Principles and clinical applications of ray-tracing aberrometry (Part II)

Similar documents
10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

Customized intraocular lenses


Refractive Power / Corneal Analyzer. OPD-Scan III

Medical Dpt., Medicem Prague, Czech Republic 2. Medicem Institute, Kamenne Zehrovice, Czech Republic 3

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

The Aberration Structure of the Keratoconic Eye

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

DesiGneD and ManUFaCTUreD in italy The sharpest vision.

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

THE SHARPEST VISION. DESIGNED AND MANUFACTURED IN ITALY

Optical Path Difference Scanning System OPD-Scan II ARK-10000

Surgical data reveals that Q-Factor is important for good surgical outcome

What is Wavefront Aberration? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World?

Wave-Front Analyzer KR-1W

Aberrometry in Clinical Practice

Improving Lifestyle Vision. with Small Aperture Optics

Refractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Clinical Update for Presbyopic Lens Options

KERATOCONUS. In the most advances cases, the corneal deformation can be easy observed fig. 1. Fig. 1

Aberrations Before and After Implantation of an Aspheric IOL

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER

Unique Aberration-Free IOL: A Vision that Patients

Optical Connection, Inc. and Ophthonix, Inc.

(495) (495)

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

Headline. Pseudophakic Implants, Aspherical Optics, Quality of Vision for Cataract Patients Subline. Damien Gatinel, MD, PhD

Treatment of Presbyopia during Crystalline Lens Surgery A Review

4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston

What s New in Ocular Biomechanics?

Explanation of Aberration and Wavefront

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT

The complete choice in refractive lens solutions

FOR PRECISE ASTIGMATISM CORRECTION.

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Dr. Magda Rau Eye Clinic Cham, Germany

Long-term quality of vision is what every patient expects

Optimized Profiles for Astigmatic Refractive Surgery

ROTATIONAL STABILITY MAKES THE DIFFERENCE

In this issue of the Journal, Oliver and colleagues

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

Design of a Test Bench for Intraocular Lens Optical Characterization

Although, during the last decade, peripheral optics research

ATLAS Corneal Topography System

Transferring wavefront measurements to ablation profiles. Michael Mrochen PhD Swiss Federal Institut of Technology, Zurich IROC Zurich

Keratoconus is one of the most leading causes for visual disability

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects

Fitting Manual Use with kerasofttraining.com

CATARACT SURGERY AND DEPTH OF FIELD (D.O.F.)

OCULUS Pentacam AXL Always an Axial Length Ahead

The Dysphotopsia Mystery. John J. Bussa, M.D.

Roadmap to presbyopic success

Optical aberrations and the eye Part 3

Corneal Mapping over the Contact Lens. Challenge: Getting the Most out of Soft Contact Lens Multifocals

Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions

OCULUS Keratograph 4. Topographer. We focus on progress

Aberrations and Visual Performance: Part I: How aberrations affect vision

CLINICAL SCIENCES. Corneal Optical Aberrations and Retinal Image Quality in Patients in Whom Monofocal Intraocular Lenses Were Implanted

4/11/2016 DISCLOSURES DR. EIDEN (CONSULTING, LECTURER, RESEARCH, OR FINANCIAL INTEREST*)

Author Contact Information: Erik Gross VISX Incorporated 3400 Central Expressway Santa Clara, CA, 95051

TRANSLATIONAL SCIENCE. Effect of Crystalline Lens Aberrations on Adaptive Optics Simulation of Intraocular Lenses

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK.

Evolution of Diffractive Multifocal Intraocular Lenses

Keratoconus contact lenses

Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes

Subjective refraction OPTICS OF HUMAN EYE & REFRACTIVE ERRORS

Customized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens

Binovision A new Approach for Seeing without Glasses

Corneal and total optical aberrations in a unilateral aphakic patient

case report Scleral lens fit based on OCT data

Visual Simulation: application to monofocal intraocular lens analysis

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

Aberration Interaction In Wavefront Guided Custom Ablation

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

Comparison of retinal image quality with spherical and customized aspheric intraocular lenses

Technicians & Nurses Program

Research Article In Vitro Aberrometric Assessment of a Multifocal Intraocular Lens and Two Extended Depth of Focus IOLs

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

Cataract Information. victoriaeye.com

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology

EDoF IOL. ZEISS AT LARA 829MP Next generation Extended Depth of Focus Intraocular Lens. NEW EDoF IOL from ZEISS

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

DESIGNED FOR SUCCESS...GUARANTEED TO FIT

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide

ALADDIN. Optical Biometry and Topography System

An Interesting Use of Bausch and Lomb s KeraSoft IC Lens

Introduces The OK -EX -Total Tear Layer Control- Features. What is the OK-EX? Multi-Axis Toric Option.

Agenda. 1. EyeLT Step 1 2. EyeLT Step 2 3. EyeLT Step 3

Multifocal and Accommodative

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

ALADDIN addresses the limitations of conventional biometers

Transcription:

UPDATE/REVIEW Principles and clinical applications of ray-tracing aberrometry (Part II) Alfredo Castillo Gómez, MD, PhD 1 ; Antonio Verdejo del Rey, OD 2 ; Carlos Palomino Bautista, MD 3 ; Ana Escalada Ferrándiz, MD 4 ; David Carmona González, OD 5 ; Sara Ceballos Burgos, OD 6 APPENDIX CLINICAL CASES Several real clinical cases are analysed below in order to obtain greater understanding of the itrace system for clinical exploitation. Normal Eyes The emmetropic eye (refractive map) Refractive map of the WF Summary Display Here we analyse an emmetropic eye with VA correction not surpassing 20/20. The first map solely takes LOA into account (which affect the total quality of vision) and therefore appears entirely in green. The second map appears in blue, green and yellow but all with refractive values close to 0 in accordance with the colorimetric scale in D. We can therefore deduce that this eye is more greatly affected more by HOA, which have little influence on vision. This is corroborated by Total LO and HO RMS values (right-hand side values) which result in good VA without correction values. 1 Jefe de Servicio Oftalmología. Hospital Universitario Quirón (Madrid). Profesor Universidad Europea de Madrid. 2 Clínica Real Vision. Madrid. Director del Departamento de Contactología Clínica del COI. Madrid. Profesor Externo de la Universidad Europea de Madrid. 3 Jefe de Servicio de Oftalmología. Hospital Universitario Quirón. Madrid. Profesor Universidad Europea de Madrid. 4 Médico Adjunto. Unidad de Córnea y Cirugía Refractiva. Hospital Universitario Quirón. Madrid. 5 Diplomado en Óptica y Optometría. Hospital Universitario Quirón. Madrid. 6 Diplomada en Óptica y Optometría. Clínica Real Visión. Madrid. Corresponding Author: Alfredo Castillo Gómez, MD, PhD. Quintana, 1-2.º C. 28008 Madrid. E-mail: drcastillo@telefonica.net 2010 SECOIR Sociedad Española de Cirugía Ocular Implanto-Refractiva ISSN: 2171-4703 157

158 PRINCIPLES AND CLINICAL APPLICATIONS OF RAY-TRACING ABERROMETRY (PART II) The astigmatic eye (refractive map) The Total Refractive map shows a with-the-rule astigmatism of approx. 2.12 D, which is what predominantly affects the poor vision of this patient as seen in the PSF and Total Snellen E. With this system we can go further and analyse exactly where the astigmatism shown in the total refraction comes from. To this end, we can use corneal topography, as its axial map (bottom right) corresponds to the refractive map (analysed previously). However, the value of the astigmatic corneal aberration (bottom left) is lower than the total (top right). The remaining aberrations come from the internal optics of the eye (top left). Separating corneal, internal and total aberrations we can also see that the lens compensates for part of the defocus and the spherical aberration of the cornea.

PRINCIPLES AND CLINICAL APPLICATIONS OF RAY-TRACING ABERROMETRY (PART II) 159 Eye Pathology Keratoconus (II-III, KSS) pre and post implantation of intracorneal segments. As previously explained, by combining WF and CT in one screen we can study corneal topography by selecting a map of choice, in this case the axial map. We can also study corneal aberrations based on the cornea as well as those induced by the internal optics and subsequently, total aberrations of the eye. In keratoconus, predictably, the cornea is responsible for the main aberrations. It is very useful to undertake an overall study in order to decide the exact implantation of the segments and gain the best result. For example, the internal optics generate a total spherical refraction of approx. 5.00 D in myopia, while compensating for part of the corneal astigmatism. In this case, the astigmatism and coma axes coincide, facilitating the decision-making process and allowing us to treat both sphero-cylindrical refraction and coma. It was noted that both measurements, before (left) and after (right) were taken from the entrance pupil with a similar diameter (under mesopic lighting conditions). Only one segment with an optical zone of 6 mm was implanted. On the top right-hand side image we can clearly see the location of the ring, not yet in the pupil zone. The patient therefore does not report the usual halos or glares caused by the ring. As the implantation of the segment has changed the structure of the cornea, the RSD that we now obtain (right) is much less aberrated than prior to the procedure (left).

160 PRINCIPLES AND CLINICAL APPLICATIONS OF RAY-TRACING ABERROMETRY (PART II) If we analyse the axial difference map (left), we can quantify the effect of the ring as well as its placement, which is perfectly in line with the previous image. Comparing the pre (bottom) and post (top) topographic axial maps, we see the changes in corneal morphology. The keratometry of the most curved axis has decreased; the cone has centred in relation to the pupil and therefore the spherical aberration of the cornea is more negative. At this point, after ring implantation, we checked the total aberrometric status and compared pre and post implantation RMD values. Changes induced in the cornea reduced astigmatism and defocus by half a point. In terms of refraction there was 2.00 D of reduction of myopia and 2.37 D of reduction of astigmatism.

PRINCIPLES AND CLINICAL APPLICATIONS OF RAY-TRACING ABERROMETRY (PART II) 161 Cataracts The cornea is practically spherical, creating a quite homogeneous wavefront map which is almost entirely green. It can be observed that the WF Map Total (top right) is due to the opacification of the lens as the two top maps (WF internal optics and Entire Eye Total) are very similar. Lasik For a 26-year-old patient who underwent surgery 6 months ago optimized Lasik treatment with an aspheric ablation pattern was used. If we focus on the axial map prior to (top) and post surgery (bottom) as well as the values obtained from them, we see that after Lasik the cornea is more oblate. However, the positive corneal spherical aberration induced after myopic ablation is practically non-existent, i.e. the previous positive value is maintained. This is due to the pattern of spherical ablation produced, taking into account the previous Q value and that expected after Lasik.

162 PRINCIPLES AND CLINICAL APPLICATIONS OF RAY-TRACING ABERROMETRY (PART II) A comparison between the total spherical aberration maps (Z 4.0) pre and post Lasik was made. Maintaining the positive spherical aberration of the cornea prevents an increase in total aberration as the patient is young and the lens compensates with a negative spherical aberration to keep the total close to 0 and to obtain good quality of vision. This is evidenced in the VFA of the bottom image. Multifocal lens The case of a 56-year-old post-phacolensectomy patient with implantation of a toric refractive multifocal IOL of aspheric design. The previous refraction of this patient was +5.00 ( 4.00) 175 with a +2.00 addition. In line with this, implantation of the aforementioned IOL design was decided. If we solely compare the aberrometric maps for astigmatism, we see that the WF generated by the IOL (top right) is similar to the WF of the cornea (bottom left) with a 90 rotation. This is ideal for compensating overall corneal astigmatism. However, IOL compensation in turn induces astigmatic aberration in a differ ent orientation, which is reflected in the Total WF Total (top right) and, of course, in the patient s vision. On the other hand, the IOL of aspheric design compensates corneal spherical aberration correctly as it shifts from a value of +0.279 microns to nearly zero (+0.050 microns), as reflected in the total aberration (top right).

PRINCIPLES AND CLINICAL APPLICATIONS OF RAY-TRACING ABERROMETRY (PART II) 163 Corneal transplant We describe the case of a 62-year-old patient who underwent keratoplasty after Fuchs dystrophy 2 years ago. Cataract surgery was performed 6 months ago in the same eye with implantation of a monofocal IOL of an aspheric design. In spite of the irregularity of the cornea, the itrace system allows us to take correct measurements with very reliable data; out of the 256 points projected through the entrance pupil, none were rejected. The cornea is responsible for a large number of aberrations, causing the irregularity in the morphology of the RSD. We performed a more detailed aberrometric study, combining the CT and WF and decomposing each WF into the Zernike polynomials shown in the bar graph. On the bottom left side we analyse corneal aberrations (according to the axial topographic map on the right); both low and high order aberrations appear very altered. On the other hand, we can see that the internal optic, i.e. the IOL (top left), to a large extent, compensates corneal aberrations (same size bars but with different sign, shown in another color). This greatly decreases total RMS values (top right), particularly those of high order. We can therefore assert that the IOL successfully contributes to the sight of this patient.

164 PRINCIPLES AND CLINICAL APPLICATIONS OF RAY-TRACING ABERROMETRY (PART II) Phakic lens A 29-year-old patient with refraction in her RE of 9.00 ( 6.00) 175 and VA 0.4. We analysed topography using CT, detecting corneal astigmatism of nearly 3.00 D. The other 3.00 D are therefore derived from the internal optics. Implantation of an anterior chamber phakic toric IOL to compensate overall sphero-cylindrical refraction.

PRINCIPLES AND CLINICAL APPLICATIONS OF RAY-TRACING ABERROMETRY (PART II) 165 Once this IOL was implanted, we analysed aberrometric status and the visual quality of this patient. Combining the WF with CT we noticed a corneal aberrometric map typical of astigmatism, neutralised by the IOL. It should be noted that both WF maps are symmetrical but present inverted colours, this makes the WF total map very ho mogeneous, with colours close to green and with a total RMS of 0.361 microns. For a more comprehensive study, we chose the option of decomposing each map into the different Zernike polynomials through a bar graph. The IOL compensates overall corneal astigmatism but to a certain degree also induces this, evident in total refraction ( 0.75 to 99 ). It also induces a mild comatic aberration. First author: Alfredo Castillo Gómez, MD, PhD Hospital Universitario Quirón Madrid, Spain