FORTUS 360mc/400mc and FDM 360mc/400mc 3D Production System. Site Preparation Guide Rev E

Similar documents
Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Broadband Step-Up Transformer. User Manual

Your Performance Partner

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit

MODEL 3810/2 Line Impedance Stabilization Network

Z-5652 plus Series. 2D Image Hands-Free Scanner

External brake resistor AX2090-BW5x

V00029KX READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID

Please read and understand the OnBoard Timpani Cart Owner s Manual before using the Timpani Cart.

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

OPERATOR S MANUAL Model 58B Prefeed / Dereeler

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

COOPER POWER SERIES. External application of a motor start capacitor on a single-phase voltage regulator. Voltage Regulators MN225063EN

CEC VIBRATION TRANSMITTER

Smart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004.

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Mobile Activation Case

Double-Ridged Waveguide Horn Antennas

User s Guide. Agilent 16441A R-Box. Agilent Part No Printed in Japan January Edition 4

Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF

Dual-Band Wireless Adjustable Cellular Booster / Kit

Guide To Returning Your Satellite Modem and Radio Assembly Model: HN9000

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

SPM-50 RF Spectrum Power Meter PC Software User Manual

NANOSECOND PULSE GENERATOR NPG-18/3500(N) USER MANUAL

Model 72D Twin Blade Rotary Wire Stripper

User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002

NetShelter VX. Four-Post Open Frame. User s Manual

VT1586A Rack Mount Terminal Panel Installation and User s Manual

User and Installation Manual. For Tandem Arm and Slim Line Models. Tandem Arm. Slim Line

CAUTION: WEIGHT ON THIS PRODUCT SHOULD NOT EXCEED 136KG / 300LBS.

NANOSECOND PULSE GENERATOR NPG-15/2000(N) USER MANUAL

Keysight 16440A SMU/Pulse Generator Selector

Mighty Mo GX Series Cabinet Installation Guide. OR Rev /11

Model BiConiLog Antenna. User Manual

NOsparc User Manual IMPORTANT NOTES Arc Suppression Technologies. All rights reserved.

A-16D A-Net Distributor

200Amp AC Clamp Meter + NCV Model MA250

SIR-WRR1. User's Guide SIRIUS Echo Antenna. Signal Repeater System Accessory

Installing the IPS 4240 and the IPS 4255

User Guide. Keysight N6850A Broadband Omnidirectional Antenna

Preliminary Revised [ ] NOsparc User Manual. GGXAC1F480, GGXAC1F277, GGXAC1F240, and GGXAC1F120

BC145 SIGNAL ISOLATOR BOARD

Applications beyond concept modeling and general prototyping have stringent demands for qualifying a process

HT1100 Satellite Modem User Guide

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

2015 RIGOL TECHNOLOGIES, INC.

SUBNANOSECOND PULSE GENERATOR PPG-2/1000 USER MANUAL

Media Storage Systems Fixed Media Cabinets

Advanced Test Equipment Rentals ATEC (2832)

APS M1P Single-phase Micro-inverter Installation and User Manual

E2621A and E2622A Probe Adapters for Infiniium Oscilloscopes. User s Guide. Publication number E September 2002

SolarMount-I INSTALLATION MANUAL Broadway Boulevard NE Albuquerque, NM USA A HILTI GROUP COMPANY

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

Model 9305 Fast Preamplifier Operating and Service Manual

PULSE OXIMETRY SIMULATOR

VERTICAL PLATFORM LIFT

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

DC200A Displacement Clipper User Manual

N2790A Differential Voltage Probe

Radio Control Installation and Operating Instructions System 4

Distribution Amplifiers 1

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

Owner s Manual & Safety Instructions

WDMX-512. user manual

INSTRUCTION LEAFLET IL17537B F FRAME IQ ENERGY SENTINEL TM INSTALLATION INSTRUCTIONS FOR F FRAME IQ ENERGY SENTINEL TM

User s Guide. Model MA A AC Mini Clamp-on Meter

Model 1791 VHF Radio User's Manual

CURRENT MEARUREMENT SHUNT CS-10/500 USER MANUAL

200B Clipper Module User Manual

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

201AP Charge Amplifier User Manual

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

500S Smart Antenna Installation and Operation Manual. P/N Rev. A 09/17 E29808

HOLE CUTTER SHARPENER ASSEMBLY & SERVICE MANUAL

Owner s Manual & Safety Instructions

Agilent 1146A AC/DC Oscilloscope Current Probe

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

TETRIS 1000 High Impedance Active Probe. Instruction Manual

PWM-T210 Installation Instructions UNIVERSAL FLAT PANEL MOUNT

2-in-1 AIR TANK AND BEAD BLASTER OWNER S MANUAL

Current Probes. User Manual

Pen Multimeter. Model

For detailed specifications and ordering info go to

Advanced Test Equipment Rentals ATEC (2832)

A-dec 300 P RE-INSTALLATION GUIDE

Agilent G1888 Network Headspace Sampler

Installation Instructions

Digivance External Notch Filter Installation Instructions

PKT 512A-RO High Impedance Passive Cable Divider

TETRIS User's Guide. High Impedance Active Probe DO177-1

Circuit Breaker Finder

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

OPERATOR S MANUAL Model 77E Pneumatic Cable Stripper

Operating and Service Manual

DIGITAL AUDIO AMPLIFIER WITH BLUETOOTH. Model: DAA User Manual

ELECTROSURGICAL UNIT ANALYZER

Protector Standard Base Storage Cabinets are utilized for general storage and are not recommended for corrosive or flammable materials.

Transcription:

FORTUS 360mc/400mc and FDM 360mc/400mc 3D Production System Site Preparation Guide 107167-0005 Rev E

Liability Statement The information in this document is subject to change without notice. Stratasys, Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Stratasys, Inc. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document is protected by copyright. All rights reserved. Its use, disclosure, and possession are restricted by an agreement with Stratasys per software copyright. No part of this document may be photocopied, reproduced or translated into another language without the prior written consent of Stratasys, Inc. All drawings and information herein are the property of Stratasys Inc. All unauthorized use and reproduction is prohibited. Trademark Acknowledgments Stratasys, Insight, FORTUS, and FDM are registered trademarks of Stratasys, Inc. FORTUS 360mc/400mc and FDM 360mc/400mc are registered trademarks and service marks of Stratasys Inc. in the United States and other countries. All other product names are the property of their respective owners. Stratasys Incorporated 7665 Commerce Way Eden Prairie, MN 55344 USA 952.937.3000 Fax: 952.937.0070 www.stratasys.com Copyright 2010 Stratasys Inc. All rights reserved. Printed in the United States of America ii

Table of Contents How To Use This Guide 1 Highlighted Information 1 Introduction 1 How To Use This Guide 1 Highlighted Information 1 Site Prep Tasks 2 Selecting the Site 2 Dimensions and Weights 2 Space Requirements 2 Environmental Requirements 3 Compressed Air Specifications 3 Heat Output 3 Electrical Requirements 3 Power Quality 4 Nominal Voltage Level 4 Transformer Installation 4 LAN Requirements 5 Receiving the System 5 Check System Code 5 Inspect Crate for Damage 5 Preparing the System for Final Installation 5 Required Tools and Equipment 5 Unpacking the System 6 Remove shipping materials 6 Inspect system exterior 6 Remove system from shipping base 6 Service Connections 7 iii

Revision Log FORTUS 360mc/400mc and FDM 360mc/400mc Site Preparation Guide Revision Date Description of Changes A July 2007 Updated manual B January 2008 Updated manual C December 2008 Updated manual D July 2009 Updated manual E June 2010 Format changed and document update. Safety Safe Environment The following basic safety tips are given to ensure safe installation, operation, and maintenance of Stratasys equipment and are not to be considered as comprehensive on matters of safety. The Fortus 360mc/400mc and FDM 360mc/ 400mc system is designed to be safe and reliable rapid prototyping system. Access to areas of the system are potentially dangerous. Connect equipment to a grounded facility power source. Do not defeat or bypass the ground lead. Know the location of equipment branch circuit interrupters or circuit breakers and how to turn them on and off in case of emergency. Know the location of fire extinguishers and how to use them. Use only ABC type extinguishers on electrical fires. Know local procedures for first aid and emergency assistance at the customer facility. Use adequate lighting at the equipment. Maintain the recommended range of temperature and humidity in equipment area. Do not use this product in an environment containing volatile or flammable compounds. iv

How To Use This Guide Highlighted Information Introduction This guide provides information for selecting an appropriate location for the FORTUS 360mc/400mc and FDM 360mc/400mc systems and are referred to throughout this guide as the 360mc/400mc. This guide also provides instructions for unpacking and preliminary system set-up. Information of particular importance is presented in one of three formats: How To Use This Guide Highlighted Information This guide provides information for selecting an appropriate location for the Fortus 360/400mc system and FDM 360mc/400mc systems and are referred to throughout this guide as the 360mc/400mc. It also provides instructions for unpacking and preliminary system set-up. Information of particular importance is presented in one of three formats: A WARNING indicates a procedure that may cause Injury to an operator if the procedure is not followed. A WARNING will precede the paragraph of instruction to which it relates. A CAUTION indicates a procedure that may cause Damage To Equipment if the procedure is not followed. A CAUTION will precede the paragraph of instruction to which it relates A NOTE is used to highlight a specific point or to provide an operational tip. While useful, a NOTE does not indicate a procedure that can cause injury or damage if it is not followed. A NOTE will follow the paragraph of instruction to which it relates. FORTUS 360mc/400mc and FDM 360mc/400mc Site Preparation Guide 1 of 8

Site Prep Tasks Selecting the Site Decide where to install the system based on the following: 1. Space Requirements 2. Environmental Requirements 3. Electrical Requirements 4. LAN Requirements Dimensions and Weights Make sure that the installation site floor space can accommodate the system weight and dimensions (plus required clearances - see Space Requirements on page 2). System Size: (Uncrated) (Crated) System Weight:: Ship Weight: Space Requirements Side Clearance: Rear Clearance: Front Clearance: Vertical Clearance: Width: 50.5 inches (128 cm) Depth: 35.25 inches (89.64 cm) Height: 77.25 inches (195.63 cm) Width: 58.25 inches (147.96 cm) Depth: 42.75 inches (108.59 cm) Height: 86.5 inches (219.71 cm) 1309 pounds (593 kg) 1511 pounds (687 kg) 30 inches (76.29 cm) on each side 12 inches (30.28 cm) 36 inches (91.44 cm) 28 inches (71.12 cm) 2 of 8 FORTUS 360mc/400mc and FDM 360mc/400mc Site Preparation Guide

Environmental Requirements The 360mc/ 400mc system is for indoor use only. Maximum temperature of operating environment: 85 F (29 C) Maximum dew point: 78 F (25 C) Compressed Air Specifications Heat Output Supply pressure at the system: 55 psi with a minimum flow of 2.5 CFM. The maximum pressure must be less than 145 psi. Non-lubricated Non-condensing DIN ISO 8573-1 Quality Class 5 or better is recommended to improve onboard filter life. Connection: The air source connection must meet dimensional standard A-A-59439 for the quick disconnect female ¼-inch coupler. The system has a standard ¼-inch quick disconnect male plug (A-A-59439). 12,000 BTU/hr - Max. Electrical Requirements If a pump in a box was purchased, the pump must be located at least 12 in. (30.28 cm) away from the system. The maximum distance away from the system must not exceed 25 ft. (7.62 m). Power Quality is Key to Best Performance The 360mc/ 400mc system is a precision tool that requires good power quality. Its design incorporates a number of power quality control measures. Customers are required to meet the power quality and nominal voltage requirements. It is strongly encouraged that you contact a 3 phase UPS or Line Conditioner Vendor if you cannot meet the requirements. Within the USA, a Badger transformer is suppled with the systems. Badger Transformer Part Number: 200, 208, 220, or 240 3ATEG64SPB0B 380, 400, 415, or 440 3ATEG64WPB0B 480 3ATEG64ZPB0B FORTUS 360mc/400mc and FDM 360mc/400mc Site Preparation Guide 3 of 8

Power Quality Nominal Voltage Level Transformer Installation We recommend that your system be operated on a dedicated 3-phase line meeting the recommendations for power quality given in IEEE Standard 141-1976 and FIPS PUB 94. Customers who are unsure of their power quality should contact their local provider. The Nominal AC Line Voltage requirements of your T-Class system are 230 VAC 3-Phase ± 5%, frequency of 46 Hz to 65 Hz stable, phase balance ± 3%, and a 20 amp circuit. Operation of your system outside this range, even for short periods, is not recommended, as it will result in degraded system performance and component life expectancy. The ideal output voltage from the transformer is 230 VAC to 235 VAC. A licensed electrician must perform all wiring from service connect to the transformer, and from the transformer to the system - including all connectors, cables and proper strain relief. Improper installation of a transformer, or installation of a transformer not meeting system requirements, may invalidate the warranty and/or cause performance problems. A licensed electrician must perform all wiring from service connect to the transformer, and from the transformer to the system - including all connectors, cables and proper strain relief. Improper installation of a transformer, or installation of a transformer not meeting system requirements, may invalidate the warranty and/or cause performance problems. Typical Transformer Schematic Figure 1: Transformer Schematic (Typical) 4 of 8 FORTUS 360mc/400mc and FDM 360mc/400mc Site Preparation Guide

LAN Requirements A LAN connection is required for communication and file transfer functions. The LAN connection is a 100 base T, Ethernet protocol, RJ45 connector. (One 25-ft. CAT5, 10/100 base T cable is supplied with the system.) The 360mc/400mc will accept either DHCP or static IP address configurations. Receiving the System Check System Code Before delivery, Stratasys provides, by email, a system specific installation code. This code is necessary for initial system startup. Verify that you have received the code from Stratasys. Inspect Crate for Damage Systems configured with a network option of UPnP=ON will occasionally broadcast a unique system identifier across the network for use by the Insight FDM Control Center software application. Refer to Insight user information for workstation requirements. Before opening the shipping crate, inspect the crate for signs of exterior damage. Report evidence of excessive damage to Stratasys and the shipping company. Preparing the System for Final Installation Required Tools and Equipment Basic hand tools. Forklift of sufficient size to raise the system from the shipping base. See Ship Weight: 1511 pounds (687 kg) on page 2. FORTUS 360mc/400mc and FDM 360mc/400mc Site Preparation Guide 5 of 8

Unpacking the System Remove shipping materials 1. Remove screws (phillips) securing the cardboard cover to the base. Wear safety glasses when removing the shipping bands. Inspect system exterior 2. Carefully cut the shipping bands. 3. Remove the cardboard cover. 4. Remove the two end walls of the shipping container (two-part triple wall sleeve). 5. Remove the two foam protectors from the top of system. Use care when removing the plastic wrap to avoid scratching the system surfaces. 6. Carefully remove plastic wrapping and plastic bag from the system. 7. Inspect the system exterior for dents and scratches. Immediately report any damage to Stratasys and the shipping company Remove system from shipping base Access the forklift Openings from the REAR ( back ) of the system 8. Using a forklift, carefully raise the system and remove the shipping base. Figure 2. Forklift Openings Figure 2: Forklift Openings 9. Gently lower the system, until it rests on its wheels. 6 of 8 FORTUS 360mc/400mc and FDM 360mc/400mc Site Preparation Guide

10. Roll the system into its approximate operating location. Service Connections Position the system to allow at least three feet of clearance on all sides until the installation process is complete. See Space Requirements on page 2. Final installation and setup must be accomplished by a qualified service representative. A licensed electrician must perform all wiring from service connect to the transformer, and from the transformer to the system - including all connectors, cables and proper strain relief. Comply with all applicable local and national electric codes. Do not apply power to the FDM System until the Stratasys field service engineer has verified that the proper connections have been made. 11. A dedicated 20 amp 3-phase power source is required. 12. The transformer does not include a power switch or a circuit breaker. It is recommended that an emergency On/Off switch be located between the power panel and the transformer. 13. Connect the system to the transformer as follows: (Figure 3) Line 1 connects to terminal block L1. Line 2 connects to terminal block L2. Line 3 connects to terminal block L3. Neutral has no connection. Ground connects to lug located inside the electrical panel. Do not terminate to the door. Minimum wiring length for (3) incoming AC phases is 7 inches (178 mm) from strain relief. Minimum wiring length for ground wire is 12 inches (305 mm) from strain relief. A licensed electrician must perform all wiring from service connect to the transformer and system including connectors, cables and proper strain relief. Consult a licensed electrician to comply with all applicable local and national electric codes. FORTUS 360mc/400mc and FDM 360mc/400mc Site Preparation Guide 7 of 8

Ground connection Figure 3: Line Connections 8 of 8 FORTUS 360mc/400mc and FDM 360mc/400mc Site Preparation Guide