Installation Instructions RF identification system Read/write head ANT430 ANT431

Similar documents
Installation Instructions RF-identification system Read/write head ANT513

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

Operating instructions. RFID UHF antennas Low range / ultra-low range Mid range / short mid range Wide range

Operating instructions. RFID UHF reader DTE800 DTE810 DTE900 DTE910 DTE / / 2017

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Innovation First, Inc. RS MHz Robot Controller User Manual

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

Bluetooth Sports Headphones

Original operating instructions Fail-safe inductive sensor GG507S

ON!Track smart tag AI T380. English. Printed: Doc-Nr: PUB / / 000 / 02

Installation instructions for encoders. RM3xxx RM7xxx RN3xxx RN7xxx /02 08/2015

Operation and Maintenance Manual

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2018

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

AC 3. Active Antenna Combiner. Instruction manual

Receiver Type /Version Factory No. Frequency. Transmitter Type /Version Factory No. Frequency

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction

SOM i.mx6. Regulation Information. Simple. Robust. Computing Solutions. Rev 1.1

MPRF01 Wireless 5uA Inductive Proximity Sensor RF System

Original operating instructions Fail-safe inductive sensor GM705S

USER MANUAL Universal Gateway U9921-GUV (P/N: 40994G-01)

Instruction manual ADN-W AM. Antenna Module

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

USER MANUAL. Sens it SENS IT 2.4

Operating instructions Diffuse reflection sensor with background suppression. OJ51xx laser / / 2010

Operating instructions optical fork sensor OPU200 OPU200 / / 2018

Device manual Inclination sensor 2 axes JN /00 04/2015

Transponder Reader TWN4 MultiTech 3 Quick Start Guide

Antenna Splitter ASA 1. Instruction manual

CARE +MAINTENANCE Cleaning Important Safety Instructions Water Drop Heat Battery Charging Repair

Contents. Page English 1. French. Spanish. Reset of MIN/MAX records 915 MHz Reception Mounting Care and Maintenance Warranty Information

How to install your ecobee Switch+

USER MANUAL Digital Wireless Gateway U9120-W4 (P/N: 44002G-01)

AN0509 swarm API Country Settings

Operating instructions Contrast sensor O5K / / 2016

1. Welcome. 2. Description

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc

Panther. Installation instructions. Transmitters PN-TX-MD3M (PN-T13-3) PN-TX-MD4M (PN-T13-4) PN-TX-MD6M (PN-T13-6) PN-TX-MD8M (PN-T13-8) PN-TX-MD10M

AUTOMATE Interior Sun Sensor

TV Transmitter. User Guide Master

Installation and user s guide H A. NCi-5 non-contact tool setting interface

PA421B PA821B. Front Panels. Included Components. Features. Model Variations. Antenna Combiner

Manual Supplement. Title: 381 Users Supplement Issue: 8 Part Number: Issue Date: 7/16 Print Date: July 2010 Page Count: 8 Revision/Date:

USER MANUAL Wireless Belt Station U9913-BSW (P/N: 40992G-07)

AIS 300 Installation Instructions

Complete guide to icube II. Wireless programming

WML- 46### User Manual

Information Technology Equipment (Including Digital Apparatus) Limits and Methods of Measurement

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance Information

EA200 uhf EA200 vhf User Guide

General Safety and Precautions 1. Read all of the information in the owner s manual and other included product information in the packaging before

DRAFT ONLY FOR CLINICAL TESTING Nucleus 7 Remote Control User Guide CR310

Technical Description. Wireless Automation Input/Output Module WDIO100

Quick Start Guide. Antenna Alignment Tool AIMWLLR0-35. QSG rev 7 AIMWLLR0-35 [NRB-0200] QSG.indd 1

Technical Documentation

S5-ADU. Front... 4 Rear... 4

MDW-45 Converter RS RS-422/485

ACT-IR220L/LE IrDA Serial Port Adapter

Nano SPY Ref : 11816C

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Page 1 of Release 2.2. LON Transponder Reader. Technical Reports

Agilent G1888 Network Headspace Sampler

Appearance of device and accessories may vary.

Weather Forecast Station with Atomic Time Model: BAR206 / BAR206A

Regulatory Compliance Statement

WIRELESS 915 MHz TEMPERATURE STATION Instruction Manual

USER MANUAL Push Back Gateway U9920-GPB (P/N: 40993G-01)

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

SER8300 Series Terminal Equipment Controller with Optional PIR sensor Installation Guide

Link Mobile Gateway User Guide A ProVIEW System Component

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1-7.doc

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Ambient Weather WS-40 Wireless Indoor / Outdoor Thermometer

ACT-IR220Li/220LN IrDA Serial Port Adapter

MPR kHz Reader

Manual Unihan UPWL6580

FMT4R FM Transmitter User s manual

X80 Activator. User's Manual. Version 1.1.

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual D

Husqvarna Fleet Services Machine Sensor. Machine Sensor Please read these instructions carefully before using the device. Original instructions

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

Connected Cooler Radio. Quick Start Guide

Polycom VoxBox Bluetooth/USB Speakerphone

5.5 SLG 75. Read/Write Devices Read/Write Antennas

swarm radio Platform & Interface Description

Radio receiver FS20 EAM

Ambient Weather F007TH Wireless Thermo-Hygrometer User Manual

Thermo Bluetooth-enabled Thermometer. Model: EMR211 USER MANUAL CONTENTS

SIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4

Radio System Strobe Wizard Plus Freemask

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Ambient Weather WS-0270 Wireless Indoor / Outdoor Thermometer with Indoor Humidity User Manual

HORNET Remote Control Systems

Table of Contents. Polytel GMA Glucose Meter Accessory Model PWR USER MANUAL Version: 2

focushand 2 Users Manual FocusHAND System description

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual E

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2009

AC Active Transmitter Combiner 8:1

Transcription:

Installation Instructions RF identification system Read/write head ANT430 ANT431 UK 80262949 / 00 04 / 2017

Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 2.1 General...4 2.2 Radio equipment...5 2.3 Interference of electronic and medical devices...5 3 Functions and features...5 4 Functions...5 4.1 Operating principle...5 4.2 Overview...6 5 Installation...6 5.1 General installation instructions...6 5.2 Notes on ID tag mounting...6 5.3 Avoiding interference...7 5.4 Mechanical design...7 5.5 Fixing...7 5.6 Mounting distances...8 5.6.1 ANT430...8 5.6.2 ANT431...8 5.7 Positioning of the ID tags...9 5.7.1 ANT430...9 5.7.2 ANT431...9 6 Electrical connection...10 6.1 Wiring...10 6.2 culus...10 7 Display elements... 11 8 Operation... 11 9 Dimensions...12 9.1 ANT430...12 9.2 ANT431...12 10 Technical data...12 2

11 Maintenance, repair and disposal...13 12 Approvals/standards...13 12.1 Radio approvals...13 12.1.1 Overview...13 12.1.2 Europe...13 12.1.3 USA...13 12.1.4 Canada...14 12.1.5 Taiwan...14 12.1.6 Australia...14 12.1.7 EC declaration of conformity...14uk 3

1 Preliminary note This document is part of the device and contains information about the correct handling of the product. This document is intended for specialists. These specialists are people who are qualified by their training and their experience to see risks and to avoid possible hazards that may be caused during operation or maintenance of the device. Read this document before use to familiarise yourself with operating conditions, installation and operation. Keep this document during the entire duration of use of the device. 1.1 Symbols used Instructions Cross-reference Important note Non-compliance can result in malfunction or interference. Information Supplementary note 2 Safety instructions 2.1 General Observe the operating instructions. Non-observance of the instructions, operation which is not in accordance with use as prescribed below, wrong installation or incorrect handling can affect the safety of operators and machinery. The installation and connection must comply with the applicable national and international standards. Responsibility lies with the person installing the device. The device must only be installed, connected and put into operation by a qualified electrician as the safe function of the device and machinery is only guaranteed when installation is correctly carried out. Disconnect the unit externally before handling it. In case of malfunction of the device or uncertainties please contact the manufacturer. Tampering with the device can seriously affect the safety of operators and machinery. This is not permitted and leads to an exclusion of liability and warranty. 4

2.2 Radio equipment In general, radio equipment must not be used in the vicinity of petrol stations, fuel depots, chemical plants or blasting operations. Do not transport and store any flammable gases, liquids or explosive substances near the unit. 2.3 Interference of electronic and medical devices Operation can affect the function of electronic devices that are not correctly shielded. Disconnect the device in the vicinity of medical equipment. Contact the manufacturer of the corresponding device in case of any interference. UK 3 Functions and features In connection with the evaluation unit DTE10x the read/write head ANT430/ ANT431 enables non-contact reading and/or writing of the RFID transponders (ID tags) conforming to the system. The data is converted into digitally coded values and provided to the evaluation unit. 4 Functions 4.1 Operating principle The ID tags are operated passively, i.e. without battery. The energy required for operation is supplied by the read/write head. The physical principle of the energy transfer is based on inductive coupling. The integrated antenna coil in the read/write head generates a magnetic field which partly penetrates the antenna coil of the ID tag. A voltage is generated by induction that supplies the data carrier with energy. 5

4.2 Overview Art. no.: Function: Type designation: Operating frequency: Type: Max. transmission power: Art. no.: Function: Type designation: Operating frequency: Type: Max. transmission power: ANT430 Read/write head DTRHF IBRWIDUS03 13.56 MHz M30, flush mountable 200 mw ANT431 Read/write head DTRHF INRWIDUS03 13.56 MHz M30, non-flush mountable 200 mw 5 Installation 5.1 General installation instructions When mounting several read/write heads adhere to the minimum distances between the systems. Flush mounting of a read/write head in metal reduces the read/write distance. The immediate vicinity of powerful HF emission sources such as welding transformers or converters can affect operation of the read/write heads. Information on the available mounting accessories is available on our website at: www.ifm.com 5.2 Notes on ID tag mounting If the ID tags are mounted in/on metal, the read/write distance is reduced. 6 For positioning the ID tags the read/write heads are marked with an antenna symbol on the active face. It designates the middle of the integrated antenna coil and has to correspond with the middle of the ID tag. The orientation of the read/write head antenna axis must correspond with the axis of the ID tag coil.

The best way to position the available ID tags and on mounting in metal is available on our website: www.ifm.com 5.3 Avoiding interference The device generates a modulated electrical field with a frequency of 13.56 MHz. To avoid interference of the data communication no other devices generating interference emission in this frequency band must be operated in the vicinity. Such devices are for example frequency converters and switched-mode power supplies. 5.4 Mechanical design UK 1: Sensing face 5.5 Fixing Fix the device using the supplied nuts (M30). flush (ANT430) non-flush (ANT431) 7

5.6 Mounting distances 5.6.1 ANT430 Operating mode Distance side (A) Distance front (B) For reading and writing 50 mm 100 mm 5.6.2 ANT431 8 Operating mode Distance side (A) Distance front (B) For reading and writing 120 mm 160 mm

5.7 Positioning of the ID tags 5.7.1 ANT430 D UK Align the ID tag on the antenna central axis. Distance read/write head (D) ID tag Type metal plastics E80370 20 mm 20 mm E80371 25 mm 30 mm All indications apply to static read/write operations. 5.7.2 ANT431 D Align the ID tag on the antenna central axis. Distance read/write head (D) ID tag Type metal plastics E80370 35 mm 35 mm E80371 45 mm 45 mm All indications apply to static read/write operations. 9

6 Electrical connection ATTENTION The unit must be connected by a qualified electrician. Device of protection class III (PC III) The electric supply must only be made via PELV/SELV circuits. Disconnect power before connecting the unit. 6.1 Wiring Connect the device to the evaluation unit DTE10x using the M12 connection. Voltage is supplied via the evaluation unit. 3 1 4 1 4 3 L+ DATA L A selection of sockets is available on our website at: www.ifm.com Cables with the following characteristics are suitable for the connection: Length Ohmic resistance (feed + return line) Effective cable capacity < 20 m max. 3Ω max. 3 nf 6.2 culus For units with culus approval and the scope of validity culus: Supply the device from an isolating transformer having a secondary UL-listed fuse rated a) 5 A at voltages of 0...20 V rms (0...28.3 V p ) b) 100/V p at voltages of 20...30 V rms (28.3...42.4 V p ) 10

7 Display elements ANT430 ANT431 LED LED UK LED green: operating voltage LED yellow: ID tag LED Status Description Green ON Operating voltage OK OFF FLASHING SLOWLY Operating voltage missing Deactivated Yellow ON (permanently) ID tag detected Green + yellow ON (pulse) FLASHING QUICKLY OFF FLASHING ALTERNATELY ID tag read/written successfully Error when reading/writing on ID tag No ID tag in the field or faulty ID tag in the field or invalid ID tag in the field error in communication or device fault 8 Operation The read/write head is configured via the connected evaluation unit DTE10x. You can find more information about the operation in the manual: www.ifm.com 11

9 Dimensions 9.1 ANT430 50 39 37 29 1,5 M12 x1 M30x1,5 5 36 9.2 ANT431 50 39 37 18 15 M12 x1 M30x1,5 5 36 10 Technical data The data sheets are available on our website at: www.ifm.com 12

11 Maintenance, repair and disposal Do not open the housing as the device does not contain any components which must be maintained by the user. The device must only be repaired by the manufacturer. Dispose of the device in accordance with the national environmental regulations. 12 Approvals/standards 12.1 Radio approvals 12.1.1 Overview The overview of the approval status of a unit is available on our website at www. ifm.com. 12.1.2 Europe Use in all EU countries 12.1.3 USA FCC note: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device must not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this equipment not expressly approved by ifm may void the FCC authorization to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. UK 13

12.1.4 Canada IC note: This device complies with Industry Canada license-exempt RSS standards. Operation is subject to the following two conditions: 1. The device may not cause interference, and 2. the user of the device must accept any interference received, including interference that may cause undesired operation. 12.1.5 Taiwan Administrative Regulations on Low Power Radio Wave Devices warning Article 12 Unless granted permission by NCC, no company, firm, or user shall alter the frequency, increase the transmitting power, or alter the original design characteristics or operating functions of an approved low-power radio-frequency device. Article 14 Low-power radio-frequency devices shall not affect aircraft security nor interfere with legal communications. If such interference occurs, the user shall immediately cease operating the device until improvement is made and the interference no longer exists. Legal communications refers to the wireless telecommunication operations that comply with the Telecommunications Act. Low-power radio-frequency devices must accept any interference received from legal communications and ISM radio wave devices. 12.1.6 Australia Use in Australia: 12.1.7 EC declaration of conformity ifm electronic gmbh hereby declares that the ANT430 / ANT431 radio system corresponds to the directive 2014/53/EU. You can find the EC declaration of conformity on our website at: www.ifm.com. 14

15 UK