TOMOTHERAPY H SERIES TomoH, TomoHD and TomoHDA Systems Technical Specifications

Similar documents
TOMOHD. Product Specifications

Emerging Technology: Real-Time Monitoring of Treatment Delivery EPID Exit Dose QA

3D Diode Array Commissioning: Building Confidence in 3D QA Technology

Evaluation of a diode array for QA measurements on a helical tomotherapy unit

COMPREHENSIVE TG-142 IMAGING AND MACHINE QA

ISPFILMQATM STATE-OF-THE-ART RADIOTHERAPY VERIFICATION SOFTWARE. Supports all major radiotherapy technologies! FilmQA TM

The Current State of EPID-Based Linear Accelerator Quality Assurance. Disclosures. Purpose of this First Talk 8/3/2017

A diagnostic tool for basic daily quality assurance of a tomotherapy Hi Art machine

PHYSICS QUESTIONNAIRE FORM

CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

Isocenter and Field of View Accuracy Measurement Software for Linear Accelerator

ArcCHECKTM. The Ultimate 4D QA Solution. Your Most Valuable QA and Dosimetry Tools. VMAT RapidArc TomoTherapy Pinnacle 3 SmartArc Conventional IMRT

ArcCHECK. The Ultimate 4D QA Solution. Your Most Valuable QA and Dosimetry Tools

Installation und Kommissionierung des Viewray MRIdian Linac Hamburg, 28. Mai 2018 Sebastian Klüter

QUALITY CONTROL PHANTOMS FOR RADIOTHERAPY AND MEDICAL IMAGING

IQM Detector Characteristics: Signal reproducibility

Stability of the Helical TomoTherapy Hi Art II detector for treatment beam irradiations

A positioning QA procedure for 2D/2D (kv/mv) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup

specifications TrueBeam STx System

Data. microcat +SPECT

Performance evaluation of the RITG148 + set of TomoTherapy quality assurance tools using RTQA 2 radiochromic film

specifications TrueBeam System

Impact of energy variation on Cone Ratio, PDD10, TMR20 10 and IMRT doses for flattening filter free (FFF) beam of TomoTherapy Hi-Art TM machines

8/3/2017. Use of EPIDs for Non-Routine Linac QA. Disclosure. Learning Objectives. Parts of this project received support from Varian Medical System.

CyberKnife Iris Beam QA using Fluence Divergence

Volumetric Modulated Arc Therapy. David Shepard Swedish Cancer Institute Seattle, WA

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

GE Healthcare. Senographe 2000D Full-field digital mammography system

Phantoms in Medical Physics (RT) U. Oelfke. Division of Radiotherapy & Imaging

Dornier Genesis. Urology Imaging System with FPD

IMRT Delivery System QA. IMRT Dose Delivery. Acceptance testing. Why: specific tests for IMRT? Accuracy of leaf positioning (gaps) MLC Alignment

Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy

Mobius3D. Software based IMRT QA

specifications The Complete Radiation Oncology Solution

DELWORKS DR MEDICAL. take the next step

Maximizing clinical outcomes

A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer *

DOSELAB TOMOTHERAPY TG-148 QA QUICK GUIDE TG-148 RECOMMENDED TESTS 1. V.B.1.C. - Y-JAW DIVERGENCE/BEAM CENTERING

Monte Carlo study on a new concept of a scanning photon beam system for IMRT

NeuViz 16 Computed Tomography. Elevating routine imaging for exceptional results

SRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools

A Generalized Strategy for 3D Dose Verification of IMRT/VMAT Using EPID-measured Transit Images

ArcCHECK, ein neuartiger QS-Ansatz bei der Rotationsbestrahlung

The Ultimate 4D QA Solution A 4D isotropic cylindrical detector array for arc delivery QA and Dosimetry.

Nathan Childress, Ph.D., DABR

7/23/2014. Acknowledgements. Implementing a new digital medical accelerator. New Generation of Medical Accelerators

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

Maximum Performance, Minimum Space

Get more from your images with Symphony Image Processing

MR3T LASER SYSTEMS IN RT ESSENTIAL FOR PRECISE PATIENT ALIGNMENT

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

Get more from your images with Symphony Image Processing

Evaluation of dosimetry parameters of photons and electron beams using a linear ionization chamber array

MOVING LASER SYSTEMS IN RT

LINEAR ACCELERATOR. Buyer's Guide. Version 1.1

UNIQUE. The Complete Radiation Oncology Solution SPECIFICATIONS

Discover the difference in efficiency

C a t p h a n. T h e P h a n t o m L a b o r a t o r y. Ordering Information

New spectral benefi ts, proven low dose

SRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools

SUBCHAPTER 14. THERAPEUTIC INSTALLATIONS

Sensitivity study of an automated system for daily patient QA using EPID exit dose images

Philips XPER FD10C R7.0.4

SCINTILLATING FIBER DOSIMETER ARRAY

- Water resistant. - Large size.

ISO Cube Daily QA Package

Distributed source x-ray tube technology for tomosynthesis imaging

INNOVATION BY DESIGN. Toshiba A History of Leadership REMOTE CONTROL R/F SYSTEM

2010 Philips BrightView XCT SPECT/CT

Digital Radiography X-Ray System. X Twin with X Mobil Roesys GmbH [rshsmi] 1/11

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

FMT18 FLOOR MOUNTED SYSTEM

T h e P h a n t o m L a b o r a t o r y

Table 1: Available X-ray Beam Energy Combinations (MV) 6 10/ Yes Yes 6 16/15 6 Yes No 6 23/18 6 Yes No 6 25/20 6 Yes No

Aperture Based Inverse Planning AAPM Summer School 2003

C506-E064. Full digital system. Printed in Japan A-NS

Monica Kishore. Medical Physics Graduate Program Duke University. Approved: Jennifer O Daniel, Co-Supervisor. Fang-Fang Yin, Co-Supervisor

Clinical helical tomotherapy commissioning dosimetry

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

QC Testing for Computed Tomography (CT) Scanner

Initial setup and subsequent temporal position monitoring using implanted RF transponders

v tome x m microfocus CT

OTC18 OVERHEAD TUBE CRANE SYSTEM

Acceptance Testing of a Digital Breast Tomosynthesis Unit

SUN NUCLEAR. EPIDose : An Overview of EPIDose and the EPIDose Process and Algorithm. corporation. Your Most Valuable QA and Dosimetry Tools

CR35-SP+ Computed Radiography (CR) System. Innovations in Digital Imaging

MobileDaRt Evolution MX8 Version

Changing the Shape of Nuclear Medicine

Ultimate DR flexibility

CHAPTER 6 QUALITY ASSURANCE OF VARIAN ON-BOARD IMAGER

Q3D. Speak to a 3D Specialist. CBCT 3D / Panoramic Imaging GENERAL DIMENSIONS. Suni Imaging Product Lines GET.

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

SmartRAD. Advanced Digital Radiography System

Multi-Access Biplane Lab

TECHNICAL DATA. GIOTTO IMAGE SDL/W is pre-arranged for Full Field Digital Biopsy examination with the patient in prone position.

Development of a Virtual Simulation Environment for Radiation Treatment Planning

YSF - 300/DAR i

ADVANCED MEDICAL SYSTEMS PTE LTD Singapore Malaysia India Australia

Commissioning and Calibrating a Linear Accelerator State-of-the-Art in 2010

Comparison of peripheral dose measurements using Ionization chamber and MOSFET detector

Transcription:

TOMOTHERAPY H SERIES TomoH, TomoHD and TomoHDA Systems Technical Specifications

The TomoTherapy H Series is designed to treat the entire spectrum of radiation therapy patients with enhanced speed, precise performance and ease of use. Installation is simple, with over 95% of existing vaults installed to date requiring minimal-to-no retrofitting. 1 Key Features and Benefits: VoLO Planning enables flexibility, speed and efficiency with real time interactive planning. CTrue Image guidance provides daily 3D CT target localization and enables margin reduction while sparing healthy tissue. TomoHelical and TomoDirect modalities deliver individualized treatments for both routine and complex indications. TomoEDGE spares more normal tissue while enabling increased throughput. 1. Data on file as of March 19, 2013 1. Complete Treatment System Overall dimensions Height Width Length Weight 8 ft., 3.5 in. (252.4 cm) 9 ft., 2.0 in. (279.6 cm) 15 ft., 3.25 in. (465.9 cm) 10,000 lbs. (4,536 kg) Lateral View: System dimensions Forward View: System dimensions Other dimensions Gantry depth Couch maximum height Couch minimum height Couch width Table top width Couch longitudinal travel 66.1 in (167.8 cm) Approx. 43 in (110 cm) above floor Approx. 24 in (60 cm) above floor 25.5 in (64.8 cm) 20.9 in (53.0 cm) Approx. 63 in (160 cm) 02 H Series Product Specifications

Rendered view of system in room (A, B, C correspond to room dimensions below) 2. Installation Minimum room size - requirements* Height (A) Length (B) Width (C) Typical schedule (receipt of system to first treatment) Commissioning 8 ft., 10.13 in. (269.6 cm) 19 ft., 6.75 in. (596.2 cm) 15 ft., 2.00 in. (462.4 cm) 21 days from installation to acceptance tests signed off System comes with pre-installed beam model that only needs to be verified by customer as part of commissioning. Customer is responsible for determining when the system is acceptable for clinical use. * Refer to the TomoTherapy Treatment System Site Planning Guide for details of room size requirements. 3. Treatment Vault Environment SPECIFICATION Line voltage, VAC Ambient room temperature Relative humidity REQUIREMENTS 480 volts, 3-phase; others may be supported 68-75 degrees Fahrenheit (20-24 degrees Celsius) 30% - 60%, noncondensing H Series Product Specifications 03

4. Mechanical Features SPECIFICATION Gantry Degrees of rotation Direction of rotation Accuracy of set angles Speed of rotation Controls Source to axis distance Mechanical to radiation isocenter offset Mechanical isocenter stability Position indicators Isocenter height Cooling PERFORMANCE Rotates around IEC-y axis, continuous rotation Clockwise viewed from the foot of the couch Within 0.1 degrees Between 1 and 5 RPM for treatment; 6 RPM for imaging Rotational speed set during treatment planning 85 cm Included in beam model (within accuracy 0.25 mm) < 0.4 mm 5-axis laser system 113 cm typical (dependent upon finished flooring) Integrated onboard cooling system eliminates need for facility-chilled water loop 5. Photon Beam SPECIFICATION Accelerator type Length Microwave Power Source Nominal dose rate at Dmax** Nominal Dmax** PERFORMANCE Standing Wave 0.3 meters 2.5 MW Magnetron 850 cgy/min 1.5 cm Percentage depth dose at 10 cm** Typical 61.4% Number of beamlets Treatment plan dependent; system capable of efficiently delivering tens of thousands of beamlets which allows for very high fidelity intensity modulation Nominal energy 6 MV, single energy Nominal spot size 2 mm Penumbra of treatment beam - IEC-y axis The 80% - 20% penumbra widths are approximately 4.9 mm, 4.6 mm, and 4.1 mm (respectively for the 5.0 cm, 2.5 cm, and 1.0 cm field widths). Field size range at isocenter IEC-y x IEC-x Selectable 1.0 cm x 40 cm (fixed) 2.5 cm x 40 cm (fixed) 5.0 cm x 40 cm (fixed) 1.0-2.5 cm x 40 cm (optional dynamic) 1.0-5.0 cm x 40 cm (optional dynamic) Treatment volume - TomoHelical Treatment volume - TomoDirect (optional) Maximum treatment volume length is approximately 135 cm with a typical couch height. The 40 cm wide MLC allows irradiation of all target points within a 40 cm diameter cylinder, throughout each 360º gantry rotation. Points outside a 40 cm cylinder can be irradiated from a reduced, location-specific, range of gantry angles. Maximum treatment volume length is approximately 135 cm with a typical couch height. Target points within a 40 cm diameter cylinder can be irradiated by beams from any user defined gantry angle throughout 360º. Points outside a 40 cm cylinder can be irradiated from a reduced, location specific, range of gantry angles. 04 H Series Product Specifications ** Performance based on 5 cm field size at SSD=85 cm.

Linear Accelerator (Linac) Integrated Shielding Target Primary Collimator Jaw Collimator Multileaf Collimator Accelerator and collimator subsystems Average MLC leakage Primary collimation Jaw collimation Jaw positions (per jaw) Axis of travel Speed of travel Basic dimensional description Multileaf collimation Number of leaves Basic dimensional description Mode of operation Axis of travel Speed of travel Resolution Leaf drive mechanism Position indicator 0.25% (typical) Tungsten block with rectangular, fixed aperture 0.5 cm, 1.25 cm or 2.5 cm from mid-line in static mode -1.5 cm (across mid-line) to 2.5 cm in optional dynamic mode IEC-y Jaws set to planned width in static mode Single jaw opening/closing at speed of couch at beginning/end of delivery when in optional dynamic mode 13.5 cm tungsten thickness 64 binary interlaced leaves (tongue and groove side profile) 10 cm leaf thickness in beam direction Binary leaves either fully in or fully out of beam path 1 axis, longitudinal direction (IEC-y) Binary leaf state changed within 20 msec 0.625 cm leaf widths in IEC-x direction at isocenter Pneumatic Continuous monitoring with interlock, checks that leaves open and close at correct time H Series Product Specifications 05

6. Dosimetry SPECIFICATION Monitor chamber type PERFORMANCE Full beam transmission, hermetically sealed dual chamber Monitor chamber precision Within 1% Monitor chamber linearity Within 1% Beam-off interlocks 7. CTrue Imaging Radiation System; Dose Monitoring, Patient Table Position; Gantry Angle; Computer Communications; Vault Door; Facility E-stops SPECIFICATION Geometry Dose per MVCT image (typical) Detector configuration Image resolution (xy) Slice spacing available Scan time Field of view (FOV) Source to detector distance Isocenter to detector distance PERFORMANCE Helical Fan-beam 0.5-3 cgy depending on resolution and body thickness Single row xenon ion chamber array used for image acquisition 512 x 512 (0.78 mm pixels) 1 mm, 2 mm, 3 mm, 4 mm, 6 mm reconstruction intervals Scan pitch dependent: Typically 2 minutes per 15 cm length at 3 mm slice spacing 39 cm diameter 145 cm 60 cm Image noise 2% - 4% Image uniformity Within 2.5% Spatial resolution Nominal 0.5 lp/mm at 10% MTF Contrast resolution 2% density for 2 cm object (typical) Image reconstruction algorithm Filtered backprojection Image reconstruction time Real-time; slice-by-slice at time of acquisition Image registration tools Application of adjustments obtained Frequency of correction for geometry flexion Image guidance mode MVCT/kVCT image overlay with adjustable checkerboard; manual or automatic registration (maximization of mutual information) using bone and/or soft tissue; translations and pitch/roll/yaw determination X, Y, Z translations applied via couch, roll applied via gantry as determined by image registration None required; rigid ring gantry platform Daily 3D MVCT matched with 3D kvct 06 H Series Product Specifications

Prostate visibility No high-z artifact Multi-planar image overlay Overlay images, structures, dose Common imaging and treatment subsystem 8. Safety Features Integrated treatment planning: Planning and treatment systems use a common database Integrated quality assurance: Patient-specific QA via a dedicated application on the planning station Integrated procedure verification: Built-in procedure verification in addition to DICOM/IHE compliant MOSAIQ and Aria OIS interfaces* Single database: Common database for planning, imaging and treatment data No plan data transfer: Planning data retrieved by treatment system from common database Common imaging and treatment beam source: Imaging geometry consistent with treatment geometry (imaging and treatment source are the same), thus avoiding the need for repeated geometric calibration of 2 different sources Fully enclosed gantry: Integrated gantry enclosures protecting the patient from beam delivery system components No auxiliary beam collimation: Integrated binary MLC (multileaf collimator) provides all beam collimation and modulation, removing the possibility of incorrect component installation and maintaining maximum physical patient clearance; also reduces handling of hazardous material No bending magnet: No beam bending required, therefore eliminating the possibility of geometry errors resulting from redirection of the beam No electron mode: The treatment system cannot be set to an unintended mode of delivery (note that helical IMRT with 6 MV x-rays can be planned to deliver treatments similar to electron mode treatments) Full system integration: Level of system integration results in software for all components being designed and tested in unison, reducing concerns of disparate system interfaces and compatibility concerns across products and across companies Noise eliminating intercom system: Facilitates clear two-way communication between the clinician and the patient, utilizing Digital Signal Processing technology, throughout the imaging and treatment process * Please contact Accuray for a current list of compatible software versions. H Series Product Specifications 07

9. TomoHelical Treatment Delivery Mode The TomoHelical delivery mode provides IMRT and 3D CRT treatment delivery in a continuous (360 ) helical pattern. The TomoHelical mode is suited to the majority of clinical situations, where rotational delivery and beam modulation enhance target dose conformality and uniformity. The user is able to create a treatment plan that defines dose goals and constraints for target and avoidance structures, the level of modulation for the plan, as well as the fractionation schedule. During treatment delivery, the linear accelerator completes multiple 360 rotations around the patient while the couch passes through the bore of the system, initiated by a single turn of the operator console key. The gantry rotates around the patient in TomoHelical delivery mode, delivering radiation in a continuous spiral pattern Fixed jaw and optional dynamic jaw (TomoEDGE ) modes are available with TomoHelical. With TomoEDGE, field width varies during delivery to increase dose gradient outside the target (also see section 5). Targets of up to 135 cm in length* can be treated, with no need to reposition the patient and with no field junctioning. 10. TomoDirect Treatment Delivery Mode (optional) The TomoDirect delivery mode provides IMRT and 3D CRT treatment via a discrete angle, non-rotational delivery mode. TomoDirect allows creation of treatment plans that include between 2 and 12 target-specific gantry angles. TomoDirect complements TomoHelical in situations where a fixed-angle delivery is most appropriate. During treatment delivery, beams are delivered sequentially with the couch passing through the bore of the system at an appropriate speed for each beam. The complete treatment delivery is initiated by a single turn of the operator console key. 2 12 discrete gantry angles can be used in TomoDirect delivery mode Fixed jaw and optional dynamic jaw (TomoEDGE) modes are available with TomoDirect. With TomoEDGE, field width varies during delivery to increase dose gradient outside the target (also see section 5). Targets of up to 135 cm in length* can be treated, with no need to reposition the patient and with no field junctioning. 11. High Performance Couch The High Performance Couch, with Medical Intelligence indexing system, provides sub-millimeter accuracy and precision in point-to-point and translational positioning. Clinical workflow is enhanced with ergonomically designed dual Couch Control Keypads mounted to each side of the couch. The Couch Control Keypads allow motorized patient position modification in the X, Y and Z directions with simple, single-handed operation. The custom patient couch has a high strength carbon-fiber top with an indexing system designed to accommodate immobilization systems from multiple vendors. 12. Laser Positioning System See High Performance Couch brochure for additional specification information. TomoTherapy H Series configuration includes stationary green lasers for virtual isocenter and moveable red lasers for patient positioning and registration. * Typical patient set-up; Actual treatment volume lengths are variable depending upon couch height. 08 H Series Product Specifications

13. Computing Hardware Includes the following items, housed in a rack enclosure (dimensions: 59 /150 cm H x 26 /66 cm W x 38 /97 cm D): The Generation 5, dual-node optimization cluster for dose calculation and optimization during treatment planning. The optional VoLO or High Performance (dual node) VoLO System for dose calculation and optimization during treatment planning. VoLO technology uses computer nodes with high-performance Graphics Processing Units (GPUs), coupled with Accuray s Non-Voxel Broad Beam (NVBB) algorithm. The Data Server and Storage Area Network (SAN), which stores data required to run the treatment system and deliver prescribed treatments to the patient. It also stores patient planning information (CT images, contours, dose volumes, and plans). The Data server is connected to the Optimization Server, Planning Stations, Operator Station and the Treatment Delivery System. The SAN provides 1.8 TB of storage in a RAID 6 configuration. The TomoGateway system hardware enables remote system monitoring by Accuray Technical Support (note: additional software may be required). Tape drive system for database backup. LCD display for administration of the Optimizer/Data Server assembly. Uninterruptible Power Supplies (UPS) to support the complete Optimizer/Data Server assembly; Network switch and firewalls. 14. Planning Stations Two TomoTherapy Planning Stations allow the definition and management of treatment plans and initiation of plan optimization. Delivery Quality Assurance (DQA) tools are also provided on the Planning Station platform. The Planning Stations further include the Data Management System application software, for archiving and management of patient data. An Uninterruptible Power Supply, high-resolution LCD monitor, keyboard, mouse, and required cables are included with each Planning Station. A color printer for printing treatment plans and reports is also included. 15. Operator Station An optional third Planning Station is available for purchase. One TomoTherapy Operator Station, which connects to the treatment system database and provides control of CTrue MVCT imaging, patient treatment and quality assurance delivery, procedure verification functionality and delivery of calibration procedures. Operator Station Couch Control is included, allowing patient shifts to be made remotely from the Operator Station after image registration. The Operator Station is provided with a color printer capable of printing CTrue images and treatment data, plus an LCD monitor, keyboard, mouse, and required cables. 16. Planned Adaptive Software (optional) The Planned Adaptive software license enables simple and effective dose verification for single or multiple treatment fractions, via daily MVCT images. The impact on delivered dose of changes in patient anatomy throughout the treatment course can be monitored and quantified using 3D isodose images, dose difference maps and dose volume histograms. H Series Product Specifications 09

17. Remote Software Solutions Remote Planning and TomoPortal (optional) Remote Planning securely and easily provides fully functional operation of the TomoTherapy Planning Station application from outside of the TomoTherapy H Series Treatment System network, via the internet. It allows a remote user to operate the Planning Station application and develop plans without being physically present in the facility where the TomoTherapy H Series Treatment System is installed. The TomoPortal application also resides on the same Remote Software Solutions computer node as the Remote Planning application. The TomoPortal Remote Viewer securely and easily provides a web-enabled link to patient information stored in the TomoTherapy H Series Treatment System. It is possible to review a plan, registration, and treatment data from down the hall or across a continent. Typical configurations include server computer hardware with one or two Remote Planning licenses and two TomoPortal licenses. Note: These features do not allow remote operation of the radiation delivery system. Hospital Network Patient Archives DICOM-RT Import DICOM-RT Export Planning CT Import Oncology IS Patient Data Transfer Standard system interfaces 18. System Interfaces DICOM Export The DICOM Export Data Services Package allows the following DICOM objects to be sent from the TomoTherapy H Series Treatment System to third-party systems and clinical/research databases: DICOM-CT Image Set DICOM-RT Structure Set DICOM-RT Dose DICOM-RT Plan 10 H Series Product Specifications

OIS Connect (optional) The OIS Connect software provides the ability to interface atomotherapy H Series Treatment System to a compatible Oncology Information System (OIS). Elekta Mosaiq and Varian Aria systems are currently supported. The software facilitates greater integration of the TomoTherapy H Series Treatment System into the radiation oncology department, by: Allowing scheduling of TomoTherapy treatments on the OIS; Providing automatic capture of TomoTherapy procedures on the OIS; Aiding in charge capture and billing (where applicable); Aiding in integrating TomoTherapy treatments into patients electronic medical records, via the OIS. The OIS Connect software is based on DICOM-RT Worklist communication, as specified in DICOM Supplements 74 and 96. Network Data Storage (optional) This feature allows patient archives created on the TomoTherapy H Series Treatment System to be sent to, or retrieved from, a storage location outside of the treatment system network. Network Data Storage provides configuration of the system firewall, workstation configuration and FTP system set up for data transfer via network. Patient Data Transfer (optional) Patient Data Transfer allows the transfer of patient data from the TomoTherapy H Series Treatment System upon which it is installed, to another TomoTherapy treatment system. Patient Data Transfer provides configuration of the system firewall, workstation configuration and FTP system set up for data transfer via network, and an external USB hard drive for physical data transfer. 19. Quality Assurance TomoTherapy Quality Assurance (TQA ) Essentials Package (Machine quality assurance) The TQA application is a calendar-based productivity tool that simplifies the collection and analysis of machine performance data for the TomoTherapy H Series Treatment System. The application leverages internally-generated data to provide results quickly and easily. The TQA application offers trending and reporting of many system and dosimetric parameters that allow physicists to monitor the performance of the TomoTherapy H Series Treatment System. All data may be exported. The Essentials Package includes the Basic Dosimetry, Air Scan and System Monitor modules as well as TomoLink for automated remote monitoring of system operation and performance. The optional TQA Total package includes extra modules such as Daily QA, Helical and Static Step Wedge, as well as modules for QA of dynamic jaw functionality. 20. Installation Services See TQA brochure for more information. Includes: Pre-installation Site Planning and Project Management services; Installation and commissioning; Completion of Acceptance Test Procedure (ATP) and system handover. H Series Product Specifications 11

UNITED STATES ASIA EUROPE Accuray Corporate Headquarters 1310 Chesapeake Terrace Sunnyvale, CA 94089 USA Tel: +1.408.716.4600 Toll Free: 1.888.522.3740 Fax: +1.408.716.4601 Email: sales@accuray.com Accuray Incorporated 1240 Deming Way Madison, WI 53717 USA Tel: +1.608.824.2800 Fax: +1.608.824.2996 Accuray Japan K.K. Shin Otemachi Building 7F 2-2-1 Otemachi, Chiyoda-ku Tokyo 100-0004 Japan Tel: +81.3.6265.1526 Fax: +81.3.3272.6166 Accuray Asia Ltd. Units 910-11, Ocean Centre Harbour City 5 Canton Road, T.S.T Hong Kong Tel : +852.2247.8688 Fax : +852.2175.5799 Accuray Accelerator Technology (Chengdu) Co., Ltd. No. 8, Kexin Road Hi-Tech Zone (West Area) Chengdu 611731 Sichuan China Accuray International Sarl Route de la Longeraie 7 9 CH 1110 Morges Switzerland Tel: +41.21.545.9500 Fax: +41.21.545.9501 Important Safety Information Most side effects of radiotherapy, including radiotherapy delivered with Accuray systems, are mild and temporary, often involving fatigue, nausea, and skin irritation. Side effects can be severe, however, leading to pain, alterations in normal body functions for example, urinary or salivary function), deterioration of quality of life, permanent injury, and even death. Side effects can occur during or shortly after radiation treatment or in the months and years following radiation. The nature and severity of side effects depend on many factors, including the size and location of the treated tumor, the treatment technique (for example, the radiation dose), and the patient s general medical condition, to name a few. For more details about the side effects of your radiation therapy, and to see if treatment with an Accuray product is right for you, ask your doctor. 2017 Accuray Incorporated, All Rights Reserved. The stylized Accuray logo, TomoTherapy, H Series, Tomo, TomoH, TomoHD, TomoHDA, TomoEDGE, TomoHelical, TomoDirect, H Art, and PlanTouch are trademarks or registered trademarks of Accuray Incorporated, in the United States and other countries and may not be used or distributed without written authorization from Accuray Incorporated. Use of Accuray Incorporated s trademarks requires written authorization from Accuray Incorporated. Other trademarks used and identified herein are the property of their respective owners. MKT-TT-0317-0207