Transformers, Power Supply Units and Socket Outlets

Similar documents
10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Type CP-S, CP-C & CP-A Switch mode

For Immediate Delivery call KMParts.com at (866)

Electronic timer CT-SDD.22

QUINT-PS-24DC/24DC/10

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Thermistor motor protection relays

Power supply CP-D 24/4.2 Primary switch mode power supply

Three-phase monitoring relays CM-PFE and CM-PFE.2

MINI-PS AC/24DC/1.3

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Power supply CP-E 24/0.75

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Power supply CP-D 24/1.3

QUINT-PS AC/24DC/40

08/07/2015

Power supply CP-E 24/2.5

Power supply CP-D 12/2.1

Power supply CP-E 24/20.0

Installation / Monitoring Technique

Switching power supplies CP range, Linear power supplies CP-L range. Content

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Electronic timer CT-SDS.22

Subject to changes 11/2003 Page 1/7

Power supply CP-E 24/2.5

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

QUINT-PS/ 3AC/24DC/10

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Thermistor motor protection relays

05/09/2012

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Electronic timer CT-TGD.22

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

CP-E range Benefits and advantages

MINI-PS AC/2X15DC/1

CP-T range Product group picture

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Solid-state Twin Timer

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

08/07/2015

Description Basic devices with positive operation contacts

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

QUINT-PS/ 3AC/24DC/40

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

02/11/2015

Power supply CP-T 48/20.0 Primary switch mode power supply

Three-phase monitoring relay CM-PFS

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

22/10/2012

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Power supply CP-T 24/10.0 Primary switch mode power supply

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Power supply CP-T 24/40.0 Primary switch mode power supply

Liquid level monitoring relay CM-ENS.2x

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Installation- / Monitoring Technique

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

02/11/2015

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Three-phase monitoring relay CM-PVE

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

CP-T range Benefits and advantages

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

02/11/2015

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Overcurrent Protection / 7SJ45

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Protection and safety SQZ3 phase and sequence relay

Protection components

Primary switch mode power supplies Product group picture

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Transcription:

Transformers, Power Supply Units and Socket Outlets /2 Introduction /3 4AC3 bell transformers /4 4AC3 safety transformers /5 4AC2 power supply units /6 5TE6 REG socket outlets For further technical product information: Configuration Manual Transformers, Power Supply Units and Socket Outlets 2014 Ariticle No.: 3ZW1012-4AC32-0AC1 Service & Support Portal: www.siemens.com/lowvoltage/productsupport Product List: Technical specifications Entry List: Certificates / Characteristics / Download / FAQ / Manuals / Updates Siemens LV 10 2014

Introduction Devices Page Application Standards Used in 4AC32 bell transformers /3 Power supply up to 18 VA as safety extra-low voltage (SELV) in residential buildings for the supply of gongs, buzzers, bells, door openers and remote control switches EN 61558-1 EN 61558-2-8 Non-residential buildings Residential buildings Industry -- 4AC37 safety transformers /4 Power supply up to 63 VA as safety extra-low voltage (SELV) for the supply of control circuits, switching relays and Insta contactors EN 61558-1 EN 61558-2-6 -- 4AC2 power supply units /5 Direct voltage power supply up to 24 V DC and 2 A as safety extra-low voltage (SELV) for the supply of gongs, buzzers, bells, door openers, switching relays and Insta contactors EN 61558-2-6 5TE6 REG socket outlets /6 For power supply during maintenance in distribution boards in DIN VDE, CEE 7, CEI 23-50 and UL 48 versions DIN VDE 0620-1, CEE 7 standard sheet V, CEI 23-50, UL 48 /2 Siemens LV 10 2014

4AC3 bell transformers A typical application for these bell transformers is short-time use, as occurs with bells, gongs, door openers or remote control switches in residential buildings. Siemens bell transformers are protected against short-circuit or moderate overload by a PTC resistor. After a short circuit, the primary current must be briefly disconnected from the mains before restarting. Higher output voltages will occur in the event of low-load or no-load operation. Technical specifications 4AC3208-0 4AC3208-1 4AC3214-0 4AC3218-0 Standards EN 61558-1:2005, EN 61558-2-8:2010 Rated operational power P s VA 8 8 14 18 Rated operational voltage U e V AC 230 Operating range at 50 Hz U e 1.04 Rated frequency Hz 50 Rated secondary voltage U sec V AC -- -- -- 4 V AC 8 8 8 8 V AC -- 12 12 12 V AC -- -- 24 -- Rated secondary current I sec At 4 V A AC -- -- -- 2.0 At 8 V A AC 1.0 1.0 2.0 2.0 At 12 V A AC -- 0.6 1.3 1.5 At 24 V A AC -- -- 0.6 -- Rated power dissipation P V In no-load operation W 1.2 1.2 1.3 1.3 At a rated voltage of 4 V W -- -- -- 5.5 At a rated voltage of 8 V W 5.7 5.7 10.5 8.1 At a rated voltage of 12 V W -- 3.8 7.4 8.4 At a rated voltage of 24 V W -- -- 4.2 -- Safe separation Creepage distances and mm > 6 clearances Insulation class E Test voltage, 50 Hz, 1 second Primary against secondary winding kv 4 Conductor cross-sections Rigid mm 2 1 x 4 or 2 x 2.5 Flexible, with end sleeve mm 2 1 x 2.5 or 2 x 1.5 Permissible ambient temperature C 40 35 40 40 Permissible humidity % 1 Degree of protection Acc. to EN 6062 IP20 Safety class Acc. to EN 61140 (VDE 0140-1) II Selection and ordering data U e U sec I sec P s Mounting SET, M) V AC V AC A AC VA MW kg Bell transformers 230 8 1.0 8 2 4AC3208-0 1 1 unit 028 0.241 8/12 1.0/0.6 8 2 4AC3208-1 1 1 unit 028 0.266 8/12/24 2.0/1.3/0.6 14 2 4AC3214-0 1 1 unit 028 0.376 8/12 2.0/1.5 18 2 4AC3218-0 1 1 unit 028 0.358 Circuit diagrams 4 8 I201_1846 4 6 8 I201_18470 4AC3208-0 4AC3208-1 4AC3214-0 4AC3218-0 4 6 8 24V I201_18471 4V 4 6 8 I201_18472 Siemens LV 10 2014 /3

4AC3 safety transformers These transformers up to 63 VA provide a safety extra-low voltage for supplying control circuits, switching relays or Insta contactors in continuous operation as alternating voltage power supply for 8 V, 12 V, 16 V, 24 V and 32 V AC. Higher output voltages will occur in the event of low-load or no-load operation. Siemens safety transformers are protected against short circuit or moderate overload by a PTC resistor. After a short circuit, the primary current must be briefly disconnected from the mains before restarting. Technical specifications 4AC3716-0 4AC3724-0 4AC3740-0 4AC3740-1 4AC3763-0 Standards EN 61558-1:2005, EN 61558-2-6:200 Rated operational power P s VA 16 24 40 40 63 Rated operational voltage U e V AC 230 Operating range at 50 Hz U e 1.04 Rated frequency Hz 50 Rated secondary voltage U sec V AC 8 8 -- -- -- V AC -- -- 12 12 2 12 V AC -- 12 -- -- -- V AC -- -- -- 16 -- V AC -- -- 24 24 24 V AC -- -- -- 32 -- Rated secondary current I sec At 8 V A AC 2.0 2.0 -- -- -- At 12 V A AC -- 2.0 3.3 3.3 5.2 At 16 V A AC -- -- -- 2.5 -- At 24 V A AC -- -- 1.6 1.6 2.6 At 32 V A AC -- -- -- 1.2 -- Rated power dissipation P V In no-load operation W 1.1 1.1 3.5 3. 3. At a rated voltage of 8 V W 6.8 4.6 -- -- -- At a rated voltage of 12 V W -- 7.6 7..5 13.2 At a rated voltage of 16 V W -- -- -- 7.7 -- At a rated voltage of 24 V W -- -- 7.7 8.1 13.5 At a rated voltage of 32 V W -- -- -- 7.6 -- Safe separation Creepage distances and clearances mm > 6 Insulation class E F Test voltage, 50 Hz, 1 second Primary against secondary winding kv 4 Conductor cross-sections Rigid mm 2 1 x 4 or 2 x 2.5 Flexible, with end sleeve mm 2 1 x 2.5 or 2 x 1.5 Permissible ambient temperature C 25 Permissible humidity % 1 Degree of protection Acc. to EN 6052 IP20 Safety class Acc. to EN 61140 (VDE 0140-1) II Selection and ordering data U e U sec I sec P s Mounting SET, M) V AC V AC A AC VA MW kg Safety transformers 8 2.0 16 2 4AC3716-0 1 1 unit 028 0.413 8/12 2.02.0 24 3 4AC3724-0 1 1 unit 028 0.610 230 12/16/24/32 3.3/2.5/1.6/1.2 40 5 4AC3740-1 1 1 unit 028 1.220 12/24 3.3/1.6 40 5 4AC3740-0 1 1 unit 028 1.186 2 x 12/24 5.2/2.6 63 5 4AC3763-0 1 1 unit 028 1.321 Circuit diagrams 1 11 1 11 1 11 4 8 I201_18473 4 6 8 I201_18474 6 8 10 12 6 8 10 12 24V I201_18476 6 8 10 12 6 8 10 12 2 4 10 12 2 4 10 12 24V 16V 32V 4AC3716-0 4AC3724-0 4AC3740-0 4AC3740-1 4AC3763-0 I201_18477 6 8 10 12 6 8 10 12 24V I201_18475 /4 Siemens LV 10 2014

4AC2 power supply units The electronic power supply unit provides a 24 V DC supply to systems with an operational voltage of 85... 265 V AC or 85... 300 V DC. The device operates in the lower class for minimum power supply with a safety extra-low voltage (SELV). The electronic power supply unit is suitable for supplying the 5TT71 GSM alarm modules within a supply voltage range of 150 to. Technical specifications 4AC2402 Standards EN 60068-2, EN 61558-1, EN 61000-4 Approvals -- Rated operational power P s W 8.4 Rated operational voltage U e V AC 85... 265 V DC 85... 300 Permissible operational voltage For the 5TT71 GSM alarm modules V AC/DC 150... 265 Primary operating range At 50/60 Hz U e -- Rated frequency Hz 50/60 Operating frequency range Hz -- Rated secondary voltage U sec V DC 24 ± 5 % Rated secondary current I sec A DC 0.35 Current limitation Electronic overload protection Residual ripple mv < 100 Rated power dissipation P v In no-load operation W -- At rated load W -- Hum-free Core molded -- Safe separation Creepage dist. and clearances mm > 5.5 Insulation class -- Test voltage Primary against secondary winding 50 Hz, 1 min kv -- Insulation resistance kv 4 Rated impulse withstand voltage/ Acc. to IEC 60664-1 6 kv/2 degree of pollution Static discharge Acc. to IEC/EN 61000-4-2 kv 8 RF irradiation Acc. to IEC/EN 61000-4-3 V/m 10 Transient overvoltage (burst) Acc. to IEC/EN 61000-4-4 kv 4 Transient overvoltage (surge) Acc. to IEC/EN 61000-4-5 Supply lines A1, A2 kv 1 A1/A2 and ground kv 2 RF, conducted disturbance Acc. to IEC/EN 61000-4-6 V 10 Interference suppr. to lower limit class Acc. to EN 61000-6-3 Complied with Terminals Screw (slotted-head) M2.5 ±screw (Pozidriv) -- Conductor cross-sections Rigid mm 2 0.5... 2.5 Flexible, with end sleeve, min. mm 2 0.5... 1.5 Permissible ambient temperature C -20... +60 Permissible humidity % Resistance to climate Acc. to IEC/EN 60068-1 20/045/04 Resistance to vibrations Acc. to IEC/EN 60068-2-6 mm 0.35 amplitude Frequency 10... 55 Hz Degree of protection Acc. to EN 6052 IP20, with connected conductors Safety class Acc. to EN 61140 II Selection and ordering data U e U sec I sec P s Mounting SET, M) V AC V DC V DC A DC W MW kg Electronic power supply unit SELV, short-circuit resistant 85... 265 85... 300 24 ± 5 % 0.35 8.4 2 4AC2402 1 1 unit 028 0.081 Siemens LV 10 2014 /5

5TE6 REG socket outlets The socket outlets for mounting in distribution boards to DIN 43880 and on standard mounting rails to DIN 60715 have since become standard in modern switchgear assemblies/distribution boards. The socket outlet range complies with a number of different standards and is available according to the standards of the following countries: VDE for Germany, CEE7 for Belgium/France, CEI for Italy and UL for USA. In distribution boards with 55 mm mounting depth the socket outlet can only be used without the hinged lid. The lids can be retrofitted on all devices. In system components where equipment is still live even after the main switch has been disconnected, this must be indicated according to EN 50110-1 (VDE 0105-1) and IEC/EN 60204-1/VDE 0113-1. Yellow socket outlets are used for these applications. Technical specifications 5TE6800 5TE6801 5TE6810 5TE6802 5TE6803 5TE6804 Standards VDE 0620-1 VDE 0620-1 VDE 0620-1 CEI 23-50 CEE 7 standard UL 48 sheet V Approvals VDE 0620-1 -- UL File No. E25858/ CSA C22.2 No. 182.3M Rated operational voltage U e V AC 230 125 Rated operational current I e A AC 16 15 Terminals ±screw (Pozidriv) PZ1 Terminal tightening torque, max. N 1.2 Stripped length mm 10 Conductor cross-sections Rigid mm 2 1.5... 6 Flexible, with end sleeve mm 2 0.5... 4 Rigid AWG 10... 14 Flexible AWG 14 Permissible ambient temperature C -10... +55 Degree of protection Acc. to EN 6052 IP20, with connected conductors Mounting position Without cover: any, with cover: vertical or horizontal Selection and ordering data U e I e Conductor cross-section Mounting SET, M) V AC A mm 2 MW kg SCHUKO socket outlets according to DIN VDE 0620-1 Without hinged lid 230 16 6 2.5 } 5TE6800 1 1 unit 02 0.086 SCHUKO socket outlets according to DIN VDE 0620-1 With hinged lid 230 16 6 2.5 } 5TE6801 1 1 unit 02 0.03 /6 Siemens LV 10 2014

5TE6 REG socket outlets U e I e Conductor cross-section Mounting SET, M) V AC A mm 2 MW kg SCHUKO socket outlets according to DIN VDE 0620-1 Without hinged lid, yellow RAL 1018 230 16 6 2.5 } 5TE6810 1 1 unit 02 0.08 Socket outlets according to CEI 23-50 With hinged lid 230 16 6 2.5 } 5TE6802 1 1 unit 02 0.03 Socket outlets according to CEE 7 Standard sheet V Without hinged lid, with grounding pin 230 16 6 2.5 } 5TE6803 1 1 unit 02 0.08 UL 48 socket outlets Without hinged lid 125 15 6 2.5 } 5TE6804 1 1 unit 02 0.088 Hinged lids for 5TE6 socket outlets 2.5 5TE120 1 1 unit 02 0.01 Siemens LV 10 2014 /7

Notes /8 Siemens LV 10 2014