ROSEMOUNT TANK GAUGING SYSTEM SAFETY EFFICIENCY ACCURACY Always ready for your next challenge
Welcome to a new era in tank gauging Big words, we know. But Rosemount Tank Gauging System really takes tank gauging to another level. You will be better equipped to handle the ever-increasing demands on efficiency, safety and accuracy. You get a complete and flexible tank gauging system, giving you total freedom. Ready to improve safety With no moving parts, radar technology is fundamentally reliable. But Rosemount Tank Gauging System takes safety further than ever before. The gauge with a 2-in-1 feature can, for example, be delivered to meet SIL 3 requirements for overfill prevention. Ready to improve efficiency The Rosemount Tank Gauging System is based on the open industry standard Foundation fieldbus. This makes it easy to install exactly the devices you need today as well as adding or replacing units tomorrow. Having access to reliable and accurate tank content information in real time is key to high plant efficiency, as your operators can handle even more tanks, fill the tanks higher and better utilize the storage capacity. Rosemount Tank Gauging System takes you to top efficiency and lets you stay there. Ready to improve accuracy For decades, Rosemount radar tank gauges have been the obvious choice when precision is critical. The gauge builds upon this legacy by offering level measurement accuracy of ±0.5 mm (0.02 in.). But even if accuracy is important, the need can vary. That is why we include gauging solutions all the way from operational control only, to custody transfer performance with full inventory management functionality. Radar Level Gauge Non-contact radar gauge for applications with high requirements on level measurement and overfill prevention. Gateway Connects wireless devices on the tanks with the host system. TankMaster Tank gauging software for inventory and custody transfer functions. Calculations can be based on API, ISO and other major industry standards. Future-proof design New level of safety Renowned accuracy
Gateway 2230 Alternative Connection to DCS 5400 2240S 3051S Whatever your next step, you will be ready Tank Hub with LPG/LNG antenna ressurized or cryogenic P liquefied gas Practically unlimited Thanks to the use of an open commun ications standard (Foundation fieldbus), Rosemount Tank Gauging System lets you combine gauging devices freely within your system. The bus-powered, two-wired Tankbus is self-configured and intrinsically safe allowing cabling without conduits which means lower installation cost. Long- trong echo even under S surface boiling conditions distance communication to the control room can be made via our TRL2 fieldbus or other major fieldbus standards. data transmission is also an option. This is especially valuable when it is necessary to cross roads or when distance or ground conditions make cabling expensive. Upgrade gradually There are numerous tank farms with gauging based on older technology, even in fairly recent installations. But don t worry. Rosemount Tank Gauging System can emulate gauges from other manufacturers. This means you can add Rosemount radar level gauges to your existing system. with horn antenna Fixed roof tanks without still-pipe 200 400 mm (8-16 in.) nozzles Oil products and chemicals except for sticky liquids 2230 Graphical Radar with still-pipe array antenna Best choice in tanks without still-pipe New or existing still-pipes Demanding environments with sticky or condensing liquids such as asphalt Crude oil tanks with floating roofs Gasoline tanks with/without inner floating roofs with Spot 2180 Field Bus Modem 2240S Multi 5300 Tank Hub Input 5300T Radar 5400T Radar with Spot Level Gauge 3051S 2230 Graphical Average 5400/5300 Field Display Alternative WLS Water 2230 Level 5300T Connection Radar to DCS www Average Radar with parabolic antenna 5400T Radar Level Gauge Input 2240S Open and scalable Two-wire bus or wireless Emulation capabilities The precision instruments of tank gauging 2240S Multi Field Display To DCS Radar There are always new challenges to face in a tank storage facility. Expansion or refurbishing projects mean you have to connect new equipment to your in stallation. This is also the case when you replace damaged or outdated technology. Rosemount Tank Gauging System lets you meet your challenges so you can maintain high plant efficiency and protect the value of your tank gauging investment. 2160/65/75 Field Communication Unit Tank Hub TankMaster PC Workstation in Network TankMaster.net for web access WLS Water Level 2240S MultiInput 5400 Radar Level Field Communicator 1 5300 Guided Wave Radar 2230 Graphical Field Display 2120 Liquid Level Switch 565 Multiple Spot 765 Multiple Spot with Water Level Fn 2 4 3 5 7. 6 8 0 with Spot 9 -
When every drop counts, you can Taking safety to a higher level Lawmakers, corporate management, members of the community demands for increased safety come from just about everywhere. Rosemount Tank Gauging System allows you to meet existing and future requirements and protect plant assets, the environment and human lives. World s first high precision SIL 3 radar In addition to measuring level, a radar level gauge can be used for overfill and dry-run prevention. Together with other radar devices and switches (see examples below) and tank hubs you can achieve SIL 2/SIL 3 certified level alarm functionality. The is also available with two independent radar gauges in one housing (2-in-1) enabling SIL 3. Radar never sleeps Rosemount radar level gauges are always in operation. This is not the case with passive devices like traditional switches, where you can only be sure they are working at the very instant you run a test. With two separate gauges, you can compare the results and immediately spot if one gauge is not working. Wide range of overfill prevention options Unique 2-in-1 feature SIL 2 and SIL 3 safety Continuous surveillance count on radar technology Rosemount Tank Gauging System gives you precise data for certified custody transfer, inventory management, and loss control. The level measurement accuracy of ±0.5 mm (0.02 in.), together with the highest precision average tem perature measurement, ensures exact net volume calculations. In cases where medium accuracy is sufficient, we offer a number of cost-effective gauging instruments. Works everywhere Rosemount Tank Gauging System suits all kinds of applications and tanks: pressurized and non-pressurized, with fixed or floating roofs, with or without still-pipes. This makes it the perfect choice for refineries, tank terminals, fuel depots, LNG plants and more. The best there is With Rosemount Tank Gauging System you enjoy precise tank gauging. More accurate The pioneer in radar-based tank gauging billing, better tank utilization and higher safety are some of the benefits. No moving parts also make the gauges reliable, virtually maintenance-free and long lasting. Simply put, the money you invest is soon paid back and turned into years of profits. World market leader Proven performance Always close at hand Accuracy of ±0.5 mm (0.02 in.) Precise net volume calculations All tank storage applications + Dual radar gauges for level and overfill measurements. SIL 2 certified with the possibility to achieve SIL 3 safety level. (2-in-1) Two radar gauges in one housing independent level and overfill measurements. SIL 2 and SIL 3 safety. + 5300/5400 Radar level gauge and radar level transmitter independent level and continuous high-level alarm. Suitable for SIL 2 safety. + 2120 Radar level gauge and point level switch. Suitable for SIL 2 safety. We invented radar tank gauging, delivered our first radar level gauge in 1975 and have since then delivered over 100 000 units all over the world more than anyone else. Emerson s tank gauging representatives are located worldwide, providing you with service and support from highly trained service engineers in more than 80 countries.... for marine tankers (1975) We introduced the world s first radar level gauge with 2-in-1 and 3-in-1 (2002) for on-shore tanks with custody transfer accuracy (1984) with SIL 2 certification (2007) with wireless communications (2009) with 2-in-1 and SIL 3 safety (2010)
Rosemount Tank Radar AB. Ref.No. 00803-0100-5100, Rev AA, September 2014 The contents of this publication are presented for information purposes only, and while efforts have been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. Rosemount Tank Radar AB accepts no responsibility for any errors that may appear in this publication. Rosemount Tank Gauging Box 130 45 SE-402 51 Göteborg SWEDEN Tel: +46 31 337 00 00 Fax: +46 31 25 30 22 E-mail: sales.rtg@emerson.com www.rosemount-tg.com Rosemount Tank Gauging North America Inc. 6005 Rogerdale Road Mail Stop NC 136 77072 TX Houston United States Primary Phone: +1 281 988 4000 Secondary Phone: +1 800 722 2865 E-mail: sales.rtg.hou@emerson.com Latin America 1300 Concord Terrace, Suite 400 Sunrise Florida 33323 United States Tel: +1 954 846 5030 Rosemount Tank Gauging Middle East & Africa. P. O Box 20048 Manama Bahrain Tel: +973 1722 6610 Fax: +973 1722 7771 E-mail: rtgmea.sales@emerson.com Asia Pacific Pte Ltd 1 Pandan Crescent SINGAPORE 128461 Tel: +65 6777 8211 Fax: +65 6777 0947 Email: specialist-itg.rmt-ap@ap.emersonprocess.com The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of one of the group of companies. HART and HART are registered trademarks of the HART Communication Foundation. All other marks are property of their respective owners. 2014 Rosemount Tank Radar AB. All rights reserved.