R3132/3162. Advanced Test Equipment Rentals ATEC (2832) R3132 : 9kHz to 3GHz R3162 : 9kHz to 8GHz

Similar documents
Spectrum Analyzers R3132/3132N/3162 R3132/3132N/3162. Low cost, high performance. General-Purpose Spectrum Analyzer Adaptable to Various Applications

One Spectrum Analyzer for Versatile Applications

R3131A. Advanced Test Equipment Rentals ATEC (2832) A personal spectrum analyzer for use in diverse applications R3131A

U3661. Spectrum Analyzer. For field maintenance of microwave radio facilities, and digital mobile communication U3661

khz to 2.9 GHz Spectrum Analyzer

2.9GHz SPECTRUM ANALYZER

GA GHz. Digital Spectrum Analyzer

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

Specification RIGOL. 6 Specification

Chapter 5 Specifications

R3264/3267/3273 Spectrum Analyzers

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer

GA GHz. Digital Spectrum Analyzer

Digital Spectrum Analyzer GA40XX Series

Spectrum Analyzers U3771/3772. Handling frequencies of up to 43 GHz!! Our new microwave spectrum analyzer, ideal for field use, is now available.

DSA700 Series Spectrum Analyzer

U3771/3772 Spectrum Analyzers

khz to 2.7 GHz Spectrum Analyzer

DSA800. No.1 RIGOL TECHNOLOGIES, INC.

HZ530 Near-Field Probe Set

Spectrum Analyzers 2680 Series Features & benefits

Complimentary Reference Material

Agilent E7400A Series EMC Analyzers

SPECTRUM ANALYZERS. MS2602A 100 Hz to 8.5 GHz GPIB SPECTRUM ANALYZER

Agilent ESA-L Series Spectrum Analyzers

R&S ESCI/ESCI7 EMI Test Receiver Specifications

Spectrum Analyzers U3641/3641N/3641PHS U3641/3641N/3641PHS. Spectrum Analyzer. Light Weight, Compact, Battery Operated Spectrum Analyzer

Spectrum Analyzers U3771/3772. Handling frequencies of up to 43 GHz!! Our new microwave spectrum analyzer, ideal for field use, is now available.

DSA800. No.2 RIGOL TECHNOLOGIES, INC. All-Digital IF Technology 9 khz GHz Frequency Range

DSA800 RIGOL TECHNOLOGIES, INC.

Spectrum Analyzer RIGOL TECHNOLOGIES,INC.

Agilent N9320B RF Spectrum Analyzer

6.2GHz SPECTRUM ANALYZER

Spectrum Analyzer RIGOL TECHNOLOGIES,INC.

Network Analyzers. R3765G/3767G Series. R3765G/67G Series Network Analyzers. 300 khz to 3.8 GHz/300 khz to 8 GHz

No.1. Batronix LEADING PROGRAMMING AND MEASUREMENT SOLUTIONS

Agilent 8560 E-Series Spectrum Analyzers

Spectrum Analyzers U3771/3772. Handling frequencies of up to 43 GHz!! Our new microwave spectrum analyzer, ideal for field use, is now available.

Spectrum Analyzers U3741/3751. Compact Design with High Performance Pioneering 3 GHz/8 GHz Spectrum Analyzers are Now Available!

Spectrum Analyzer R&S FS300

R3671/3681 Signal Analyzers

Spectrum Analyzer RIGOL TECHNOLOGIES,INC.

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

R3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation

Spectrum Analyzers Series 1 khz to 26.5 GHz Spectrum Analyzers. Advanced Test Equipment Rentals ATEC (2832)

HP 8560 E-Series Spectrum Analyzers Technical Specifications

ESA-E Series Spectrum Analyzer

Agilent N9343C Handheld Spectrum Analyzer (HSA)

Keysight N9320B RF Spectrum Analyzer

Model 7000 Series Phase Noise Test System

Spectrum Analyzer RIGOL TECHNOLOGIES,INC.

R&S FSC Spectrum Analyzer Specifications

Spectrum Analyzer RIGOL TECHNOLOGIES,INC.

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

Spectrum Analyzers R3465/3463 R3465/3463. Modulation Spectrum Analyzers. Measurement For Digital Mobile Communications

Agilent N9342C Handheld Spectrum Analyzer (HSA)

RIGOL TECHNOLOGIES, INC.

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

R&S FSV Signal and Spectrum Analyzer Specifications

R3765CG/3767CG Network Analyzer

R&S ESRP EMI Test Receiver Specifications

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz

FREEDOM Communications System Analyzer R8100 DATA SHEET

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Spectrum Analyzer FSL

S3532 Series Spectrum Analyzer Datasheet

No.2 RIGOL TECHNOLOGIES, INC.

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

FREEDOM Communications System Analyzer R8000C DATA SHEET

R&S FSV Signal Analyzer Specifications

Agilent N9322C Basic Spectrum Analyzer

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

FREEDOM Communications System Analyzer R8600 DATA SHEET

Spectrum Analyzer FSU

Handheld 3.3GHz Spectrum Analyzer

FREEDOM Communications System Analyzer R8000C DATA SHEET

APPH6040B / APPH20G-B Specification V2.0

Keysight N9320B RF Spectrum Analyzer

Handheld Spectrum Analyzer R&S FSH3

Spectrum Analyzer. Distribution in the UK & Ireland

Measuring Receiver FSMR

No.2 RIGOL TECHNOLOGIES, INC.

FREEDOM Communications System Analyzer R8100 DATA SHEET

Advanced Test Equipment Rentals ATEC (2832)

RIGOL TECHNOLOGIES, INC.

SPECTRUM ANALYZERS. MS710C/D/E/F 10 khz to 23 GHz (18 to 140 GHz) GPIB SPECTRUM ANALYZER

R&S FSWP Phase Noise Analyzer Specifications

SVA1000X Series Spectrum & Vector Network Analyzer

ESU EMI Test Receiver

Handheld Spectrum Analyzer R&S FSH3

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

TECHNICAL SPECIFICATION FOR RF (TEST &MEASUREMENT) DEVICE

2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency

Spectrum Analyzer R&S FSP

RADIO COMMUNICATIONS TEST INSTRUMENTS

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

FREEDOM Communications System Analyzer R8100 DATA SHEET

Agilent ESA-L Series Spectrum Analyzers

NETWORK ANALYZERS. MS4630B 10 Hz to 300 MHz NETWORK ANALYZER GPIB. For Fast Evaluation of IF Filters and Resonators

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) R3132/3162 Spectrum Analyzer R3132 : 9kHz to 3GHz R3162 : 9kHz to 8GHz One Spectrum Analyzer For Versatile Applications R3132/3162

The R3132/3162 series spectrum analyzers offer the measurement capabilities and performance. For various applications, such as Cable TV, EMC measurement and Digital Mobile Communications, the R3132/ 3162 can be customized by selection from available options. Features 7Frequency range : R3132 : 9kHz to 3GHz R3162 : 9kHz to 8GHz 7Signal purity : 105dBc/Hz 20kHz offset 100dBc/Hz 10kHz offset 7Total level accuracy : Maximum ±1.5dB 7High-speed GPIB effective for system construction 7High speed measurement : 20 traces per second 76.5-inch TFT color LCD 7Built-in frequency counter 73GHz tracking generator (option) 7Floppy disc for data saving 7Large numeric display for measurement results (In counter and power measurement mode) 7Input impedance 75Ω model : R3132N Options 7Narrow-band resolution bandwidth : 30Hz, 100Hz, 300Hz and 200Hz (EMI bandwidth) 7High-stability frequency reference : Aging rate 1 10-7 /year 7High-speed time domain sweep : 50µs/10div. (100ns resolution) 7Tracking generator : 100kHz to 3GHz Basic functions Basic functions are reinforced so that R3132/3162 can be used in various fields. For example, the internal automatic calibration function guarantees the total level accuracy of ±1.5dB, level correction factor can be stored in the internal memory, DDS is employed to improve frequency reading accuracy, and frequency span error is lowered to less than 1%. The R3132/3162 offer wider dynamic range and lower 2nd and 3rd distortion by improving 1dB compression point. As a result of increasing the sweep repetition cycles by improving the synthesized local oscillator, 20 traces/second (typ.) data rewriting becomes possible, enabling far more real-time waveform measurement. high speed GPIB increase, the throughput of automatic measurement. For many applications For EMI precompliance measurement, 6-dB bandwidth filters for 9kHz, 120kHz and 1MHz as well as QP detector are equipped as standard. Optional 200Hz narrow RBW filter can be added. For high-speed time domain measurement function which is indispensable for mobile communications, optional 50µs sweep is effective. By using the double-screen display function, you can specify the rising/falling edge of TDMA waveform and display the magnified image. The R3132/3162 series spectrum analyzer has ACP and OBW operation function indispensable for evaluating the transmission characteristic of radio system. With various other functions such as AUTO TUNE, 1Hz resolution frequency counter, dbc/hz, %AM, and PASS/FAIL test by limit value, the R3132/3162 series can easily perform several types of measurements. Even for signals which are lower in level than the average noise level, the preamplifier ensures level calibrated, high-accuracy measurement. For measuring the attenuation characteristic of filters or the frequency characteristic of cables, etc., built-in tracking generator is available as option. Because the output level can be set in a wide range, it is possible to measure amplifier gain, frequency response, etc. Easy-operation interface The high-resolution, 6.5-inch TFT color LCD realizes easy-to-see display of data. VGA output is provided for external display. Measured waveform data and setting condition can be saved in or recalled from the internal memory. Using the floppy disc drive which is equipped as standard, you can manage more number of measurement data. Text data or Bitmap data on floppy disc are also useful for making documents on a personal computer. As the hard-copy function is provided to ESC/P. ESC/P-R and PCL, measured data can be printed out on general-purpose printers. GPIB and RS232 are equipped as standard.

R3132 Specifications Frequency Frequency range : 9kHz to 3GHz Frequency reading accuracy : ± (Reading of frequency Frequency reference accuracy (Start, stop, center frequency, + Span 1% + Resolution bandwidth 15% + 60Hz) marker frequency) Counter Resolution : 1Hz to 1kHz ± (Marker frequency Frequency reference accuracy + 1LSD) Frequency reference accuracy: Stability : ±2 10-6 /year, ±1 10-7 /year (Option) Frequency span Range : ±1 10-5 (0 C to 50 C) 1kHz to 3GHz, 0Hz ±1% Residual FM : 60Hzp-p 0.1s Amplitude accuracy Frequency response After auto calibration Preamplifier OFF : ±0.5dB (100kHz to 3GHz, ATT=0dB) ±1dB (100kHz to 2.7GHz) ±2dB (9kHz to 3GHz) Preamplifier ON : ±1dB (100kHz to 2.7GHz) ±2dB (9kHz to 3GHz) Calibration signal level accuracy : IF gain error : Scale indication accuracy Log : Linear : -20dBm±0.3dB After auto calibration ±0.5dB (0 to -20dB) ±1.5dB/90dB ±1dB/10dB ±0.2dB/1dB ±5% of reference level Input ATT switching error : ±0.3dB (for 0 to 50dB, with respect to 30 MHz/10dB) Signal purity : -105dBc/Hz (20kHz offset) -100dBc/Hz (10kHz offset) Resolution bandwidth switching level error : Resolution bandwidth (3dB) Range : 1kHz to 3MHz, 1-3-10 sequence, 30Hz to 300Hz (Option) <± 20 %, 1kHz to1mhz <± 25 %, 3MHz 6dB bandwidth : 1MHz, 120kHz, 9kHz, 200Hz (Option) Video bandwidth : 10Hz to 3MHz 1-3-10 sequence Total level accuracy : ±1.5dB (REF=-50 to 0dBm, ATT=10dB, 2dB/div, Sweep RBW=300kHz, f >100kHz, after auto calibration) Sweep time : 20ms to 1000s, 50µs to 1s (Option) <±1% Amplitude range Measuring range : +30dBm to the average of displayed noise level Trigger mode : Sweep mode : FREE RUN, LINE, VIDEO, EXT, TV REPEAT, SINGLE Maximum input level (Input ATT 5dB) Preamplifier OFF : +30dBm, ±50VDC max. Preamplifier ON : +13dBm, ±50VDC max. Indication range 10 10div 10, 5, 2, 1dB/div Linear: 10% of the reference level/div. Reference level range Preamplifier OFF (Input ATT: 0 to 50 db) -64dBm to +40dBm (0.1dB step) Linear: 141.1µV to 22.36V Preamplifier ON (Input ATT : 0 to 10 db) -84.4dBm to -20.4dBm (0.1dB step) Linear: 13.47µV to +22.35mV Input ATT range : 0 to 50dB (5dB step) Dynamic range Average noise level : RBW 1 khz, VBW 10Hz, input ATT 0 db, for 1 MHz or more Preamplifier OFF : -118dBm + 2f (GHz) db Preamplifier ON : -132dBm + 3f (GHz) db 1dB gain compression : At 10MHz or more Preamplifier OFF : >0dBm (mixer input level) Preamplifier ON : >-30dBm (RF input level) Spurious response : Preamplifier OFF 2nd-order harmonic distortion : -80dBc (Mixer input -30dBm, f 100MHz) 2 signal, 3rd-order intermodulation distortion : -80dBc (Mixer input -30dBm, f 100MHz, Offset > 10kHz) Residual response : When input ATT 0dB and 50Ω terminated Preamplifier OFF : -100dBm Preamplifier ON : -105dBm I/O RF input Connector : Impedance : VSWR N type female R3132 ; 50Ω (nominal), R3132N ; 75Ω (nominal) Preamplifier OFF : <1.5 : 1 (100kHz to 2GHz) <2 : 1 (9kHz to 3GHz) Input ATT : 5 to 50dB Preamplifier ON : <2.5 : 1 (9kHz to 3GHz) Probe power : ±12V, 4pin connector Calibration output signal : BNC female 30MHz, -20dBm 10MHz reference input : BNC female, 50Ω 0dBm to +16dBm External trigger input : BNC female Sound output (demodulated audio) : GPIB interface : Serial interface : Printer interface : Video out : Floppy disc : Small monophonic jack IEEE-488 specification BUS connector D-sub 9pin D-sub 25pin, ESC/P, ESC/P-R, PCL VGA (15pin, female) 3.5 inch, MS-DOS format General specification Operating temperature : 0 to +50 C Humidity RH 85% or less Storage temperature : -20 to +60 C, RH 85% or less Power supply : 100/200 VAC switchable 100VAC : 100 to 120VAC, 50 to 60Hz 200VAC : 200 to 240VAC, 50 to 60Hz Dimensions : 424 (W) 177 (H) 300 (D)mm (without feet and connectors)

R3162 Specifications Frequency frequency range : 9kHz to 8GHz Frequency range Band 9kHz to 3.4GHz 0 3.2GHz to 7.5GHz 1-6.5GHz to 8GHz 1+ Frequency reading accuracy : ± (Reading of frequency Frequency reference accuracy (Start, stop, center frequency, + Span 1% + Resolution bandwidth 15% + 60Hz) marker frequency) Counter Resolution : 1Hz to 1kHz ± (Marker frequency Frequency reference accuracy + 1LSD) Frequency reference accuracy : Stability : ±2 10-6 /year, ±1 10-7 /year (Option) ±1 10-5 (0 C to 50 C) Frequency span Range : 1kHz to 8GHz, 0Hz ±1% Residual FM : 60Hzp-p 0.1s Signal purity : -105dBc/Hz (20 khz offset) -100dBc/Hz (10 khz offset) Resolution bandwidth (3dB) Range : 1kHz to 3MHz, 1-3-10 sequence, 30Hz to 300Hz (Option) <± 20 %, 1kHz to1mhz <± 25 %, 3MHz 6dB bandwidth : 1MHz, 120kHz, 9kHz, 200Hz (Option) Video bandwidth : 10Hz to 3MHz Amplitude range Measuring range : Maximum input level (Input ATT 5dB) Preamplifier OFF : +30dBm, 0VDC max. Preamplifier ON : +13dBm, 0VDC max. Indication range Linear: 1-3-10 sequence +30dBm to the average of displayed noise level 10 10div 10, 5, 2, 1dB/div 10% of the reference level/div. Reference level range Preamplifier OFF (Input ATT: 0 to 75dB) -64dBm to +40dBm (0.1dB step) Linear: 141.1µV to 22.36V Preamplifier ON (Input ATT: 0 to 10dB) -84.4dBm to -20.4dBm (0.1dB step) Linear: 13.47µV to +22.35mV Input ATT range : Dynamic range 0 to 75dB (5dB step) Average noise level : RBW 1 khz, VBW 10Hz, input ATT 0 db, for 1MHz or more Preamplifier OFF : Band 0 : -118 dbm + 2f (GHz) db Band 1- : -115dBm Band 1+ : -115dBm Preamplifier ON : -132dBm + 3f (GHz) db (At 1MHz to 3.4GHz) 1dB gain compression : At 10MHz or more Preamplifier OFF : >0dBm (mixer input level) Preamplifier ON : >-30dBm (RF input level) Spurious response : Preamplifier OFF 2nd-order harmonic distortion : Frequency range Mixer input Distortion level 100MHz to 1.8GHz -30dBm -80dBc 1.8GHz to 3.4GHz -10dBm -80dBc >3.4GHz -10dBm -100dBc 2 signal, 3rd-order intermodulation distortion : -80dBc (Mixer input -30dBm, f 100MHz, Offset > 10kHz) Image/multiple/band external response : -70dBc Residual response : When input ATT 0dB and 50Ω terminated Preamplifier OFF : -100dBm (1MHz to 3.4GHz) -90dBm (>3.4GHz) Preamplifier ON : -105dBm (1MHz to 3.4GHz) Amplitude accuracy Frequency response After auto calibration, After pre-selector peak adjustment Preamplifier OFF : ±0.5dB (100kHz to 3GHz, ATT=0dB) ±1dB (100kHz to 2.7GHz) ±2dB (9kHz to 3.4GHz) ±2dB (3.2GHz to 8GHz) Preamplifier ON : ±1dB (100kHz to 2.7GHz) ±2dB (9kHz to 3.4GHz) Calibration signal level accuracy : IF gain error : Scale indication accuracy Log : Linear : -20dBm±0.3dB After auto calibration ±0.5dB (0 to -20dB) ±1.5dB/90dB ±1dB/10dB ±0.2dB/1dB ±5% of reference level Input ATT switching error : ±0.3dB (for 0 to 50dB, with respect to 30 MHz/10dB) Resolution bandwidth switching level error : Total level accuracy : ±1.5dB (REF=-50 to 0dBm, ATT=10dB, 2dB/div, Sweep RBW=300kHz, f >100kHz, after auto calibration) Sweep time : 20ms to 1000s, 50µs to 1s (Option) <±1% Trigger mode : Sweep mode : I/O RF input Connector : Impedance : VSWR FREE RUN, LINE, VIDEO, EXT, TV REPEAT, SINGLE N type female 50Ω (nominal) Preamplifier OFF : <2 : 1 (9kHz to 8GHz) Input ATT : 10 to 75dB Preamplifier ON : <2.5 : 1 (9kHz to 3.4GHz) Probe power : ±12 V, 4pin connector Calibration output signal : BNC female, 50Ω 30MHz, -20dBm 10 MHz reference input : BNC female, 50Ω 0dBm to +16dBm External trigger input : BNC female Sound output (demodulated audio) : GPIB interface : Serial interface : Printer interface : Video out : Floppy disc : Small monophonic jack IEEE-488 specification BUS connector D-sub 9pin D-sub 25pin, ESC/P, ESC/P-R, PCL VGA (15pin, female) 3.5 inch, MS-DOS format General specification Operating temperature : 0 to +50 C Humidity RH 85% or less Storage temperature : -20 to +60 C, RH 85% or less Power supply : Dimensions : 100/200 VAC switchable 100VAC : 100 to 120VAC, 50 to 60Hz 200VAC : 200 to 240VAC, 50 to 60Hz 424 (W) 177 (H) 300 (D)mm (without feet and connectors)

Advantest Corporation Shinjuku-NS building, 4-1 Nishi-Shinjuku 2-chome Shinjuku-ku, Tokyo 163-0880, Japan Tel: +81-3-3342-7500 Fax:+81-3-5381-7661 http://www.advantest.co.jp Advantest (Singapore) Pte. Ltd. 438A Alexandra Road, #8-03/06 Alexandra Technopark Singapore 119967 Tel: +65-274-3100 Fax:+65-274-4055 Tektronix Inc. (North America) P. O. Box 500 Howard Vollum Industrial Park Beaverton, Oregon 97077-0001 U. S. A. Tel:+1-800-426-2200 Fax:+1-503-627-4090 Rohde & Schwarz Engineering and Sales GmbH (Europe) Mühldorfstr. 15 (P. O. B. 80 14 29, D-81614 Munich) D-81671 München Tel:+49-89-4129-3711 Fax:+49-89-4129-3723 1999 ADVANTEST CORPORATION Printed in Japan Bulletin No.R3132/3162Z-331E Jan. 99A