Magneto Optic Current Transformer Technology (MOCT)

Similar documents
Light measures current

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

Transcutaneous Energy Transmission Based Wireless Energy Transfer to Implantable Biomedical Devices

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

1. Introduction to Power Quality

Non-conventional instrument transformers and power quality aspects an overview

Dynamic Modeling of Flyback Switching Power Supplies Using Graph Modeling: Case Study in Variable Speed DC Drives

Performance Assessment of Advanced Digital Measurement and Protection Systems

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers

ELECTRICAL ENGINEERING ESE TOPIC WISE OBJECTIVE SOLVED PAPER-II

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

Measurement and Analysis for Switchmode Power Design

Enhancement of Fault Current and Overvoltage by Active Type superconducting fault current limiter (SFCL) in Renewable Distributed Generation (DG)

Generator Advanced Concepts

ABB FOCS Fiber-Optic Current Sensors. Make light work of dc current measurement

Glossary of Common Magnetic Terms

Solid state electric field sensor

Capacitive Voltage Substations Ferroresonance Prevention Using Power Electronic Devices

In this lecture. Electromagnetism. Electromagnetism. Oersted s Experiment. Electricity & magnetism are different aspects of the same basic phenomenon:

Back to the Basics Current Transformer (CT) Testing

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

UNIT II MEASUREMENT OF POWER & ENERGY

Design of Differential Protection Scheme Using Rogowski Coil

Faraday Laws of Electromagnetic Induction CLIL LESSON

Inductance Based Sensorless Control of Switched Reluctance Motor

Closed Loop Control of the Three Switch Serial Input Interleaved Forward Converter Fed Dc Drive

Substation Testing and Commissioning: Power Transformer Through Fault Test

Innovative Science and Technology Publications

STUDY AND DESIGN ASPECTS OF INDUCTORS FOR DC-DC CONVERTER

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION

Accurate Current Measurement Transducer for Relaying Purpose

Reducing the Fault Current and Overvoltage in a Distribution System with an Active Type SFCL Employed PV System

EE2022 Electrical Energy Systems

Lecture 36 Measurements of High Voltages (cont) (Refer Slide Time: 00:14)

DESIGNING AND MANUFACTURING CURRENT TRANSMITTER ON MV SYSTEMS FOR SMART GRID APPLICATIONS

How to Select the Right Current Probe APPLICATION NOTE

A Novel Control Strategy of Shunt Active Filters

REQUIRED SKILLS AND KNOWLEDGE UEENEEG101A. Electromagnetic devices and circuits. Topic and Description NIDA Lesson CARD # Magnetism encompassing:

The Fault Level Reduction in Distribution System Using an Active Type SFCL

Electrical Machines I : Transformers

LFR: flexible, clip-around current probe for use in power measurements

CHAPTER 5 CONCEPTS OF ALTERNATING CURRENT

BUS2000 Busbar Differential Protection System

Ferroresonance Experience in UK: Simulations and Measurements

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

Digital Simulation of Thyristor Controlled Interphase Power Control Technology (TC- IPC) to limit the fault currents

Basics of electrical transformer

DESIGN AND CONSTRUCTION OF 1500VA VARIABLE OUTPUT STEP DOWN TRANSFORMER

MATHEMATICAL MODELING OF POWER TRANSFORMERS

Sensitivity Analysis for 14 Bus Systems in a Distribution Network With Distributed Generators

Electrical Theory 2 Lessons for Fall Semester:

Analysis of Voltage Source Inverters using Space Vector PWM for Induction Motor Drive

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

(2) New Standard IEEE P (3) Core : (4) Windings :

A Study on Ferroresonance Mitigation Techniques for Power Transformer

Exercise 10. Transformers EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Introduction to transformers

Inductance in DC Circuits

Alternative Testing Techniques for Current Transformers. Dinesh Chhajer, PE Technical Support Group MEGGER

Dual Feed Microstrip Patch Antenna for Wlan Applications

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

CHAPTER 3 SHORT CIRCUIT WITHSTAND CAPABILITY OF POWER TRANSFORMERS

PHYSICAL PHENOMENA EXISTING IN THE TURBOGENERATOR DURING FAULTY SYNCHRONIZATION WITH INVERSE PHASE SEQUENCE*

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

(51) Int Cl.: G01R 15/06 ( ) (54) Combined current and voltage measurement transformer of the capacitor bushing type

Investigations of Fuzzy Logic Controller for Sensorless Switched Reluctance Motor Drive

Accurate Modeling of Core-Type Distribution Transformers for Electromagnetic Transient Studies

Transformers. gpmacademics.weebly.com

TECHNICAL BULLETIN 004a Ferroresonance

Using Optical Isolation Amplifiers in Power Inverters for Voltage, Current and Temperature Sensing

Busbars and lines are important elements

Electromagnetic energy harvester for atmospheric sensors on overhead power distribution lines

SATURATION ANALYSIS ON CURRENT TRANSFORMER

5. Transducers Definition and General Concept of Transducer Classification of Transducers

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

6545(Print), ISSN (Online) Volume 4, Issue 3, May - June (2013), IAEME & TECHNOLOGY (IJEET)

A3-102 PCB ROGOWSKI COILS HIGH PRECISION LOW POWER SENSORS. Ljubomir A. Kojovic * Cooper Power Systems USA

Inductive Sensors. Fig. 1: Geophone

Power Quality Analysis in Power System with Non Linear Load

GLOSSARY OF TERMS FLUX DENSITY:

DETECTING SHORTED TURNS

Bus protection with a differential relay. When there is no fault, the algebraic sum of circuit currents is zero

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Maintaining Voltage-Current Phase Relationships in Power Quality Monitoring Systems

SPH3U UNIVERSITY PHYSICS

Preface...x Chapter 1 Electrical Fundamentals

Importance of Transformer Demagnetization

Resonant Inverter. Fig. 1. Different architecture of pv inverters.

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Transformer Waveforms

PANIMALAR ENGINEERING COLLEGE Department of Electrical and Electronics Engineering

ISSN: [IDSTM-18] Impact Factor: 5.164

Design of A Closed Loop Speed Control For BLDC Motor

Electromagnetic Induction - A

Power systems 2: Transformation

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

Iron Powder Core Selection For RF Power Applications. Jim Cox Micrometals, Inc. Anaheim, CA

Magnetics Design. Specification, Performance and Economics

Beyond the Knee Point: A Practical Guide to CT Saturation

Investigation of Inter-turn Fault in Transformer Winding under Impulse Excitation

Transcription:

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 12, Issue 1 Ver. IV (Jan. Feb. 2017), PP 46-50 www.iosrjournals.org Magneto Optic Current Transformer Technology (MOCT) Attish Jain Btech, Eee, Srm University Kancheepuram Kattankulathur -603203 Abstract: An accurate electric current transducer is a key component of any power system instrumentation. To measure currents power stations and substations conventionally employ inductive type current transformers.for high voltage applications, porcelain insulators and oil-impregnated materials have to be used to produce insulation between the primary bus and the secondary windings. The insulation structure has to be designed carefully to avoid electric field stresses, which could eventually cause insulation breakdown. The electric current path of the primary bus has to be designed properly to minimize the mechanical forces on the primary conductors for through faults. The reliability of conventional high-voltage current transformers have been questioned because of their violent destructive failures which caused fires and impact damage to adjacent apparatus in the switchyards, electric damage to relays, and power service disruptions. In addition to the concerns, with the computer control techniques and digital protection devices being introduced into power systems, the conventional current transformers have caused further difficulties, as they introduce electromagnetic interference through the ground loop into the digital systems. Magneto-optical current transformer(moct)technology provides a solution for many of the above mentioned problems. The MOCT measures the electric current by means of Faraday Effect that is the orientation of polarized light rotates under the influence of the magnetic fields and the rotation angle is proportional to the strength of the magnetic field component in the direction of optical path. MOCT is a passive optical current transducer which uses light to accurately measure current on high voltage systems and determines the rotation angle & converts it into a signal of few volts proportional to the current. Keywords: electric current transducer, Faraday effect, power system, switchyards, current transformers I. Introduction MOCT-Principle The Magneto-Optical current transformer is based on the Faradays effect. Michael Faraday discovered that the orientation of linearly polarized light was rotated under the influence of the magnetic field when the light propagated in a piece of glass, and the rotation angle was proportional to the intensity of the magnetic field. Generally, this phenomenon can be described as follows: = V dl Eq (1) is the Faraday rotation angle, 'V is the constant for magneto-optical material B is the magnetic flux density along the optical path l is the optical path When the linearly polarized light encircles a current carrying conductor eq(1) can be rewritten as according to Ampere s law as =n VI.Eq(2) I is the current to be measured, is the permeability of the material, n is the number of turns of the optical path. The Faraday effect outlined in eq(2) is a better format to apply to an MOCT, because the rotation angle in this case is directly related to the enclosed electric current. It rejects the magnetic field signals due to external currents which are normally quite strong in power system. A polarizer is used to convert the randomly polarized incident light into linearly polarized light. The orientation of the linearly polarized light rotates an angle after the light has passed through the magnetooptical material because of Faraday Effect. Then another polarization prism is used as an analyzer, which is 45 oriented with the polarizer, to convert the orientation variation of the polarized light into intensity variation of the light with two outputs, and then these two outputs are send to photo detectors. The purpose of using the DOI: 10.9790/1676-1201044650 www.iosrjournals.org 46 Page

analyzer is that photo detectors can only detect the intensity of light, rather than the orientation of polarizations. The output optical signals from the analyzer can be described as, P1 = (1 + Sin 2 ) P2 = (1 - Sin 2 ) is the Faraday rotation angle, P1 and P2 are the optical power delivered by the detectors. In order to properly apply Eq(2) in the MOCT design by making the optical path wrap around the current carrying conductor, the optical path has to be folded by reflections. Total internal reflections and metal reflections are good ways to achieve this. However reflections introduce phase shift; hence change the polarization state of the light. The optical prism has to be designed to keep the light going through the MOCT linearly polarized. II. System Analysis of MOCT The configuration of the test system is shown in block diagram form in the Figure below. The equipment configuration is a current source, adjustable from zero to 4000 amperes, whose output is passed through a precision CT and the MOCT rotator. The output of these two sensors are measured by an instrument package which computes the ratio of the MOCT output with respect to the ct output. This method permits comparison of ratio stability of the MOCT against a known standard. In addition, the ct output is applied to a watt-hour standard while the MOCT output operates the current section of an electronic meter. Application of the current to both the meter under test and the reference standard along with parallel application of a voltage source provides an accurate method of comparing the two systems in a ratio metric manner. Temperature Characteristics The first test was to characterize the rotator output with variation in temperature. The rotator and interface electronics were placed in an environmental chamber that allowed temperature profiles to be run on the system while it was operating, and the effect of temperature measured. Two temperature effects were studied. First, the change in the MOCT output that could be related to shifts in the steady state operation due to temperature excursions possible in field conditions. This sets the extremes of the temperature range. Second, it was known that temperature induced stress on the optical system could result in short term changes in the output levels: therefore, a study of the effect of rate of change in temperature was important to characterize the system. DOI: 10.9790/1676-1201044650 www.iosrjournals.org 47 Page

A typical temperature profile for a test run is obtained. This is considered to be an extreme worst case test condition as it stresses the MOCT system by changing the temperature in a 24 hour period, approximately 10 degrees per hour. Examination of the temperature profiles taken during the field test show this to be a good assumption for the Tennessee area. Following is the variation in ratio performance of the MOCT system under the above test condition. Under this extreme test, the device will exhibit no more than 0.1% error from -3O C (- 220F) to +60 C (+1400F) when compared to the reference CT operating at room temperature. These test were run for each of the precision current transformer ranges with similar results for all ranges. Each test in each range was repeated several time with only slight variations in results from test to test. Temperature conditions applied for testing Time in mins. Air Temp C 0 20 10-30 20-30 30-30 40-20 50-10 60 0 70 20 80 40 90 60 100 70 120 80 130 95 140 96 150 95 Testing data gathered Simulation done on Matlab for temperature vs. time data DOI: 10.9790/1676-1201044650 www.iosrjournals.org 48 Page

MOCT and conventional ct comparison Stability Ratio Temperature in c MOCT stability ratio Conventional ct ratio -20 1 1-10 1 1 0 1 1 10 1 1 20 0.999 0.999 30 0.999 0.998 40 0.997 0.995 50 0.998 0.995 60 0.996 0.996 70 0.997 0.994 Temperature vs stability ratio factor for a MOCT system and conventional ct system Matlab simulation for Temperature vs stability ratio factor for a MOCT system and conventional ct system Matlab code for simulation of temperature and stability coefficient ratio DOI: 10.9790/1676-1201044650 www.iosrjournals.org 49 Page

Advantages of a MOCT system over a conventional ct system: 1. Resistance to Acoustic and Electromagnetic interferences is excellent which plays an important role in protecting the equipment 2. In terms of size and weight, they have small size and low weight ratio. The probable installation and relocation does not require heavy machinery which makes it economical 3. They have high electrical insulation resistance. 4. Lack of magnetic saturation. Due to Lack of core, there is no saturation which solves many protection and Measurement problems 5. Lack of Ferro resonance phenomena and hysteresis. 6. The measurement error is less, than 0.3%. 7. The power supply is not used in the HV section. 8. Self-supervision is possible. 9. They can withstand high mechanical load. 10. Complete isolation in high voltage section and control room. 11. They are compatible with computer systems and can provide output in digital format. 12. They provide protection against short circuits and output breaks 13. PCB that are severe environmental pollutants are not used. 14. The measurement and analysis of current with higher harmonics is possible. III. Conclusion The results have confirmed that the MOCTs are suitable for power system protection and can replace the current magnetic CTs used in the industries as the variation of stability coefficient/factor analysed is always close to 1 for various test temperature scale applied on the MOCT apparatus. As can be seen the MOCT system compares favourably with the conventional system. In terms of comparison of performance against objectives for the project, the MOCT demonstrate the following applications/advantages over conventional current transformer: Optical sensors can be designed to perform reliably in operating system environments Stable and accurate performance in the substation environment is obtainable with proper design Effects of temperature, humidity, vibration, and electromagnetic interference are negligible or nonexistent when the system is compared to a high accuracy conventional system In future the MOCT technology can be used for advanced tariff measurement and protective relays. Values of RMS of Output current in conventional CTs and MOCT are measured by less than 0.1% difference from each other which relates to the high quality of the MOCT output signal MOCT can determine the future output of the signal and hence can replicate the given signal if a given portion of a signal is lost thereby giving a continuous and uninterrupted signal at the output end. Rapid advances in the quality of performance and costs of the optical fibre and electronic equipment encourage development of measuring trances based on new technology. There is a high scope of application in the field of transmission and distribution for MOCT technology which would result in safer and more cost efficient systems. References [1]. IEEE Transactions on Power Delivery, Vol. 5, No. 2, April 1990, Paul Johnston [2]. Westinghouse Electric Corporation Raleigh, North Carolina [3]. S. Saito, J. Hamasaki, Y. Fujii, K. Yokoyama, and Y. Ohno, "Development of the laser current transformer for extra high- voltage power transmission lines', IEEE J. Quant. Elec., vol QE-3, pp. 569-597, Nov. 1967. [4]. A.J. Rogers, "Method for the simultaneous measurement of current and voltage on high-voltage lines using optical techniques," Proc. leee, Vol. 123, pp. 957-960, Oct. 1976. [5]. S.C. Rashleigh and R. Ulrich, "Magneto-optic current sensing with bi fringing fibres', Appl. Phys. Lett., vol. 34, pp. 766-770, June 1979. [6]. D.C. Erickson, "The use of fibre optics for communications, measurement, and control within high voltage substations,' IEEE Trans. on Pwr. Appr. and Syst., vol. PAS-99, pp. 1057-1065, May/June 1980. [7]. R.H. Stolen and E.H. Turner, "Faraday rotation in highly birefringent fibers", Appl. Opt., vol. 19, pp. 842-845. 15 March 1960. [8]. G.w. Day, D.N. Payne, A.J. Barlow, and J.J. Ramskov Hanson, "Faraday rotation in coiled, monomode optical fibers: Isolators, filters, and magnetic sensors', Opt. Lett., vol. 7, pp. 238-240, May 1982. [9]. M. Kanoi, G. Takahashi, T. Sato, M. Higaki, E. Mori, and K. Okumura, 'Optical voltage and current measuring system for electric power systems', IEEE Trans. on Pwr. Del., vol. PVVRD-1, pp. 91-97, Jan. 1986. [10]. P.R. Forman and F.C. Jahoda, "Linear birefringence effects on fiber optic current sensors", App. Opt., vol. 27, pp. DOI: 10.9790/1676-1201044650 www.iosrjournals.org 50 Page