision may be reported after implantation. This finding may vary in intensity and is normlly well-tolerated. Patients with greater magnitude of corneal irregularity typically do not report this condition. Patients with normal corneas usually report this symptom with greater intensity. Mild visual effects associated with a XtraFocus Pinhole Implant may occur. These may include a perception of halos around lights under nighttime conditions. CAN YAG CAPSULOTOMY BE PERFORMED AFTER THE IMPLANTATION? It is absolutely possible to perform YAG capsulotomy after the implantation. It is even possible to extend the capsular opening beyond the margins of the pinhole by asking the patient to look sideways. However, in very irregular corneas it may be challenging to aim accurately because of light reflections, which can lead to some pits in the IOL. It is not recommended to perform a prophylactic capsulotomy, prior to implantation. DOES IT CAUSE VISUAL FIELD CONSTRICTION? No, as long as the XtraFocus Pinhole Implant is well-centered, it does not cause constriction of the visual field. This is because of the close proximity between the implant and the iris plane. However, it does cause a slight reduction in overall retinal sensitivity, which can be observed in automated perimetry. WHICH IOL TO CONSIDER WHEN PLANNING FOR XTRAFOCUS IMPLANTATION DURING CATARACT SURGERY? Any monofocal IOL can be used (spherical, aspherical, toric, non-toric). It is very important to plan for a refractive target of approximately - 2.0 D. This will result in a very solid near vision with reasonable distance vision, which can be improved with glasses postoperatively. HOW TO MANAGE CENTRATION? During surgery, a minor decentration towards the nasal portion of the pupillary area is advisable. A vertical orientation of the haptics is recommended, to allow for easier lateral adjustment of the XtraFocus. Rotation of the implant may help achieving the targeted position. As expected with any sulcus fixated implant, minor decentrations may occur over time, especially in larger eyes. Slight decentrations are usually asymptomatic. Larger decentrations may cause reduction in visual acuity. Rotation of the device under peribulbar block is advisable to restore proper position. Re-expansion of the anterior capsular rim, followed by optic capture of the XtraFocus will ensure a more secure position (depending on size and position of the capsulorhexis). WHEN SHOULD I CONSIDER A TORIC IOL WITH THE XTRAFOCUS? The pinhole aperture is able no minimize high order aberrations and low order aberrations, including astigmatism. However, this effect is limited to a certain extent. In cases of astigmatism of greater magnitude, presenting a more regular bow tie, a toric IOL might be an interesting option. This decision should be based on the pinhole acuity test, adding cylindrical correction on top of the pinhole. If there is significant improvement of visual acuity, a toric IOL may be considered. ARE THERE DIFFERENT VERSIONS AVAILABLE, WITH VARIED DIMENSIONS? No, there is only one version of the XtraFocus. With an overall diameter of 14.0 mm and flexible haptics, it was designed to adjust to various ciliary sulcus dimensions, ith a gentle pressure in the sulcus. CAN THE XTRAFOCUS BE IMPLANTED INSIDE THE CAPSULAR BAG? Yes. Although the XtraFocus Pinhole Implant was designed for sulcus implantation, it may also be implanted inside the capsular bag (with or without a primary IOL). A "solitary" in-the-bag implantation of the XtraFocus (without a primary IOL) may be considered in cases of keratoconus, when a near-plano IOL is suggested during IOL power calculation. IS IT AVAILABLE WITH DIOPTRIC POWER? No, the XtraFocus is a pinhole intraocular diaphragm, with no refractive power. 18 19

LITERATURE New pinhole sulcus implant for the correction of irregular corneal astigmatism Claudio C. Trindade, MD, Bruno C. Trindade, MD, Fernando C. Trindade, MD, PhD, Liliana Werner, MD, PhD, Robert Osher, MD, Marcony R. Santhiago, MD, PhD Journal Of Cataract Refractive Surgery, VOL 43, Issue 10, October 2017 Novel pinhole intraocular implant for the treatment of irregular corneal astigmatism and severe light sensitivity after penetrating keratoplasty Claudio L.C. Trindade, MD, Bruno L.C. Trindade, MD JCRS Online Case Reports, VOL 3, January 2015 Phacoemulsification with intraocular pinhole implantation associated with Descemet membrane endothelial keratoplasty to treat failed full-thickness graft with dense cataract Assessment of a novel pinhole supplementary implant for sulcus fixation in pseudophakic cadaver eyes Eye, October 2017 The Lowdown on High-Tech IOLs EyeNet, October 2017 New Intraocular Lenses EuroTimes, February 2018 Development of a pinhole implant: XtraFocus Claudio C. Trindade, MD Cataract and Refractive Surgery Today Europe, February 2016 A Small-Aperture intraocular diaphragm Claudio C. Trindade, MD Cataract and Refractive Surgery Today Europe, January 2015 Bruno Lovaglio Cançado Trindade, MD, PhD, Fernando Cançado Trindade, MD, PhD, Claudio Lovaglio Cançado Trindade, MD, Marcony Santhiago, MD, PhD Journal of Cataract and Refractive Surgery 21

VIDEO GALLERY Tiny Hero Against the Evil Axis ASCRS Film Festival Grand Prize 2017 XtraFocus Pinhole for Keratoconus XtraFocus Pinhole for Mydriasis and RK Irregular Astigmatism XtraFocus Pinhole for Keratoconus and Mydriasis XtraFocus Pinhole for Penetrating Ocular Trauma XtraFocus Pinhole for Irregular Astigmatism after RK XtraFocus Pinhole for Keratoconus You will find all listed videos on our website www.morcher.com 23

MORCHER GmbH Kapuzinerweg 12 70374 Stuttgart GERMANY Phone +49(0)711/95320-0 E-Mail info@morcher.com Fax +49(0)711/95320-80 Web www.morcher.com V2018-08 / BAR