ARMTEC.COM. Built to last. Custom Precast Solutions For Your Home. Custom Steps Custom Decks Standard Steps Window Wells Brackets Stairwells

Similar documents
ARMTEC.COM. Built to last. Custom Precast Solutions For Your Home. Custom Steps Custom Decks Window Wells Stairwells Brackets

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

ABOUT INLAND. Tannis Karklin, E.I.T Technical Sales and Marketing

Designing Precast Concrete School Buildings

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

UNDERGROUND AND UTILITIES

Reinforcing Mesh Product Guide

NORTH AMERICAN STEEL INNOVATIVE STORAGE SOLUTIONS OUR S T R E N G T H IS OUR PEOPLE NORTH AMERICAN RACK

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

OHIO DEPARTMENT OF TRANSPORTATION CENTRAL OFFICE, 1980 W. BROAD ST., COLUMBUS, OHIO

MANuFACturers industry QuALity statement.

Reinforcing Mesh Product Guide

A. Extent of structural precast concrete work is shown on drawings and in schedules.

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

Erstantie 2, FIN Villähde Tel , Fax

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

Products Beams Columns Load bearing wall panels Insulated Non-insulated Non-load bearing wall panels Insulated Non-insulated

Cooke Precast Concrete

Making Building Easy

2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo

Total Precast Concrete Structures

StormTrap Guide Specification. StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18

Standard Specifications

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

3400 Tectura Designs Precast Concrete

Cooke Precast Concrete

Designer s NOTEBOOK DESIGN ECONOMY, PART 3

1. Architectural precast concrete cladding units.

SUBSTATION SECURITY WALL INSTALLATION MANUAL

GUIDELINE SPECIFICATIONS

TABLE OF CONTENTS INTRODUCTION REBAR INSTALLATION SERVICES SPACERS MESH WIRE FENCING CONSTRUCTION PLASTICS HOLD DOWN BOLTS

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

Toll-Free

Manholes Table of Contents

Determine the stairway pitch based on tread and riser dimensions. For the main stairway in a house, the pitch can be no greater than 37º.

shawprecastsolutions.com BEBO Arch Systems PRODUCT GUIDE & TECHNICAL REFERENCE MANUAL Providing the right solutions.

Construction Tolerances - The following tolerances apply to cast-in-place structures:

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

EKSPAN. Standard F Series Bearings. Description. Bearing types F series bearings are available in three forms - Typical 21F details.

ROUND STEEL POLE STRAIGHT

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

Advancements in precast concrete are

Design Manual for M.C.M.E.L ALUMINUM STAIRCASE System

White Paper WP008. Cover. 1/14 1/14 Architectural Precast Applications. Architectural Precast Applications

BPDL Architectural precast concrete specifications USA TESTING AND INSPECTION A. Testing by Independent Agency : Materials and workmanship furn

Cooke Precast Concrete

PRACTICE NOTE NO: 13 Version 1 Amended March 2001 Page 1 of 6 PRECAST CONCRETE ELEMENT DESIGN RESPONSIBILITIES AND CONTRACTUAL ARRANGEMENTS

Section 914. JOINT AND WATERPROOFING MATERIALS

UNDERGROUND UTILITY VAULTS

2013 Feeney (2/14) # B. Aluminum Railing Systems

BOX CULVERTS DRAINAGE & WATER MANAGEMENT. v2.1

Scheduling, dimensioning, bending and cutting of steel reinforcement for concrete Specification

21. HOT-DIP GALVANIZED COATING GUARANTEES

Abu Dhabi (Head Office) Dubai: Iraq:

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

Building Construction Details Practical Drawings Pdf

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

designmasterfence.com

Glass and Stainless Solutions

Slotted trunking halogen free

SQUARE STEEL POLE STRAIGHT

Total precast solution for large stadium projects meet tight schedule

SlipGrip Data Sheet & Installation Guide

SPECS. SPC-1

THE POWER OF RED SHORFAST CONCRETE CONSTRUCTION SOLUTIONS BROCHURE

2015 Feeney (8/15) # D. Aluminum Railing Systems

East African Roofing Systems Ltd.

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials.

CARES Technical Approval Report TA1-B 5042

Tech. Bulletin. Spacing. Positioning. Tile Brackets 6.1

Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations

Kee Gate Operation & Maintenance Manual

Delivering Reliability. Services. Strength You Can Count On. oldcastleprecast.com/services

Anti-Trust Statement

B. Installation Instructions. Provide installation instructions, including any special equipment, to address the following.

GUIDE SPECIFICATION FOR ARCHITECTURAL PRECAST CONCRETE (PCI MNL 117)

4-POST & CASE-TYPE SHELVING SYSTEMS

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

ROLE STATEMENT MERCER HUMAN RESOURCE CONSULTING

SECTION PRECAST HOLLOW CORE PLANKS

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)

APPLICATION FOR A BUILDING PERMIT

BOX CULVERTS DRAINAGE & WATER MANAGEMENT. v2.1

Multilift (B613 & B355)

Experience the Hi-Lite Advantage

Standard push bar panic and emergency exit devices.

Designer s NOTEBOOK SPECIFICATION GUIDANCE

10.2 GUIDE SPECIFICATION FOR ARCHITECTURAL/STRUCTURAL PRECAST CONCRETE

McNICHOLS MODULAR FACADE AND TRELLIS SYSTEMS. Inspired to Serve! mcnichols.com

Hyper ArmourMate. Joint Edge Protection INDUSTRIAL SLAB ON GROUND

Choose The Railing That Suits You Best!

JVI Vector Connector

We are specialized in steel processing, especially for home appliances and the furniture field, from design to manufacturing and installation

24" B B Joint X501 Joint See MARKINGS Note PCB-RXX-350-TL3 " X501 Y301 (Typ.) " A PLAN (reinforced casting option shown) A " dia. Hinge Bar (Typ.) NOT

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

Transcription:

ARMTEC.COM Built to last. Custom Precast Solutions For Your Home Custom Steps Custom Decks Standard Steps Window Wells Brackets Stairwells

PRESTIGE UNIVERSAL CUSTOM STEPS AND DECKS Universal design Custom features BROOM FINISH WTIH ETCHED RISERS RECESSED DECK WITH ETCHED RISERS

PRESTIGE UNIVERSAL CUSTOM STEPS AND DECKS Universal Custom Steps and Decks Armtec s precast concrete steps provide a welcoming entrance to homes and public buildings. Our steps have the look, quality and durability you expect with attractive and unique combinations of finishes that add character to your home. FULLY EXPOSED STEP CONSISTENT QUALITY YEAR ROUND AVAILABILITY ARCHITECTURAL DETAILS DURABLE, MAINTENANCE FREE RELIABLE DELIVERY PROFESSIONAL SERVICE Finish Choices Include: Broom finish with etched risers Broom finish with etched risers and sides Exposed concrete Tinted exposed concrete FULLY EXPOSED STEP UNIVERSAL CUSTOM STEPS AND DECKS 3

PRESTIGE UNIVERSAL CUSTOM STEPS AND DECKS Attractive finishes Long lasting FULLY EXPOSED STEP DECK WITH ETCHED RISERS AND SIDES BROOM FINISH STEPS WITH ETCHED RISERS UNIVERSAL CUSTOM STEPS AND DECKS 4

PRESTIGE UNIVERSAL CUSTOM STEPS AND DECKS Universal Custom Steps and Decks Finishes & Technical Details Armtec steps and decks are made using high strength air-entrained concrete that conforms to current CAN/CSA A23.1 CPCI standards and all local building codes. They are reinforced with deformed rebar, welded wire mesh and polypropylene fibers. Universal Steps Universal Decks CLASSIC BROOM FINISH STEP WITH ETCHED RISERS CLASSIC BROOM FINISH DECK WITH ETCHED RISERS CLASSIC BROOM FINISH STEP WITH ETCHED SIDES AND RISERS CLASSIC BROOM FINISH DECK WITH ETCHED SIDES AND RISERS EXPOSED STEP EXPOSED DECK UNIVERSAL CUSTOM STEPS AND DECKS 5

PRESTIGE UNIVERSAL CUSTOM STEPS AND DECKS Standard Precast Steps Armtec precast standard steps provide quality, durable entrances. Non-slip surfaces offer greater safety in wet conditions. We offer a variety of styles, from standard models to prestige or custom-built steps with architectural etched details, coloured concrete and unique surface finishes for increased visual impact. SANDBLAST FINISH YEAR ROUND AVAILABILITY ARCHITECTURAL DETAILS DURABLE CONSISTENT CAST QUALITY COST EFFECTIVE MAINTENANCE FREE Finish Choices Include: Smooth form finish Sandblast finish CLASSIC SMOOTH CONCRETE FINISH 6 STANDARD PRECAST STEPS

PRESTIGE UNIVERSAL CUSTOM STEPS AND DECKS Standard Steps FRONT ENTRY FRONT ENTRY - SANDBLAST FINISH A A SAND BLAST SAND BLAST A SAND BLAST SINGLE SIDE ENTRY DOUBLE SIDE ENTRY STANDARD PRECAST STEPS 7

PRESTIGE UNIVERSAL CUSTOM STEPS AND DECKS Front, Single Side and Double Side Entry Steps Available Widths 1 Riser Height 2 Riser Height 3 Riser Height 4 Riser Height FRONT 1200 (48) 230 (9) 415 (16¼) 600 (23¾) --- 1500 (60) 230 (9) 415 (16¼) 600 (23¾) 785 (31) 1800 (71) 230 (9) 415 (16¼) 600 (23¾) 785 (31) 2100 (82¾) 230 (9) 415 (16¼) 600 (23¾) 785 (31) 2400 (94½) 230 (9) 415 (16¼) 600 (23¾) 785 (31) 3000 (118) 230 (9) 415 (16¼) 600 (23¾) --- DOUBLE AND SINGLE SIDE 1070 (42⅛) 415 (16¼) 600 (23¾) 785 (31)* 1200 (47¼) 230 (9) 415 (16¼) 600 (23¾) 785 (31) *Double Entry Only Available Widths 5 Riser Height 6 Riser Height 7 Riser Height FRONT 1200 (48) 1500 (60) 970 (38¼) 1155 (45½) 1340 (52¾) 1800 (71) 970 (38¼) 1155 (45½) 2100 (821/2) 2400 (941/2) 3000 (118) CLASSIC SMOOTH FINISH DOUBLE AND SINGLE SIDE 1070 (421/3) 1200 (471/4) 970 (38¼) 1155 (45½) _ NOTE: All dimensions provided are +/-5mm (¼ ). Weights available by request. 8 STANDARD PRECAST STEPS

PRESTIGE UNIVERSAL CUSTOM STEPS AND DECKS CLASSIC SMOOTH FINISH Entry Front Entry Depth of Landing 1200mm (47¼ ) Single Side Entry 1500mm (59 ) Double Side Entry 1-4 Rise Steps 1500mm (59 ) Double Side Entry 5 Rise Steps 1200mm (47¼ ) Dimensions _ Riser Height Tread Depth Bottom Riser Height 185mm (7¼ ) 295mm (11½ ) 235mm (9¼ ). NOTE: The extra height on the bottom riser ensures that the step is below the finished grade of the walkway. STANDARD PRECAST STEPS 9

PRECAST WINDOW WELLS & STAIRWELLS Precast Window Wells Armtec s precast window well enhances the look of your home. They are available in a variety of sizes and finishes to match your style. EXPOSED FINISH YEAR ROUND AVAILABILITY ARCHITECTURAL DETAILS DURABLE CONSISTENT CAST QUALITY Finish Choices Include: Smooth formed concrete Exposed sandblast Exposed Tinted exposed concrete 10 PRECAST WINDOW WELLS

PRECAST WINDOW WELLS & STAIRWELLS Precast Window Wells Finishes & Technical Details Armtec s precast window wells are made using high strength air-entrained concrete that conforms to current CAN/CSA A23.1 CPCI standards and all standard building codes. They are reinforced with deformed rebar, welded wire mesh and polypropylene fibers. Technical Detail CSA Standard Concrete Strength Concrete Type A23.3-14, A23.4-09 35 MPa @ 28 Days Sulphate Resistant S2 Exposure Reinforcement Grade 400 Weight (smallest) 765 kg (1687 lbs) Product Detail Inside Dimension (B) PRECAST WINDOW WELLS 11 As Required.

PRECAST WINDOW WELLS & STAIRWELLS Precast Concrete Brackets Armtec precast concrete brackets are excellent for supporting steps, decks, sidewalks and posts. Brackets safely support allowable point loads stated in the chart below. Any loads over the indicated point loads, such as columns and roof structures, need need to be confirmed and checked by the contractor or home builder. SIDE VIEW FIG 1 C BOLT ASTM (A 307) A B 2 MAX BEND BAR DO NOT CUT REINFORCED 10M, 15M OR 20M (SEE CHART) BEND BAR DO NOT CUT WELD DETAIL AT BOLT 4 WELD BOTH SIDES (FILL IN GROOVE) 3 MAX BOLT ASTM (A 307) 2 MAX HORIZONTAL BAR WELD THIS BAR TO BOLT & HORIZONTAL REBAR VERTICAL BAR 12 PRECAST CONCRETE BRACKETS

PRECAST CONCRETE BRACKETS PRESTIGE FINISH STEP WITH ETCHING ON THE SIDES FULLY EXPOSED STEP Precast Concrete Brackets Technical Specifications Reinforcement M Length - A Height - B Allowable Point Load - C KN (fbs) 10 610 (24) 355 (14) 10.67 (2400) 10 915 (36) 355 (14) 7.56 (1700) 10 1065 (24) 480 (19) 10.22 (2300) 10 1220 (48) 480 (19) 9.33 (2100) 10 1320 ( 52) 480 (19) 6.67 (1500) 15 1525 (60) 610 (24) 10.67 (2400) 15 1625 (64) 610 (24) 9.78 (2200) 15 1830 (72) 610 (24) 8.89 (2000) 15 1980 (78) 610 (24) 8.44 (1900) 15 2135 (84) 610 (24) 7.11 (1600) 15 2440 (96) 610 (24) 6.22 (1400) 20 2745 (108) 760 (30) 4.44 (1000) 20 3000 (120) 760 (30) 4.00 (900) 20 (hump bracket) 1370 (54) 710 (28) 15.56 (3500) 20 (hump bracket) 1625 (64) 710 (28) 11.11 (2500) PRECAST CONCRETE BRACKETS 13

PRECAST CONCRETE BRACKETS Precast Stairwells Armtec Stairwells are made using high strength air-entrained concrete that conforms to current CAN/ CSA A23.1 CPCI standards and all standard building codes. They are reinforced with rebar, welded wire mesh and polypropylene fibers. CONCRETE STAIRWELL 14 PRECAST STAIRWELLS

PRECAST WINDOW WELLS & STAIRWELLS BROOM FINISH WITH ETCHED RISERS _ NOTE Armtec carries all requisite certifications at its operating sites including ISO 9001 quality certification or compliance, Canadian Standards Association (CSA) and Bureau de Normalization du Québec (BNQ) specifications for all applicable products and builds in CPCI certified plants. For information on specific certifications, please contact your regional Armtec office. FULLY EXPOSED STEPS BROOM FINISH WTH ETCHED RISERS Drawings and product details are for information and/or illustrative purposes only and may vary. Please contact your Armtec representative for the most current product information. Armtec is a leading Canadian infrastructure and construction materials company combining creative engineered solutions, relevant advice, dedicated people, proven products and a national presence with a local focus on exceptional customer service.

ACHESON PRECAST STEPS FACILITY Edmonton T: 780 960 1228 F: 780 960 2674 E: precastbuilders.edmonton@armtec.com 205-26229 Twp Rd 531A Acheson AB T7X 5A4 Calgary T: 403 279 8161 F: 403 279 6027 E: precastbuilders.calgary@armtec.com 8916 48th ST. SE Calgary, AB T2C 2P9 armtec.com