MBC /602(L) MBC /602(L) MBC /602(L)

Similar documents
Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Digital inductive conductivity transmitter

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Digital flow ELEMENT transmitter for continuous flow measurement

2/2-Way Solenoid Control Valve

SIT 849 SIGMA LH M U LT I F U N C T I O N A L C O N T R O L F O R G A S B U R N I N G A P P L I A N C E. w w w. s i t g r o u p.

The transducer component converts the measured signal and displays the actual value.

Digital flow transmitter for continuous flow measurement

B34 Series Regulator Commercial and Industrial Regulator

Digital flow ELEMENT transmitter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

2/2 way Proportional Valve (motordriven)

OPTIMASS 1000 Technical Datasheet

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Digital conductivity transmitter

TIDALFLUX 2300 F Technical Datasheet

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

INLINE flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

PROPORTIONAL PRESSURE CONTROLS TECNORD

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Electromagnetic Flow Transmitter

RCM DIRECT READING FLOWMETER

ph or ORP Transmitter

OEM radar transmitter, for aggressive media level measurement

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

OPTIFLUX 5000 Technical Datasheet

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

Proportional Directional Control Valves Nominal sizes 16 and 25

Magnetic Inductive Flow Sensors induq. Series VMI

2/2 way Coaxial Valve CX03M to CX05M direct acting

OPTIFLUX 5000 Technical Datasheet

Level Lance Model 5100

GB/GW GB/GW GB/GW GB/GW

Digital flowmeter for continuous flow measurement

Ultrasonic level transmitter, non-contact

Target disk flowmeter for liquids and gases

FLOWave SAW-Flowmeter

Echotel Model 910 Ultrasonic Level Switch

mass flowmeter for compressed air

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

DENISON HYDRAULICS Proportional Pressure Control Valves

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

WATERFLUX 3070 Technical Datasheet

Products catalogue (I-P Edition)

Digital flowmeter for continuous flow measurement

A.O. SMITH WATER PRODUCTS COMPANY 5621 W. 115TH STREET ALSIP, ILLINOIS Phone: Fax:

Pressure transmitter For general industrial applications Model A-10

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

FLOMID FX Electromagnetic Flowmeter

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Mass Flowmeter CoriolisMaster FCM2000

KFS. Flap-type flow meter. Design and range of application

BATCHFLUX 5500 C Technical Datasheet

Rotary gear motor series AG8...

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Magnetic Inductive Flow Sensors VMI Series

TPV 1200 BTB. Variable Displacement Closed Loop System Axial Piston Compact Tandem Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 160 / 0516 / E

Metal tube variable area flowmeters for gases, liquids and steam

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

IP26 Series Current to Pneumatic Converter

Level gauges Series LT Level indicator, switch and transmitter for liquids

7000 Series Bronze Globe Valves Two-Way Normally Open

Proportional Directional Control Valves Size 6

.37 THRU. SPACED AS SHOWN ON A Ø 4X HOLES Ø 3.40 [86.4] BOLT CIRCLE [29.0] 4.17 Ø[105.79] BLOWER [5.33] DISCHARGE .21 MOTOR COOLING DISCHARGE 2

PARTS LIST ELECTRIC BOILERS MODELS: CE24 CE36 CE42 CE48 CE324 CE336 CE342 CE348

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Mass Flowmeter CoriolisMaster FCM2000

WATERFLUX 3000 Quick Start

Coriolis Massflowmeter

ANDERSON GREENWOOD SAFETY SELECTOR VALVE

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Operating Principles

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

FAS 10 mm PICOSOL Direct acting solenoid valve

Pressure transmitter for general industrial applications Model A-10

F-3200 SERIES Inline Electromagnetic Flow Meter Wiring Instructions

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

FIELD DEVICES PRESSURE

Using the AcuDew Moisture Transmitter

Digital batch controller

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H

Flow Measurement SITRANS F M

Liquid ring vacuum pumps in compact design

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B

OPTIFLUX 1000 Technical Datasheet

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

Operating Instructions for Flow Indicator. Model: DAZ

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

Электромагнитные пропорциональные клапаны Burkert

PWM CONTROL CONNECTION (OPTION) BLU (COMMON) PWM IN (BLK) NOT USED TACHOUT (WHT) DC VOLTAGE (RED) 4X R..38 (9.7)

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Transcription:

GasMultiBloc Combined servo pressure regulator and safety shut-off valves MBC-... 1000/60(L) MBC-... 500/60(L) MBC-... 4000/60(L) Two normally closed automatic shutoff valves and servo regulator in one housing. Each valve has the following approvals. UL Listed / Recognized UL 49 File #MH1677 CSA Certified ANSI Z1.1 / CSA 6.5 C/I marking ANSI Z1.18 / CSA 6.3 File # 1641073 FM Approved FM 7400 File No. 3046043 Commonwealth of Massachusetts Approved Product Approval code G3-1008-119 MBC... Sales Brochure P/N 5697 Ed. 10/17 1 8 CSA Certified / FM Approved Models /60 MBC 500/60 MBC 4000/60 UL Listed / FM Approved Models /60L MBC 500/60L UL Recognized / CSA / FM Models MBC 4000/60L Codes and Standards This product is intended for installations covered by but not limited to ANSI Z83.4, ANSI Z83.18, ANSI Z1.13, UL 795, CSD-1 or CSA B149.1, CSA B149.3 and NFPA 37. DUNGS is an ISO 9001 manufacturing facility. Technical Description The DUNGS multifunctional control MBC... integrates filter, two safety shut-off valves and servo pressure regulator with the following functions: MBC-SE as positive pressure regulator MBC-SE S0 as zero governor MBC-VEF as gas / air proportionator each version also features: - Dirt trap: Microfilter - fast opening / fast closing safety shut-off valves up to 5 PSI - Servo pressure regulator with vent limiting device - Outlet pressure ranges: SE Version: -0.8 to +10 in. W.C. VEF Versions: +6 to +40 in. W.C. - Precision regulation of outlet pressure - Flanged joints with pipe threads to ISO 7/1 or NPT - Easy to install - Low weight The modular system design allows integration of valve proving systems, high and low gas pressure switches and other system accessories. The compact design allows for high flow rates at low pressure drop. Application The DUNGS MBC is recommended for commercial heating applications that require two safety shutoff valves. For SE Versions, the servo pressure regulator permits optimal mixing in forced air burners and premix burners in conjunction with mechanical or electronic integrated gas-air regulation units; this applies to modulating and multi-stage floating operating mode. For VEF Versions, the servo pressure regulator permits optimal mixing for gas / air ratio regulation.

Functional Description Gas flow 1. When valves V1 and V are closed, chamber a is subjected to inlet pressure.. The low gas pressure switch (optional) is connected to chamber a. If the inlet pressure drops below the setpoint on the pressure switch, the switch opens the limit circuit. 3. Once enabled by the control system, valves V1 and V open. Gas flow is released through chambers "a" and "b". Closing function Upon interruption of power supply, valves V1 and V, are closed by the closing springs within <1s. Schematic diagram MBC...SE M D S E R Working diaphragm Restrictor Servo diaphragm (Atmospheric) Setting spring for outlet pressure Regulator disc a p 1 R M S b E a, b Pressure chambers in flow direction p 1 Inlet pressure Outlet pressure Ambient pressure p amb D intern Standard p amb extern Option Zero Governor Versions If atmospheric diaphragm ruptures, the zero governor regulating disc closes. 11 16 15 14 13 10 9 8 7 6 5 V1 V 1 p 1 p 4 3 1 17 18 1 Pressure regulator unit Regulator spring 3 Connecting flange 4 Coarse and microfilters 5 Valve V1 6 Closing spring V1 7 Housing 8 Plunger V1 9 Solenoid V1 10 PCB 11 Electrical connection 1 Valve V 13 Closing spring V 14 Plunger V 15 Solenoid V 16 Solenoid housing 17 Adjustment: - Gas pressure 18 Breathing Port Pressure taps, gas train diagram MBC...SE 3 4 1 5 3 4 1,, 3, 4, 5 Screw plug G 1/8 8

Functional Description Gas flow 1. If the V1 and V valves are closed, chamber a is under inlet pressure.. The min. pressure switch (option) is connected to chamber a via a borehole. If the inlet pressure exceeds the reference value set in the pressure switch, the switch switches through to the automatic burner control. 3. The V1 and V valves open after they are enabled by the combustion flame safeguard. Gas flow through the chambers a and b is enabled. Closing function If the supply voltage of the coils of V1 and V valves is interrupted, the pressure springs close the valves in <1s. Block diagram MBC...VEF M D S1 S R Working diaphragm Restrictor Servo diaphragm (atmospheric) p BR Servo diaphragm for blower pressure p L Regulator disc a p 1 R M S 1 V S b a, b Pressure chambers in flow direction p 1 Inlet pressure Burner pressure, outlet pressure: P amb Ambient pressure Blower pressure p L N D internal standard p F p amb p L external option 11 16 15 14 13 10 9 8 7 6 V1 5 4 V 1 p 1 18 3 17 1 p F p L 1 Pressure regulator unit Regulator spring 3 Connecting flange 4 Coarse filter and microfilters 5 Valve V1 6 Closing spring V1 7 Housing 8 Plunger V1 9 Solenoid V1 10 Printed circuit board 11 Electrical connection 1 Valve V 13 Closing spring V 14 Plunger V 15 Solenoid V 16 Solenoid housing Setting: 17 Gas-air ratio 18 Zero point correction Pressure taps, gas train diagram MBC...VEF 3 4 1 5 3 8 1,, 3, 4, 5 Screw plug G 1/8 6, 7 Seal plug G 1/8 3 4 6 7

Specifications Nominal widths Flanges with pipe threads to ISO 7/1 (DIN 999) Safety Shutoff Valves & Regulator Maximum Operating Pressure MBC 500 MBC 4000 NPT 1/, 3/4, 1, 1 1/4, 1 1/ NPT 1, 1 1/4, 1 1/, NPT 1, 1 1/4, 1 1/, and their combinations and their combinations and their combinations 5 PSI (138 in. W.C.) For SE Versions, recommended inlet pressure for optimal performance of the regulator* For SE Versions, outlet pressure ranges For VEF Versions, Inlet gas pressure range Air loading line range Burner pressure range Ambient temperature Inlet filter Gas Pressure switch (optional) SE Versions Servo pressure regulator VEF Versions Servo pressure regulator Ratio setting range V Zero point correction N Burner pressure monitoring Pulse and connection lines S/S8: p in = 6-138 in. W.C. S30: p in = 14-138 in. W.C. S0 & N: p in = 4-41 in. W.C. S: : 1.6-8 in. W.C. S8: : - 3 in. W.C. S30: : 1-1 in. W.C. S0 & N: : 0 ± 0.8 in. W.C. p in : 6 to 138 in. W.C. p L : 0.16 to 41 in. W.C. : 0.7 to 41 in. W.C. -40 F to +140 F (-40 C up to +60 C) for CSA Versions +5 F to +140 F (-15 C up to +60 C) for UL Versions (in LPG applications, do not operate MBC below 0 C. Only suitable for gaseous LPG, liquid hydrocarbons destroy the seal materials) 50 micron filter of two layer nonwoven fabric. Filter replaceable without removing MBC from appliction. Types GAO-A, GML-A, GMH-A For further information refer to Gas Pressure Switch Sales Brochure. (# 6 359) Servo pressure regulator with adjustable outlet pressure. Versions for constant positive pressure and zero pressure available. Gas/Air ratio control with adjustable ratio V as well as correction of zero point N and combustion chamber pressure connection Ratio V = / p L = 0.4:1 3:1, other ratios on request Adjustable Downstram of V G 1/8 connection as per DIN ISO 8 for burner pressure (pbr; GAS), blower pressure (pl; AIR), firing chamber pressure (pf; combustion, atmosphere) Impulse and connection lines must be made of steel. Vent limiting device Factory installed, vent limiter per ANSI Z1.18 / CSA 6.3 Safety shut-off valve V1, V Test ports / Pressure switch mounting ports Voltage/frequency Electrical connection Rating/power consumption Switch-on duration Switching cycles Enclosure rating Radio interference suppression Two valves in series (fast-closing, fast-opening) G 1/8 DIN ISO 8, at inlet and outlet flanges, on both sides downstream of filter, between V1 and V, downstream of V. (fitting pressure switch may partially exclude measuring gas connection) 110-10 VAC 50-60 Hz, 4 VAC 50-60 Hz, 4 VDC, 1 VDC. See Approval table and Power Consumption table on page 5. DIN-connector with 1/" NPT conduit connection for UL Versions. Order separately for CSA Versions. See power consumption table 100 % Duty Cycle 60 per hour (30 s on/off) NEMA Type 1 Interference level N Materials of gas-conveying parts Housing die-cast aluminium Diaphragms, seals on NBR base Solenoid drive steel, aluminium Installation position *Regulator complies with ANSI Z1.18/CSA 6.3 for up to 5 PSI. Inlet pressures higher than recommended inlet pressures are possible provided the appliance complies with the applicable performance requirements. MBC S0 Vertical with upright solenoid only MBC-VEF & MBC S, 8, 30 Vertical with upright solenoid or horizontal with horizontal solenoid. 4 8

MBC Accessories Flange for Thread type Order No. MBC 500 / MBC 4000 MBC 500 / MBC 4000 MBC 500 / MBC 4000 MBC 500 / MBC 4000 Shutter Flanges NPT 1/ NPT 3/4 NPT 1 NPT 1 1/4 NPT 1 1/ NPT 1 NPT 1 1/4 NPT 1 1/ NPT 371 368 1999 31718 4401 369 370 003 1997 Part description MBC 500 / MBC 4000 1 " NPT (flange only) 5305 56789 1" NPT Flange set (with o-ring and 4 screws) 5513 56791 1.5" NPT (flange only) NA 5306 1.5" NPT Flange set (with o-ring and 4 screws) NA 55133 MBC Accessories Order No. Port 3 Pressure switch mounting adapter 73777 1/" Conduit adapter for P/N 10-319 40671 Burkert DIN Connector supplied with UL listed and UL recognized versions. DUNGS DIN Connector for CSA / FM. Order separately. 53731 10319 G 1/8" Test nipple with gasket 19008 Gasket for G 1/8" test nipple 17160 1/ " NPT pilot/vent adapter 5043 1/4" NPT adapter 5047 replacement filter 41916 MBC 500 replacement filter 407 MBC 4000 replacement filter 4564 Flanges and system accessories must be ordered separately. Power Consumption Table Valve Body Size Rated voltage Inrush P max. [VA] for t = 3 s Inrush current peak (A) Holding P max. [VA] Operation Recommended power of supply transformer (VA) 140 0.1 16 DC battery MBC 500 1 VDC 160 0.1 0 DC battery MBC 4000 130 13.4 16 DC battery MBC 500 4 VDC 160 13.4 0 DC battery MBC 4000 160 14 30 DC battery 10 14.7 0 50 MBC 500 4 VAC 160 13.9 0 300 MBC 4000 10 3.1 16 50 MBC 500 10 VAC 180 3.0 0 300 MBC 4000 160.4 5 300 5 8 Approval Table Type FM Approved CSA Certified UL Listed UL Recognized /60 MBC 500/60 MBC 4000/60 /60L MBC 500/60L MBC 4000/60L 4 VDC, 4 VAC, 10 VAC 4 VDC, 4 VAC, 10 VAC 4 VDC, 4 VAC, 10 VAC 4 VDC, 4 VAC, 10 VAC

Mounting dimensions [mm] MBC-1000/500 MBC-4000 e = space requirement for solenoid replacement Type DN Rp Opening time 1/ - 1 1/ < 1 s 4.0 95 MBC 500 1 - < 1 s 5.0 16 MBC 4000 1 - < 1 s 18 04 Dimensions [inch] Dimensions [mm] a b c d e f g 5.6 143 6.9 176 10 61.4 61 3.1 80 3.1 80 6.8 173 7.3 186 13 38 10.6 69 11.1 81 0.9 530 3.4 87 4.5 114 6.3 161 9. 34 10.4 65 16.7 44 Solenoid No. Weight [lbs] [kg] 03/P 8.4 3,8 04/P 14. 6,5 05/P 37.0 16.8 6 8

Pressure drop v.s. flow Volume flow pressure difference characteristics in steady state with microfilter Pressure drop (in. W.C.) Recommended operating range -... (1/ NPT) -... (3/4 NPT) -... (1 & 1-1/ NPT) Based on 60 F 14.65 psia, dry 60 80 100 00 400 700 1,000,000 4,000 7,000 10,000 Flow (CFH) of natural gas; s.g. 0.65 at 60 F Pressure drop v.s. flow Volume flow pressure difference characteristics in steady state with microfilter MBC 500 Pressure drop (in. W.C.) Recommended operating range MBC 500-... (1 NPT) MBC 500-... (1 1/4 NPT) MBC 500-... (1-1/ & NPT) Based on 60 F 14.65 psia, dry 00 300 600 1,000,000 4,000 6,000 10,000 0,000 Flow (CFH) of natural gas; s.g. 0.65 at 60 F 7 8

GasMultiBloc Combined servo pressure regulator and safety shut-off valves MBC-... 1000/60(L) MBC-... 500/60(L) MBC-... 4000/60(L) Pressure drop v.s. flow Volume flow pressure difference characteristics in steady state with microfilter MBC 4000 Pressure drop (in. W.C.) Recommended operating range MBC 4000-... ( NPT) Based on 60 F 14.65 psia, dry 00 300 600 1,000,000 4,000 6,000 10,000 0,000 Flow (CFH) of natural gas; s.g. 0.65 at 60 F f = V gas used = V Natural gas x f Density of Natural gas Density of gas used Type of gas Density [kg/m 3 ] s.g. Natural gas 0.81 0.65 1.00 Butane.39 1.95 0.58 Propane 1.86 1.50 0.66 Air 1.4 1.00 0.80 f We reserve the right to make any changes in the interest of technical progress. Karl Dungs, Inc. 3890 Pheasant Ridge Drive NE Suite 150 Blaine, MN 55449, U.S.A. Phone 763 58-1700 Fax 763 58-1799 e-mail info@karldungsusa.com Internet http://www.dungs.com/usa/ Karl Dungs GmbH & Co. KG P.O. Box 1 9 D-7360 Schorndorf, Germany Phone +49 (0)7181-804-0 Fax +49 (0)7181-804-166 e-mail info@dungs.com Internet http://www.dungs.com 8 8