Technology Note ZEISS LSM 880 with Airyscan

Similar documents
Application Note. The New 2D Superresolution Mode for ZEISS Airyscan 120 nm Lateral Resolution without Acquiring a Z-stack

Travel to New Dimensions- LSM 880. The Resolution of a Microscope is limited. The Resolution of a Microscope is limited. Image. Image. Object.

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

3D light microscopy techniques

The Zeiss AiryScan System, Confocal Four.

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Practical work no. 3: Confocal Live Cell Microscopy

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Inside the LSM 880 NLO + Airyscan

LSM 710 Confocal Microscope Standard Operation Protocol

Shreyash Tandon M.S. III Year

Development of a High-speed Super-resolution Confocal Scanner

Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement

Confocal Microscopy. (Increasing contrast and resolu6on using op6cal sec6oning) Lecture 7. November 2017

3D light microscopy techniques

1 Co Localization and Working flow with the lsm700

Training Guide for Carl Zeiss LSM 880 with AiryScan FAST

BASICS OF CONFOCAL IMAGING (PART I)

Megapixel FLIM with bh TCSPC Modules

Multifluorescence The Crosstalk Problem and Its Solution

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Bio 407. Applied microscopy. Introduction into light microscopy. José María Mateos. Center for Microscopy and Image Analysis

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Technology Note. The Airyscan Detector from ZEISS Confocal Imaging with Improved Signal-to-Noise Ratio and Superresolution

Imaging Retreat - UMASS Customized real-time confocal and 2-photon imaging

Basics of confocal imaging (part I)

LSM 780 Confocal Microscope Standard Operation Protocol

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Confocal and 2-photon Imaging. October 15, 2010

Instant super-resolution imaging in live cells and embryos via analog image processing

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

ADVANCED METHODS FOR CONFOCAL MICROSCOPY II. Jean-Yves Chatton Sept. 2006

Zeiss 880 Training Notes Zen 2.3

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

Microscopy from Carl Zeiss

Leica SP8 Resonant Confocal. Quick-Start Guide

Things to check before start-up.

Confocal imaging on the Leica TCS SP8. 1) Turn the system on. 2) Use TCS user account. 3) Start LAS X software:

Zeiss 780 Training Notes

Leica TCS SP8 Quick Start Guide

Nature Methods: doi: /nmeth Supplementary Figure 1. Schematic of 2P-ISIM AO optical setup.

Digital Camera Technologies for Scientific Bio-Imaging. Part 2: Sampling and Signal

IC 2 S High Performance Objectives

Confocal, hyperspectral, spinning disk

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Zeiss LSM880 Operating Instructions. UTMB Optical Microscopy Core Jan. 16, 2018

Operating Instructions for Zeiss LSM 510

Reflecting optical system to increase signal intensity. in confocal microscopy

Confocal Laser Scanning Microscopy

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

INTRODUCTION TO MICROSCOPY. Urs Ziegler THE PROBLEM

The DCS-120 Confocal Scanning FLIM System

Confocal Microscopy. Kristin Jensen

Competition for the Confocal Microscope?

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Zeiss LSM 780 Protocol

Confocal, Airyscan and Structured Illumination Superresolution microscopy Mayandi Sivaguru

LSM 800 Confocal Microscope Standard Operation Protocol

Zeiss LSM 880 Protocol

MULTIPHOTON MICROSCOPY. Matyas Molnar Dirk Pacholsky

EUV microscopy - a user s perspective Dimitri Scholz EUV,

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

LSM 510 META in Chang Gung University

Rates of excitation, emission, ISC

Multicolor 4D Fluorescence Microscopy using Ultrathin Bessel Light sheets

Leica SP8 TCS Users Manual

Spectral Imaging with the Opterra Multipoint Scanning Confocal

Contents. Introduction

NIH Public Access Author Manuscript Opt Lett. Author manuscript; available in PMC 2010 August 9.

Supplemental Method Information Zeiss LSM710

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

ZEN 2012 SP5 black edition Hotfix 12

ANSWER KEY Lab 2 (IGB): Bright Field and Fluorescence Optical Microscopy and Sectioning

Fast, high-contrast imaging of animal development with scanned light sheet based structured-illumination microscopy

DIC Imaging using Laser Scanning Microscopes (LSMs) on Axio Imager Stands

Introduction to light microscopy

Axio Zoom.V16 The Fluorescence Zoom Microscope for Large Fields

Non-Descanned FLIM Detection in Multiphoton Microscopes

Supplementary Information. Stochastic Optical Reconstruction Microscopy Imaging of Microtubule Arrays in Intact Arabidopsis thaliana Seedling Roots

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

LSM 510 Meta Training Notes

MOM#3: LIGHT SHEET MICROSCOPY (LSM) Stanley Cohen, MD

長庚大學共軛焦顯微鏡課程 長庚大學共軛焦顯微鏡課程. Spot light 長庚大學

Fundamentals of Light Microscopy II: Fluorescence, Deconvolution, Confocal, Multiphoton, Spectral microscopy. Integrated Microscopy Course

Multi-channel imaging cytometry with a single detector

LSM 510 Training Notes

ZEISS LSM 710 NLO Multiphoton microscope Manual/Quick guide

Introduction to light microscopy

TCSPC at Wavelengths from 900 nm to 1700 nm

Topics. - How to calibrate the LSM scanner. - How to clean the microscope. - How to adjust the pinhole alignment. - How to adjust the Collimator

BIOIMAGING AND OPTICS PLATFORM EPFL SV PTBIOP LASER SCANNING CONFOCAL MICROSCOPY PRACTICAL CONSIDERATIONS

Introduction to light microscopy

Practical Flatness Tech Note

Flatness of Dichroic Beamsplitters Affects Focus and Image Quality

Multidimensional Imaging with the Opterra Multipoint Scanning Confocal System

STORM/ PALM ANSWER KEY

Dynamic Confocal Imaging of Living Brain. Advantages and risks of multiphoton microscopy in physiology

Transcription:

Technology Note ZEISS LSM 880 with Airyscan Introducing the Fast Acquisition Mode

ZEISS LSM 880 with Airyscan Introducing the Fast Acquisition Mode Author: Dr. Annette Bergter Carl Zeiss Microscopy GmbH, Germany Joseph Huff, PhD Carl Zeiss Microscopy, LLC, Thornwood, NY, USA Date: April 2016 In August 2014, ZEISS introduced Airyscan, a new detector concept for confocal laser scanning microscopy (LSM). Airyscan is a 32 channel GaAsP-PMT area detector, positioned at the pinhole-plane of an LSM. Using Airyscan, additional light and spatial information is collected beyond that of a typical LSM image, resulting in substantial and simultaneous improvements in spatial resolution and signal-to-noise ratio. The introduction of the Fast mode for Airyscan represents the next innovation step for LSM imaging. Airyscan detector technology is utilized along with an illumination shaping approach to enhance acquisition speeds by four times. Airyscan affords researchers access to superresolution, increased signal-to-noise ratio and increased acquisition speeds simultaneously without the traditional compromises. Laser Scanning Microscopy The Confocal Laser Scanning Microscope (LSM) has become one of the most popular instruments in basic biomedical research for fluorescence imaging. The main reason LSM has become so popular is that the technique affords researchers images with high contrast and a versatile optical sectioning capability to investigate three dimensional biological structures [1]. The optical sectioning ability of an LSM is a product of scanning a diffraction limited spot, produced by a focused laser spot, across a sample to create an image one point at a time. The generated fluorescence from each point is collected by the imaging objective and results from fluorophores in the sample that reside both in the desired plane of focus and in out of focus planes. In order to separate the fluorescence emitted from the desired focal plane, an aperture (pinhole) is positioned in the light path to block all out of focus light from reaching the detector (traditionally a PMT) [2]. Based on the application needs, LSM offers tremendous flexibility to fit experimental requirements, such as the choice of the excitation laser wavelengths and scanner movement; magnification and resolution of objective lenses as well as the type and arrangement of the detectors. Hence LSMs can be used to image diverse samples from whole organisms to large tissue sections to single cells and their compartments, labeled with numerous fluorescent markers of diverse emission intensities. During the past couple of decades the LSM has undergone continuous improvement; both usability and technical capa- Figure 1 LSM 880 with Airyscan beam path. For Fast mode imaging, the wheels holding the slit apertures are introduced into the illumination beam path (arrow), shaping the excitation beam into an ellipse. The emission light is captured on the 16 center detector elements (grey) of the Airyscan detector. The remaining 16 detector elements are not used in Fast mode imaging. The Airyscan detector itself remains unchanged and all 32 detector elements are used for Airyscan modes (e.g. superresolution or sensitivity mode). bility of the instruments (to make use of the precious emission light) have been significantly enhanced. These improvements have been the result of constant technical advances, production of high class optical components and improvements in the design of the confocal beam path. But the one ultimate compromise of confocal laser scanning microscopy was not touched until 2014, when ZEISS introduced the Airyscan for its LSM 8 Family systems: the pinhole. 2

Until this point the pinhole would be generally set to a 1 Airy unit (AU) opening diameter; resulting in a good compromise between capturing the scarce emission light and achieving an effective resolution. In theory one can enhance the resolution of a confocal LSM by closing the pinhole below a 1 AU opening. However this is not usually an option, since too much light is rejected resulting in images with unusable signal-to-noise (SNR) ratios. For the first time, the Airyscan detector allowed to combine enhanced resolution and signal to noise for LSM imaging [3]. Airyscan detector The Airyscan detector consists of 32 GaAsP PMT detector elements, which are arranged in a hexagonal array (Figure 1), positioned at a conjugated focal plane in the beam path the detector is functioning as the traditional LSM pinhole. For full flexibility an adjustable optical zoom is present in front of the Airyscan detector which enables adjustment of the number of Airy units that are projected onto the detector. This design made it possible to collect more light (equivalent to a pinhole opened to 1.25 AU), whilst at the same time dramatically enhancing the resolution, with every detector Figure 2 The shape of the laser beam, that enters the back aperture of the objective lens, determines the resulting excitation PSF. Conventionally it is the goal to generate the smallest possible excitation spot with a given objective lens. This is achieved with a laser beam that completely fills the back aperture of the objective lens (left). If the laser beam s diameter is smaller than the back aperture of the objective, the resulting PSF is larger (middle). In order to elongate the excitation PSF only in one direction, an elliptical laser beam is used. This beam is narrowed along one axis, stretching the resulting excitation PSF along that exact axis (right). element acting as an efficient pinhole with a diameter of only 0.2 AU. Instead of facing an either / or decision, a simultaneous enhancement of resolution by the factor of 1.7 x and signal-to-noise by 4 8x was introduced to LSM imaging. Superresolution imaging under gentle conditions, with low laser powers, became part of the confocal LSM repertoire. Flexibility was added with the zoom optic, which allowed researchers to decide if resolution or sensitivity was the priority for the experiment; adapting the Airyscan advantages to the specific experimental needs. Using either multiphoton or single photon excitation without altering the well-established LSM sample preparation and labelling protocols, further broadened the experimental prospects. Detailed descriptions of the theory and technology of Airyscanning can be found in these technology notes [4, 5]. Limitations of acquisition speed in conventional LSM Research objectives can dictate the acquisition of fast, dynamic processes or the quick capture of many fields-ofview (FOV). In both cases, the challenge for the imaging system is to collect sufficient fluorescence for an image with good SNR but in a very limited period of time. Conversely, because traditional LSMs create images one point at a time, image acquisition can be relatively slow. To improve the acquisition speed of LSM instruments, several strategies can be pursued; such as limiting the field of view, sacrificing image resolution (using fewer image pixels) and scanning the laser spot faster. When scanning the laser spot faster across a FOV, the pixel dwell time is shortened. Consequently, the amount of time per pixel spent collecting fluorescence is also shorted which impacts the resulting SNR of the image. As the acquisition speed is increased, fewer and fewer photons will be available resulting in a deterioration of image SNR. The outcome is not only a noisy image but also a compromised spatial resolution, in which fine structures cannot be properly resolved. To compensate for the deteriorating SNR the laser power can be increased but this too has disadvantages; the danger of bleaching the fluorophore and / or damaging live samples by phototoxic effects (e.g. free oxygen radicals) becomes more prevalent at higher laser powers and thus the risk of influencing experimental outcomes is increased [6, 7, 8,]. Therefore, traditional techniques to improve image acquisition speeds demand that a researcher compromises image SNR, resolution, FOV and laser exposure, all of which will likely impede the research goal. 3

Technology Note Fast mode To solve the traditional trade-off between acquisition speed remains unchanged. In LSM 880 the beam shaping is per- and image SNR, the Airyscan detector is used in a new Fast formed by using slit apertures positioned in the excitation acquisition mode. As an area detector the Airyscan can path of the scanhead. Different slit sizes are provided to capture spatial information that is utilized to parallelize the serve a wide variety of objective lenses. These slit apertures scanning process, collecting 4 image lines simultaneously. are therefore arranged on wheels that position the necessary This means enhancing acquisition speed by a factor of 4 slit width into the laser beam path (Figure 1). The excitation while keeping high pixel dwell times to efficiently collect ellipse is scanned along the x-axis of the image field in the emitted photons. Ordinarily, the focused laser beam is conventional manner; but at the end of each line, the laser moved along the x-axis to acquire one image line, before it beam is shifted by the distance of 4 pixels in y direction be- is moved in the y-axis to acquire the consecutive image line. fore scanning the next line. The imaging time for one frame In Fast mode imaging, four image lines are acquired at the is thus reduced 4-fold without reducing the pixel dwell time same time when moving the laser in the x-direction. in the process. In order to excite the fluorescent dye in four lines at a time, The resulting fluorescence for each 4-pixel column is collect- the excitation spot needs to be broadened slightly along the ed by the Airyscan utilizing 16 detector elements of the y-axis. The broadening is achieved by shaping the laser beam Airyscan detector s center (Figure 3) where three horizontal before it enters the objective lens back aperture (Figure 2). detector elements cover 0.9 AU and the up to 6 vertical If the laser beam is narrowed in its y-axis before entering the elements cover 1.65 AU of the emission Airy disk 1. As a result, objective lens, the resulting excitation beam is stretched into each detector element acts as an individual pinhole with a an ellipse along the y-axis, while its size in x direction diameter of about 0.3 AU. Figure 3 Drosophila melanogaster embryo, Jupiter-GFP (microtubules). The left hand image was acquired with the internal GaAsP detectors of LSM 880. The z-stack (80 images) acquisition took 4:47 minutes. The same z-stack was acquired afterwards in Fast mode imaging in only 1:11 minutes. The comparison (close-up; upper image: Fast mode, lower image: internal GaAsP detectors) shows, that as well image quality in Fast mode is superior to the conventional confocal image. Settings for both images: Optimal sampling: 3372 x 1451pixels; Plan-APOCHROMAT 20x / 0.8; Z-stack: 80; Pixel dwell: 0.62 µs Sample courtesy of B. Erdi, Max F. Perutz Laboratories, University of Vienna, Vienna Biocenter, Austria. 1 For image pixel sizes that correspond to at least Nyquist sampling or superresolution sampling; named Optimal and SR sampling in ZEN. 4

The remaining 16 detector elements, of the otherwise unchanged Airyscan detector, are not used and do not produce any digital data. This keeps the data rate lean when streaming it directly onto the hard drive. Each individual detector element of the Airyscan detector is shifted relative to the optical axis by a certain distance. Therefore the captured signal must be reassigned to its point of origin within the resulting image. Consequently emitted photons are not rejected at a pinhole aperture but are rather collected and contribute to the signal of the respective pixel to increase its intensity. This pixel reassignment process, performed on the mathematical basis published by Sheppard et al. [9,10], results in the 4 vertical pixels per laser beam position. The resulting image from the Airyscan in Fast mode shows an enhanced SNR and resolution, because the detector collects more light than with conventional LSM settings, and it combines this with the resolution of a very small pinhole. The concluding deconvolution step therefore profits from both a very small effective PSF and a high SNR. As for conventional point scanning LSM, Fast mode works reliably in thicker samples; and can be used with multiphoton excitation to analyze highly scattering tissue. Using Airyscan in Fast mode enables the use of this unique GaAsP area detector for spatial parallelization to enhance imaging speed without compromising pixel dwell time. Airyscan in Fast mode delivers images with 4 times more SNR at a 4 times increase in acquisition speed. At the same time the characteristic advantages of the Airyscan are preserved and allow for increased resolution by a factor of 1.5 x. Furthermore, these advantages can be realized without making any changes to sample preparation or staining protocols and can be seamlessly integrated into current experimental workflows. The result of simultaneously improving resolution, SNR and speed on an optical sectioning system provides researchers with the unique combination of gentle imaging with high spatial and temporal resolution. This unprecedented combination of functionality promises to meet the growing demand for efficient large volume imaging whilst also addressing large scale structural studies and providing the capability of capturing dynamic processes for functional analysis. With Fast mode for Airyscan, ZEISS expands the potential of the Confocal Laser Scanning Microscope. Conclusion The introduction of Airyscan eliminated the requirement to choose between high resolution and high sensitivity; both could be achieved at once. In the same way, Airyscan Fast mode now takes this one step further by enabling simultaneous improvements in resolution, sensitivity and speed. Fast mode characteristics Fast mode Airyscan detector in Fast mode AU per element LSM 880 with Airyscan acquisition mode to acquire 4 image lines simultaneously, increasing image acquisition by 4-fold 16 central detector elements of the Airyscan detector are active. The remaining 16 detector elements are not used for Fast mode acquisition. ~ 0.3 AU Resolution Enhanced by 1.5 fold x = 145 nm, y = 180 nm, z = 450 nm Sensitivity 4 x enhanced SNR at 4 times faster image acquisition Speed 512 x 512 pixel 19 fps 480 x 480 pixel 27.3 fps 480 x 128 pixel 86.1 fps 1024 x 1024 pixel 6.2 fps 2048 x 2048 pixel 1.6 fps 5

Glossary Airy disk Airy pattern Airy Unit (AU) GaAsP LSM Pinhole Pixel dwell PMT PSF SNR The center spot of the Airy pattern. A single point source is imaged by a microscope as a blurred spot with surrounding rings of decreasing intensities, due to the diffraction nature of light. Diameter of the Airy disk, measured from the first surrounding intensity minimum. Gallium arsenide phosphide. Semiconductor material, which is used as a coating for the photocathode of the detector. The photocathode converts photons into electrons. Laser scanning microscope Aperture, positioned in the conjugated focal plane in the emission beam path, blocking out-of-focus light. Duration the laser is illumination one position and the microscope system is collecting emission light, to generate one image pixel Photomultiplier tube; common basis for light detectors in Laser Scanning Microscopes Point spread function. Describes the pattern that is generated by a microscope of a point emitting light source. Signal to noise ratio. References: [1] Conchello, J. A. and Lichtman, J. W., Optical sectioning microscopy. Nature methods, 2005. 2(12): p. 920 931. [2] Minsky, M., Memoir on inventing the confocal scanning microscope. Scanning, 1988. 10(4): p. 128 138. [3] Huff, J., The Airyscan detector from ZEISS: confocal imaging with improved signal-to-noise ratio and super-resolution. Nature methods, 2015. 12. [4] Weisshart, K., The basic principle of Airyscanning. 2014. ZEISS Technology Note [5] Huff, J.; Bathe, W.; Netz, R.; Anhut, T.; Weisshart, K., The Airyscan detector from ZEISS. Confocal imaging with improved signal-to-noise ratio and superresolution. 2015. ZEISS Technology Note [6] Wäldchen, S. et al., Light-induced cell damage in live-cell super-resolution microscopy. Sci.Rep, 2015. 5: p. 15348 [7] Li, D. et al., Extended-resolution structured illumination imaging of endocytic and cytoskeletal dynamics. Science, 2015. 349 (6251) [8] Kucsko, G. et al., Nanometre-scale thermometry in a living cell. Nature 2013. 500: p. 54 58. [9] Sheppard, C.J., Super-resolution in confocal imaging. Optik, 1988. 80 (2): p. 53 54. [10] Sheppard, C.J.; Mehta, S.B., and Heintzmann, R., Superresolution by image scanning microscopy using pixel reassignment. Opt Lett 2013. 38(15): p. 2889 2892. Title: Right side: Single images of a time series. Drosophila embryo, maximum intensity projection. Microtubules labeled with GFP. Z-stack with 72 slices imaged for 11.5 h at 15 min interval. Courtesy of B. Erdi, Max F. Perutz Laboratories, University of Vienna, Austria Left side: Single images of a time series. Calcium sparks labeled with Fluo 4 imaged in Cardiomyocytes with 50 frames per second. Courtesy of P. Robison, B. Prosser, University of Pennsylvania, USA 6

Not for therapeutic, treatment or medical diagnostic evidence. Not all products are available in every country. Contact your local ZEISS representative for more information. EN_41_013_125 CZ 04-2016 Design, scope of delivery and technical progress subject to change without notice. Carl Zeiss Microscopy GmbH Carl Zeiss Microscopy GmbH 07745 Jena, Germany microscopy@zeiss.com www.zeiss.com/lsm880