Installation Instructions For Reveal

Similar documents
Installation Instructions For Reveal Light Channel

Installation Instructions for TruLine 1.6A 24VDC. Section One: Basic Configuration Options

Installation Instructions for DIY or Completed 45 Degree Light Channel

Installation Instructions for DIY or Completed Light Channel.6 Millwork

Installation Instructions For TruLine 1.6A 24VDC

Installation Instructions for Zip Suspension Downlight with Remote Power and 4" Square or Round Canopy

Installing Fixture Using Remote Power Supply

Installation Instructions for TruLine 1A Center Feed Power Channel Connector

3% VOLTAGE DROP. Installation Instructions for 400 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS!

SLOT INSTALLATION GUIDE Indoor IP20

Connecting the Channel A

INSTALLATION INSTRUCTION Indirect Recessed Channel

C 0.05" ALLEN WRENCH. Installation Instructions for Cirrus Channel Suspension T1 with 4" Square or Round Canopy. Section One: Adjusting Cable Position

Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3" Fig.1 Complete Fixture ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP PAN LOCK

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

Installation Instructions for Cirrus Suspension Downlight with Power - End Feed. Section One: 4" Flush Canopy Version

All Terrain Flares 2014 Chevy Silverado

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB. Fig.

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture

AURORA HALOGEN ACCENT HOUSING 3 ROUND AND SQUARE TRIMLESS AH3-ARE3-RBG & AH3-ASE3-RGB INSTALLATION INSTRUCTIONS

Installation Instructions

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

Lightplane 3.5 Recessed

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Assembly Instructions

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

Drywall with Plaster and Paint. Lamp: The average LED Life is 50,000 hours. per Foot. per Watt. (2x2.5WDC) (2x5WDC) (2x6WDC)

TOOLS REQUIRED: HARDWARE INCLUDED: 13MM FLAT WRENCH FOR LEVELING THE STRUCTURE RATCHET WITH 5MM HEX BIT FOR CORNER SCREWS ON TOP TRAVERSE BEAMS

Lamp: The average LED Life is 50,000 hours. per Foot 2WDC (2.5WDC) per Watt. per Foot 5WDC Lumen values are based on the 3000K LED test.

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture

INSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

Drywall with Plaster and Paint. 6" - 400" (15.2cm cm) Lamp: The average LED Life is 50,000 hours. per Foot. per Watt. per Foot (2.

Bushwacker Jeep Flat Style Fender Flares Front Pair

Jeep Wrangler JK & 4-Door Front Pair Part # Revision H

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

Mount to the Wall INSTALLATION MANUAL

TIP FOR GETTING STARTED

Ford Ranger / Bronco II Set Part # Rev B 5-04

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Assembly Instructions 10 X 10 Aluminum Frame Building

Installation Manual MODEL AE-46

Plastic Push. 5/16 Hex Head Bolt, 20 pcs. Retainer, 20 pcs. Female Bullet Connector, 4 pcs. Side Refl ex Refl ector, 2 pcs

Instruction page index: Installation Instructions for Bosca Models BOS-XX-C-XX, & BOS-XX-S-XX. Page 1 of 5

Cellular SlumberShade

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME SPIRIT/LASER LEVEL TO LEVEL THE UNIT

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH3-ARE3-RGB & AH3-ASE3-RGB. Fig.

Metroboard Pulley Replacement Procedure

13MM FLAT WRENCH FOR LEVELING THE GLIDES OF STRUCTURE 6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME

1. TOOLS + MATERIALS REQUIRED

Hawko LED Flex & Accessories Installation Instructions

TREX PERGOLA INSTALLATION INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS

Ripple Hanger ASSEMBLY INSTRUCTIONS

FLEXDC INSTALLATION GUIDE

Installation Manual MODEL E-42

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions

Box Track INSTALLATION INSTRUCTIONS

ASSEMBLY INSTRUCTIONS. enook Pro

PRO CYCTM PRO CYC, INC. SYSTEM 1.5 FS

Aeon ALR Series. EDGE FREE Ambient Light Rejecting Fixed Frame Screen USER S GUIDE

5/16 Hex Head Bolt, 16 pcs. Plastic Push Retainer, 6 pcs. Alcohol Wipe, 2 pcs. Side Refl ex Reflector, 2 pcs

FENDER FLARE INSTALLATION

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

Motorized or Crank Operated Fortress Zipper Track Shade with Housing and Side Track Installation Instructions

P/N LED LIGHT FI85 RETROFIT KIT INSTRUCTIONS

Round or Square Chicago Plenum Down Light Housing with Lamp

MobileTrak5 Installation Instructions

Locker Installation Guide. Lockers Available From CES Company Phone: Fax:

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

PHTM200 - Phantom 200 Flat Screen Wall Mount with Wafer Thin Projection Fits Screens up to 50 lbs with 200mm Mounting Patterns

NX7 SERIES 5-1/2 HANDRAIL

2. Sanding the Modules Sand the entire surface of each cyc module with 60-grit sandpaper. This will provide for better paint adhesion.

Installing your new Bevella Top. L Shaped Countertop with Joints No Finished Ends (Fits Between Four Walls)

QUANTUM 2 CIRCLE 24 Installation Instructions

Wall Panel Installation Instructions

FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L

2.0 INSTALLATION PROCEDURE. 2.1 Open the Speaker Post. 2.2 Install the Speaker and Microphone Grills. Figure 2. SPP2 rear view

CABINETRY Assembly Instructions

MESO X1 TBAR SEMI-RECESSED

Dura-Lock Roof System

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

TruLine TruQuad.5A 24VDC - PLASTER-IN LED SYSTEM

QUANTUM 2 TRAPEZOID 2509 Installation Instructions

More Storage Space Under Yacht Bed

*Patent Pending. *Trademarked. Series II. Glass Conversion Kit. (888) One-Products (888)

SURFACE CLIP MOUNT. 1 Insert lens into channel, measure, and cut to length. Remove lens cover from channel. surface. Attach lens cover and end caps

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

IMPORTANT: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE

Transcription:

2017 Pure Lighting. All Rights Reserved. Installation Instructions For Reveal IS# 902-RV-24VDC-07 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1196 Fax: 773-883-6128 www.purelighting.com info@purelighting.com IMPORTAT IFORMATIO - Reveal channel can be used as a toe kick or for cove lighting. - This instruction shows a typical installation. - It is recommended more than one person to install the Reveal Channel. SAVE THESE ISTRUCTIOS! Install the Junction Box (C-1RE-JBOX) A HORIZOTAL ORIETATIO B #8 SCREW ADJUSTABLE MOUTIG BAR PHILLIPS SCREW MOUTIG BRACKET 3 4 BOX BOX 1 2 VERTICAL ORIETATIO ADJUSTABLE MOUTIG BAR OTE: The adjustable mounting bars mount to studs that are spaced 13" to 24" apart. 2: Select the location between the two studs for the junction box to be mounted. 1: Mount each adjustable mounting bar to one side of the junction box (mounts to any side of the housing depending on the orientation of the channel) and secure them with the mounting brackets and two Phillips screws provided. 3: Place the adjustable mounting bars between the studs. 4: Make sure the lips on the adjustable mounting bars are against the studs. Secure the adjustable bars to the studs with the eight #8 screws. C CUTOUT TEMPLATE BOX D CODUIT BOX 5 7 6 FROM REMOTE PHILLIPS SCREW 5: Remove the two #4-40 screws to pull the drywall cutout template completely off the junction box face. Save the template and screws for later use. 1 6: Remove a knockout on the junction box to install conduit into the power feed electrical box. 7: Install the conduit and run the low voltage 24VDC power wires.

E 3.00" 1.06" 8 F BOX 2.80" 2.25" 9 11 0.38" 10 CUTOUT TEMPLATE JAB SAW 11:Install the drywall. 8: Mark a location on the drywall where the junction box will be located. 9: Trace the drywall cutout template onto the drywall at the junction box location. 10: Remove drywall cutout template and cut out the marked area using a jab saw or other appropriate tool to expose the junction box. G MARKIG 14 12 LEGTH OF 12 CLOSE UP BOX SLOT START 13 2.25" CUTOUT OPEIG JAB SAW 12: Using the drywall opening as reference, mark 2.25" wide lines, the complete length of the channel along the drywall. 13: Cut out the mark lines on the drywall using a jab saw or other appropriate tool. 14: Mark the location to the studs for future reference. 2

H I ED CAP CODUIT 17 BOX 15 16 SCREWS 18 OTE: Remote power supply wires must be present in the junction box. Refer to instructions provided with the power supply. 15: Connect the red power supply (24VDC+) wires to each red power wire with a wire nut inside the electrical box. 18: Install the power feed end cap to the end of the channel that will be aligned with the junction box with the supplied screws. 16: Connect the black power supply (24VDC-) wires to each black power wire with a wire nut inside the electrical box. 17: Place the wire nut connections inside junction box. J JOIIG ROD K TAKE UP BOX LED SECTIO DEAD ED CAP #6-32 SCREWS 19 20 21 OTE: Channel may be cut in the field. For installation over 120" join two or more Reveal channels together. 19: Insert joining rods halfway into the channel. 20: Slide another channel onto the joining rods. 21: Install the dead end cap and take up box to the end of the channel opposite of the junction box using the supplied screws. Ensure the slot of the dead end cap aligns with the LED section of the channel. 3

L POWER COECTOR M DRY WALL SCREW #4-40 SCREW 22 25 23 24 OTE: Test the LED strip before securing the channel to the drywall. 22: Align the "" marking on the LED strip with the red wire of the power connector. Push the male connector of the LED strip into the female connector of the power cables. Inspect the strip for any irregularities. ED CAP 23: Align the power feed end cap into the junction box opening slot and push the channel into the drywall cutout. 24: Make sure the channel is aligned straight using a level. 25: Secure the channel using the two #4-40 screws to the junction box (same screws as in step 5 page 1). Fasten the drywall screws through the pre-drilled holes onto the studs. If necessary drill new holes on channel flange where they line up with the studs using the #6 X 1-5/8" square trim screw with the square recess bit provided. OTE: Ensure screw heads sit flush with the channel. DRY WALL SCREW 26 O 27 30 27 29 POWER COECTOR PAPER BACKIG 26: Drill and countersink holes to the channel at marked stud positions. ED CAP 27: Secure the channel to the studs using drywall screws. OTE: If installation requires RGB, RGB+W, or Tunable White, refer to wiring diagrams on pages 7 through 9. 28: Connect the LED strip to the power connector and place the power connector into the slot in the power feed end cap. 29: Carefully remove the backing from the LED strip, making sure not to remove the tape from the back of the strip. 4 30: Firmly press down the adhesive portion of the LED strip onto the channel surface while removing the rest of the backing, making sure there are no air bubbles that can cause surface irregularities.

P TAKE UP BOX Q 31 31 BOX COVER #4-40 SCREW 32 32: Install the junction box cover onto the junction box using the #4-40 screws using a 1/16" Allen wrench. 31: Trim excess LED strip OLY at the indicated trim lines (see inset). Insert excess LED strip into the take-up box. R ULTRA THI TAPE 33 BLUE COTRACTORS TAPE 34 SIDE VIEW 33: Apply ultra thin drywall tape to the Reveal channel. Do not overlap sections of the drywall tape. 34: Cover up the opening section of the Reveal channel with contractors tape to prevent plaster and dust entering inside the channel. 35: Plaster the channel flange edge to the wall & fill screw holes (highlighted in green). Sand, paint, and finish the wall properly. 36: Remove the blue contractor tape & clean the inside of the channel. 5

IMPORTAT IFORMATIO REGARDIG ISTALLATIO AD REWORK OF SOFT STRIP LED DO gently pull up and away from the soft strip if removing to reposition. This avoids damaging the strip. DO OT pull the strip back towards itself. Doing so risks damaging the strip and making it not function. DO only ever use fingers to gently install soft strip to a surface AFTER cleaning the surface with alcohol. DO OT use any tool to install soft strip to a surface. This will damage the soft strip component. Relocating Soft Strip (Optional) S ADHESIVE TAPE REMOVE SOFT STRIP TO RELOCATE SOFT STRIP ADHESIVE TAPE OTE: If relocating the installed soft strip, make sure that the adhesive tape on back of the soft strip covers the entire strip. The adhesive tape isolates the strip from the installation surface. Damaged or inconsistent adhesive tape may cause the contacts on the back of the strip to come in contact with the conductive heat sink which will cause the strip to short and burn. Call Edge Lighting to get replacement adhesive tape and/or optional aluminum heat sink tape (SS-HR-F). 1: To remove tape residue from back of the strip, apply WD-40, Goo Gone, or a mixture of warm water and lemon oil to the corner of a clean, dry towel. Gently buff the area containing the adhesive residue until it is completely removed. APPLY ADHESIVE REMOVER AD THE BUFF OFF ADHESIVE 2 ADHESIVE BACKIG 1 2: Gently remove a few inches of the from one side of the tape backing. Attach the adhesive tape to the back of the soft strip and apply moderate pressure to affix the tape. Continue this step a few inches at the time until the entire adhesive tape is attached to back of the soft strip. 3: Refer to steps 28 through 31 on pages 4 and 5 to reinstall the LED strip. BACK SIDE OF SOFT STRIP 6

General 0-10V Configuration GRAY 0-10V 0-10V DIMMER PURPLE 0-10V RED 120VAC (HOT) BLACK (HOT) WHITE (EUTRAL) RED () 24V LED SOFT STRIP BLACK (-24VDC) IPUT 120VAC General 24VDC Configuration IPUT 120VAC 120VAC (HOT) EU WHITE (EUTRAL) 24V LED SOFT STRIP BLACK (HOT) ELV DIMMER RGB Configuration CDP COTROLLER Using LED Power Supply with RGB Soft Strip & CDP or CTP Control EXT in- EXT in+ DMX in shield out+ VDC- out- VDC+ out shield 24VDC + - L LIE COTROLLER L VDC+ VDC- LED supply + Ext in- Group 1 - Ext in+ Group 2 - DMX CABLE DMX in shield LedSync thru+ LedSync thru- LedSync shield M Group 3 - Group 4 - RGB LED SOFT STRIP DVR-RGB 7

RGB+W Configuration CDP COTROLLER Using LED Power Supply with RGB+W Soft Strip & CDP or CTP Control EXT in- EXT in+ DMX in shield out+ VDC- out- VDC+ out shield 24VDC + - L LIE COTROLLER L VDC+ VDC- LED supply + Ext in- Group 1 - Ext in+ Group 2 - DMX CABLE DMX in shield LedSync thru+ LedSync thru- LedSync shield M DVR-RGB Group 3 - Group 4 - RGB+W LED SOFT STRIP Tunable White Configuration Dual Power Supplies Controlled Via Individual ELV Dimmers ELV DIMMER WHITE (EUTRAL) IPUT 120VAC BLACK (HOT) 120VAC (HOT) EU HOT Power Supply RED -24VDC BLACK WHITE (EUTRAL) IPUT 120VAC BLACK (HOT) 120VAC (HOT) EU HOT Power Supply RED -24VDC BLACK ELV DIMMER 8

Tunable White Configuration RGB Power Supply with DMX Controller CDP/CTP or other DMX Signal From Any Compatible Controller L If using a CDP Color Dial, configure your CDP to Warm White mode using DIP switches and follow CDP operating instructions: O LED SYC OUT + LED SYC OUT - LED SYUC OUT SHIELD Power Supply + RED - BLACK 1 2 3 4 5 6 7 VDC+ VDC- DMX Cable (belden #9841 or CATS) Ext in- Ext in+ DMX in shield LedSync thru+ LedSync thru- LedSync shield M Driver LED supply + Group 1 - Group 2 - Group 3 - Group 4 - + + -- 9