Hang-TITE Rod Hanger Screws

Similar documents
Hollo Set Drop-In Anchors

POWER-Skru Large Diameter Concrete Screw

Elco Construction Products 1301 Kerr Drive Decorah, IA fax:

POWER-Drop Drop-In Anchors

Multi-Set II Drop-In Anchors

ALLIGATOR All-Purpose Anchors

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Peco Fasteners 3/8 Internal Plug Drop In 50 Per Jar 3/8-16 SMART DROP IN ANCHOR ZINC

PRODUCT INFORMATION. ASTM B633,SC1, Type III (Fe/Zn 5) Rod/Anchor Diameter

Large Diameter Tapcon

TOGGLER Specialty Anchors

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW

T3ss Gas Powered Tool

STRUCTURAL ATTACHMENTS

CMA-455 Suspended Ceiling-Tile Reinforcing Kit

Umbrella Inserts and Stubby Screens

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

Umbrella Inserts and Stubby Screens

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here)

HPH Series J-Hook Installation Instructions

Midwest Roadside Safety Facility

AUXILIARY FRAMING AND ACCESSORIES

Beam and Purlin Clamps Beam Clamps

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

MX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

SWAY BRACE PIPE ATTACHMENT FIG. 010

Instruction Sheet For: SCM-2

Powder Actuated Fasteners - Drive Pins

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

XL MAX. Suspension System Data Center Ceiling Solutions. Assembly and Installation Instructions

The All American Anchor is a positive drive positive setting anchor for use in all masonry materials / / /8 7 1/ /16

Letter of Transmittal/Submittal

Installation and Assembly: Ceiling mount for LCD screens up to 29"

YOUR ONE SOURCE FOR CONCRETE FASTENERS PRODUCT CATALOG. p f East 40th Street Cleveland, Ohio

Installation Instruction

ANCHORS SLEEVE ANCHORS BOLT DIAMETER

MSP-WRTIDSKY1 Light Weight Suspended Ceiling Kit for use with Island Display Skybox

FNW can handle all your hanger and fastener needs, all in one place. FNW products are sold exclusively at Ferguson.

Sigma Fasteners, Inc. Section 7

CONTENTS. Hammerscrews White Zinc Plated 2 Hammerscrews Stainless Steel A Nylon Frame Anchors Yellow Zinc Plated 3 Nylon Plug 3

The Quick, Economical Method to Secure Hurricane Protection

Copper Tubing Hangers Clevis Hangers. Copper Tubing Hangers

ULTRA SPACE SAVER Installation Instructions

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

CPVC-10. CPVC Pipe Hangers Straps To Support Your Piping

Precision Engineering & Reliability WIRE ROPE SUSPENSION SYSTEM

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Assembly Instructions for Model: VMPL3

PRODUCT INFORMATION 0.145/0.130" 100 5,

PRICE BOOK NO. 204S ORDERING INFORMATION

Installation & Assembly: Two Piece Suspended Ceiling Plate

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

DobyGrip Accessories. Wire with Loop. Wire with Closed M6 & *M8 Eye Bolt. Wire with Carabina

CSS Central Mount System

Approvals and Listings 3. Sammys for Wood 4. Sidewinder for Wood 5. Sammys Swivel Head for Wood 5. Sammys for Steel 6. Sidewinder for Steel 7

KOLO SHELTER Installation Instructions Parts List

Installation & Assembly: Suspended Ceiling Kit

METAL-TO-METAL FASTENERS QUIKDRILL METAL2METAL METAL2METAL HD. Value through the Roof.

MPA-9000 Universal Ceiling Projector Mount Kit

LENGTH IDENTIFICATION

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

Superstrut Stainless Steel Channels and Accessories

Fixings & Fastenings. Bright Zinc Plated, Galvanised & Stainless Steel. Lockinex. ea i, ea u i

The Saddle Rack. For Power And Communication Cables

Dimensions Mechanical and Performance Requirements. Drop-In Anchors Hollow Wall, Steel Regular Style Drive Style...

MISCELLANEOUS SIGN CONNECTION DETAILS TYPICAL ROUTE MARKER ASSEMBLIES SIGN TO POST MICHIGAN DEPARTMENT OF TRANSPORTATION

Independent Containment System (ICS)

Wire Mesh Cable Tray System for Channeling of Cable Wiring

Section Member. H (in.) WT. lb./ft. Pull Out Strength Slip Resistance Torque Size / Thread All Series

MULE-HIDE PRODUCTS CO., INC FASTENER GUIDELINES

Double Beam Freestanding Pergola Installation Guide

TABLE OF CONTENTS REQUIRED TOOLS

Midwest Roadside Safety Facility

ICC-ES Evaluation Report Reissued June 1, 2011 This report is subject to renewal in one year.

FASTENERS & ACCESSORIES

Wire Mesh Cable Tray System for Channeling of Cable Wiring

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

DYNABOLT PLUS ANCHORS DYNABOLT PLUS. Anchor Details. Installation Ramset Regions. Site Map. Home Page. Performance. Next Page. Date of Issue: 9/98

PURE GP. Adhesives GENERAL INFORMATION SECTION CONTENTS. Epoxy Injection Adhesive Anchoring System

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

POWDER-ACTUATED FASTENERS IN COLD-FORMED STEEL CONSTRUCTION

Index Pipe Hangers and Straps

Wedge Type Anchors. Trubolt. Wedge Anchor ADVANTAGES

Track Rack. * Track Racks are not lockable

SYW Industry Sdn. Bhd. Stud Anchor. Hexagon Nut / Flange Nut. U - Bolt (c/w 2 Nuts) Steel Band. 1 of 8

APPLICATION FOR A BUILDING PERMIT

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

Ultra Space Saver American Bicycle Security Company

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

NX7 SERIES 5-1/2 HANDRAIL

QLF215 INSTRUCTION MANUAL

Anchor type Base material Approvals Application. Lightweight concrete Aerated concrete. Uncracked concrete. Solid brick masonry

Fastener Type Chart. Fastener Categories. Sheet Metal Screws Fully threaded screws with a point for use in sheet metal. Abbreviated SMS.

Ceiling Mount - 32" to 60" - Single Installation Instructions

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?

BUILT BY AMERICA. CONNECTED WORLDWIDE.

ULT R A SPAC E SAV E R

DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

Transcription:

Description The Hang-TITE Rod Hanger Screw is a one-piece, internally threaded anchor designed for suspending threaded rod for applications like cable-tray, pipe hanging, fire protection, and electrical conduit. It can be installed in a variety of base materials like wood frame columns and beams, steel purlins, bar joists and beams, and concrete ceilings, beams and columns. The Hang-TITE screws made for steel and wood applications are also available in a side mount style. Socket driver tools are available for easy installation using a screw gun or hammer drill. Key Features & Benefits One-piece anchor design Screw portion of the anchor will not prematurely break away from the anchor head Universal socket can be used for all Steel and Wood Hang- TITE screws Horizontal (side) mount available for both Steel and Wood Hang-TITE screws Lower in-place cost when compared to lag screws, drop-in anchors, and beam clamps Rapid installation for overhead applications All Hang-TITE screws can be installed using a screw gun or hammer drill Wood - Vertical Wood - Horizontal Steel - Vertical Steel - Horizontal Concrete - Vertical USA ENGINEERED Applications Cable-Tray Suspended Ceilings HVAC Ductwork Strut channels Electrical Conduit Hanging pipe Sprinkler systems Specifications, Listings and Approvals Materials: Carbon steel with zinc plating Case hardened C1022 ASTM B633 Type III Internal Thread Range (UNC): 1/4", 3/8", 1/2" Wood 1/4", 3/8", 1/2" Steel 1/4", 3/8", 1/2" Concrete 1-203-87-2200 www.wejit.com Page 1 of 7

Installation Information Instructions Wood 1. Mount the Universal Steel & Wood Socket Drive (Part No. HTWSST) into the chuck of the drill. NOTE: Certain types of wood truss/wood joint require pre-drilling with a 1/8 diameter bit 2. Insert the head of the anchor into the socket driver. 3. Press the tip of the anchor against the wood surface [or press tip into pre-drilled hole, if needed]. 1 2 3 4 4. Install with a smooth, steady motion until the anchor is firmly seated against the wood.. Thread the appropriate diameter steel threaded rod or threaded bolt into the anchor. The threaded rod or bolt should fully engage the thread length of the anchor. (vertical installation) (horizontal installation) Instructions Steel 1. Mount the Universal Steel & Wood Socket Drive (Part No. HTWSST) into the chuck of the drill. 2. Insert the head of the anchor into the socket driver. 3. Press the tip of the anchor against the steel surface and install with a smooth, steady motion until the anchor is firmly seated against the steel. No pre-drilling is required. 1 2 3 4 4. Add the retainer nut [if needed].. Thread the appropriate diameter steel threaded rod or threaded bolt into the anchor. The threaded rod or bolt should fully engage the thread length of the anchor. (vertical installation) (horizontal installation) Page 2 of 7 1-203-87-2200 www.wejit.com

Instructions Concrete 1. Use the correct size masonry drill and drill the hole at least one anchor diameter deeper than the calculated embedment depth. Clean the hole using a nylon brush and compressed air. 2. Select the appropriate size socket driver (Part No. HTCST14, HTCST38 or HTCST12) and mount it into the chuck of the drill. 3. Insert the head of the anchor into the socket driver. 1 2 3 4. Press tip into pre-drilled hole and install with a smooth, steady motion until the anchor is firmly seated against the concrete.. Thread the appropriate diameter steel threaded rod or threaded bolt into the anchor. The threaded rod or bolt should fully engage the thread length of the anchor. 4 Installation Data Wood Screw Steel Screw Screw Size Shank Length * Diameter Screw Thread Size Self Drilling Range Root Dia. Drill Speed (RPM) 1/4 Thread Forming Type 17 1/4 1/8 3/8 Thread Forming Type 17 1/4 1/8 1/4-20 #3 0.036 (20 gauge) 0.188 (3/16 ) 13/64 00-1,00 *If required #12-20 # 0.188 (3/16 ) 0.00 (1/2 ) 13/64 00-1,00 Steel & Wood Coupling Coupling Type Coupling Thread Size (UNC) Coupling Thread Depth Coupling Width Coupling Height 1/4 Vertical 1/4-20 3/8 /8 13/16 3/8 Vertical 3/8-16 3/8 /8 13/16 1/2 Vertical 1/2-13 3/8 /8 13/16 1/4 Horizontal 1/4-20 /8* /8 13/16 3/8 Horizontal 3/8-16 /8* /8 13/16 * Side Hang-TITE anchors have an open end internal threading. Concrete Dia. Overall Screw Shank Length Anchor Thread Length Coupling / Washer Height Washer O.D. Thread Size (UNC) Thread Depth Socket Driver Size 1/4 1/4 1-1/4 1-1/8 27/64 31/64 1/4-20 3/8 3/8 3/8 1/4 1-1/2 1-3/8 9/16 39/64 3/8-16 1/2 1/2 1/2 3/8 2-3/4 2-1/2 13/16 31/32 1/2-13 3/4 11/16 Page 3 of 7

Performance Data Wood: Ultimate and Allowable Tension Loads (lbs.) and Length Depth Allowable Ultimate Fir Pine Spruce Fir Pine Spruce 1/4 Vertical 1/4 x 1 1 170 160 160 680 640 640 3/8 Vertical 1/4 x 1 1 170 160 160 680 640 640 Vertical 1/4 x 2 2 37 37 37 100 100 100 Vertical 1/4 x 3 3 18 37 37 2070 100 100 Vertical 3/8 x 2-1/2 2-1/2 663 77 77 260 3100 3100 Horizontal 1/4 x 1 1 170 160 160 680 640 640 Horizontal 1/4 x 2 2 448 448 448 1790 1790 1790 Horizontal 3/8 x 2-1/2 2-1/2 368 390 33 1470 160 1410 1/2 Vertical 3/8 x 2-1/2 2-1/2 663 77 77 260 3100 3100 Steel: Allowable Tension Loads (lbs.) ASTM A 36 Steel (Beams) and ASTM A 72 Steel (Purlins) 1/4 3/8 1/2 and Minimum Steel Gauge (Thickness) Length 20 18 16 14 12 3/16" Vertical 1/4-20 x 1 (w/nut) 38 38 443 443 10 98 Vertical 1/4-20 x 1 103 18 248 288 383 79 Vertical 1/4-20 x 1 (w/nut) 38 38 443 443 10 98 Vertical 1/4-20 x 1-1/2 103 18 248 288 383 79 Vertical 12-20 x 1-1/2 (w/nut) 38 38 443 443 10 98 Horizontal 1/4-20 x 1-1/2 (w/nut) 38 38 443 443 10 98 Horizontal 1/4-20 x 1-1/2 103 18 248 288 383 490 Vertical 12-20 x 1-1/2 12 180 238 38 03 82 Vertical 12-20 x 1-1/2 (w/nut) 38 38 443 443 10 98 Steel: Ultimate Tension Loads (lbs.) ASTM A 36 Steel (Beams) and ASTM A 72 Steel (Purlins) 1/4 3/8 1/2 and Length Minimum Steel Gauge (Thickness) 20 18 16 14 12 3/16" Vertical 1/4-20 x 1 (w/nut) 140 140 1770 1770 2040 3830 Vertical 1/4-20 x 1 410 630 990 110 130 3180 Vertical 1/4-20 x 1 (w/nut) 140 140 1770 1770 2040 3830 Vertical 1/4-20 x 1-1/2 410 630 990 110 130 3180 Vertical 12-20 x 1-1/2 (w/nut) 140 140 1770 1770 2040 3830 Horizontal 1/4-20 x 1-1/2 (w/nut) 140 140 1770 1770 2040 3830 Horizontal 1/4-20 x 1-1/2 410 630 990 110 130 1960 Vertical 12-20 x 1-1/2 00 720 90 140 2010 3300 Vertical 12-20 x 1-1/2 (w/nut) 140 140 1770 1770 2040 3830 Page 4 of 7

Concrete: Allowable Loads (lbs.) Normal-Weight Concrete and Length Dia. Depth Allowable 2,000 psi 4,000 psi 6,000 psi Tension Shear Tension Shear Tension Shear 1/4 Vertical 1/4 x 1-1/4 1/4 1-1/4 34 40 48 60 1 63 3/8 Vertical 1/4 x 1-1/2 1/4 1-1/2 43 640 64 6 68 680 1/2 Vertical 3/8 x 2-3/4 3/8 2-3/4 132 130 100 17 214 180 Concrete: Ultimate Loads (lbs.) Normal-Weight Concrete and Length Dia. Depth Ultimate 2,000 psi 4,000 psi 6,000 psi Tension Shear Tension Shear Tension Shear 1/4 Vertical 1/4 x 1-1/4 1/4 1-1/4 1380 1800 1940 2420 2060 240 3/8 Vertical 1/4 x 1-1/2 1/4 1-1/2 1740 260 280 2620 2740 2720 1/2 Vertical 3/8 x 2-3/4 3/8 2-3/4 300 220 6000 6300 880 7400 Concrete: Ultimate and Allowable Loads (lbs.) Metal Deck Over Structural Lightweight Concrete 1,3 and Length Dia. Depth 20 Guage Steel over 3,000 psi Lightweight Concrete 2 Allowable Ultimate Tension Shear Tension Shear 1/4 Vertical 1/4 x 1-1/4 1/4 1-1/4 19 27 780 1100 3/8 Vertical 1/4 x 1-1/2 1/4 1-1/2 43 360 1740 1440 1/2 Vertical 3/8 x 2-3/4 3/8 2-3/4 90 720 3800 2880 1 Tabulated loads are for anchors installed with a min. flute edge distance of 1-1/2" 2 " wide deck tested 3 Allowable load capacities are calculated using an applied safety factor of 4:1 Concrete: Ultimate and Allowable Loads (lbs.) - Hollow Core Concrete Plank 1,2 and Length Dia. Depth Center of Web,000 psi Center of Core Allowable Ultimate Allowable Ultimate 1/4 Vertical 1/4 x 1-1/4 1/4 1-1/4 680 2720 470 1880 3/8 Vertical 1/4 x 1-1/2 1/4 1-1/2 910 3640 640 260 1/2 Vertical 3/8 x 2-3/4 3/8 2-3/4 200 8200 80 3400 1 8" thick hollow core plank tested 2 Allowable load capacities are calculated using an applied safety factor of 4:1 Page of 7

Order Information Wood Vertical Hangers: Zinc-Plated Carbon Steel and Length HTWV141420 1/4 1/4 x 2 Type 17 * Dia. HTWV381410 3/8 1/4 x 1 Type 17 HTWV381420 3/8 1/4 x 2 Type 17 1/8 HTWV381430 3/8 1/4 x 3 Type 17 HTWV383822 3/8 3/8 x 2-1/2 Type 17 HTWV123822 1/2 3/8 x 2-1/2 Type 17 *If required Wood Horizontal Hangers: Zinc-Plated Carbon Steel and Length HTWS381410 3/8 1/4 x 1 Type 17 * Dia. HTWS381420 3/8 1/4 x 2 Type 17 1/8 HTWS383822 3/8 3/8 x 2-1/2 Type 17 *If required Steel Vertical Hangers (#3 for Purlins, # for Beams): Zinc-Plated Carbon Steel and Length Self Drilling Range HTSV141410 1/4 1/4-20 x 1 #3 HTSV381420 3/8 1/4-20 x 2 #3 0.036 (20 gauge) to HTSV381410 3/8 1/4-20 x 1 (w/nut) #3 0.188 (3/16 ) HTSV381412 3/8 1/4-20 x 1-1/2 (w/nut) #3 HTSV381212 3/8 12-20 x 1-1/2 (w/nut) # 0.188 (3/16 ) HTSV121212 1/2 12-20 x 1-1/2 (w/nut) # to 0.00 (1/2 ) Page 6 of 7

Steel Horizontal Hangers (#3 for Purlins, # for Beams): Zinc-Plated Carbon Steel and Length Self Drilling Range HTSS381410 3/8 1/4-20 x 1 (w/nut) #3 0.036 HTSS381412 3/8 1/4-20 x 1-1/2 (w/nut) #3 (20 gauge) to HTSS381420 3/8 1/4-20 x 2 (w/nut) #3 0.188 (3/16 ) Conrete Vertical Hangers: Zinc-Plated Carbon Steel and Length Dia. HTCV141411 1/4 1/4 x 1-1/4 1/4 200 1000 HTCV381412 3/8 1/4 x 1-1/2 1/4 HTCV123823 1/2 3/8 x 2-3/4 3/8 0 20 Installation Tools Description/ Size HTWSST Universal Steel & Wood Socket 1 10 HTCST14 1/4 Concrete 1 10 HTCST38 3/8 Concrete 1 10 HTCST12 1/2 Concrete 1 10 For more information, please contact: Divisions of Mechanical Plastics Corp. 110 Richards Avenue Norwalk, CT 0684 Phone: 203-87-2200 Fax: 203-87-2201 E-mail: sales@wejit.com www.toggler.com www.wejit.com Hang-TITE, TOGGLER logo and typface, Wej-It and High-Performance Anchors are trademarks of Mechanical Plastics Corp. 2014 Mechanical Plastics Corp. Rev. 8/1 Page 7 of 7