SmartLine Non-Contact Radar Level Meter Technical Datasheet. Specification. The Universal Radar Solution. Highlights. Industries.

Similar documents
SmartLine Non-Contact Radar Level Meter Technical Datasheet. Specification. The Universal Radar Solution. Highlights. Industries.

OPTIWAVE 6300 C Technical Datasheet

OPTIWAVE 6300 C Quick Start

OPTIWAVE 7300 C Technical Datasheet

Technical Datasheet. Guided Radar (TDR) Level Transmitter for heavy-duty and interface applications

OPTIWAVE 5200 C/F Technical Datasheet

OPTIWAVE 7400 C Technical Datasheet

OPTIWAVE 5400 C Technical Datasheet

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

OPTIWAVE 6500 C Technical Datasheet

XYR 6000 Wireless High Level Analog Input Transmitter Model STIW600 0 to 5 Volts 1 to 5 Volts 0 to 20 ma 4 to 20 ma

OPTIWAVE 1010 Technical Datasheet

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

Specification and Model Selection Guide. Introduction 34-XY /14/07. Figure 1 XYR6000 Temperature Transmitters

2-Wire. Level Gauge BM 702

OPTIWAVE 7300 C Supplementary instructions

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Rosemount 3101, 3102, and 3105

POWERFLEX 2200 C/F/S/D Technical Datasheet

XYR 6000 Wireless Transmitter Absolute Pressure Model. Specification and Model Selection Guide. Introduction 34-XY /13/07

OPTIWAVE 5200 C/F Quick Start

OPTIWAVE 7300 C. Non-contact Radar (FMCW) Level Meter

Coriolis Massflowmeter

OPTIWAVE 7300 C. Non-contact Radar (FMCW) Level Meter

Coriolis Mass Flow Meter Model TM

OEM radar transmitter, for aggressive media level measurement

TGF2200 Micro Pulse Level Meter

Level Measurement Continuous level measurement Radar transmitters

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Coriolis Massflowmeter

TGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE

TMU. Coriolis Mass Flow Meter. for liquids and gas

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Specification and Model Selection Guide. Introduction 34-XY /13/07

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

ED701 General Industry Pressure Transmitter

TIDALFLUX 2300 F Technical Datasheet

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications

OPTIMASS 1000 Technical Datasheet

Coriolis Massflowmeter

Level Measurement Continuous level measurement Radar transmitters

VITO LT. Global Experience. Locally Applied. A dependable choice.

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /24/06

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

LEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe

Design and applications

OPTIWAVE 7300 C Handbook

Radar Level Measurement micropilot FMR 130 for stilling wells

ProcessMaster / HygienicMaster

MicroTREK GUIDED MICROWAVE LEVEL TRANSMITTERS

KFS. Flap-type flow meter. Design and range of application

NGR. Guided Wave Radar Level Transmitter

Level Measurement Continuous level measurement - Radar transmitters

LST100 Ultrasonic level transmitter for upstream oil and gas

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION. Configuration. Installation

Target disk flowmeter for liquids and gases

Level Measurement With REFLEX RADAR

OPTIWAVE series. New 24 and 80 GHz FMCW radar level transmitters for liquids and solids

PiloTREK SZINTTÁVADÓK. Pulse burst radar level transmitters 5 YEARS WARRANTY

Radar. KROHNE Measure the facts. Measuring principle example 24 GHz. measuring Principle

Main features. Operation. LEVEL Transmitters

Condumax CLS21 and CLS21D

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Micro Motion Fork Viscosity Meters

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Flow Measurement SITRANS F M

Level Measurement With REFLEX RADAR

REFLEX RADAR INDICATOR

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

FOR LIQUIDS AND SOLIDS

ProcessMaster, HygienicMaster FEX300, FEX500

SITRANS T measuring instruments for temperature

Level Measurement Continuous level measurement - Radar transmitters

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Wireless Acoustic Transmitters Series XYR 5000, Model WN571 Specifications - Americas

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

OPTIWAVE 7300 C. Non-contact Radar (FMCW) Level Meter

Indumax CLS50/CLS50D. Technical Information

K-BAND RADAR FOR LIQUIDS

prosonic T FMU230, FMU231

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5

SALES SERVICE +358 (0)

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Level Measurement Continuous level measurement Radar transmitters SITRANS LR200. Overview. Configuration

Level Measurement Continuous level measurement - Radar transmitters

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

Single-Channel Safety Barriers Series 9001

Transcription:

SmartLine Non-Contact Radar Level Meter Technical Datasheet 34-VF-03-19 September 2009 Specification The Universal Radar Solution The SmartLine Non-Contact Radar Level Meter (FMCW) is for level measurement of liquids and can be used to calculate for volume assessment. SmartLine Non-Contact Radar Level Meters provide a more stable measurement than pulse radar and they are well suited for agitated process conditions. Highlights ±3 mm / ±0.04" standard accuracy Reliable measurement in difficult process conditions Operates up to a flange temperature of 200 C /(390 F) and 40 barg (580 psig) Measuring range up to 80 m (260 ft) Long antenna versions can be extended to suit nozzle length Drop antenna for corrosive liquids (with optional PTFE/PP flange plate) or where product build-up is likely Sealed drop antenna extension option for pressurized tanks Configuration software and HART DTMs included as standard Optional second current output Direct-accessible graphic touchscreen/wizard (option) Converter rotates 360 Triple barrier gas-tight protection available for working with dangerous gases (using pre-stressed fused glass) Industries Figure 1 SmartLine Non-Contact Radar Level Meter Chemicals Food & Beverage Iron, Steel & Metals Minerals & Mining Oil & Gas Petrochemicals Pulp & Paper Water & Wastewater Applications Tanks with agitators Process tanks Storage tanks 1. Optional touch screen with 4-button operation 2. 2-wire level meter 3. One converter for all applications 4. Antenna extension (for long nozzles) 5. Optional Metaglas barrier 6. Rotatable housing 7. Same housing for Ex d and Non-Ex

Page 2 Applications 1. Level measurement of liquids in storage tanks SmartLine Non-Contact Radar can measure the level of a wide range of liquid products on a large variety of installations, including LPG and LNG tanks. It does not require calibration or commissioning when installed. It can measure any liquid within the stated pressure and temperature range, and distances up to 80 m / 260 ft 2. Level measurement of liquids in process tanks SmartLine Non-Contact Radar can measure level accurately in agitated conditions, such as near to vortexes caused by agitators, and also where foam is present. 3. Open channel metering or flow SmartLine Non-Contact Radar can measure level in an open channel and convert this measurement into flow values if the characteristics of the channel are known. This solution is the high end alternative to ultrasonic and hydrostatic pressure transmitters. For installation requirements and application needs please refer to the User manual. Please refer to the User manual for details of how and where to use these products.

Page 3 4. Measurement of corrosive liquids with a drop antenna If the tank is full of obstructions such as agitators and reinforcements, Honeywell recommends installing the SmartLine Non-Contact Radar in a bypass chamber or a stilling well. For installation requirements and application needs please refer to the User manual. Please refer to the User manual for details of how and where to use these products. 5. Measurement of liquids in a bypass chamber The drop antenna option combines a relatively small radar beam for more precise measurement and a shape that avoids product build-up. If the tank contains corrosive liquids such as acids and alkaline solutions, we recommend the DN 80 / 3 drop antenna with the PTFE or PP flange plate option

Page 4 Technical Data Input Measurement principle Parameter Min. tank dimension: height 0.2 m (8") Max. measuring range K-band FMCW radar Level, distance, volume and reflectivity 80 m (260 ft) Blocking distance Antenna extension length + antenna length + 0.1 m / 4" Ouputs Output signal (Output 1) 4 20 ma HART or 3.8 20.5 ma acc. to NAMUR NE 43 Output signal (Output 2) 4 20 ma (no HART signal) or 3.8 20.5 ma acc. to NAMUR NE 43 Resolution ±3 µa Temperature drift Typically 50 ppm/k Error signal High: 22 ma; Low: 3.6 ma acc. to NAMUR NE 43 Reference conditions acc. to EN 60770 Temperature Pressure Relative air humidity 60% ±15% Reference target Accuracy (under reference conditions) +20 C ±5 C (+70 F ±10 F) 1013 mbar abs. ±20 mbar (14.69 psig ±0.29 psig) Metal plate in an anechoic chamber Resolution 1 mm (0.04 ) Repeatability ±1 mm (±0.04 ) Accuracy ±3 mm (±0.12"), when distance 10 m (33 ft); ±0.03% of measured distance, when distance > 10 m (33 ft) Beam angle - DN40 antenna 20 Beam angle - DN50 antenna 15 Beam angle - DN80 antenna 10 Beam angle - DN100 Horn antenna 8 Beam angle DN80 Horn antenna 8 Process conditions Ambient temperature Storage temperature Flange temperature Horn antenna Drop antenna (PTFE) Drop antenna (PP) Thermal shock resistance -40 +80 C (-40 +175 F) (EEx i: see supplementary operating instructions or approval certificates) Pending. -40 +85 C (-40 +185 F) -50 +200 C / -58 +390 F (Ex i: see supplementary operating instructions or approval certificates) -50 +150 C / -58 +300 F (Ex i: see supplementary operating instructions or approval certificates) -50 +100 C / -58 +210 F (Ex i: see supplementary operating instructions or approval certificates) <40 C/s / <72 F/s

Page 5 Operating pressure Drop antenna (PP) All other antennas Dielectric constant (ε r ) -1 16 bar / -14.5 232 psig; subject to process connection used and flange temperature -1 40 bar / -14.5 580 psig; subject to process connection used and flange temperature 1.5 Vibration resistance IEC 68-2-6 and EN 50178 (10...57 Hz: 0.075 mm (57...150 Hz:1 g) Protection category IP 66/67 equivalent to NEMA 6-6X Material Housing Wetted parts, including antenna Process fitting Gaskets Aluminium, Stainless steel (not FM/CSA) Stainless steel 1.4404 (316L); Hastelloy C-22 (2.4602) PTFE; PP (a PP or PTFE flange plate is also available) Stainless steel 1.4404 (316L); Hastelloy C-22 (2.4602) FKM/FPM -40 +200 C (-40 +390 F); Kalrez 6375-20 +200 C (-5 +390 F) EPDM (-50 C +150 C / -58 F +300 F) Feedthrough PEI/standard -40...+200 C (-40...+390 F); Metaglas -30...+200 C (-20...+390 F) Weather protection (Option) Stainless steel 1.4301 (304) Process Connections Thread G 1½"; NPT 1½" Flange Electrical Connections Instrument terminal 1 - Non-Ex / EEx i versions 14 30 VDC (1) Instrument terminal 1 - EEx d version 20 36 VDC (1) Instrument terminal 2 - Non-Ex/ EEx i/ EEx d versions 10 30 VDC (2) DN40 150 (PN40 / PN16); 1½" 8" (150 lb / 300 lb); 10K (40 100A) Cable entry (x2) M20x1.5; ½" NPT G ½" (not for FM- and CSA- approved devices); M25x1.5 (For stainless steel housing only) Cable tightening capacity 0.5 1.5 mm ² (0.02 0.06 ) Human Machine Interface Display Operating languages 9 lines, 160 x 160 pixels in 8-step greyscale with 4-button keypad English, German, French, Italian, Spanish, Portuguese, Japanese, Chinese (Mandarin) and Russian

Page 6 Approvals ATEX ATEX II G 1, 1/2, 2 Ex ia IIC T6...T3; ATEX II D 1, 1/2, 2 Ex iad 20 or Ex iad 20/21 or Ex iad 21 IP6X T65 C...T90 C; ATEX II G 1/2, 2 Ex d [ia] IIC T6...T3; ATEX II D 1, 1/2, 2 Ex td[iad] A21/20 or Ex td[iad] A21 IP6X T65 C...T90 C; ATEX II G 3 Ex na IIC T6 T3 IECEx (approval pending) Zone 0 Ex ia IIC T6 T3; Ex iad 20 IP6X T65 C T 90 C FM or CSA (approvals pending) NEC 500/ CEC Cl. I, Div. 1, Gr. ABCD (IS); Cl. I, Div. 1, Gr. ABCD (FM only ) (XP); (FM approval pending) Cl. I, Div. 2, Gr. ABCD (XP/NI); Cl. II, Div. 1, Gr. EFG; Cl. III (FM only ) (XP); (FM approval pending) NEC 505/ CEC NEPSI (approval pending) Other approvals Cl. II Div. 1, Gr. EFG; Cl. III (IS); Cl. II/III, Div. 2, Gr. FG (XP/NI) Cl. I, Zone 0 AEx ia Gr. IIC (CSA: Ex ia) (IS); (CSA approval pending) Cl. I, Zone 1 AEx d [ia] Gr. IIC (XP); Cl. I, Zone 2, AEx na [ia], Gr. IIC (CSA: Ex na [ia]) (IS) (CSA approval pending) Ex dia IIC T3 T6; Ex ia IIC T3 T6 Gosstandard; PESO (India) (approvals pending) Options and Accessories Options Integrated LCD display with sun cover; ( -20...+60 C/ - 4...+140 F);(5) 2nd current output; Antenna purging system (3) Accessories Weather protection; Antenna extensions 1 min./max. value for an output of 22 ma at the terminal 2 min./max. value for an output of 22 ma at the terminal (additional power supply needed output relay) 3 supplied with NPTF ¼ connection 5 if the temperature is not in these limits, the display switches off

Page 7 Dimensions and Weight Note: Cable glands are delivered on demand with non-ex. A weather protection cover is delivered on demand with all devices Dimensions in mm (inches) and kg (lbs) Housing front view Housing front view Dimensions mm (inches) a b c d e f g Weight kg (lbs) Housing 180 (7.1) 122 (4.8) 158.5 (6.2) 182 (1) (7.2) 167 (6.7) 277 (10.9) 155 (6.10) 3.3 (7.3) 1 if fitted with cable glands

Page 8 Dimensions and Weight in mm (inches) and kg (lbs) Weather protection back view Weather protection left side Dimensions mm (inches) a b c d Weight kg (lbs) Weather protection 208 (8.2) 231.5 (9.1) 268 (1) (10.6) 66 (2.6) 2.9 (6.4) 1 radius Dimensions and Weight in mm (inches) and kg (lbs) Antenna with thread connection Dimensions mm (inches) a b c d e f g h i Weight kg (lbs) DN50 Standard 182 (1) (7.2) 167 (6.5) 190 (7.5) 278 (11.0) 355 (14.0) 88 (3.5) 44.5 (1.8) 77 (3.0) 43 (2) (1.7) 6 (13.2) 1 if fitted with standard cable glands 2 1½" NPT or G process connections available

Page 9 Dimensions and Weight in mm (inches) and kg (lbs) DN40/50 long antenna Dimensions mm (inches) A b c d e f g h i Weight kg (lbs) DN40 182 (1) 167 190 305 590 115 50 (2) 95 (3) 39 9 long (7.2) (6.5) (7.5) (12.0) (23.2) (4.5) (2.0) (3.7) (1.5) (19.8) DN50 182 (1) 167 190 305 411 115 50 (2) 106 (3) 43 9 long (7.2) (6.5) (7.5) (12.0) (16.2) (4.5) (2.0) (4.2) (1.7) (17.8) 1 if fitted with standard cable glands 2 antenna flushing system delivered on demand (NPTF ¼ connection) 3 additional antenna extensions of 105 mm (4.1 ) length are available

Page 10 Dimensions and Weight in mm (inches) and kg (lbs) DN80 long antenna Dimensions mm (inches) a b c d e f g h i Weight kg (lbs) DN80 182 (1) 167 190 305 523 115 50 (2) 216 (3) 75 12 long (7.2) (6.5) (7.5) (12.0) (20.5) (4.5) (2.0) (8.5) (3.0) (26.5) 1 if fitted with standard cable glands 2 antenna flushing system delivered on demand (NPTF ¼ connection) 3 additional antenna extensions of 105 mm (4.1 ) length are available

Page 11 DN100/4 long horn antenna Dimensions mm (inches) a b c d e f g h i Weight kg (lbs) DN100 182 (1) 167 190 305 523 115 71.5 (2) 284 (3) 95 19 long (7.2) (6.5) (7.5) (12.0) (20.5) (4.5) (2.8) (11.2) (3.7) (42) 1 if fitted with standard cable glands 2 antenna purging system delivered on demand (NPTF ¼ connection) 3 additional antenna extensions of 105 mm (4.1 ) length are available

Page 12 DN80/3 drop antenna, without plate DN80/3 drop antenna, with plate Dimensions mm (inches) a b c d e f g h i Weight kg (lbs) DN80 3 182 (1) (7.2) 167 (6.5) 193 (7.6) 276 (2) (10.9) 382 (15.0) 83 (3) (3.3) 71.5 (2.8) 106 (4) (4.2) 74 (2.9) 11 (24.3) 1 if fitted with standard cable glands 2 11.1,with the PP/PTFE flange plate option 3 3.5, with the PP/PTFE flange plate option 4 4 with the PP/PTFE flange plate option. Additional antenna extensions of 4.1 length are available for drop antenna without the flange plate option.

Page 13 Antenna selection: liquid applications The graphs below show which antenna to select for the application based on: D, the measuring range, ε r is the dielectric constant of the product being measured and the application. 1 Distance, D [m] 2 Distance, D [ft] 3 Dielectric constant (ε r ) range for storage/agitator applications 4 Dielectric constant (ε r ) range for process/agitator applications 5 DN 80 antenna in a still well 6 DN 80 antenna with or without a still well 7 DN40, DN 50, DN 80 antenna with or without a still well

Page 14 Antenna selection: solid applications D, the measuring range, εr, is the dielectric constant of the product being measured and the application. 1 Distance, D [m] 2 Distance, D [ft] 3 Dielectric constant (εr) 4 On request 5 DN 80/3 or DN 100/4 antenna

Page 15 This page has been intentionally left blank

Page 16 Ordering Information Contact your nearest Honeywell sales office, or In the U.S.: Honeywell Process Solutions Honeywell International Inc 2500 West Union Hills Drive Phoenix, AZ 85027 1-800-343-0228 In Europe and Africa: Honeywell S. A. Avenue du Bourget 1 1140 Brussels, Belgium In Asia: Honeywell Asia Pacific Inc. Honeywell Building, 17 Changi Business Park Central 1 Singapore 486073 Republic of Singapore In Canada: The Honeywell Centre 155 Gordon Baker Rd. North York, Ontario M2H 3N7 1-800-461-0013 In Eastern Europe: Honeywell Praha, s.r.o. Budejovicka 1 140 21 Prague 4, Czech Republic In the Pacific: Honeywell Pty Ltd. 5 Thomas Holt Drive North Ryde NSW Australia 2113 (61 2) 9353 7000 In Latin America: Honeywell Inc. 480 Sawgrass Corporate Parkway, Suite 200 Sunrise, FL 33325 (954) 845-2600 In the Middle East: Honeywell Middle East Ltd. Khalifa Street, Sheikh Faisal Building Abu Dhabi, U. A. E. In Japan: Honeywell K.K. 14-6 Shibaura 1-chrome Minato-ku, Tokyo, Japan 105-0023 Or, visit Honeywell on the World Wide Web at: http://www.honeywell.com/ps Specifications are subject to change without notice.