BUTTERFLY VALVES VIC SERIES. High Performance for a Wide Range of Applications. of applications. percent leakage capability at each valve s

Similar documents
BUTTERFLY VALVES VIC SERIES. High Performance for a Wide Range of Applications. of applications. percent leakage capability at each valve s

F6 VIC Butterfly Valves Way Ductile Iron Grooved End Body

F6/F7...HD/HDU Series Butterfl y Valves

B6300VB-207, 3, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F650HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

B2...VS Series, 2-way, Ball Valve Bronze Body, Stainless Steel Ball and Stem

F6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F680HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6125HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

B2150VB-055, 1-1/2, V Ball Control Valve Hardened Chrome Plated Carbon Steel Body, Stainless Steel Ball and Stem

B6400VB-350, 4, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem

P2050B050, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

P2075B100-P, 3/4, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

P2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

B212, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

B240, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

B250, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

B6400S-186, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

F780HD, 3, 3-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6 Series 2-Way, Victaulic Butterfly Valve

V Ball Control Valve Product Range

B350L, 3-Way, Diverting Ball Valve Chrome Plated Brass Ball and Nickel Plated Brass Stem

B2 Series Characterized Control Valve, Spring Return Actuator

4CONTROL VALVES CONTROL VALVES ULTRAFLO BUTTERFLY VALVES 522 SERIES NEW! H2X E2X KMSC-0 SPECIFICATIONS

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

Technical Documentation Electronic Characterized Control Valves (CCV)

Ball Valve Features and Benefi ts B2...VS / VSS and B3...L

DIN (NFPA/ISO/CETOP) NG6 (3) NG10

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

Wiring for Damper Actuators and Control Valves July 2011

E Series. Electric Actuators. Approved. On-Off and Modulating Electric Actuators Torques to 30,000 in. lbs. Weatherproof Construction

DIN NG10 NG25 NG32 ISO/CETOP

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Value Valves USA. Electric Actuator DOUBLE ACTING SPRING RETURN.

FEATURES OPTIONAL FEATURES

AD-8100 & AD-8200 Servo Amplifiers

The International Power Quality Resource

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

OPERATION MANUAL. Spring Return Actuator. Electrical Actuator. September, st

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

7000 Series Bronze Globe Valves Two-Way Normally Open

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.

NK Technologies Ground Fault Sensor. Instrument Transformer AC Current Transducers NEW SPECIFICATIONS

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

Digital E-BM-TEB/LEB drivers DIN-rail panel format, for proportional valves with one or two spool position transducers

This specification describes the minimum requirements for piping systems for the following service:

LA-5000 SERIES LINEAR VALVE ACTUATORS

P3-HSI High Speed Isolated Sinking/Sourcing Input

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

Absolute encoders multiturn

OPERATION MANUAL. Linear Valve Actuator. Electrical Valve Actuator. September, nd

REACTa. Installation Commissioning Maintenance Installation circular version Legend to figures 3-5: Min. 500 mm. Min.

DCS-62 Series Spring Return Electronic Actuator Product Bulletin

AE SERIES ACTUATORS. Electric Actuators. Standard Voltages 110/240/380/480V 24VAC/24VDC. Modulating Capable. 100% Duty Cycle Models Fast Acting Models

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Absolute encoders multiturn

Electric Actuator. of innovated design. Introducing KIMAX CONTROLS INC. > Patented switch of manual & Motor operation. Clutchless manualoverride.

CDNBS08-SLVU Low Capacitance TVS Array

Solenoid valve for high vacuum. Orifice: 1, 2, 3, 4.5, 6. NC (normally closed) type. Cv flow factor (*4) Working pressure range Pa (abs)

BFS / BFSM SERIES Installation & Maintenance Manual

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

Reliance SG800 Series Steel Water Gage Valves

AE SERIES ACTUATORS 2016 EDITION. The Best Way To Automate Your Process. Modulating Capable. Extended Duty Cycle Models Fast Acting Models

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

Spring Return DuraDrive Proportional Actuator

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

ICM/ICAD Motorized Valve. Quick Start Guide. Installation, Programming, and Trouble-shooting REFRIGERATION & AIR-CONDITIONING

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration

G-Series Servomotors. AC Brushless Servomotors. Understanding the G-Series Servomotor Model Numbers

Series 70 24V and 120V Actuator 600 to 18,000 lb.-in.

150 C 30 F B D 8L 152H C 30 F BD 43 8L

MODEL: MRP6. Final Control Elements

Compact CANopen. RoHS 2/22. Shock / vibration resistant. High shaft load capacity e

WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Reliance SG777 Series Steel Water Gage Valves

MOTORIZED VALVES SHANGHAI INJOY INDUSTRY CO.,LTD.

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd

Instructions for Installation. S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection TABLE OF CONTENTS INTRODUCTION INSTALLATION

Boring. Reaming. Burnishing. Threading. Drilling. Opening Drill. Large Diameter Replacable IC Insert Drilling System. Specials

Electric actuator for quarter-turn valves. For output torques to 17,700 lb. in.

Part No. Thread Size B Design Load Approx. Wt./100 A in. (mm) Lbs. (kn) Lbs. (kg)

DirectConnect Kit. For Liquid & NH3 Application Control

This specification describes the minimum requirements for piping systems for the following service:

LPK1550 Hydraulic Crimping Tool 15-ton

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

2/2 way Proportional Valve (motordriven)

Electric actuator for quarter-turn valves. For output torques to 17,700 lb. in.

Plug & Play. No Calibration Required

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

Paddle wheel flow controller for On/Off control

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

$

Transcription:

UTTRLY VLVS VI SRIS High Performance for a ide Range of pplications rooved butterfl y valves meet a wide range of applications. dvanced seat and disc design provides zero percent leakage capability at each valve s rated temperature/pressure while maintaining a low seating torque.

utterfly Valve Nomenclature 6 50 VI PRX UP MT -T Valve 6 = 2-way 7 = 3-way Valve Size 50 = 2 65 = 2½ 80 = 3 100 = 4 125 = 5 150 = 6 200 = 8 250 = 10 300 = 12 Trim Material -VI = uctile Iron rooved nd ody, Nickel oated uctile Iron isc, 0% Leakage up to 200 psi ctuator Type Non-Spring Return M(X) M... N4(H) M(X) R(X) R... N4(H) PR SY lectronic ail-safe K PK Spring Return Power Supply -24 = 24 V/ -110 = 110/120 V -120 = 120 V -230 = 230 V UP = 24-240 V or 24-125 V ontrol -3-X1 = On/Off, loating Point MT or MT-X1 = Multi-unction Technology -S = uilt-in uxiliary Switch N4 = NM 4/4X N4H = NM 4 with Heater -T = Terminal Ordering xample 1 hoose the valve actuator combination. 650H+PRXUP-MT 2 2-way Preference Specify preference or confi guration. Set-Up 3 +NO or MT orders only - select programming code (consult factory) +Tagging (if needed) 3-way onfiguration 4 oes order require tagging? Spring Return 2 Pos. Modulating N NO NO/O N/ NO/ N/O Set Up Required ield Logic etermines Normal Position (Normally losed) 0.5 V/2 V/4m = losed (Normally Open) 0.5 V/2V/4m = Open (Normally Open/ail Open) ield Logic etermines Normal Position Spring ails Valve OPN (Normally losed/ail losed) ield Logic etermines Normal Position Spring ails Valve LOS (Normally Open/ail losed) 0.5 V/2V/4m = Open Spring ails Valve LOS (Normally losed/ail Open) 0.5 V/2V/4m = losed Spring ails Valve OPN 2 Pos. Modulating Spring Return Modulating 2 Pos. Specify low Pattern Specify low Pattern No Set Up Required ield Logic etermines Normal Position Master (ctuated) Valve N (Normally losed) 0.5 V/2 V/4m = losed Master (ctuated) Valve NO (Normally Open) 0.5 V/2V/4m = Open NO/O (Normally Open/ail Open) ield Logic etermines Normal Position Spring ails Master Valve OPN N/ (Normally losed/ail losed) ield Logic etermines Normal Position Spring ails Master Valve LOS NO/O (Normally Open/ail Open) 0.5 V/2V/4m = Master Valve Open Spring ails Master Valve OPN NO/ (Normally Open/ail losed) 0.5 V/2V/4m = Maser Valve Open Spring ails Master Valve LOS N/O (Normally losed/ail Open) 0.5 V/2 V/4m = Master Valve losed Spring ails Master Valve OPN N/ (Normally losed/ail losed) 0.5 V/2 V/4m = Master Valve losed Spring ails Master Valve LOS Tagging: Valves may be tagged per customer specifi cation. ($10.00 per tag) xample: hiller 1 3rd loor ast Part number for tagging: 99981-00101 5 omplete Ordering xample: 650H+PRXUP-MT+NO +L05 onsult factory

ontrol Valve Product Range rooved utterfly Valve Product Range v 90 v 60 2-way Valve Nominal Size IN N [mm] Suitable ctuators Type Non ail-safe ail-safe 2-way 115 2 50 650VI 260 80 2½ 65 665VI 440 140 3 80 680VI 820 250 4 100 6100VI 1200 370 5 125 6125VI 1800 560 6 150 6150VI 3400 1050 8 200 6200VI 5800 1800 10 250 6250VI 9000 2790 12 300 6300VI M Series M Series R Series PR / PKR Series SY (2 Year arranty) Spring Return Series lectronic K PKR Series Mode of Operation rooved butterfly valves are designed for body pressures ranging from full vacuum to 300 psi and for bi-directional, dead end services to full body pressure. The valve patented seat design ensures full 0 sealing. The pressureenhanced seat compresses to form a larger seating area as the pressure increases. Valve construction and performance meet and exceed MSS-SP-67 requirements. Product eatures The unique single offset disc and seat design ensures positive valve seating while maintaining low seating torque. Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. v 90 v 60 3-way Valve Nominal Size IN N [mm] Suitable ctuators Type Non ail-safe ail-safe 3-way 115 2 50 750VI 260 80 2½ 65 765VI 440 140 3 80 780VI 820 250 4 100 7100VI 1200 370 5 125 7125VI 1800 560 6 150 7150VI 3400 1050 8 200 7200VI 5800 1800 10 250 7250VI 9000 2790 12 300 7300VI M M Series PR / PKR Series SY Series (2 Year arranty) Spring Return lectronic PKR Series ontrol type Manual override lectrical connection ommunication (PR) Valve Specifications on/off, fl oating point, modulating, 2-10 V, multi-function technology (MT) all models 3 ft. [1 m] cable terminal block (-T models) net MS/TP, N, listed by TL Service chilled, hot water, 60% glycol low characteristic 6 modifi ed equal percentage 7 modifi ed linear Sizes 2 to 12 nd fi tting grooved NSI/ (606) Materials* ody ductile iron STM 5, grade 65-45-12 ody fi nish black alkyd enamel isc electrolysis nickel coated ductile iron Shaft 416 stainless steel Seat PM earings fi berglass with T lining Media temp. range -22 to +250 [-30 to +120 ] ody pressure rating 300 psi lose-off pressure 200 psi (for most combinations) Rangeability 100:1 Maximum velocity Leakage 0% 20 PS *VI 300 Masterseal is manufactured by Victaulic ompany 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI 3

eatures and enefits VI Victaulic utterfly Valves elimo VI.. Series Victaulic utterfl y Valves are designed for pressure ranging from vacuum to 300psi and for dead end services Valve esign eatures The valve features a patented seat design that assures full 0 sealing. The pressure enhanced seat compresses to form a larger seating area as the pressure increases. The seat design also contributes to low breakaway torque of the valve. Valves have PM seats that are L classifi ed to NSI/NS 61. The disc is ductile iron, conforming to STM -5, grade 65-45-12 with electrolysis nickel coating conforming to STM -733. Stem is 416 stainless steel conforming to STM -582. to full working pressure. ll Vitaulic valves are supplied in grooved style body design. RIV HU esigned to accept nearly all types of actuation. ISO 5211 MOUNTIN LN ccepts ISO standard actuators. 2-8 / 50-200 mm are fl ange size 07. 10-12 / 250-300 mm are fl ange size 10. STM SLS Prevents leakage of media. ROOV N OY Reduces the weight of the valve and makes it easier to install. UPPR N LOR STM RINS Helps maintain constant low torque values for the life of the valve. THRML RRIR Reduces condensation on gear operators when installed in chilled water applications. SL RTRI Patented seal cartridge houses stem seals. STM lowout proof design utilizing stainless steel. RTNULR RIV Positive rectangular drive eliminates fastners in the flow stream. esign prevents replacement errors. ST Patented pressure enhanced rubber seat design. IS lectroless nickel coated ductile iron. Optional: luminum ronze Stainless Steel Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. 4 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN

VI Series utterfly Valves Standard ctuation (verage ssembly eights) 2-Y 3-Y NON-SPRIN RTURN SPRIN RTURN LTRONI IL-S Size Valve Max PM OP M(X) M(X) 2*M(X)... 2*... 2*K... 2 650VI 118 200 14 lbs. 14 lbs. 2.5 665VI 184 50/200 14 lbs. 14 lbs. 24 lbs. 3 680VI 264 200 16 lbs. 25 lbs. 4 6100VI 470 200 32 lbs. 51 lbs. 2 750VI 118 50/200 46 lbs. 53 lbs. 46 lbs. 2.5 765VI 184 50/200 55 lbs. 65 lbs. 3 780VI 264 50 70 lbs. 72 lbs. Industrial ctuation (verage ssembly eights) Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. 2-Y 3-Y TUTOR NON-SPRIN RTURN Size Valve Max PM OP R PR/PKR SY4 SY5 SY6 SY7 2 650VI 118 200 15 lbs. 2.5 665VI 184 200 15 lbs. 3 680VI 264 50/200 16 lbs. 40 lbs. 4 6100VI 470 200 40 lbs. 5 6125VI 734 50 46 lbs. 6 6150VI 1058 200 50 lbs. 8 6200VI 1880 200 64 lbs. 10 6250VI 2938 200 81 lbs. 12 6300VI 4230 200 101 lbs. 2 750VI 118 200 47 lbs 2.5 765VI 184 50/200 57 lbs. 72 lbs. 3 780VI 264 200 80 lbs. 4 7100VI 470 200 130 lbs. 5 7125VI 734 200 160 lbs. 6 7150VI 1058 200 210 lbs. 8 7200VI 1880 200 276 lbs. 10 7250VI 2938 50 456 lbs. 12 7300VI 4230 200 645 lbs. Max PM = Maximum US gallons of water (gpm) per minute, at room temperature, that will flow through the fully open valve without exceeding design velocity limits. OP = lose-off Pressure stated in psi. This is the maximum differential pressure the valve will close-off against while maintaining a bubble tight seal. ll SY and PR/PKR series actuators are NM 4X rated and include 2 auxiliary switches and a heater. 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN 5

utterfly Valve Selection Velocity hart and Installation VI Series Valves ONI O X10 ON/O OR MO@2 V MSTR VLV IS OPN MSTR VLV @ IL IL IN PL ONI O X20 ON/O OR MO@2 V MSTR VLV IS OPN MSTR VLV @ IL IL IN PL ONI O X30 ON/O OR MO@2 V MSTR VLV IS OPN MSTR VLV @ IL IL IN PL X11 OPN OPN X21 OPN OPN X31 OPN OPN X12 OPN LOS X22 OPN LOS X32 OPN LOS X13 X14 LOS LOS OPN X23 X24 LOS LOS IL IN PL OPN X33 X34 LOS LOS IL IN PL OPN X15 LOS LOS X25 LOS LOS X LOS LOS X Specifies i-irectional low apability Notes: 1. Slave Valve operates inversely of the Master Valve. 2. The Master Valve is always located on the run. 3. The Slave Valve may also have an actuator if required (irect oupled). 4. On/Off actuator normal position is a function of field logic. 5. Modulating actuator normal position (i.e., fully or fully ) is set by the direction control switch or field programming via N app. 6. ll 3-way assemblies are designed for 90 degree actuator rotation. 7. ctuators installed default over Master Valve. VI low in Schedule 40 Pipe (luid Velocity in PM). Use with rooved Series utterfl y Valves. SIZ 1 PS 3 PS 5 PS 8 PS 10 PS 12 PS 15 PS 16 PS 20 PS 2 10 31 52 84 105 126 157 167 209 2½ 15 45 75 119 149 179 224 239 298 3 23 69 115 184 230 277 346 9 461 4 40 119 198 317 397 476 595 6 794 5 62 187 312 499 624 748 9 998 1247 6 90 270 450 720 900 1081 11 1441 1801 8 156 468 780 1247 1559 1871 2339 2495 3119 10 246 737 1229 1966 2458 2949 87 3932 4916 12 3 1058 1763 2820 25 4230 5288 5640 7050 Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. 6 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN

SY... Series Non-Spring Return ctuator imensions SY-4~6... SY-9~12... SY-7~8... Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. MOL IM (MX) dd to im for cover removal IM IM (MX) IM Inches [mm] Inches [mm] Inches [mm] Inches [mm] Inches [mm] SY4~6 12.40 [315] 8.86 [225] 9.21 [234] 14.96 [380] 11.81 [300] SY7~8 16.54 [420] 8.86 [225] 9.21 [234] 17.72 [450] 13.39 [340] SY9~12 23.23 [590] 8.86 [225] 10.24 [260] 18.50 [470] 13.78 [0] Note: ~ indicates range of actuator i.e., SY4~6 = SY-4 and SY-5 and SY-6 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN 7

ire Size vs. Length of Run for SY Series ctuators SY1 SY2 SY3 SY4 SY5 mps mps mps mps mps wire gauge 2.00 3.60 3.60 11.00 10.20 MX istance between ctuator and Supply (feet) 18 77 43 43 16 122 68 68 22 24 14 195 108 108 38 12 310 172 172 56 60 10 493 273 273 89 96 8 784 4 4 142 153 24 V SY1 SY2 SY3 SY4 SY5 SY6 SY7 SY8 SY9 SY10 SY11 SY12 mps mps mps mps mps mps mps mps mps mps mps mps wire gauge 0.6 0.7 0.7 2.4 2.3 2.2 1.7 2.6 3.4 4.0 3.0 3.4 MX istance between ctuator and Supply (feet) 18 1287 1103 1103 322 3 1 454 297 227 193 257 227 16 2042 1750 1750 511 533 557 721 471 0 306 408 0 14 3253 2788 2788 813 849 887 1148 751 574 488 651 574 12 5167 4429 4429 1292 1348 1409 1824 1192 912 775 1033 912 10 8218 7044 7044 2054 2144 2241 2900 1896 1450 1233 1644 1450 8 13072 11205 11205 3268 3410 65 4614 3017 2307 1961 2614 2307 110 V SY1 SY2 SY3 SY4 SY5 SY6 SY7 SY8 SY9 SY10 SY11 SY12 mps mps mps mps mps mps mps mps mps mps mps mps wire gauge 0.4 0.4 0.4 1.1 1.0 1.1 0.8 1 1.1 1 1.9 2.0 MX istance between ctuator and Supply (feet) 18 3701 3701 3701 1346 1480 1346 1851 1057 1346 1057 779 740 16 5871 5871 5871 21 2348 21 39 1677 21 1677 12 1174 14 92 92 92 3401 3741 3401 4676 2672 3401 2672 1969 1870 12 14854 14854 14854 5402 5942 5402 7427 4244 5402 4244 3127 2971 10 227 227 227 8592 9451 8592 11813 6750 8592 6750 4974 4725 8 37583 37583 37583 166 15033 166 18791 10738 166 10738 7912 7517 220 V The N mandates that 24 V over 100 V power requires LSS 1 wiring conduit. Local codes may vary. o NOT mix LSS 1 & LSS 2 circuits in the same conduit. enerally, 24 V actuators over 100 V should be changed to 120 V models. Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. 8 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN

utterfly Valve ctuators Power Supply 24 V/V Single Phase Model # Torque Speed 50 Hz/60 Hz urrent raw urrent raw PRUP-3-T* 1400 in-lbs/ 160 Nm seconds 0.8 0.8 20 20 20 20 Manual override crank 5.8 kg/12.8 lbs. PRXUP-3-T* 1400 in-lbs/ 160 Nm, 30-120 seconds V V Override eight 0.8 0.8 20 20 20 20 Manual override crank 5.8 kg/12.8 lbs. SY4-24 40 in-lbs/ 400 Nm 30 seconds 9.5 9.5 208 212 228 228 Hand wheel 22 kg/48.5 lbs. SY5-24 4430 in-lbs/ 500 Nm seconds 9.3 9.4 178 168 223 227 Hand wheel 22 kg/48.5 lbs. Power Supply 120 V Single Phase Model # Torque Speed 50 Hz Speed 60 Hz urrent raw urrent raw PRUP-3-T* 1400 in-lbs/ 160 Nm seconds seconds 0.2 0.2 18 18 23 23 Manual override crank 5.8 kg/12.8 lbs. PRXUP-3-T* 1400 in-lbs/ 160 Nm, 30-120 seconds, 30-120 seconds V V Override eight 0.2 0.2 18 18 23 23 Manual override crank 5.8 kg/12.8 lbs. SY4-110 40 in-lbs/ 400 Nm 21 seconds 18 seconds 2.2 1.8 240 196 264 216 Hand wheel 22 kg/48.5 lbs. SY5-110 4430 in-lbs/ 500 Nm 29 seconds 25 seconds 2.2 1.8 242 193 264 216 Hand wheel 22 kg/48.5 lbs. SY6-110 5750 in-lbs/ 650 Nm 37 seconds 32 seconds 2.2 1.8 247 198 264 216 Hand wheel 22 kg/48.5 lbs. SY7-110 8850 in-lbs/ 1000 Nm 59 seconds 49 seconds 6.4 3.5 670 385 768 420 Hand wheel kg/79.5 lbs. SY8-110 13280 in-lbs/ 1500 Nm 60 seconds 50 seconds 8.2 4.8 847 514 984 576 Hand wheel kg/79.5 lbs. SY9-110 17700 in-lbs/ 2000 Nm 68 seconds 57 seconds 2.7 2.8 304 311 324 3 Hand wheel 72 kg/176.4 lbs. SY10-110 22130 in-lbs/ 2500 Nm 75 seconds 62 seconds 2.8 2.9 318 3 3 348 Hand wheel 72 kg/176.4 lbs. SY11-110 26550 in-lbs/ 3000 Nm 78 seconds 69 seconds 3.3 3.6 5 387 396 432 Hand wheel 72 kg/176.4 lbs. SY12-110 30980 in-lbs/ 00 Nm 72 seconds 60 seconds 3.7 3.8 415 422 444 456 Hand wheel 72 kg/176.4 lbs. Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. Power Supply 230 V Single Phase Model # Torque Speed 50 Hz Speed 60 Hz urrent raw urrent raw PRUP-3-T* 1400 in-lbs/ 160 Nm sec. sec. 0.2 0.2 20 20 52 52 Manual override crank 5.8 kg/12.8 lbs. PRXUP-3-T* 1400 in-lbs/ 160 Nm, 30-120 sec., 30-120 sec. 0.2 0.2 20 20 52 52 Manual override crank 5.8 kg/12.8 lbs. SY4-220 40 in-lbs/ 400 Nm 21 seconds 18 seconds 1.1 0.9 221 180 253 207 Hand wheel 22 kg/48.5 lbs. SY5-220 4430 in-lbs/ 500 Nm 29 seconds 25 seconds 1.1 0.9 216 179 253 207 Hand wheel 22 kg/48.5 lbs. SY6-220 5750 in-lbs/ 650 Nm 38 seconds 31 seconds 1.0 0.9 193 177 230 207 Hand wheel 22 kg/48.5 lbs. SY7-220 8850 in-lbs/ 1000 Nm 58 seconds 48 seconds 1.8 1.4 381 290 414 322 Hand wheel kg/79.5 lbs. SY8-220 13280 in-lbs/ 1500 Nm 59 seconds 49 seconds 1.9 1.4 428 294 437 322 Hand wheel kg/79.5 lbs. SY9-220 17700 in-lbs/ 2000 Nm 68 seconds 57 seconds 1.6 2.4 6 509 8 552 Hand wheel 72 kg/176.4 lbs. SY10-220 22130 in-lbs/ 2500 Nm 73 seconds 62 seconds 1.7 2.5 377 531 391 579 Hand wheel 72 kg/176.4 lbs. SY11-220 26550 in-lbs/ 3000 Nm 46 seconds 64 seconds 1.8 2.5 397 547 414 579 Hand wheel 72 kg/176.4 lbs. SY12-220 30980 in-lbs/ 00 Nm 74 seconds 61 seconds 1.8 2.4 409 505 414 552 Hand wheel 72 kg/176.4 lbs. V V Override eight *-200 and -250 versions have the same ratings. 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN 9

utterfly Valve ctuators Power Supply 24 V/V Single Phase Model # Torque Speed 50 Hz/60 Hz urrent raw urrent raw PRXUP-MT-T* 1400 in-lbs/160 Nm 30-120 sec. 0.9 0.9 20 20 20 20 Manual override crank 5.8 kg/12.8 lbs. PKRXUP-MT-T* 1400 in-lbs/160 Nm 30-120 sec. 2.2 2.2 52 52 55 55 Manual override crank 6.4 kg/14.1 lbs. SY4-24MT 40 in-lbs/ 400 Nm 23 seconds 11.0 11.0 254 251 264 264 Hand wheel 22 kg/48.5 lbs. SY5-24MT 4430 in-lbs/ 500 Nm 30 seconds 10.2 10.2 232 230 245 245 Hand wheel 22 kg/48.5 lbs. V V Override eight Power Supply 120 V Single Phase Model # Torque Speed 50 Hz Speed 60 Hz urrent raw urrent raw PRXUP-MT-T* 1400 in-lbs/160 Nm 30-120 sec. 30-120 sec. 0.2 0.2 18 18 23 23 Manual override crank 5.8 kg/12.8 lbs. PKRXUP-MT-T* 1400 in-lbs/160 Nm 30-120 sec. 30-120 sec. 0.3 0.3 40 40 43 43 Manual override crank 6.4 kg/14.1 lbs. SY4-120MT 40 in-lbs/ 400 Nm 16 seconds 17 seconds 2.3 2.4 258 256 276 288 Hand wheel 22 kg/48.5 lbs. SY5-120MT 4430 in-lbs/ 500 Nm 21 seconds 21 seconds 2.3 2.3 216 208 276 276 Hand wheel 22 kg/48.5 lbs. SY6-120MT 5750 in-lbs/ 650 Nm 28 seconds 29 seconds 2.2 2.2 240 2 264 264 Hand wheel 22 kg/48.5 lbs. SY7-120MT 8850 in-lbs/ 1000 Nm 41 seconds 44 seconds 1.8 1.7 198 192 216 204 Hand wheel kg/79.5 lbs. SY8-120MT 13280 in-lbs/ 1500 Nm 48 seconds 48 seconds 2.6 2.6 275 266 312 312 Hand wheel kg/79.5 lbs. SY9-120MT 17700 in-lbs/ 2000 Nm 47 seconds 47 seconds 3.6 3.4 397 382 432 408 Hand wheel 72 kg/176.4 lbs. SY10-120MT 22130 in-lbs/ 2500 Nm 52 seconds 51 seconds 4.0 4.0 450 445 480 480 Hand wheel 72 kg/176.4 lbs. SY11-120MT 26550 in-lbs/ 3000 Nm 55 seconds 56 seconds 3.1 3.0 332 318 372 0 Hand wheel 72 kg/176.4 lbs. SY12-120MT 30980 in-lbs/ 00 Nm 61 seconds 62 seconds 3.6 3.4 386 8 432 408 Hand wheel 72 kg/176.4 lbs. V V Override eight Power Supply 230 V Single Phase Model # Torque Speed 50 Hz Speed 60 Hz urrent raw urrent raw PRXUP-MT-T* 1400 in-lbs/160 Nm 30-120 sec. 30-120 sec. 0.1 0.1 20 20 52 52 Manual override crank 5.8 kg/12.8 lbs. PKRXUP-MT-T* 1400 in-lbs/160 Nm 30-120 sec. 30-120 sec. 0.2 0.2 40 40 68 68 Manual override crank 6.4 kg/14.1 lbs. SY4-230MT 40 in-lbs/ 400 Nm 16 seconds 17 seconds 1.1 1.1 222 217 253 253 Hand wheel 22 kg/48.5 lbs. SY5-230MT 4430 in-lbs/ 500 Nm 22 seconds 22 seconds 1.1 1.0 211 200 253 230 Hand wheel 22 kg/48.5 lbs. SY6-230MT 5750 in-lbs/ 650 Nm 32 seconds 32 seconds 1.1 1.1 2 232 253 253 Hand wheel 22 kg/48.5 lbs. SY7-230MT 8850 in-lbs/ 1000 Nm 44 seconds 44 seconds 0.9 0.8 167 157 207 184 Hand wheel kg/79.5 lbs. SY8-230MT 13280 in-lbs/ 1500 Nm 55 seconds 57 seconds 1.3 1.4 288 286 299 322 Hand wheel kg/79.5 lbs. SY9-230MT 17700 in-lbs/ 2000 Nm 61 seconds 61 seconds 1.1 1.1 240 233 253 253 Hand wheel 72 kg/176.4 lbs. SY10-230MT 22130 in-lbs/ 2500 Nm 72 seconds 70 seconds 1.4 1.4 277 284 322 322 Hand wheel 72 kg/176.4 lbs. SY11-230MT 26550 in-lbs/ 3000 Nm 44 seconds 48 seconds 2.0 1.9 376 3 460 437 Hand wheel 72 kg/176.4 lbs. SY12-230MT 30980 in-lbs/ 00 Nm 47 seconds 51 seconds 2.2 2.0 490 456 506 460 Hand wheel 72 kg/176.4 lbs. V V Override eight Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. *-200 and -250 versions have the same ratings. 10 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN

Interface iring etail SYx-MT, 24V, 120/230V ctuators: SYx-MT INSTLLTION NOTS UTION Notes: 1. Motor MS have been factory calibrated and should not be moved. 2. n adaption must be performed if any limit switch is adjusted. This will calibrate the beginning and end stopping points. Press the adaption button for 3 seconds and release. 3. New SY actuators must have an adaption performed before operation. P Tool Service Jack onnection ontrol Signal + ontrol Signal - K + K - Power Supply om - Power Supply Hot + daption Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. ontrol Signal + ontrol Signal - K + K - irection of Rotation 24V N - Power Supply ommon H - Power Supply Hot P Tool Service Jack daption irection of Rotation 120/230V 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN 11

Interface iring etail SYx-P L Open L lose N Power Supply (4) + Power Supply (5) ontrol Signal (6) ontrol Signal (7) Sensitivity switch se tting is position #3 for factory default. To widen deadband, select a higher number (up to 9). Sensitivity eedback (11) eedback (12) VR2 VR1 INSTLLTION NOTS UTION Notes: 1. o not change sensitivity or dip switch settings with power applied! 2. VR1 and VR2 are factory calibrated and should not be moved. 3. Motor MS have been factory calibrated and should not be moved. ip Switch Settings 8 7 6 5 4 3 2 1 O ON INPUT = 2-10 V 8 7 6 5 4 3 2 1 O ON RSPONS = IRT 8 7 6 5 4 3 2 1 O INPUT = 4-20m 8 7 6 5 4 3 2 1 O RSPONS = RVRS ON ON RNIN Potentiometer (actory Pre-set) 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 O ON O ON O ON INPUT = 1-5 V OUTPUT = 4-20m OUTPUT = 2-10 V 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 or 2-position actuators with 1k feedback option Potentiometer points 1, 2, 3 are wired to terminal blocks 8, 9, 10. hen a valve is closed: 8, 9 1k Ω 9, 10 0k Ω hen a valve is opened: 8, 9 0k Ω 9, 10 1k Ω O ON O ON O ON LOSS O SINL = LOS (irect cting) LOSS O SINL = OPN (Reverse cting) LOSS O SINL = OPN (irect cting) LOSS O SINL = LOS (Reverse cting) LOSS O SINL = STOP Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. *On modulating actuators O NOT master/ slave using optional potentiometer. or modulating actuators with 1k feedback option* Potentiometer points 1, 2, 3 are wired to terminal blocks 8, 9, 10. hen a valve is closed: 8, 9 1k Ω 9, 10 0k Ω hen a valve is opened: 8, 9 0k Ω 9, 10 1k Ω 12 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN

SY... Series Non-Spring Return ctuator UTION lectrical Travel djustment (actory Pre-set) SY-1 actory pre-set see chart below. ield adjustable if required uxiliary Switch for losed Indication LS2 LS1 uxiliary Switch for Opened Indication actory pre-set and calibrated. o not adjust - warranty voided LS2 LOS lockwise ecrease losed ngle ounter-clockwise Increase losed ngle LS1 OPN lockwise Increase Opening ngle ounter-clockwise ecrease Opening ngle UTION lectrical Travel djustment SY-2-12 actory pre-set see chart below. ield adjustable if required uxiliary Switch for losed Indication uxiliary Switch for Opened Indication Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. RNIN LS2 LS1 actory pre-set and calibrated. o not adjust - warranty voided LS2 LOS LS1 OPN lockwise ecrease losed ngle ounter-clockwise Increase losed ngle lockwise Increase Opening ngle ounter-clockwise ecrease Opening ngle Switches at left are shown with actuator fully open. 0 5 85 90 - - 0 5 85 90 - - INSTLLTION NOTS UTION Notes: 1. n adaption must be performed when the limit switches are adjusted. or the SYx-MT actuators. This will calibrate the beginning and end stopping points. Press the adaption button for 3 seconds and release. 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN 13

546_12 iring for ontrol Valves On/Off, 24V, 120/230V SY ctuator iring iagram, SY1 5-24V On/Off SY1 12-120V or 230V On/Off Hazard Identification arnings and autions appear at appropriate sections throughout this manual. Read these carefully. UTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. Indicates an action or condition that may cause irreversible damage to the actuator(s) or associated equipment. quipment damage! Power consumption and input impedance must be observed. NOTS SY1 5-24 ach actuator should be powered by a single, isolated 33 control transformer. using a common control signal input. INSTLLTION NOTS Observe class 1 and class 2 wiring restrictions. Transformer sizing = SY actuator draw X 1.25 (safety margin) (x. SY2-24 requires 3.0 x 1.25 = 3.75, 3.75 X 24 V = 90V Transformer). NOTS SY1 12-120V or 230V aution: Power Supply Voltage using a common control signal input. 33 24V / Transformer round 120V or 230V / round Line Volts Open lose 1 ommon 3 Open 4 losed onnect to #1 for fully 5 open indication 6 7 HTR - (Open Indication) - (losed Indication) ontact Rating: 5 250 V Max. SY2 5-24 N L1 H L2 Open lose 1 ommon 3 Open 4 losed onnect to #1 for fully 5 open indication 6 7 HTR - (Open Indication) - (losed Indication) ontact Rating: 5 250 V Max. SY2 12-120V or 230V Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. - (Open Indication) ontact Rating: 5 125 V Max. 3 250 V Max. - (Open Indication) ontact Rating: 5 125 V Max. 3 250 V Max. - (losed Indication) - (losed Indication) SY1-24 SY1-110 (220) SY1 ontact rrangements 14 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN

547_11 iring for ontrol Valves Proportional, 24V, 120/230V SY ctuator iring iagram, SY1-24P and SY1-110P (220P) Hazard Identification this manual. Read these carefully. UTION may result in minor or moderate injury. It may also be used to alert against unsafe practices. Indicates an action or condition that may cause irreversible damage to the actuator(s) or associated equipment. INSTLLTION NOTS 34 PPLITION NOTS round shielded wire at control panel chassis. Tape back ground at actuator. Use of feedback is optional. NOTS SY1 24P ach actuator should be powered by a single, isolated 33 control transformer. " " wiring to a common is prohibited. Terminals 4 and 6 need to be wired separately. NOTS SY1 110P (220P) aution: " " wiring to a common is prohibited. Terminals 4 and 6 need to be wired separately. 33 24V / Transformer round 120 or 230 V round Line Voltage 4 Power Supply om 5 Power Supply Hot N L1 H L2 4 Power Supply om 5 Power Supply Hot Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. ontrol signal eedback 34 6 ontrol Signal (-) 7 ontrol Signal (+) 8 9 10 11 eedback (-) 12 eedback (+) SY1-24P ontrol signal eedback 34 6 ontrol Signal (-) 7 ontrol Signal (+) 8 9 10 11 eedback (-) 12 eedback (+) SY1-110P (220P) 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN 15

547_2_11 iring for ontrol Valves Proportional, 24V, 120/230V ctuator: SY4 5-24MT SY4...12-120MT SY4...12-230MT Hazard Identification arnings and autions appear at appropriate sections throughout this manual. Read these carefully. UTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. Indicates an action or condition that may cause irreversible damage to the actuator(s) or associated equipment. quipment damage! Power consumption and input impedance must be observed. INSTLLTION NOTS Observe lass 1 and lass 2 wiring restrictions. Transformer sizing = SY actuator draw X 1.25 (safety margin) (x. SY2-24 requires 3.0 x 1.25 = 3.75, 3.75 X 24 V = 90V Transformer) 34 PPLITION NOTS round shielded wire at control panel chassis. Tape back ground at actuator. Use of feedback is optional. NOTS SY4...5-24MT ach actuator should be powered by a single, isolated 33 control transformer. Power supply om/neutral and ontrol Signal " " wiring to a common is prohibited. NOTS SY2...12-120MT (230MT) aution: Power supply voltage. P Tool Service Jack 1 2 3 ontrol Signal eedback ontrol Signal (+) ontrol Signal (-) eedback Signal (+) Y 1 U5 ddress /- ~/+ Power Supply om Power Supply Hot 24V / 33 34 eedback Signal (-) 2 1 daption 8 9 ontrol Signal eedback - (Open Indication) ontact Rating: 5 125 V Max. 3 250 V Max. 34 P ontrol Signal (+) ontrol Signal (-) eedback Signal (+) eedback Signal (-) P 2 Y 1 U5 2 1 2 P Tool Service Jack 10 Y2 Y1 SYx-24MT Power Supply om 120v (N) / 230v (L1) Power Supply Hot 120v (H) / 230v (L2) N L 1 2 3 daption ddress 8 Y1 9 Y2 SYx-120MT 10 SYx-230MT Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. - (losed Indication) SY4...5-24MT SY4...12-120MT (230MT) 16 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN

549_11 iring for ontrol Valves On/Off, 24V, 110/120/230V SY ctuator iring iagram, SY1 5-24 Multiple iring SY1 12-110 (220) Multiple iring Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. Hazard Identification arnings and autions appear at appropriate sections throughout this manual. Read these carefully. UTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. Indicates an action or condition that may cause irreversible damage to the actuator(s) or associated equipment. quipment damage! Power consumption and input impedance must be observed. Isolation relays are required in parallel applications. The reason parallel applications need isolation relays is that the motor uses two sets of windings, one for each direction. hen one is energized to turn the actuator in a specific direction a voltage is generated in the other due to the magnetic field created from the first. It s called back M. This is OK with one actuator because the voltage generated in the second winding isn t connected to anything so there is no flow; it has no magnetic effect on the motor. On parallel applications without isolation, this M voltage energizes the winding it is connected to on the other actuators in the system, the actuators are then trying to turn in both directions at once. The M voltage is always less than the supply voltage due to the resistance of the windings, so while the actuator still turns in the commanded direction, the drag from the other reduces the torque output and causes overheating. Line Voltage 24V Transformer Open lose K1 K1- K1- * * round 1 ommon 3 Open 4 losed 5 6 7 HTR - (Open Indication) - (losed Indication) ontact Rating: 5 250 V Max. SY2 5-24 round 1 ommon 3 Open 4 losed 5 6 7 HTR - (Open Indication) - (losed Indication) ontact Rating: 5 250 V Max. SY2 5-24 ctuator ctuator INSTLLTION NOTS Observe class 1 and class 2 wiring restrictions. Transformer sizing = SY actuator draw X 1.25 (safety margin) (x. SY2-24 requires 3.0 x 1.25 = 3.75, 3.75 X 24 V = 90V Transformer). NOTS aution: Power Supply Voltage. Isolation relays must be used in parallel connection of multiple actuators using a common control signal input. Should be PT. "H" (L2) cannot be connected to terminal #3 and #4 simultaneously. Required: Terminal #7 needs to be field wired to enable heater circuit. 120 or 230 V N L1 H L2 - (Open Indication) ontact Rating: 5 125 V Max. 3 250 V Max. - (losed Indication) SY1-24 Open lose K1 SY1-110 (220) K1- K1- - (Open Indication) ontact Rating: 5 125 V Max. 3 250 V Max. - (losed Indication) SY1 ontact rrangements round 1 ommon 3 Open 4 losed 5 6 7 HTR - (Open Indication) - (losed Indication) ontact Rating: 5 250 V Max. round 1 ommon 3 Open 4 losed 5 6 7 HTR SY2 12-110 (220) - (Open Indication) ctuator ctuator - (losed Indication) ontact Rating: 5 250 V Max. SY2 12-110 (220) 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN 17

550_11 iring for ontrol Valves Proportional, 24V SY ctuator iring iagram, SY1-24P Multiple iring Hazard Identification arnings and autions appear at appropriate sections throughout this manual. Read these carefully. UTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. PPLITION NOTS Recommended twisted shielded pair for control wiring. round shielded wire at control panel chassis. Tape back ground at actuator. Use of feedback is optional. Indicates an action or condition that may cause irreversible damage to the actuator(s) or associated equipment. quipment damage! Power consumption and input impedance must be observed. Isolation relays are required in parallel applications. The reason parallel applications need isolation relays is that the motor uses two sets of windings, one for each direction. hen one is energized to turn the actuator in a specific direction a voltage is generated in the other due to the magnetic field created from the first. It s called back M. This is OK with one actuator because the voltage generated in the second winding isn t connected to anything so there is no flow; it has no magnetic effect on the motor. On parallel applications without isolation, this M voltage energizes the winding it is connected to on the other actuators in the system, the actuators are then trying to turn in both directions at once. The M voltage is always less than the supply voltage due to the resistance of the windings, so while the actuator still turns in the commanded direction the drag from the other reduces the torque output and causes overheating. INSTLLTION NOTS Observe class 1 and class 2 wiring restrictions. Transformer sizing = SY actuator draw X 1.25 (safety margin) (x. SY2-24 requires 3.0 x 1.25 = 3.75, 3.75 X 24 V = 90V Transformer). NOTS SY1-24P ach actuator should be powered by a single, isolated 33 control transformer. SY1-24P notes: Power supply om/neutral and ontrol Signal " " wiring to a common is prohibited. Terminals 4 and 6 need to be wired separately otherwise irreversible damage will occur. o not change sensitivity or dip switch settings with power applied. 33 33 24V / Transformer Line Voltage 24V / Transformer Line Voltage ontrol Signal eedback () eedback () round 4 Power Supply om 5 Power Supply Hot 6 ontrol Signal (-) 7 ontrol Signal (+) 8 9 10 11 eedback (-) 12 eedback (+) SY1-24P round ctuator - (Open Indication) ontact Rating: 5 125 V Max. 3 250 V Max. - (losed Indication) ctuator 4 Power Supply om 5 Power Supply Hot 6 ontrol Signal (-) 7 ontrol Signal (+) 8 9 10 11 eedback (-) 12 eedback (+) Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. - (Open Indication) ontact Rating: 5 125 V Max. 3 250 V Max. - (losed Indication) SY1-24P 18 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN

550_2_11 iring for ontrol Valves Proportional, Multiple iring, 24V ctuators: SY2...5-24MT Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. Hazard Identification arnings and autions appear at appropriate sections throughout this manual. Read these carefully. UTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. Indicates an action or condition that may cause irreversible damage to the actuator(s) or associated equipment. quipment damage! Power consumption and input impedance must be observed. Isolation relays are required in parallel applications. The reason parallel applications need isolation relays is that the motor uses two sets of windings, one for each direction. hen one is energized to turn the actuator in a specific direction a voltage is generated in the other due to the magnetic field created from the first. It s called back M. This is OK with one actuator because the voltage generated in the second winding isn t connected to anything so there is no flow; it has no magnetic effect on the motor. On parallel applications without isolation, this M voltage energizes the winding it is connected to on the other actuators in the system, the actuators are then trying to turn in both directions at once. The M voltage is always less than the supply voltage due to the resistance of the windings, so while the actuator still turns in the commanded direction, the drag from the other reduces the torque output and causes overheating. - (Open Indication) - (losed Indication) ontact Rating: 5 250 V Max. SY2 5-24MT ontrol Signal eedback ontrol Signal (+) ontrol Signal (-) eedback Signal (+) eedback Signal (-) ontrol Signal (+) ontrol Signal (-) P INSTLLTION NOTS Observe class 1 and class 2 wiring restrictions. Transformer sizing = SY actuator draw X 1.25 (safety margin) (x. SY2-24 requires 3.0 x 1.25 = 3.75, 3.75 X 24 V = 90V Transformer). 33 ctuator Y 1 U5 2 1 2 ctuator Y 1 NOTS SY2...5-24MT ach actuator should be powered by a single, isolated control transformer. PPLITION NOTS Recommended twisted shielded pair for control wiring. round shielded wire at control panel chassis. Tape back ground at actuator. Use of feedback is optional. ddress daption Y1 Y2 P Tool Service Jack P Tool Service Jack SYx-24MT 1 2 3 ~/+ 8 9 10 1 2 3 /- /- ~/+ Power Supply om Power Supply Hot Power Supply om Power Supply Hot 24V / 24V / 33 eedback eedback Signal (+) U5 ddress 33 eedback Signal (-) 2 1 daption 8 9 2 Y1 Y2 SYx-24MT 10 P 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN 19

552_1_11 Proportional, 110/220V, 120/230V ctuators: SY1-110P SY1-220P Hazard Identification 120 or 230 V round arnings and autions appear at appropriate N L1 4 Power Supply om sections throughout this manual. Read these carefully. H L2 5 Power Supply Hot UTION 6 ontrol Signal (-) Indicates a potentially hazardous situation which, if 7 ontrol Signal (+) not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. 8 9 Indicates an action or condition that may cause irreversible damage to the actuator(s) or associated equipment. quipment damage! Power consumption and input impedance must be observed. INSTLLTION NOTS Observe class 1 and class 2 wiring restrictions. eedback () ctuator 10 11 eedback (-) 12 eedback (+) - (Open Indication) ontact Rating: 5 125 V Max. 3 250 V Max. - (losed Indication) SY1-110P (220P) PPLITION NOTS round ctuator Recommended twisted shielded pair for control wiring. round shielded wire at control panel chassis. Tape back ground at actuator. Use of feedback is optional. NOTS SY1-110P (220P) aution: Power supply voltage. power applied. ontrol Signal eedback () 4 Power Supply om 5 Power Supply Hot 6 ontrol Signal (-) 7 ontrol Signal (+) 8 9 10 11 eedback (-) 12 eedback (+) - (Open Indication) ontact Rating: 5 125 V Max. 3 250 V Max. - (losed Indication) SY1-110P (220P) Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. 20 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN

552_2 iring for ontrol Valves Proportional, Multiple iring, 120/230V ctuators: SY2...12-120MT SY2...12-230MT Hazard Identification arnings and autions appear at appropriate sections throughout this manual. Read these carefully. UTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. Indicates an action or condition that may cause irreversible damage to the actuator(s) or associated equipment. quipment damage! Power consumption and input impedance must be observed. Isolation relays are required in parallel applications. The reason parallel applications need isolation relays is that the motor uses two sets of windings, one for each direction. hen one is energized to turn the actuator in a specific direction a voltage is generated in the other due to the magnetic field created from the first. It s called back M. This is OK with one actuator because the voltage generated in the second winding isn t connected to anything so there is no flow; it has no magnetic effect on the motor. On parallel applications without isolation, this M voltage energizes the winding it is connected to on the other actuators in the system, the actuators are then trying to turn in both directions at once. The M voltage is always less than the supply voltage due to the resistance of the windings, so while the actuator still turns in the commanded direction, the drag from the other reduces the torque output and causes overheating. ontrol Signal (+) INSTLLTION NOTS Observe class 1 and class 2 wiring restrictions. PPLITION NOTS Recommended twisted shielded pair for control wiring. round shielded wire at control panel chassis. Tape back ground at actuator. Use of feedback is optional. NOTS SY2...12-120MT (230MT) aution: Power supply voltage. Y P Tool Service Jack N L Power Supply om 120 V (N) / 230 V (L1) Power Supply Hot 120 V (H) / 230 V (L2) 1 ontrol Signal (-) 1 2 Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. - (Open Indication) - (losed Indication) ontact Rating: 5 250 V Max. SY2...12-120MT SY2...12-230MT ontrol Signal eedback eedback eedback Signal (+) eedback Signal (-) P ontrol Signal (+) ontrol Signal (-) eedback Signal (+) eedback Signal (-) U5 2 1 2 ctuator Y 1 U5 2 1 2 P Tool Service Jack daption SYx-120MT SYx-230MT daption N L 3 ddress 8 Y1 9 Y2 10 Power Supply om 120 V (N) / 230 V (L1) Power Supply Hot 120 V (H) / 230 V (L2) 1 2 3 ddress 8 P ctuator SYx-120MT SYx-230MT Y1 Y2 9 10 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN 21

Installation Recommendations VI Series utterfly Valves Maintenance Instructions Safety Precautions efore removing the valve from the line or loosening any bolts, it is important to verify the following conditions: 1. e sure the line is depressurized and drained. 2. e sure of the pipeline media. Proper care should be taken for protection against toxic and/or flammable fluids. 3. Never remove the valve without an Operator (Manual or utomatic) already attached to the valve shaft. 4. Never remove the Operator from the valve while the valve is in the pipeline under pressure. 5. lways be sure that the disc is cracked approximately 5 off of the closed position before removing the valve. Installation onsult the Victaulic I-100 field instructional handbook for product installation of the VI series butterfly valves. eneral Maintenance The following periodic preventative maintenance practices are recommended for all utterfly Valves. 1. Operate the valve from full open to full closed to assure operability. 2. heck flange bolting, actuator mounts and hangers for evidence of loosening and correct as needed. 3. Inspect the valve and surrounding area for previous or existing leakage at flange faces or shaft connections. 4. heck piping and/or wiring to actuators and related equipment for looseness and correct as needed. 5. If not in use, exercise the butterfly valve (full open and close) at least once a month. Tech.oc - 03/16 - Subject to change. elimo ircontrols (US), Inc. 22 800-543-9038 US 866-805-7089 N 203-791-8396 LTIN MRI / RIN