Simultaneous measurement of two different-color ultrashort pulses on a single shot

Similar documents
GRENOUILLE.

Extremely simple device for measuring 1.5-µm ultrashort laser pulses

The Measurement of Ultrashort Laser Pulses

Measuring extremely complex pulses with timebandwidth products exceeding 65,000 using multiple-delay crossed-beam spectral interferometry

Real-time inversion of polarization gate frequency-resolved optical gating spectrograms

Ultrafast Optical Physics II (SoSe 2017) Lecture 9, June 16

Highly simplified device for measuring the intensity and phase of picosecond pulses

Determining error bars in measurements of ultrashort laser pulses

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Chad A. Husko 1,, Sylvain Combrié 2, Pierre Colman 2, Jiangjun Zheng 1, Alfredo De Rossi 2, Chee Wei Wong 1,

High-Energy 6.2-fs Pulses for Attosecond Pulse Generation

Optimization of supercontinuum generation in photonic crystal fibers for pulse compression

Modified Spectrum Auto-Interferometric Correlation. (MOSAIC) for Single Shot Pulse Characterization

FROG. In order to measure an event in time, you need a shorter one. So how do you measure the shortest one?

Ultrafast pulse characterization using XPM in silicon

14. Measuring Ultrashort Laser Pulses I: Autocorrelation

GA 30460, USA. Corresponding author

High Energy Non - Collinear OPA

Spider Pulse Characterization

Increased-bandwidth in ultrashort-pulse measurement using an angle-dithered nonlinear-optical crystal

Remote characterization and dispersion compensation of amplified shaped femtosecond pulses using MIIPS

Crossed-beam spectral interferometry: a simple, high-spectral-resolution method for completely characterizing complex ultrashort pulses in real time

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

How to build an Er:fiber femtosecond laser

Dispersion measurement in optical fibres over the entire spectral range from 1.1 mm to 1.7 mm

Figure1. To construct a light pulse, the electric component of the plane wave should be multiplied with a bell shaped function.

Propagation, Dispersion and Measurement of sub-10 fs Pulses

A CW seeded femtosecond optical parametric amplifier

Pulse stretching and compressing using grating pairs

Pulse Shaping Application Note

ULTRA-BROADBAND PHASE-MATCHING ULTRASHORT- LASER-PULSE MEASUREMENT TECHNIQUES

Title: Laser marking with graded contrast micro crack inside transparent material using UV ns pulse

Fundamental Optics ULTRAFAST THEORY ( ) = ( ) ( q) FUNDAMENTAL OPTICS. q q = ( A150 Ultrafast Theory

Time-Resolved Optical Gating Based on Dispersive Propagation: A New Method to Characterize Optical Pulses

THE RECENT development of techniques for measuring

Fabrication of Photorefractive Grating With 800 nm Femtosecond Lasers in Fe: LiNbO 3 and Rh:BaTiO 3 Crystals

Measuring Ultrashort Laser Pulses Using Frequency-Resolved Optical Gating in Conjunction with Genetic and Iterative Algorithms

Ultrafast instrumentation (No Alignment!)

Quantifying noise in ultrafast laser sources and its effect on nonlinear applications

Characterization of Chirped volume bragg grating (CVBG)

Case Study: Simplifying Access to High Energy sub-5-fs Pulses

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

Up-conversion Time Microscope Demonstrates 103x Magnification of an Ultrafast Waveforms with 300 fs Resolution. C. V. Bennett B. H.

THE GENERATION and characterization of ultrafast

Detection of chemicals at a standoff >10 m distance based on singlebeam coherent anti-stokes Raman scattering

THE GENERATION of ultrashort laser pulses with durations

Spectral Phase Modulation and chirped pulse amplification in High Gain Harmonic Generation

Dispersion and Ultrashort Pulses II

Fiber-optic Michelson Interferometer Sensor Fabricated by Femtosecond Lasers

pulsecheck The Modular Autocorrelator

TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES

Applied Physics B Lasers and Optics. m. hirasawa 1,3, n. nakagawa 1,3 k. yamamoto 1,3 r. morita 1,3 h. shigekawa 2,3 m.

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

Designing for Femtosecond Pulses

High-Power Femtosecond Lasers

APE Autocorrelator Product Family

SUPPLEMENTARY INFORMATION

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

Second-harmonic generation from regeneratively amplified femtosecond laser pulses in BBO and LBO crystals

High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology

SUPPLEMENTARY INFORMATION DOI: /NPHOTON

Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin

Phase-sensitive high-speed THz imaging

SIMPLIFIED SCHEME FOR UV TIME PULSE SHAPING. Abstract

Soliton stability conditions in actively modelocked inhomogeneously broadened lasers

Generation and Control of Ultrashort Supercontinuum Pulses

Fast Raman Spectral Imaging Using Chirped Femtosecond Lasers

101 W of average green beam from diode-side-pumped Nd:YAG/LBO-based system in a relay imaged cavity

Infrared broadband 50%-50% beam splitters for s- polarized light

Enhanced bandwidth of supercontinuum generated in microstructured fibers

Coherent temporal imaging with analog timebandwidth

Fiber Laser Chirped Pulse Amplifier

Optical transfer function shaping and depth of focus by using a phase only filter

Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

Continuum White Light Generation. WhiteLase: High Power Ultrabroadband

Nonlinear Optics (WiSe 2015/16) Lecture 9: December 11, 2015

PERFORMANCE OF PHOTODIGM S DBR SEMICONDUCTOR LASERS FOR PICOSECOND AND NANOSECOND PULSING APPLICATIONS

Low threshold power density for the generation of frequency up-converted pulses in bismuth glass by two crossing chirped femtosecond pulses

High-Conversion-Efficiency Optical Parametric Chirped-Pulse Amplification System Using Spatiotemporally Shaped Pump Pulses

Temporal coherence characteristics of a superluminescent diode system with an optical feedback mechanism

Spatial distribution clamping of discrete spatial solitons due to three photon absorption in AlGaAs waveguide arrays

Progress in ultrafast Cr:ZnSe Lasers. Evgueni Slobodtchikov, Peter Moulton

Pulse compression with supercontinuum generation in microstructure fibers

FULLY PROGRAMMABLE TWO-DIMENSIONAL ULTRA-COMPLEX BROADBAND FINE-RESOLUTION PULSE SHAPING. A Thesis. Submitted to the Faculty.

A broadband achromatic metalens for focusing and imaging in the visible

High Power and Energy Femtosecond Lasers

Ultrafast Surface-Enhanced Raman Probing of the Role of Hot Electrons in Plasmon-Driven Chemistry. Supporting Information

VELA PHOTOINJECTOR LASER. E.W. Snedden, Lasers and Diagnostics Group

Rogério Nogueira Instituto de Telecomunicações Pólo de Aveiro Departamento de Física Universidade de Aveiro

Directly Chirped Laser Source for Chirped Pulse Amplification

Department of Electrical Engineering and Computer Science

7 CHAPTER 7: REFRACTIVE INDEX MEASUREMENTS WITH COMMON PATH PHASE SENSITIVE FDOCT SETUP

Outline. Motivation Experimental Set-Up Theory behind the set-up Results Acknowledgements

Bias errors in PIV: the pixel locking effect revisited.

G. Norris* & G. McConnell

Generation of µj multicolor femtosecond laser pulses using cascaded four-wave mixing

Supplementary Materials for

some aspects of Optical Coherence Tomography

CHAPTER 7. Waveguide writing in optimal conditions. 7.1 Introduction

Improvement of terahertz imaging with a dynamic subtraction technique

Transcription:

Wong et al. Vol. 29, No. 8 / August 2012 / J. Opt. Soc. Am. B 1889 Simultaneous measurement of two different-color ultrashort pulses on a single shot Tsz Chun Wong,* Justin Ratner, and Rick Trebino School of Physics, Georgia Institute of Technology, 837 State Street, Atlanta, Georgia 30332, USA *Corresponding author: jeff.wong@gatech.edu Received April 16, 2012; accepted May 30, 2012; posted June 7, 2012 (Doc. ID 166837); published July 3, 2012 We experimentally demonstrate the ability of double blind frequency-resolved optical gating to simultaneously measure two independent pulses at very different wavelengths on a single shot. Our device uses polarization-gate geometry, allowing pulses at any two wavelengths and unlimited operating bandwidth. The retrieval algorithm is robust and is capable of ignoring most forms of noise in the measured spectrograms. 2012 Optical Society of America OCIS codes: 320.0320, 320.7100. 1. INTRODUCTION Measuring the complete intensity and phase of ultrashort laser pulses is important in order to understand experiments and applications that use them. Techniques such as frequencyresolved optical gating (FROG) [1,2] and its simplified version GRENOUILLE [3 5] have been developed in the past few decades to make such measurements. In modern ultrafast-optical experiments, however, there is often the need to measure two unrelated unknown pulses simultaneously. For example, in pump-probe experiments, used to characterize the material properties, both the pump and probe pulses must be measured. Also, applications involving nonlinear-optical processes, such as continuum generation in optical fiber [6 8], which generate pulses at a different wavelength, require measuring both the input and output pulses. Thus, a measurement technique capable of simultaneously measuring two unknown pulses simultaneously would be useful. Indeed, a technique that can measure two pulses of different colors and do so on a single shot would be even more helpful, especially for the above-mentioned applications. Various methods had been proposed to solve the two-pulse measurement problem, including blind FROG [9 11] and VAMPIRE [12], but they require additional information, such as the spectra of the pulses, to completely determine the unknown pulses. We recently demonstrated a technique called double blind FROG (DB FROG) using the polarization-gate (PG) geometry, which allows two unknown pulses to be measured simultaneously on a single shot without prior knowledge of the pulse spectra [13]. And we used it to measure pulse pairs with the same center wavelength, for which it worked well. Theoretically, this device should be capable of measuring more complex pulse pairs and pulse pairs with different center wavelengths and bandwidths. Indeed, here, we demonstrate that it can measure a complex pulse pair and pulse pairs with the very different center wavelengths of 400 and 800 nm. 2. BACKGROUND DB FROG relies on the idea that, in any two-beam geometry, as one pulse gates the other, at the same time, the other also gates the one. Extending the idea behind other FROG variants to measure two pulses, signal light is spectrally resolved in both arms and two traces are generated in each measurement, one trace for each arm. In the PG geometry, the two unknown pulses gate each other in a χ 3 nonlinear medium (fused silica in our setup). It requires that each pulse passes through a pair of crossed polarizers (see Fig. 1). The polarizations of the pulse pair are set 45 relative to each other, for example with pulse 1 at 0 and pulse 2 at 45. It is well known that, when two pulses with 45 relative polarization interact in a χ 3 medium, each induces birefringence by the third-order nonlinear polarization and so will cause polarization rotation in the other. The pulses with rotated polarization then pass through the crossed polarizer pairs and are spectrally resolved to generate the FROG traces. Single-shot operation is achieved by crossing them at an angle, which maps the delay between the two pulses onto transverse position in the nonlinear medium. Implementation of DB FROG in the PG geometry inherits the advantages of standard PG FROG. The most important one is that the third-order nonlinear-optical process involved in polarization rotation is always phase-matched for pulses with any wavelengths, bandwidths, and crossing angles. This can be seen from the nonlinear polarizations, P NL i, given by P NL 1 χ 3 E 2 E 2 E 1; (1) P NL 2 χ 3 E 1 E 1 E 2; (2) where E 1 and E 2 are the electric fields of pulse 1 and pulse 2 respectively, and denotes the complex conjugate. We observe that P NL 1 is proportional to je 2 j 2 E 1, which implies that the k-vectors from E 2 (the gate for E 1 ) will always cancel 0740-3224/12/081889-05$15.00/0 2012 Optical Society of America

1890 J. Opt. Soc. Am. B / Vol. 29, No. 8 / August 2012 Wong et al. Fig. 1. (Color online) Schematic of single-shot DB PG FROG for measuring an unknown pulse pair. out, guaranteeing phase-matching. The same analysis applied to P NL 2 yields the same result. This convenient property of the PG geometry holds for beams of any color and bandwidth, allowing DB PG FROG to measure a pulse pair with very different center wavelengths and extremely large bandwidths. On the other hand, the PG geometry requires high-quality polarizers with extinction coefficients no less than 10 5. Fortunately, commercially available laser-grade calcite polarizers offer sufficiently high extinction coefficients. While they are usually thick, and therefore introduce dispersion and distortion to the pulse, this is usually not a problem, and only the polarizer before the nonlinear medium needs to be considered. After the pulse is retrieved, it is easy to numerically backpropagate the pulse to eliminate the effect of the polarizer or any other optics in the beams to obtain the original input pulses. This is possible because the full intensity and phase vs. time and frequency are retrieved from a FROG or DB FROG measurement. The measured DB FROG trace is essentially a crosscorrelation FROG (XFROG) trace [14]. The DB FROG retrieval algorithm is employed to retrieve the unknown pulse pair. It is modified from the standard XFROG algorithm and runs between the two XFROG traces alternatively (see Fig. 2). In brief, the algorithm starts with random guesses for both pulses and assumes one of them is the correct gate pulse (even when is not) to retrieve the other. Once the retrieval is close to complete for the one, it switches to retrieve the other one. The cycle repeats until the retrieved traces converge to the measured ones. The convergence is defined by the G error (the root-mean-square difference between the measured and retrieved traces), like other FROG techniques [1]. More details Fig. 2. (Color online) Pulse retrieval algorithm in DB PG FROG. Fig. 3. (Color online) Schematic of single-shot DB PG FROG for measuring an unknown pulse pair at different wavelengths (400 and 800 nm in our experiment). of how DB FROG works and its algorithm can be found in our previous work [13]. 3. EXPERIMENTAL SETUP We use a 70 fs pulse with center wavelength of 800 nm at a 1 khz repetition rate from a Ti:Sapphire regenerative amplifier (Coherent Legend Elite). We use the setup depicted in Fig. 1, but modify it to measure a pulse pair at the wavelengths of 400 and 800 nm, respectively. The 400 nm pulse was generated by second harmonic generation of 800 nm using a 1 mm thick BBO crystal with type I phase matching. The beams had a diameter of 7 mm and crossed in a 250 μm fused silica window at an angle of 7 to map delay onto transverse position at the crystal and hence achieve single-shot operation by imaging the crystal onto a camera. As in our previous work, we implemented the PG geometry in our setup, in which each arm had a pair of crossed polarizers. The blue arm (400 nm) of the device used a pair of crossed polarizers at 0 and 90, while the red arm (800 nm) used a 45 and 45 pair. In our two-color DB PG FROG setup, instead of using a single lens to focus the beams onto the fused silica window for both arms, individual lenses for each beam were used to avoid chromatic aberration (see Fig. 3). Focusing lenses with focal lengths of 150 mm and 200 mm were used in the blue and red arms, respectively. The same focal lengths were used as the collimating lenses for the same reason. The diffraction grating in the blue arm had 1200 lines mm and the one in the red arm had 600 lines mm. 4. RESULTS We first present the measurement of a pair of complex samewavelength pulses with a time-bandwidth product (TBP) of 4 using the experimental setup shown in Fig. 1 in order to demonstrate that DB FROG can measure more complex pulses than previously considered. One of the pulses was a chirped pulse train generated by passing a pulse train generated from an etalon through a 2 cm long SF11 glass block. The other was a chirped double pulse created by passing a double pulse generated from a Michelson interferometer through a 4 cm long SF11 glass block. Both of the pulses exhibited characteristics of chirped-pulse beating. The pulses had pulse energies of 120 μj. In our experimental setup, simple pulses like flat-phase Gaussian pulses required 50 μj to generate a good signal to noise ratio, while more complex pulses required more energy to do so. The resulting DB PG FROG measurements of these two pulses are shown in Figs. 4 and 5. The G-errors of both

Wong et al. Vol. 29, No. 8 / August 2012 / J. Opt. Soc. Am. B 1891 Fig. 4. (Color online) (a) Measured trace 1 for a chirped pulse train; (b) Retrieved trace 1 with a FROG error of 0.81%; (c) Retrieved pulse intensity and phase in temporal domain showing structures from arms were about 0.8% for the 512 512 arrays. Distortion in the temporal domain is observed in both arms, a clear indication of chirped-pulse beating, as expected. Independent measurements of the spectrum made with a spectrometer (Ocean Optics, Model HR-4000) for both arms are plotted as black dashed lines. The spectral peak locations match very well between the DB PG FROG and spectrometer measurements. The good agreement between the spectra and our knowledge of the pulse characteristics based on its generation apparatus confirm that our retrieved pulses are correct. We then switched the experimental setup to the one shown in Fig. 3 for a two-color measurement. A pair of simple pulses with center wavelengths of 400 and 800 nm were used to test the setup. The red pulse was not compressed to its shortest possible pulse width in this case and instead allowed to remain chirped. This is because we used pre-chirping of the 800 nm pulse to improve the SHG efficiency. The pulse energies used were 105 μj for the blue and 70 μj for the red. The Fig. 6. (Color online) (a) Measured trace for a simple pulse at 400 nm; (b) Retrieved trace with a FROG error of 0.32%; (c) Retrieved pulse intensity and phase in temporal domain showing structures from measured and retrieved DB PG FROG traces are shown in Figs. 6 and 7. The G errors were 0.32% and 0.30% for the blue and red pulses, respectively. Independent measurements made by GRENOUILLE (Swamp Optics, Model 8 50), plotted in black dashed lines, show excellent agreement with the intensity and phase retrieved from DB PG FROG. The temporal full width at half maxima of the 800 nm pulse were 73.2 and 73.5 fs, as measured by GRENOUILLE and DB PG FROG, respectively. The spectrum at 400 nm, measured by the spectrometer, also agrees well with the spectral intensity retrieved by the DB PG FROG. Both pulses in this measurement have TBPs of about 1.1. Next, we generated a well-separated double pulse at 800 nm using a Michelson interferometer and allowed the 400 nm pulse to remain simple. The DB PG FROG measurement is shown in Figs. 8 and 9. The G errors were 0.83% for the blue pulse and 0.52% for the red one. Independent measurements of the spectrum were made for both pulses shown in Fig. 5. (Color online) (a) Measured trace 2 for a chirped double pulse; (b) Retrieved trace 2 with a FROG error of 0.74%; (c) Retrieved pulse intensity and phase in temporal domain showing structures from Fig. 7. (Color online) (a) Measured trace for a simple pulse at 800 nm; (b) Retrieved trace with a FROG error of 0.30%; (c) Retrieved pulse intensity and phase in time compared with an independent GRENOUILLE measurement; (d) The measured spectrum and the spectral phase compared with those made using a GRENOUILLE.

1892 J. Opt. Soc. Am. B / Vol. 29, No. 8 / August 2012 Wong et al. Fig. 8. (Color online) (a) Measured DB PG FROG trace for a simple pulse at 400 nm; (b) Retrieved trace with a FROG error of 0.83%; (c) Retrieved pulse intensity and phase in temporal domain; (d) The measured spectrum and the spectral phase compared with a measurement made by a spectrometer. black-dashed line. The fringes in the 800 nm pulse spectrum measured by a spectrometer and DB PG FROG overlap very well. The measured average fringe separation in the 800 nm pulse measured by the spectrometer and DB PG FROG were 3.82 and 3.91 nm, respectively. Since the spectral fringes are created by a double pulse, the pulse separation can be easily calculated from the fringes spacing with known center wavelength. Using the average fringe spacing measured by the spectrometer, the calculated pulse separation was 558 fs. The pulse separation retrieved by DB PG FROG was 547 fs, consistent with our calculation. The TBP of the well-separated double pulse at 800 nm was about 6.2 and that of the simple pulse at 400 nm was about 1.1. 5. DISCUSSION Our results confirm the ability of DB PG FROG to fairly accurately measure even complex and/or very-different-color pulses. Not every detail in every pulse achieved perfect agreement with the independently measured quantities by the GRENOUILLE or the spectrometer, but laser amplifier systems are unstable and experience shot-to-shot fluctuations and long-term drifts. Specifically, even though the fringe separation was consistent from shot to shot, the envelope of the spectrum tended to vary. Figure 10 shows four spectra measured within a short period of time. Fluctuations were observed, indicating slight instability of our laser amplifier system. Because simultaneous measurements of the same pulse by DB PG FROG and also by a spectrometer or GRENOUILLE are difficult, we did not attempt to do so, which could be responsible for the observed minor discrepancies, such as why the fringe separation in Fig. 9 matches well, but some of the peaks have different intensity. In addition to the drift of the laser system, the imperfect spatial profile of our beam, especially the 400 nm beam, may contribute to the discrepancy. The measurement made by the spectrometer only samples a small portion of the beam and thus the spatial profile-effect is not prominent. Another possible reason for the noticeable discrepancies is that higher frequency fringes were observed in the measured traces but not in the retrieved ones. One of measured traces with higher frequency fringes is shown in Fig. 11. The average fringe spacings were found to be 0.21 and 0.80 nm for the 400 nm arm and 800 nm arm, respectively. We believe the higher frequency fringes are the result of multiple reflections from the 250 μm fused silica window. The fringes generated at wavelength, λ, from a window with thickness, L, and refractive index n λ can be calculated by Eq. 3: Δλ λ 2 2n λ L : (3) Our calculation shows that the fringe spacings due to the fused silica window were 0.20 nm at 400 nm and 0.83 nm at 800 nm. The results are consistent (within 5%) with the average fringe spacings measured from the traces. We would like to point out that, despite the presence of the non-pulse-related (and hence unphysical) higher frequency fringes, the retrieval algorithm is able to retrieve the pulse and essentially ignore Fig. 9. (Color online) (a) Measured DB PG FROG trace for a well separated double pulse at 800 nm; (b) Retrieved trace with a FROG error of 0.52%; (c) Retrieved pulse intensity and phase in temporal domain; (d) The measured spectrum and the spectral phase compared with a measurement made by a spectrometer. Fig. 10. (Color online) Four spectra of the same pulse measured at different times. The spectra have same fringes separation but a slightly different envelope.

Wong et al. Vol. 29, No. 8 / August 2012 / J. Opt. Soc. Am. B 1893 Fig. 11. (Color online) Higher resolution plot of the DB PG FROG trace captured in the 400 nm arm showing the higher frequency fringe artifact due to etalon effects in the nonlinear medium. them. Thus, the retrieved traces are free of the higher frequency fringes, and the retrieved pulses do not suffer any ill effects from their presence. So we have not attempted to remove them, although future experiments could use an anti-reflection-coated nonlinear medium if the reduced damage threshold that results is acceptable. 6. CONCLUSION We have demonstrated the use of DB PG FROG to measure a more complex pulse pair, both with TBPs of about 4. We have also demonstrated its ability to measure two unknown different-color pulses with center wavelengths of 400 and 800 nm. We find the retrieval algorithm to be robust and able to ignore unphysical distortions of the trace and still return the correct pulses. The unlimited bandwidth of DB PG FROG should make it extremely versatile in single-shot pulse measurements. In future work, we will measure even more complex pulse with broader bandwidths and higher TBPs. ACKNOWLEDGEMENTS The authors acknowledge support from the National Science Foundation, Grant #ECCS-1028825, and the Georgia Research Alliance. They also thank Dongjoo Lee of Swamp Optics for helpful discussions and technical support in the experiments. REFERENCES 1. R. Trebino, Frequency-Resolved Optical Gating: The Measurement of Ultrashort Laser Pulses (Kluwer Academic, 2002). 2. S. Akturk, X. Gu, M. Kimmel, and R. Trebino, FROG for measuring extremely short and extremely long pulses, 10 12 Photon. Int. (2006). 3. P. O Shea, M. Kimmel, X. Gu, and R. Trebino, Highly simplified device for ultrashort-pulse measurement, Opt. Lett. 26, 932 934 (2001). 4. S. Akturk, M. Kimmel, P. O Shea, and R. Trebino, Extremely simple device for measuring 20 fs pulses, Opt. Lett. 29, 1025 1027 (2004). 5. P. Bowlan and R. Trebino, Complete single-shot measurement of arbitrary nanosecond laser pulses in time, Opt. Express 19, 1367 1377 (2011). 6. X. Gu, M. W. Kimmel, E. Zeek, P. O Shea, R. Trebino, and R. S. Windeler, Cross-correlation frequency-resolved-opticalgating measurements of ultrabroadband continuum from microstructure optical fiber, in Ultrafast Phenomena XIII, Thirteenth International Conference on Ultrafast Phenomena, Technical Digest (Optical Society of America, 2002), pp. 277 278. 7. Q. Cao, X. Gu, E. Zeek, M. Kimmel, R. Trebino, J. Dudley, and R. S. Windeler, Measurement of the intensity and phase of supercontinuum from an 8 mm-long microstructure fiber, Appl. Phys. B 77, 239 244 (2003). 8. D. Lee, P. Gabolde, and R. Trebino, Toward single-shot measurement of broadband ultrafast continuum, J. Opt. Soc. Am. B 25, A25 A33 (2008). 9. K. W. DeLong, R. Trebino, and W. E. White, Simultaneous recovery of two ultrashort laser pulses from a single spectrogram, J. Opt. Soc. Am. B 12, 2463 2466 (1995). 10. J. J. Field, C. G. Durfee, and J. A. Squier, Blind frequencyresolved optical-gating pulse characterization for quantitative differential multiphoton microscopy, Opt. Lett. 35, 3369 3371 (2010). 11. D. J. Kane, G. Rodriguez, A. J. Taylor, and T. S. Clement, Simultaneous measurement of two ultrashort laser pulses from a single spectrogram in a single shot, J. Opt. Soc. Am. B 14, 935 943 (1997). 12. S. Birger and S. Heinrich, A method for unique phase retrieval of ultrafast optical fields, Meas. Sci. Technol. 20, 015303 (2009). 13. T. C. Wong, J. Ratner, V. Chauhan, J. Cohen, P. M. Vaughan, L. Xu, A. Consoli, and R. Trebino, Simultaneously measuring two ultrashort laser pulses on a single-shot using double-blind frequency-resolved optical gating, J. Opt. Soc. Am. B 29, 1237 1244 (2012). 14. S. Linden, H. Giessen, and J. Kuhl, XFROG a new method for amplitude and phase characterization of weak ultrashort pulses, Phys. Status Solidi B 206, 119 124 (1998).