ULTRA-K Series 600K - he

Similar documents
60K(i) - 260K(i) THREE PHASE. SureImage IMAGING & TREATMENT SERIES

Power Processor - Series 700F 10KVA to 150KVA

Power-Sure 700. Technical Data TD158001EN. Contents

Power Commander. Power Commander Plus. Electronic Line Voltage Regulators. 15 kva 150 kva SINGLE PHASE 15 kva 450 kva THREE PHASE SERIES 900

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

Power Conditioners product guide

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

K Factor Power Transformers

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

AC/DC Current Oscilloscope Probe Model SL261

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Low Pass Harmonic Filters

Phoenix DX Clean Power (18 Pulse) AC Drive

TOSHIBA International Corp

Liebert Datawave. GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL

Isolation Transformer Series

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

PRODUCT FEATURES TYPICAL APPLICATIONS

General Description & Features Selection Charts Definition of Terms... 42

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated

Harmonic mitigating transformers. Energy savings through harmonic mitigation

Alternator winding pitch and power system design

Electromagnetic Harmonic Filters Technical Guide

Load Isolation Transformers

T S 15KVA 1PH 240/480 Transformer

EcoSystem 5-Series LED Driver 15 W to 75 W

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

What is a Transformer?

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

POWER QUALITY PRODUCTS FOR NON-LINEAR LOADS

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

C.P. SENTINEL AQUA-LINE

Harmonic mitigating transformers. Energy savings through harmonic mitigation

High Frequency Sinewave Guardian TM Filter

B9000 FXS kVA B9600 FXS kVA

Presents. Harmonics Years

Power Protection and Conditioning

Est Triplen Power Distribution Unit TPDU kVA

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

Table of Contents. Facility EMI Filter Products

ISOLATING TRANSFORMERS FOR TLC PLANTS

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

ASX SERIES PACIFIC OPERATION MANUAL AC POWER SOURCE POWER SOURCE

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

Energy Efficient Distribution Transformers

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

StatiVolt. Inverter UPS Systems. Features. Contents

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

High Frequency SineWave Guardian TM Filter

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

USER S MANUAL. 1KSS60400/ ST Edition

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Straight Isolation - Plug In (171 Series)

3Ø Short-Circuit Calculations

CB Scheme UL508 UL ATEX II3G

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Short Circuit Current Calculations

Strategies for design 600V large modular UPS for critical power applications

Dry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION

Warehouse Stock Transformers

EMI Installation Guidelines

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Output Voltage* (nom.)(adjustable)

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

MODEL 421 Over/Under Motor Load Monitor

Design Specifications Low Voltage Active Harmonic Filter

Active Harmonic Filter

1 INTRODUCTION ORDER CODE / INFORMATION

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

Transcription:

5 kva 500 kva ULTRA-K Series 600K - he High Efficiency K-Rated Power Conditioning Transformers Designed to be used with linear or non-linear loads. Applications: Audio / Video Recording Equipment IT Systems / Computers VFD Controls Automated Scanning Electronics Isolation for Uninterruptible Power Systems Laboratory Instrumentation Electronic Measurement Key Facilities / Industries: Schools Recording Studios Performing Arts / Theaters Waste Water Treatment Pharmaceutical Automated Manufacturing Meets and Exceeds DOE 2016 Minimum Efficiency Standard UL 1561 C-UL Listed to CSA Standard C22.2, No. 47-13 Single and Three Phase Models Available (300 kva and 500 kva models not shown)

POWER PROBLEMS & SOLUTIONS Controlled Power Company engineers and manufactures the industry s highest quality power conditioning transformers, capitalizing on over 45 years of expertise. This enviable reputation for quality is reflected in the design, workmanship, and performance of our products. Subjecting commercial and industrial electrical systems to a harsh, polluted electrical environment increases downtime, maintenance costs, and lost productivity. Maintaining spike-free voltage and keeping electrical noise away from the sensitive electronics, increases the reliability of electronic equipment, contributes to the overall integrity of data, and enhances workflow and productivity. Controlled Power Company s ULTRA-K Series 600K-he High Efficiency, K-Rated, Power Conditioning Transformers are specifically designed to provide a high degree of electrical noise attenuation and optional transient voltage suppression to sensitive electronic loads. In addition, the ULTRA-K is offered with four different K-factor ratings (K4, K7, K13, K20) for full compatibility with harmonic-rich, non-linear loads. The ULTRA-K Series 600K-he meets and exceeds the high efficiency levels defined by the U.S. Department of Energy (DOE) 2016 Standard, thus providing true energy savings under both linear and non-linear loads. Electrical Noise & Voltage Transients Electrical noise is a high frequency, low energy signal that travels on the power and ground lines of an electrical distribution system. While conditions external to a facility can cause electrical noise and impulses, the majority of these disturbances are generated by electronic and electrical equipment within the facility. Examples of this equipment include photocopiers, lighting controls, variable speed drives, and motor loads. The electrical noise produced by this equipment can harm digital circuitry, because the high frequencies can easily be coupled into the signal path and cause data corruption. This corruption often results in system upset, unexpected restarts, and nuisance equipment behavior. In addition to electrical noise and impulses, high energy transients may also exist which lead to component failure within critical electronics and controls. Electrical noise and voltage transients illustrated. Isolation 3 Shields SPD with High Frequency Filter Isolation 3 Shields Isolation 2 Shields Building the ULTRA-K solution to power problems. ULTRA-K Series 600K-he Solution The ULTRA-K is provided standard with 2 full-length electrostatic shields which provide 126dB common mode noise attenuation. An optional 3rd shield is available which increases the attenuation to 146dB. That is 20dB greater in decibels, but the noise attenuation is actually 10 times greater! The ULTRA-K not only attenuates noise from input to output... but also prohibits system back feed from noise generating loads. In addition, an optional pre-wired, high frequency filter and category B3 surge protection device (SPD) provide your critical loads with optimum protection from noise and impulses, as well as high energy voltage transients. The ULTRA-K s noise attenuation is critical for any application in which digital circuitry is used to scan, measure or monitor critical data, control a critical process, or reproduce high quality audio / video signals! 2 Copyright June 2017. Controlled Power Company.

ULTRA-K DESIGN BENEFITS As an owner or specifying engineer... why choose the ULTRA-K Series 600K-he over competing brands? It s a fair question. We believe that the answer is found in (3) key objectives which needed to be met when we designed this product. Design the very best power conditioning isolation transformer to protect critical loads against electrical noise, impulses, and voltage transients. As described on Page 2 of this brochure... mission accomplished! Design the ULTRA-K with the ability to handle the high harmonic currents associated with non-linear loads. To accomplish this, each ULTRA-K is made available with a K-factor rating of K4, K7, K13, or K20. The higher the K-rating, the more harmonic current the transformer can handle. In addition, the ULTRA-K removes load-generated triplen harmonics from the incoming power source! Design the ULTRA-K not only to meet, but exceed high efficiency levels defined by the U.S. Department of Energy (DOE) 2016 Standard. As illustrated below... slam dunk! When selecting the ULTRA-K Series 600K-he... you re simply choosing the very best High Efficiency, K-rated Power Conditioning Transformer available. Harmonics & K-Factor Ratings Commercial and industrial facilities contain a myriad of electronic and electrical equipment that represent non-linear loads. Examples include non-pfc power supplies found in computers and lighting, as well as high-powered electronic controls. Linear loads draw current throughout the entire 60Hz waveform, tracking the applied voltage. Non-linear loads draw current in short intervals with extraordinarily high magnitudes (see illustration to the right), generating harmonics (multiples of the fundamental 60Hz). These harmonics create additional heat within the transformer windings, and may increase the output neutral current up to 200% on 3 phase models with line-to-neutral loading. To overcome this safety problem, an ULTRA-K transformer is designed specifically to handle the harmonics, heating effects, and increased output neutral current created by non-linear loads. Its K4 through K20 selections allow it to be properly applied for both linear and non-linear loads! Ultra-K Series 600K-he Efficiency Examples NOTE: The chart above illustrates the efficiency measured on (3) sample transformers. The green dots are positioned to reflect the DOE minimum efficiencies in comparison to the ULTRA-K efficiencies measured. DOE 2016 minimum efficiency levels at 35% of nameplate-rated load with a transformer operating temperature of 75 C: 45kVA (98.40%); 75kVA (98.60%); 150kVA (98.83%). Voltage and Current Waveforms: Output Voltage Linear Load Current Non-linear Load Current ULTRA-K High Efficiency Advantage The ULTRA-K is uniquely designed to provide efficiencies that meet and exceed the DOE 2016 Standard. Energy savings are easily seen when comparing the power losses of the ULTRA-K to a transformer only meeting the DOE minimum efficiency. For example, our 150 kva ULTRA-K tested 99% efficient at 35% load; that s only 530 W of losses, compared to the minimum required efficiency of 98.83% which represents 621 W of losses. The ULTRA-K power losses were 17% lower, which reflect a decrease in operating costs over the life of the transformer. Efficiency for a given KVA size will vary from transformer to transformer, but the ULTRA-K s design allows its efficiency to still exceed the minimum DOE-mandated level. 3

SPECIFICATIONS Power Output Single Phase Three Phase Operating Frequency 5, 8, 10, 15, 20, 25 kva 15, 30, 45, 75, 112.5, 150, 225, 300, 500 kva Frequency 60Hz +/- 5% Note: 50Hz models available, consult factory Electrical Input Single Phase (5-25kVA) Voltage Taps 208, 240, 480, or 600 VAC (2) 2.5% Full Capacity Above Nominal (4) 2.5% Full Capacity Below Nominal Three Phase (15-150kVA) 208, 240, 480, or 600 VAC (Delta) (225-500kVA) 480, 600 VAC (Delta) Voltage Taps (15-300kVA*) (2) 2.5% Full Capacity Above Nominal (4) 2.5% Full Capacity Below Nominal * Exception (112.5kVA - 150kVA at (1) 5% Full Capacity Above Nominal 208 VAC or 240 VAC) (2) 5% Full Capacity Below Nominal (500kVA) (1) 3.5% Full Capacity Above Nominal (2) 3.5% Full Capacity Below Nominal Note: Special voltages available for both single and three phase models. (see Page 6 Model Number Guide, Note¹) Electrical Output Single Phase Three Phase Output Impedance Output Distortion Load Regulation 120, 120/240, or 208 VAC 208/120 or 480/277 VAC (Wye) Note: Special voltages available (see Page 6 Model Number Guide, Note¹) 2% to 3.5% typical Less than 1.0% THD added under linear load 2% typical, no load to full load Overload Up to 500% for 10 seconds, 1000% for 1 cycle Isolated Neutral Establishes a new neutral to ground bond on the transformer s output (see Page 5 Isolated Output Neutral section) Noise Attenuation Common Mode Transverse Mode Environmental Operating Ambient Temperature Relative Humidity Altitude Audible Noise 126dB - Standard double (2) shield 146dB - Optional triple (3) shield 3dB down at 10kHz, decaying 20 db per decade; decaying 40 db with SPD With High Frequency option -25 C to +40 C 0 to 95% non-condensing Up to 5000 feet above sea level without de-rating 45 to 55dBA @ 1 meter, depending on kva size Efficiency U.S. Canada K-factor Ratings Ratings Neutral Size Meets and exceeds U.S. Department of Energy (DOE) 2016 high efficiency standards identified under DOE 10 CFR Part 431 Meets and exceeds CSA Standard C802.2-12 K4, K7, K13, K20 Twice the ampacity of the secondary phase conductor on three phase models Harmonic Handling Capability Designed to handle the following percentages of fundamental and harmonic currents, without exceeding temperature rise limits. K4 K7 K13 K20 Fundamental 60 Hertz 100% 100% 100% 100% 3rd Harmonic 25% 35% 40% 45% 5th Harmonic 20% 30% 42% 48% 7th Harmonic 12% 18% 25% 38% 9th Harmonic 3% 5% 7% 9% 11th Harmonic 5% 6% 10% 12% 13th Harmonic 4% 4% 8% 10% 15th Harmonic 2% 2% 3% 3% 17th Harmonic 1% 1% 2% 2% Harmonic Elimination The load generated triplen harmonics of the fundamental (3rd, 9th, 15th, 21st, etc.) are eliminated from the input lines, thus reducing the overall THD content. General Transformer All copper winding and conductor construction, Construction dry type transformer with M3, grain-oriented silicon steel Electrical Copper bus provided for hardwired input and output Connection Note: Optional lug kits available (see Page 5) Basic Impulse Level 10KV Temperature Rise 135 C rise above ambient, under non-linear loading per UL 1561 standard Cooling Convection cooled Enclosure Standard, floor mounted: NEMA 2 up to 225kVA; NEMA 1 at 300kVA and 500kVA Note: Optional NEMA 3R outdoor enclosure available up to 225kVA (see Page 5) Certifications Safety RoHS h NOTE: The chart above represents only one scenario (per K-factor rating) of an infinite combination of harmonic content that could add up to a specific K-factor. Consult factory with your harmonic load profile for assistance in K-factor selection. UL 1561 Listed, labeled for operation with or below a specific K-factor rating; C-UL listed to CSA Standard C22.2, No. 47-13 Compliant Please visit our website and read our General and Guide Specifications for additional technical details about the ULTRA-K Series 600K-he. 4

SPECIFICATIONS & OPTIONS Isolated Output Neutral The ULTRA-K establishes a new neutral to ground bond on the transformer s output, meeting the definition of a separately derived power source as defined in NFPA 70, Article 250.20 (D). Its isolated wye secondary provides a new single point ground reference to which critical load neutral and ground conductors are wired, thus preventing potential N-G circulating currents. Application Note: The ULTRA-K may be paired with a transformer-less uninterruptible power system (UPS). This is critical if the input neutral to the UPS is shared with other electrical noise-producing loads, creating noise voltage with respect to ground. The transformer provides an isolated, clean neutral bond for IT/data center equipment. Locating the transformer at the input or output of the UPS is dictated by the UPS configuration and grounding requirements. In either case, the ULTRA-K ensures that the critical load is provided with the highest power quality, even when the UPS is in bypass mode. Options Output SPD With High Frequency Filter Surge Protection Device (SPD) network comprised of high energy MOVs with <5 nanosecond response time and a maximum peak surge current capacity of 40 ka (8/20 μs) per mode. High frequency filter increases transverse mode noise attenuation to 3 db down at 10kHz, decaying 40 db per decade. A single status indicator light (pictured on NEMA 2 enclosure shown) is provided to show that the SPD and filter are fully operational and functioning properly. NOTE: SPD with peak surge current capacity ratings from 50 ka to 200 ka per phase are available, UL 1449 Listed, Type 2. Includes EMI/RFI filtering, Form C relay contacts, and LED protection status indicators. Contact factory for specifications. (See NOTE below) Input / Output Circuit Breaker Circuit breaker (15A 800A ratings) provided in a separate NEMA 1 enclosure for external mounting and installation. High / Over Temperature Alarm Contacts Thermal warning alarm contacts for customer s hardwired connection. Thermal sensors at 180 C and 200 C. (See NOTE below) Model shown with standard NEMA 2 enclosure, and optional SPD status indicator light. (30 kva model shown) NEMA 3R Enclosure UL Listed NEMA 3R enclosure for outdoor installations. Enclosure is constructed using 14 gauge galvanized steel and provided with a durable powder coat paint finish. (See NOTE below) IR Scanning Window Infrared, transparent polymer IR window(s) for safe routine thermal scanning of transformer connections under load, without exposing personnel to arc flash hazards. Durable IR windows are industrial-grade with a patented reinforced grill, fully impact-resistant, and UL and C-UL Listed. This option adds 2 to the depth of the 112.5 kva 225 kva enclosure. (See NOTE below) Lug Kit Mechanical (screw-type) lugs shipped for installer convenience. Consult factory for number of conductors per lug and wire range. Special Designs Special voltage configurations are available, including high leg delta designs. NOTE: Option not available for 300kVA and 500kVA models. Model shown with optional NEMA 3R enclosure, and optional IR scanning window. (75 kva model shown) 5

MODEL NUMBER & SELECTION GUIDE MODEL NUMBER GUIDE - ULTRA-K SERIES 600K-he PHASE INPUT OUTPUT FREQ 2 kva K-RATING # OF OUTPUT ENCLOSURE VOLTAGE 1 VOLTAGE 1 SHIELDS VOLTAGE SPD 3 TYPE 4 5 = Single B = 208 A = 120 X = 60Hz 5K6HE 45K6HE 4 A = 2 A = SPD with 1 = NEMA 1 8 = Three C = 240 B = 208 8K6HE 75K6HE 7 B = 3 High Frequency Filter 2 = NEMA 2 D = 480 G = 120/240 10K6HE 112.5K6HE 13 B = SPD with Filtering; 3R = NEMA 3R E = 600 L = 208/120 15K6HE 150K6HE 20 UL 1449 Listed, Type 2 N = 480/277 20K6HE 225K6HE N = None 25K6HE 300K6HE Model Number Example: 8DLX-75K6HE-13-BA2 30K6HE 500K6HE 1 Special voltages available, consult factory for model number. Output voltage selections A, B, and G only available on 1 phase systems; L and N only available on 3 phase systems. 2 50Hz models available, consult factory. 3 SPD = Surge Protection Device. Select A, B, or N. (See SPD option descriptions on Page 5) 4 300KVA and 500KVA models available in NEMA 1 enclosure only. NEMA 2 and 3R enclosures are not available for these KVA-rated models. MODEL SELECTION GUIDE SINGLE PHASE MODEL NUMBER 5 OUTPUT kva INPUT VOLTAGE 6 OUTPUT VOLTAGE 6 CABINET DIMENSIONS (IN.) 7 WEIGHT 8 5**X-5K6HE-*-*** 5 208, 240, or 480 120, 120/240, or 208 23W x 20D x 28H 170 5**X-8K6HE-*-*** 8 208, 240, or 480 120, 120/240, or 208 23W x 20D x 28H 225 5**X-10K6HE-*-*** 10 208, 240, or 480 120, 120/240, or 208 23W x 20D x 28H 300 5**X-15K6HE-*-*** 15 208, 240, or 480 120, 120/240, or 208 23W x 20D x 28H 370 5**X-20K6HE-*-*** 20 208, 240, or 480 120, 120/240, or 208 23W x 20D x 28H 390 5**X-25K6HE-*-*** 25 208, 240, or 480 120, 120/240, or 208 23W x 20D x 28H 420 THREE PHASE MODEL NUMBER 5 OUTPUT kva INPUT VOLTAGE 6 OUTPUT VOLTAGE 6 CABINET DIMENSIONS (IN.) 7 WEIGHT 8 8**X-15K6HE-*-*** 15 208, 240, 480, or 600 208/120 or 480/277 23W x 20D x 28H 370 8**X-30K6HE-*-*** 30 208, 240, 480, or 600 208/120 or 480/277 23W x 20D x 28H 495 8**X-45K6HE-*-*** 45 208, 240, 480, or 600 208/120 or 480/277 28W x 25D x 39H 700 8**X-75K6HE-*-*** 75 208, 240, 480, or 600 208/120 or 480/277 28W x 25D x 39H 830 8**X-112.5K6HE-*-*** 112.5 208, 240, 480, or 600 208/120 or 480/277 38W x 32D x 57H 1210 8**X-150K6HE-*-*** 150 208, 240, 480, or 600 208/120 or 480/277 38W x 32D x 57H 1470 8**X-225K6HE-*-*** 225 480 or 600 208/120 or 480/277 38W x 32D x 57H 1880 8**X-300K6HE-*-*** 300 480 or 600 208/120 or 480/277 56W x 41.5D x 48H 2656 8**X-500K6HE-*-*** 500 480 or 600 208/120 or 480/277 45W x 48D x 62.75H 4820 5 See Model Number Guide and Example above to complete model number. 6 Special voltages available on both single and three phase models, consult factory. Optional three phase voltages include 400/230, 460/266, or 600/347 VAC. 7 Reflects standard enclosure dimensions: NEMA 2 up to 225kVA; NEMA 1 at 300kVA and 500kVA. Consult factory for NEMA 3R enclosure dimensions. 8 Weight is based on K20 rated models and reflects unit weight only. Consult factory for shipping weight. WARRANTY: Controlled Power Company warrants the ULTRA-K Series 600K-he transformer (core and coil) to be free from defects in material and workmanship for a period of 1 year full, and an additional 24 years prorated. All other unit components are covered by a 2 year full replacement warranty. The warranty periods begin following the original factory ship date. QUALITY CERTIFICATION: Controlled Power Company is an ISO 9001:2015 certified company. Represented by: 1955 Stephenson Hwy., Troy MI 48083 www.controlledpwr.com email: info@controlledpwr.com Phone: (800) 521-4792 Fax: (248) 528-0411 All information and data within this brochure is subject to change without notice. UK-001-0617