THREE PHASE UNINTERRUPTIBLE POWER SUPPLY BASED ON TRANS Z SOURCE INVERTER

Similar documents
An Improved T-Z Source Inverter for the Renewable Energy Application

This paper deals with a new family of high boostvoltage inverters, called switched-inductor quasi-z-source inverters.

A Modified Single-Phase Quasi z source converter

ANALYSIS OF SINGLE-PHASE Z-SOURCE INVERTER 1

Energetic PV Cell Based Power Supply Management Using Modified Quasi-Z-Source Inverter

Quasi Z-Source DC-DC Converter With Switched Capacitor

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Design of Chopper Fed Z Source PWM Inverter

Simulation of Z-Source Inverter Fed Induction Motor

Simulation of Single Phase Grid Connected Photo Voltaic System Based On PWM Control Of Switched Boost Inverter For DC Nanogrid Applications

New Shoot Through Control Methods for qzsi with Voltage Stress Reduction-Based DC/DC Converterer

@IJMTER-2016, All rights Reserved 241

Design and Implementation of Quasi-Z-Source Inverter for Off-grid Photovoltaic Systems

Current Mode Integrated Control Technique for Z-Source Inverter Fed Induction Motor Drives

A Switched Capacitor Based Active Z-Network Boost Converter

Maximum Constant Boost Control of the Z-Source Inverter

Switched Coupled Quasi Z Source Inverter for Photovoltaic Power Generation System

SIMULATION AND FABRICATION OF SINGLE PHASE Z-SOURCE INVERTER FOR RESISTIVE LOAD

ABSTRACT INTRODUCTION IRAN IRAN ISSN: OPEN ACCESS ARTICLE.

Design and Implementation of Three Phase Γ-Z Source Inverter for Asynchronous Motor

A Three-Phase AC-AC Buck-Boost Converter using Impedance Network

Z-SOURCE INVERTER WITH A NEW SPACE VECTOR PWM ALGORITHM FOR HIGH VOLTAGE GAIN

Hybrid Full-Bridge Half-Bridge Converter with Stability Network and Dual Outputs in Series

Research Note THREE PHASE ON-LINE UPS BY IMPLEMENTING T-SOURCE INVERTER WITH MAXIMUM CONSTANT BOOST PWM CONTROL *

I. INTRODUCTION A. GENERAL INTRODUCTION

IJREAT International Journal of Research in Engineering & Advanced Technology, Volume 1, Issue 1, March, 2013 ISSN:

Investigation of Sst Pwm in qzsi

714 IEEE TRANSACTIONS ON ENERGY CONVERSION, VOL. 24, NO. 3, SEPTEMBER 2009

Comparison of the Traditional VSI & CSI with Novel ZSI for Study the Pre-Dominate Harmonics Effect

THE increasing tension on the global energy supply has resulted

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Performance Analysis of Z-Source Cascaded H-Bridge Multilevel Inverter Based on Multi Carrier PWM Techniques

MODIFIED PWM CONTROL METHODS OF Z SOURCE INVERTER FOR DRIVE APPLICATIONS

Three Phase Trans-Quasi-Z-Source Inverter

International Journal of Advance Engineering and Research Development

Transient Step Response Specification of Z-Source DC-DC Converter

Design and Analysis for Various Controlling Methods of a Z-Source Inverter

A Novel Bidirectional DC-DC Converter with Battery Protection

Analysis of Novel DC-DC Boost Converter topology using Transfer Function Approach

SVPWM Technique for Cuk Converter

An ISO 3297: 2007 Certified Organization, Volume 3, Special Issue 2, April 2014

A Bi-directional Z-source Inverter for Electric Vehicles

Analysis and Simulations of Z-Source Inverter Control Methods

Impedance Source Inverter for Wind Energy Conversion System

CURRENTLY, the multilevel voltage-source inverter (VSI)

Modified Diode Assisted Extended Boost Quasi Z-Source Inverter for PV Applications

IN recent years, the development of high power isolated bidirectional

One-Cycle Control of Interleaved Buck Converter with Improved Step- Down Conversion Ratio

Simple Boost Control Method Optimized with Genetic Algorithm for Z-Source Inverter

International Journal of Research Available at

DYNAMIC VOLTAGE RESTORER USING THREE PHASE AC-AC CONVERTER

FUZZY CONTROL OF SHOOT THROUGH TIME OF SINGLE STAGE BOOST INVERTER WITH COUPLED INDUCTOR FED BY A FUEL CELL

Z-SOURCE INVERTERS: DESIGN AND APPLICATIONS

Analysis of switched inductor Z-source modified cascaded H-Bridge multilevel inverter

A Novel Bidirectional DC-DC Converter with high Step-up and Step-down Voltage Gains

DUAL VOLTAGE CONTROL OF REDUCED SWITCH HYBRID QUASI Z MULTILEVEL INVERTER FOR ISOLATED ENERGY SYSTEMS

High Frequency Soft Switching Of PWM Boost Converter Using Auxiliary Resonant Circuit

A NOVEL SOFT-SWITCHING BUCK CONVERTER WITH COUPLED INDUCTOR

A Novel Transformer Less Interleaved Four Phase High Step Down Dc Converter

Performance comparison of Quasi-Z-Source inverter with conventional Z-source inverter

Photovoltaic Grid-Connected System Based On Cascaded Quasi-Z-Source Network

Voltage Controlled Non Isolated Bidirectional DC-DC Converter with High Voltage Gain

Photovoltaic Power injected to the Grid with Quasi Impedence Source Inverter

A High Efficient DC-DC Converter with Soft Switching for Stress Reduction

SIMULATION STUDY OF QZSI Z-SOURCE INVERTER FOR RESISTIVE AND INDUCTIVE LOAD

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: ,p-ISSN: , PP

Closed Loop Control of the Three Switch Serial Input Interleaved Forward Converter Fed Dc Drive

Analysis and Design of a Bidirectional Isolated buck-boost DC-DC Converter with duel coupled inductors

Reduction of Ripple in the Bidirectional DC-DC Converter with the Coupled Inductor

An Interleaved High-Power Flyback Inverter with Extended Switched-Inductor Quasi-Z-Source Inverter for Pv Applications

Performance Analysis of Modified Z- Source Inverter for Renewable Energy System Using Modified Space Vector Pulse Width Modulation

Dynamic Performance Investigation of Transformer less High Gain Converter with PI Controller

A Novel Cascaded Multilevel Inverter Using A Single DC Source

II. L-Z SOURCE INVERTER

ANALYSIS AND SIMULATION OF Z-SOURCE INVERTER

Research Article Modified Embedded Switched Inductor Z Source Inverter

LLC Resonant Converter for Battery Charging Application

Design and Control of Switched-Inductor Quasi-Z-Source Inverter for Photovoltaic Applications

Photovoltaic Controller with CCW Voltage Multiplier Applied To Transformerless High Step-Up DC DC Converter

NOWADAYS, there is an increasing demand for low-cost

Shobhana D. Langde 1, Dr. D.P. Kothari 2 1,2 Electrical Engineering Department, R.T.M. Nagpur University.

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

PSIM Simulation of a Buck Boost DC-DC Converter with Wide Conversion Range

A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

A Pv Fed Buck Boost Converter Combining Ky And Buck Converter With Feedback

Performance Enhancement of Sensorless Control of Z-Source Inverter Fed BLDC Motor

Transient Analysis of Z-Source Inverter Fed Three-Phase Induction Motor Drive by Using PWM Technique

I. INTRODUCTION III. PROPOSED SYSTEM. A. Block Diagram

A Single Switch High Gain Coupled Inductor Boost Converter

A New ZVS Bidirectional DC-DC Converter With Phase-Shift Plus PWM Control Scheme

DC-DC booster with cascaded connected multilevel voltage multiplier applied to transformer less converter for high power applications

Levels of Inverter by Using Solar Array Generation System

Department of EEE, SCAD College of Engineering and Technology, Tirunelveli, India, #

Performance Metric of Z Source CHB Multilevel Inverter FED IM for Selective Harmonic Elimination and THD Reduction

Boost Converter for Power Factor Correction of DC Motor Drive

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

Design of Battery Assisted Quasi Z Source Inverter Using Space Vector Modulation for Hybrid Power System

ANALYSIS OF BIDIRECTIONAL DC-DC CONVERTER FOR LOW POWER APPLICATIONS

CHAPTER 5 Z-SOURCE MULTILEVEL INVERTER FOR UPS APPLICATIONS

Review of Impedance Source Dc-Dc Converters

Transcription:

THREE PHASE UNINTERRUPTIBLE POWER SUPPLY BASED ON TRANS Z SOURCE INVERTER Radhika A., Sivakumar L. and Anamika P. Department of Electrical & Electronics Engineering, SKCET, Coimbatore, India E-Mail: radhikamathan@gmail.com ABSTRACT UPS with traditional inverter requires additional step up transformer to boost the voltage. Due to the presence of step up transformer, the inverter current is much higher than the load current, this causes high stress across the switches. This paper proposes a new topology of uninterruptible power supply (UPS) by using a Trans Z-source inverter. The Trans Z source inverter solves this problem with reduced switching stress. Here the impedance network (two inductors with one capacitor) is placed in between battery and the inverter. Compared to traditional inverter, the Trans Z Source Inverter produces high voltage. Further, it reduces the current ripple. The simulation model of a 3-Kw UPS with the Trans Z-source inverter has been developed and verified. Keywords: shoot through vector, uninterruptible power supply, trans Z-source inverter. INTRODUCTION Uninterruptible power supply (UPS) systems are used to provide uninterrupted, reliable, and high quality power for sensitive loads. UPS provide a backup power circuitry when a power outage occurs. Applications of UPS systems include medical facilities, life supporting systems, data storage and computer systems, emergency equipment s, industrial processing, telecommunications, and on-line management systems. In conventional method there are three types of UPS [7]. The first method couples a battery bank to the inverter using transformer shown in Figure-1. The transformer is used to boost the level of voltage but it causes high current stresses on the switches. The transformer also increases the weight, volume and cost of the system. The second method couples a battery bank to a booster with inverter shown in Figure-2. This method requires additional booster which leads to high cost and low efficiency. It complicates the controlling of switches in the inverter. The dead time in the pulse width modulation (PWM) is required to prevent the upper and lower switches at the same leg. The third method [1] - [5] & [15] combine booster and inverter into a single stage power conversion shown in Figure-3. The level of the voltage is low and it increases the stresses. It is explained in papers [8] [10] and [14]. Figure-2. UPS with the combination of booster with inverter. Figure-3. UPS with Z source inverter. In this paper, a new topology using Trans Z source inverter is proposed. The advantages of this proposed paper are: 1. It increases the level of voltage 2. It reduces the voltage stresses 3. It reduces the input current ripple Figure-1. UPS with the combination of inverter and transformer. TRANS Z SOURCE INVERTER To overcome the problems in the traditional method the proposed method is implemented using Trans Z source inverter [13] and [11]. It employs a unique impedance network to combine the converter main circuit to the inverter, load. The Trans Z source inverter consist of 1365

an inductor L1 and L2 and capacitor C1 connected in T- shape is employed to couple the circuit with the inverter. In case of power outage the battery bank supplies power to the inverter. The inverter consist of Trans Z source symmetrical network (L1 = L2 and C1) and inverter (S1 S6). When the shoot-through vectors are taken the load is shorted by upper and lower switches on the same leg of the inverter. The proposed UPS can boost the voltage by using shoot-through vectors shown in Figure-4. Where, (8) (9) B is the boost factor. If the voltage across the inductor Ls is ignored, the output peak voltage is (10) Figure-4. Proposed UPS with Trans Z source inverter. The inductor (L1 and L2) have the same inductance, the Trans Z source network becomes symmetrical. From the symmetrical and equivalent circuit in Figure-5 (a) the voltage equation can be derived as The voltage equation of the non-shoot through states are derived as, Substituting (2) into (3) yields (1) (2) (3) Where V1m is the peak value of fundamental voltage of the inverter and m is modulation index (m 1). The selection of the boost factor and the modulation index can obtain the desired ac output voltage regardless of the battery bank voltage. The transfer function of the inverter is given as, (11) Where T0/Ts=d is the shoot through duty period. The high switching frequency fs = 1/Ts. The capacitor voltage over one switching period is constant, which is equal to average input voltage. When the Z-source inverter is working in shootthrough states shown in Figure-5 (b) during time interval T0, where T0 = Ts T1, and Ts is the switching period, the inverter can be considered as a short circuit. The voltage equation of the Trans Z-source inverter at shoot-through states are, The average voltage of inductor L1 (or L2) over one switching period in steady-state operation is zero (4) (5) Or (6) Substituting (7) into (4) gives (7) Figure-5. Equivalent circuit of Trans Z source inverter a) non shoot through b) shoot through. 1366

CONTROL OF PROPOSED UPS WITH TRANS Z SOURCE INVERTER The control of inductor current i L in the inner loop and the output voltage V 0 in the outer loop shown in Figure-6 and it is based on paper [6] and [7]. Figure-6. Control system of Trans Z source inverter for the proposed UPS system. Inner Loop The current feed forward control of the inner loop has eliminated the load current disturbance shown in Figure-7. (12) Where il is the current across the filter. iref is the reference voltage obtained from the comparison of voltage. Figure-7. Block diagram of inner loop. Figure-8. Block diagram of outer loop. Shoot Through Zero Vector Control The zero vectors can be controlled to boost the capacitor voltage in the Trans Z-source network, which maintain the desired level of the average input voltage of the Trans Z-source inverter. When the battery bank voltage drops, voltage across the capacitor of the Trans Z- source inverter also drops. Thus, the voltage difference between the reference and the actual capacitor voltage is sent to the PI controller which generates the shoot-through zero vectors. The shoot through zero vectors can be calculated as, (16) where H is the height of carrier wave. B is the width of carrier wave. H1 value is obtained by comparing the voltage across the battery and the reference value. SIMULATION RESULTS The simulation model of a 3-Kw UPS with the Trans Z-source inverter has been developed. The voltage and current waveform across the load of the proposed UPS are shown in Figure-9 and 10. The DC link Voltage of Trans Z Source Inverter is shown in Figure-11. Outer Loop The output voltage V 0 is regarded as a disturbance to the current inner loop. To smooth the output voltage, a voltage feed forward control is adopted shown in Figure-8. (13) Where Kw is the transfer function of voltage feed forward controller. The voltage across the inductor Ls can be given as, (14) (15) Figure-9. Voltage and current waveform across the load of the proposed UPS-open loop. 1367

developed in MATLAB Simulink software and the results are verified. ACKNOWLEDGEMENTS The authors would like to thank the management of Sri Krishna college of Engineering and Technology for their encouragement and support. REFERENCES [1] F. Z. Peng, Z-source inverter, IEEE Trans. Ind. Appl., vol. 39,pp. 504 510, Mar./Apr. 2003. [2] F. Z. Peng, M. Shen, and Z. Qian, Maximum boost control of the Z-source inverter, IEEE Trans. Power Electron., vol. 20, pp. 833 838, Jul.2005. Figure-10. Voltage and current waveform across the load of the proposed UPS-closed loop. [3] M. Shen, J. Wang, A. Joseph, F. Z. Peng, L. M. Tolbert, and D. J. Adams, Constant boost control of the Z-source inverter to minimize current ripple and voltage stress, IEEE Trans. Ind. Appl., vol. 42, pp. 770 778, May/Jun. 2006. [4] P. C. Loh, D. M. Vilathgamuwa, G. J. Gajanayake, Y. R. Lim, and C. W. Teo, Transient modeling and analysis of pulse width modulated Z Source Inverter, IEEE Trans. Power Electron., vol. 22, pp. 498 507, Mar. 2007. Figure-11. DC link voltage of Trans Z source inverter. Table-1. Comparison of theoretical and simulated values in open loop. [5] Y. Huang, M. S. Shen, F. Z. Peng, and J.Wang, Z- Source inverter for residential photovoltaic systems, IEEE Trans. Power Electron, vol.21, pp. 1776-1782, Nov 2006. [6] M. Shen, A. Joseph, J. Wang, F. Z. Peng, and D. J. Adams, Comparison of traditional inverters and Z- source inverter for fuel cell vehicles, IEEE Trans. Power Electron., vol. 22, pp. 1453 1463, Jul. 2007. [7] Z. J. Zhou, X. Zhang, P. Xu, and W. X. Shen, Single-phase uninterruptible power supply based on Z-source inverter, IEEE Trans. Ind. Electron., vol. 55, pp. 2997 3004, Aug. 2008. Table-1 shows the comparative results of Inverter and Trans ZSI. This results show us the increment of voltage with less size, cost, and weight. CONCLUSIONS The traditional Z Source inverter is well suited only for low modulation index condition. However, for high modulation index the stress across the switches are high. To sort out this problem Trans Z Source inverter has been introduced. In this paper a three phase uninterruptible power supply using Trans Z source inverter has been designed and simulated. A model for 3- Kw UPS with the Trans Z-source inverter has been [8] J. Anderson and F. Z. Peng, Four quasi-z-source inverters, in 2008 Proc. IEEE PESC, pp. 2743 2749. [9] P. C. Loh, P. C. Tan, and F. Blaabjerg, Three Level AC-DC-AC Z- Source Converter using reduced passive component count, IEEE Trans. Power Electron., vol.24, pp 1671-1681, Jul.2009. [10] A. H. Rajaei, M. Mohamadian, S. M. Dehghan, and A. Yazdian, Single phase induction motor drive system using z-source inverter, IET Elect.Power Appl., vol. 4, pp. 17 25, Jan. 2010. [11] M. Zhu, D. Li, P. C. Loh and F.Blaabjerg, Tappedinductor Z-source inverters with enhanced voltage 1368

boost inversion abilities, in 2010 Proc. IEEE Sustainable Energy Technologies (ICSET), pp. 1 6. [12] S.Yang, F.Z.Peng, Q. Lei, R.Inoshita and Zhaoming Qian., Current-fed quasi-z-source inverter with voltage buck-boost and regeneration capability, IEEE Transactions on Industrial Applications, Vol.47, no.2, pp.882-892, Mar/Apr.2011. [13] W. Qian, F. Z. Peng, and H. Cha, Trans-Z-source inverters, IEEE Trans. Power Electron., vol. 26, pp. 3453 3463, Dec. 2011. [14] L. Huang, M. Zhang, L. Hang, W. Yao, and Z. Lu, A Family of Three-Switch Three-State Single-Phase Z- Source Inverters, IEEE Trans. Power Electron, vol. 28, pp.2317-2329, May.2013. [15] A.Radhika and L.Sivakumar, An overview on impedance source inverter control methods, types and performance, International Journal of Applied Engineering Research, vol.10, pp. 33215-33225, Nov.2015. 1369