DAITO DENSO MODEL. HFS30-24 Conducted Emission (VCCI-B) with Case Conditions Vin : 100VAC / 50Hz Iout : 100% Phase : WJ-01

Similar documents
DAITO DENSO MODEL. DFS50-24 Conducted Emission (VCCI-B) with Cover and Chassis Conditions Vin : 100VAC / 50Hz Iout : 100% Phase : WJ-01

LS200 TEST DATA IEC61000 SERIES

INDEX. 1. Electrostatic discharge immunity test E-1 ~ 2 (IEC )

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2

EMC standards. Presented by: Karim Loukil & Kaïs Siala

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

PH75A280-* RELIABILITY DATA 信頼性データ

アルゴリズムの設計と解析. 教授 : 黄潤和 (W4022) SA: 広野史明 (A4/A8)

RSEL-2003W RELIABILITY DATA

ZWS50B EVALUATION DATA 型式データ

RSHN-2003 RELIABILITY DATA

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

Energy Management Energy Meter Type EM110

RSEN-2200 RELIABILITY DATA

TDK-Lambda A C 1/27

08/07/2015

Series AM50E-NZ 50 Watt DC-DC Converter

Overcurrent Protection / 7SJ45

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Energy Management Energy Meter Type EM110

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

CER7027B / CER7032B / CER7042B / CER7042BA / CER7052B CER8042B / CER8065B CER1042B / CER1065B CER1242B / CER1257B / CER1277B

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

2620 Modular Measurement and Control System

Power Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report

D80 を使用したオペレーション GSL システム周波数特性 アンプコントローラー設定. Arc 及びLine 設定ラインアレイスピーカーを2 から7 までの傾斜角度に湾曲したアレイセクションで使用する場合 Arcモードを用います Lineモード

WAF S 12 W - N S DR Series Name Input Output Output Input Remote Control Load Share Assembly Voltage Quantity Voltage Range Option Option Option

Installation Manual WIND TRANSDUCER

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

TDK Lambda INSTRUCTION MANUAL. TDK Lambda C A 1/35

EMC Test report for LED Panel Light Models , , , , ,

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter

EMC TEST REPORT. Report No.: CE10-LIE040101E

CP-T range Product group picture

Output Voltage* (nom.)(adjustable)

Product Specification sheet

TDK Lambda C /35

Test and Measurement for EMC

Appendix A: Specifications

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

TDK-Lambda EFE300 EVALUATION DATA. Issue : Mod : Release Date : Initials : KM VP AC

Series AMSRL1-78JZ Up to 12 Watt DC-DC Switching Regulator

C series Product brief

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

CP-T range Benefits and advantages

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

MID energy meter B21 Single-phase energy meter, 65 A

08/07/2015

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

TDK Lambda WC /24

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

CONFORMANCE TEST REPORT FOR EN /-6

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TDK Lambda A /9

FS10 Series AC-DC Converter Compact Case(Power tank)

ELECTRONICS TESTING CENTER(ETC), TAIWAN

LED Driver. Input voltage range Vin=5.5-48V 0-15V Output current. Output current. range ±0.015 %/ C. Control voltage. range

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

LB115S 115W Single Output

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

PDAM500 Series 500W Power Supply

TEST REPORT. Power Spout PLT V. tested to the specification

Note1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

U N I T. 1. What are Maxine and Debbie talking about? They are talking about. 2. What doesn t Maxine like? She doesn t like. 3. What is a shame?

02/11/2015

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

High power density 3W Converter in SIP7 case. 3kVDC and 4kVDC Isolation Options

Load (2) Single or Dual

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

C B. Models. Models 2MOPP

50W Constant Current (700mA) Dimming LED Driver

HEC-30/35LTA-33TDAA Rev A

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

HEC-35LTA-XXTSAA Rev A

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

Packaging. nom. Output Voltage

CB Scheme UL508 UL ATEX II3G

LED Driver. Specifications Item Test condition Min Typ Max Units Utmost input voltage Recommended input voltage Min. Input-output Voltage Drop

IEC/EN/UL60950 & CE certified, EN55032 Class B

HEC-70LCN-350TDAF Rev B

P Z N V S T I. センサ信号入力仕様 Input signal type. 1 ~ 5 V 4 ~ 20 ma 1 ~ 5 V 4 ~ 20 ma 1 ~ 5 V 4 ~ 20 ma 1 ~ 5 V 4 ~ 20 ma

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

Scale Manufacturers Association (SMA) Recommendation on. Electrical Disturbance

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

500 ma DC-DC Step Down Converter P78G-Series

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

Transcription:

Conducted Emission (VCCI-B) with Case Conditions Vin : 100VAC / 50Hz Iout : 100% Phase : L Point A (-MHz) Ref. Limit Measure Data (dbuv) (dbuv) QP - - AV - - VCCI Class B QP Limit VCCI Class B AV Limit Phase : N Point B (-MHz) Ref. Limit Measure Data (dbuv) (dbuv) QP - - AV - - VCCI Class B QP Limit VCCI Class B AV Limit

Conducted Emission (EN55022-B) with Case Conditions Vin : 230VAC / 50Hz Iout : 100% Phase : L Point A (1.129MHz) Ref. Limit Measure Data (dbuv) (dbuv) QP 56.0 27.0 AV 46.0 20.9 A EN55022 Class B QP Limit EN55022 Class B AV Limit Phase : N Point B (-MHz) Ref. Limit Measure Data (dbuv) (dbuv) QP 56.0 26.8 AV 46.0 20.8 B EN55022 Class B QP Limit EN55022 Class B AV Limit

Radiated Emission (VCCI-B) with Case Conditions Vin : 100VAC / 50Hz Iout : 100% HORIZONTAL: VERTICAL:

Radiated Emission (VCCI-B) with Case Conditions Vin : 230VAC / 50Hz Iout : 100% HORIZONTAL: VERTICAL:

Electrostatic Discharge Immunity Test (IEC61000-4-2) Electro Static Discharge Simulator : Tokyo Metropolitan Industrial Technology Reserarch Institute Discharge Gun : Tokyo Metropolitan Industrial Technology Reserarch Institute Discharge Resistance : 330Ω Discharge Capacity : 150pF 2.Test Condition Input Voltage : 100VAC Output Voltage : Rated Output Power : 100% Polarity : +,- Number of Tests : 10 times Discharge Interval : 1 second Ambient Temperature : 25 3.Testing method and Device Test Point Contact Discharge : Case FG Air Discharge : +,-,FG Terminal AC INPUT D.U.T Discharge Probe V FG Load FG Analog Voltage Meter Aluminum Plate OUTPUT GND Electro Static Discharge Simulator Wood made Table 0.8m GND Plane 4.Acceptable Conditions 4-1. Output voltage regulation during the evaluation shall not be limited to ±5% of the initial value (value before evaluation). 4-2. Output voltage after the avaluation shall be stable at the initial value (within specification range). 4-3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 5.Test Result Contact Discharge Result Air Discharge Result (kv) (kv) 2 PASS 2 PASS 4 PASS 4 PASS 6 PASS 8 PASS 8 PASS 15 PASS

Radiated Radio-Frequency Electromagnetic Field Immunity Test (IEC61000-4-3) Tokatsu Techno Plaza 2.Test Condition Input Voltage : 100VAC/200VAC Output Voltage : Rated Output Power : 100% Amplitude modulated : 80%, 1kHz Electromagnetic Frequency : 80 ~ 1000MHz Ambient Temperature : 25 Distance : 2.1m Wave Angle : Horizontal and Vertical Sweep Condition : 1.0%Step Up, 2.8 seconds Hold Test Angle : Top/Bottom, Both, Both Sides, Front/Back 3.Testing method AC INPUT D.U.T V FG Load FG Analog Voltage Meter Aluminum Plate Antenna Wood made Table 0.8m GND Plane Anechoic Material to Reduce Floor Reflections 4.Acceptable Conditions 4-1. Output voltage regulation during the evaluation shall not be limited to ±5% of the initial value (value before evaluation). 4-2. Output voltage after the avaluation shall be stable at the initial value (within specification range). 4-3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 5.Test Result Radiation Field Strength Result (V/m) 1 PASS 3 PASS 10 PASS

HFS30 Electrical Fast Transient / Burst Immunity Test (IEC61000-4-4) EFT/B Generator : Tokatsu Techno Plaza 2.Test Condition Input Voltage : 100VAC/200VAC Output Voltage : Rated Output Power : 100% Test TIme : 1 minute Polarity : +,- Ambient Temperature : 25 Number of Tests : 3 times 3.Testing method and Device Test Point Apply to N, L, FG D.U.T FG V Load FG Analog Voltage Meter Aluminum Plate AC I NPUT 4.00 V EFT/B GENERATOR FG Wood made Table 0.8m GND Plane 4.Acceptable Conditions 4-1. Output voltage regulation during the evaluation shall not be limited to ±5% of the initial value (value before evaluation). 4-2. Output voltage after the avaluation shall be stable at the initial value (within specification range). 4-3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 5.Test Result Test Voltage Repetition Rate Result (kv) (khz) 0.5 5 PASS 1.0 5 PASS 2.0 5 PASS 4.0 2.5~100 PASS

Surge Immunity Test (EN61000-4-5) Surge Generator : Tokyo Metropolitan Industrial Technology Reserarch Institute Coupling Impedance : Common 12Ω Coupling Capacitance : Common 9uF : Normal 2Ω : Normal 18uF 2.Test Condition Input Voltage : 100 / 200 VAC Output Voltage : Rated Output Power : 100% Number of tests : 5 times Polarity : +,- Mode : Common,Normal Phase : 0,90,270deg Ambient Temperature : 25 3.Testing method and Device Test Point Apply to Common mode(n-fg, L1-FG) and Normal mode(n-l1) D.U.T SURGE GENERATOR FG V FG Load FG Analog Voltage Meter Aluminum Plate AC INPUT Wood made Table 0.8m GND Plane 4.Acceptable Conditions 4-1. Output voltage regulation during the evaluation shall not be limited to ±5% of the initial value (value before evaluation). 4-2. Output voltage after the avaluation shall be stable at the initial value (within specification range). 4-3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 5.Test Result Common mode Normal mode Test Voltage Result Test Voltage Result (kv) (kv) 0.5 PASS 0.5 PASS 1.0 PASS 1.0 PASS 2.0 PASS 2.0 PASS 4.0 PASS

Electrostatic Discharge Immunity Test (EN61000-4-6) RF POWER AMPLIFIER : Tokatsu Techno Plaza SIGNAL GENERATOR : Tokatsu Techno Plaza COUPLING DE-COUPLING NETWORK : Tokatsu Techno Plaza 2.Test Condition Input Voltage : 100 / 200 VAC Output Voltage : Rated Output Power : 100% Ambient Temperature : 25 Sweep Cndition : 1.0%Step Up, 2.8seconds Hold Electromagnetic Frequency : 150kHz~80MHz 3.Testing method AC INPUT RF INPUT CDN FG D.U.T V FG Load FG Analog Voltage Meter Aluminum Plate 0.1m GND Plane Wood made Table 4.Acceptable Conditions 4-1. Output voltage regulation during the evaluation shall not be limited to ±5% of the initial value (value before evaluation). 4-2. Output voltage after the avaluation shall be stable at the initial value (within specification range). 4-3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 5.Test Result Test Voltage Result (V) 1.0 PASS 3.0 PASS 10.0 PASS

HFS30 Power Supply-Frequency Magnetic Field Immunity Test (IEC61000-4-8) Tokatsu Techno Plaza 2.Test Condition Input Voltage : 100VAC/200VAC Output Power : 100% Ambient Temperature : 25 3.Test Result Input Frequency : 50Hz Level Magnetic Field Intensity (A/m) x :Supply Current (A) y :Supply Current (A) z :Supply Current (A) 1 1 1.40 PASS 1.40 PASS 2.44 PASS 2 3 4.20 PASS 4.21 PASS 7.32 PASS 3 10 14.00 PASS 14.04 PASS 24.39 PASS 4 30 42.00 PASS 42.13 PASS 73.16 PASS Input Frequency : 60Hz Level 1 1 2 3 3 10 4 30 Magnetic Field Intensity (A/m) x :Supply Current (A) y :Supply Current (A) z :Supply Current (A) 1.41 PASS 1.42 PASS 2.50 PASS 4.23 PASS 4.26 PASS 7.51 PASS 14.11 PASS 14.19 PASS 25.04 PASS 42.32 PASS 42.58 PASS 75.11 PASS

Vibration Test Vibration testing machine (Tokyo Metropolitan Small Busincss Promotion Agency) 2.Condition Mounting option fitting No operating Ambient temperature : +25 Sweep frequency : 10-55Hz Sweep time : 1min. Half-Amplitude : constant 1.0mm Direction : X,Y,Z Test time : 60 min. each Level : 19.6m/s 2 3.Testing method Device Under Test Y Fitting stage X Z Vibration direction Vibration testing machine 4.Results Vibration Direction X Y Z D.U.T.state(Before test) OK OK OK D.U.T.state(After test) OK OK OK 5.Judgment OK, NG

Shock Test Vibration testing machine (Tokyo Metropolitan Industrial Technology Research Institute) 2.Condition Mounting DIN rail No operating Ambient temperature : +25 Repetitive output : 1 times Pulse amplitude : 300m/s 2 Pulse duration : Nominal pulse : Half-sine Direction : X(+/-),Y(+/-),Z(+/-) 3.Testing method Y Device Under Test Fitting stage X Z Impact direction Impact testing machine 4.Results Shock Direction X(30G) Y(30G) Z(30G) + - + - + - D.U.T.state(Before test) PASS PASS PASS PASS PASS PASS D.U.T.state(After test) PASS PASS PASS PASS PASS PASS 5.Judgment OK, NG

HFS30,HFD30 Calculated values of MTBF 1. 算出方法 Part count reliability projection MIL-HDBK-217F NOTICE 2 の部品点数信頼度予測法により算出されています Calculated based on part count reliability projection of MIL-HDBK-217F NOTICE 2. < 算出式 > λ equip = i = n N i i= 1 ( λ π 1 6 1 6 MTBF = 10 = 10 i n λequip N ( λ ) g = i= 1 q ) i i g 式を簡単にする為に品質ファクタ πq=1 とする i [ 時間 ] [ hour] λ equi : 全機器故障率 ( 故障率 /10 6 時間 ) Total Equipment Failure Rate.(Failure/10 6 hour) λ g : i 番目の同属部品に対する故障率 ( 故障率 /10 6 時間 ) Generic Failure Rate for The ith Generic Part. Ni n πq : i 番目の同属部品個数 Quantity of ith Generic Part. : 異なった同属部品のカテゴリの数 Number of Different Generic Part Categories. : i 番目の同属部品に対する品質ファクタ Generic Quality Factor for The ith Generic Part. 2. MTBF 値 G F : 地上 固定 (Ground, Fixed) MTBF = 1 10 6 / 4.098 = 244,037 時間 27.9 年 hour year