Broadband Current Probe Series Operation Manual

Similar documents
Broadband Current Probe Series Operation Manual

Bulk Current Injection Probe Test Procedure

Current Probe Fixture Instruction Manual

Advanced Test Equipment Rentals ATEC (2832)

AK-18G Antenna Kit Operation Manual

SAS-563B Active Loop Antenna Operation Manual

SAS-562B Active Loop Antenna Operation Manual

Advanced Test Equipment Rentals ATEC (2832)

SAS-551 Passive Monopole Antenna Operation Manual

SAS-543 Biconical Antenna Operation Manual

TDS-535 Tuned Dipole Set Operation Manual

SAS Log Periodic Antenna Operation Manual

Current Probes. User Manual

Model Series. Current Probes MANUAL L L. ETS-Lindgren February 2005 Rev D PN

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

AK-285R Shielding Effectiveness Antenna Kit Operation Manual

Model 3106 Double-Ridged Waveguide Horn

Archived 3/18/10 USER MANUAL EMCO MODEL 3141 BICONILOG TM LOG-PERIODIC / T BOW-TIE ANTENNA Rev A 01/97

860 DSP & 860 DSPi Multifunction Interactive Cable Analyzer. Section VI: Appendix

Instruction Manual Model M Switch, DPDT, Manual Select

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas

Model 3116 Double-Ridged Waveguide Horn

Glass Electrode Meter

Model 3110B Biconical Antenna

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Model 935A Current Source Operation Manual

MODEL 3810/2 Line Impedance Stabilization Network

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

PARABOLIC ANTENNA MODEL MTA GHz 10.0 GHz

Trees, vegetation, buildings etc.

Model 3148 & Log-Periodic Dipole Array Antenna

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

80i-600A AC Current Probe

FISCHER CUSTOM COMMUNICATIONS, INC.

LOG PERIODIC ANTENNA MODEL LPA MHz - 1 GHz

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

Installation Instructions Hustler Collinear Two Meter Fixed Station Antenna Master Gainer Model G6-144B

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

REMOTE LOOP ANTENNA MODEL ALR khz 30 MHz

Log Periodic Dipole Array Antenna

PRODUCT SAFETY SOLUTIONS MODEL HWI-01. Model HWI-01 Serial Number:

LOOP ANTENNA MODEL ALR-30M. 9 khz 30 MHz

Broadband Step-Up Transformer. User Manual

742A Series Resistance Standards

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

USER GUIDE. WR284 Waveguide TRL Calibration Kit GHz. Models: WR284C30\32 Series (Rev A) 03/16

AMP-13 OPERATOR S MANUAL

Model 1791 VHF Radio User's Manual

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Log Periodic Antenna

150Hz to 1MHz magnetic field coupling to a typical shielded cable above a ground plane configuration

LUDLUM MODEL Low Energy Beta-Gamma Detector. December 2012 Serial No. PR and Succeeding Serial Numbers

SPM-50 RF Spectrum Power Meter PC Software User Manual

TETRIS User's Guide. High Impedance Active Probe DO177-1

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

HX-3 Headphone Distribution Amplifier

Type N Coaxial Calibration Kit

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

TETRIS 1000 High Impedance Active Probe. Instruction Manual

200Amp AC Clamp Meter + NCV Model MA250

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

USER GUIDE 2.92mm Coaxial Calibration Kit

HDTV Antenna. Contemporary Indoor. User s Guide

PI-10 Broadband Power Indicator

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Model BiConiLog Antenna. User Manual

o-ring grease can be used to hold the o-ring in the groove during installation.

Instruction Manual CT-6 High Frequency AC Current Probe

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

VT1586A Rack Mount Terminal Panel Installation and User s Manual

AT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok

INSTRUCTION MANUAL. Specifications Electrical. Front-To-Back Ratio VSWR at Resonance Less than 1.5:1 Nominal Impedance. Mechanical

Pen Multimeter. Model

SureCall TM CM800 65dB

Model Biconical Antenna. User Manual

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

High Performance Microphone Splitter. Artcessories. User's Manual

SEARCH LITE OPERATION MANUAL

Grid Radar Installation Manual

PDB4. Four Channel Passive Direct Box USER'S GUIDE

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

TA MHz oscilloscope probe TA MHz oscilloscope probe

Radio Remote Controls Manual K Series

Two Element Phased Vertical Array System

LUDLUM MODEL BGO Scintillator. June 2018

INSTRUCTION MANUAL TRI-PLATE LINE MODEL EM-7310

K1FO 12 ELEMENT 144/147 MHz YAGI

FRYCORDER Power Cord Burn-in Generator

TIA-3000 Optical/Electrical Converter. Operating Instructions

INSTRUCTION MANUAL FOR MICROELECTRODE AC AMPLIFIER MODEL 1800

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER

3M Power Clamp Wiremount Connectors

TRANSDUCER IN-LINE AMPLIFIER

MFJ-2389 Compact 8 Band Vertical

TIA-952 Optical/Electrical Converter. Operating Instructions

o-ring grease can be used to hold the o-ring in the groove during installation.

SureCall TM CM dB Dual Band Universal Inbuilding Repeater

Transcription:

Broadband Current Probe Series Operation Manual 1

TABLE OF CONTENTS WARRANTY 3 INTRODUCTION 4 GENERAL INFORMATION 5 OPERATING INSTRUCTIONS 6 FORMULAS 7 MAINTENANCE 8 2

WARRANTY INFORMATION A.H. Systems Inc., warrants that our Antennas, Sensors and Probes will be free from defects in materials and workmanship for a period of three (3) years. All other products delivered under contract will be warranted for a period of two (2) years. A.H. Systems' obligation under this warranty shall be limited to repairing or replacing, F.O.B. Chatsworth, California, each part of the product which is defective, provided that the buyer gives A.H. Systems notice of such defect within the warranty period commencing with the delivery of the product by A.H. Systems. The remedy set forth herein shall be the only remedy available to the buyer, and in no event shall A.H. Systems be liable for direct, indirect, incidental or consequential damages. This warranty shall not apply to any part of the product which, without fault of A.H. Systems has been subject to alteration, failure caused by a part not supplied by A.H. Systems, accident, fire or other casualty, negligence, misuse or normal wear of materials. Except for the warranty set forth above, there are no other warranties, expressed or implied, with respect to the condition of the product or it's suitability for the use intended for them by the buyer. For prompt service, please contact our service department for a Return Material Authorization Number before shipping equipment back to us. 3

INTRODUCTION ANTENNA SPECIFICATIONS Transfer Impedance (db) Max continuos Current (Amps) Model Number Frequency Range Aperture (inches / CM) Diameter (inches / CM) BCP-510 20 Hz 1 MHz -40 to -30 100 1.2 / 3.0cm 3.9 / 9.9cm 1.7 BCP-511 20 KHz 100 MHz -11 to +1 350 1.2 / 3.0cm 3.9 / 9.9cm 1.8 BCP-512 1 MHz 1 GHz 0 to 24 200 1.2 / 3.0cm 2.8 / 6.3cm 0.5 BCP-514 10 KHz 100 MHz -16 to 0 350 2.7 / 6.9cm 5.0 / 12.7cm 2.5 BCP-515 1 MHz 400 MHz -12 to 17 300 1.2 / 3.0cm 2.8 / 7.1cm 0.3 BCP-516 10 KHz 50 MHz -5 to 12 800 1.2 / 3.0cm 3.7 / 9.4cm 2.5 BCP-517 10 KHz 50 MHz -3 to -7 800 2.6 / 6.6cm 5.6 / 14.2cm 2.1 BCP-518 100 KHz 500 MHz 8 to 15 200 2.7 / 6.9cm 5.0 / 12.7cm 2.5 BCP-519 100 Hz 100 MHz -40 to 17 200 2.6 / 6.6cm 5.5 / 14cm 6.0 BCP-520 10 KHz 500 MHz -19 to 20 350 1.2 / 3.0cm 3.9 / 9.9cm 1.8 BCP-521 10 KHz 1 GHz 0 to 25 200 1.2 / 3.0cm 3.9 / 9.9cm 1.4 BCP-522 1 KHz 200 MHz -30 to 0 100 1.2 / 3.0cm 2.8 / 7.1cm 0.5 BCP-526 100 KHz 1 GHz -22 to -19 350 1.2 / 3.0cm 2.8 / 7.1cm 1.1 Weight (lb s / Kg) 4

GENERAL INFORMATION INTENDED PURPOSES This equipment is intended for general laboratory use in a wide variety of industrial and scientific applications, and designed to be used in the process of generating, controlling and measuring high levels of electromagnetic Radio Frequency (RF) energy. It is the responsibility of the user to assure that the device is operated in a location which will control the radiated energy such that it will not cause injury and will not violate regulatory levels of electromagnetic interference. GENERAL DESCRIPTION The measurement of conducted currents may be accomplished with different sensing devices. Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-5xx Current Probes are designed to permit field intensity meters, spectrum analyzers, and other 50Ω impedance instruments to measure quantitative magnitudes of current. Measurements can be made on single and multi-conductor cables, ground and bonding straps, shielded conduits and on coaxial cables. CIRCUIT The BCP-5xx series of probes are inserted primary types of electromagnetic current transformers. When a probe is clamped around a conductor, the conductor is the primary winding and the probes windings are the secondary. Current measurements are made by having the current carrying conductor pass through the aperature of the probe and the probe's output voltage measured with a calibrated field intensity meter or spectrum analyzer. The supplied Current Probe calibration is then used to convert the reading from the receiver as follows: dbµa = dbµv (from Receiver) - Transfer Impedance (dbω) 5

OPERATING INSTRUCTIONS GENERAL USE INSTRUCTIONS In measuring the current in a single conductor, the probe is clamped around the conductor. In the instance of a two-conductor cable, the probe can be used to measure the effects of currents leaving and returning. A Current Probe will measure the resultant magnitude of current flow of all wires passing through the aperture. The balance of a twisted pair circuit can be determined by measuring each wire individually and then measuring both wires simultaneously. The ratio of the two measurements shows how well the balance has been achieved. A shielded multiple wire cable can be measured to show how much resultant leakage current is occurring. Measurements with and without the shield will identify the actual shielding effectiveness. INSTALLATION Typical Current Probe installation is show in Figure 1. The probe should be placed over the cable and clamped shut. The cable connecting the probe to the receiver must have 50Ω characteristic impedance and matching cable connectors. The cable must be well shielded since any leakage will cause erroneous readings. The receiver must have 50 ohm input impedance. Use precaution when measuring uninsulated conductors. If possible, de-energize the EUT during set-up. Also arrange to center the conductor in the aperture using additional insulation. figure 1 6

ANTENNA FORMULAS AND CALCULATIONS A specific Transfer Impedance Factor is associated with each frequency. This number is to be subtracted from the receiver reading in order to convert to dbua dbµa = dbµv (from Receiver) - Transfer Impedance (dbω) + cable Loss (db) EXAMPLE: Assume that the frequency of interest is 80 KHz and we need to find the current at this frequency. Connect the probe per figure 1 Frequency: 80 KHz Transfer Impedance: -2.76 db ohms Cable Loss: 0.1dB Receiver Reading: -33.0dBuV dbµa = dbµv (from Receiver) - Transfer Impedance (dbω) + cable Loss (db) dbµa = -33.0 - -2.76 + - 0.1 dbµa = -30.34 7

MAINTENANCE To ensure reliable and repeatable long-term performance, annual re-calibration of your current probe by A.H. is recommended. Our staff can recalibrate almost any type or brand of antenna. For more information about our calibration services or to place an order for antenna calibration visit our website at http://www.ahsystems.com or call 1(818) 998-0223. 8