OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Similar documents
OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Pressure transmitter For general industrial applications Model A-10

High-quality pressure transmitter For general industrial applications Model S-10

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10

OEM pressure transmitter For mobile working machines Model MH-3

High-quality pressure transmitter For general industrial applications Model S-20

Flush pressure transmitter For viscous and solids-containing media Model S-11

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Electronic temperature switch with display Model TSD-30

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For water and wastewater Model LW-1

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Submersible pressure sensor For superior applications Model LF-1

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Mechatronic pressure measurement. Applications. Special features. Description

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Resistance thermometer Model TR31, miniature design

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Pressure transmitter For sanitary applications Model SA-11

Miniature resistance thermometer Model TR33, thread-mounted

Float switch For industrial applications, plastic version Model RLS-2000

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Pressure Transmitter SIL

Indicator for panel mounting Model

Resistance thermometer Model TR30, compact design

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Field indicator for current loops with HART communication Models DIH50, DIH52

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Resistance thermometer Model TR30, compact design

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Field indicator for current loops with HART communication Models DIH50, DIH52

Digital indicator for panel mounting With multi-function input Model DI25

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

ED701 General Industry Pressure Transmitter

Materials (other materials see WIKA diaphragm seal program) Model S-10

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

High-precision process calibrator Model CED7000

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

PI2794. Flush pressure sensor with display. 1 alphanumeric display 4-digit 2 status LEDs 3 programming button. Made in Germany

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Pressure transmitter AKS 32 and AKS 33

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

ECT Applications. Features

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)

Air flow meter For ventilation and air-conditioning Model A2G-25

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Resistance Thermometers Model Series TR7X0, Sheathed Design

Electronic Pressure Switch Type MEP

NAT Applications. Features

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

U5300 Industrial Pressure Transducer

Electronic Temperature Transmitters

XXXX e. X d.. X X X a

NAT Applications. Features

Screw-in resistance thermometers with plug connector

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

M5200 Industrial Pressure Transducer

Rotary Measurement Technology Incremental Encoders

In-line resistance thermometer Model TR25

Heavy Duty Pressure Transducers

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Your Global Automation Partner. PT2000 Pressure Transmitter

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Industrial Pressure Transmitter

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

XXXX e. X d.. X X X a

Analogue Temperature Transmitter

Hand-held temperature calibrator Model CEP3000

Digital inductive conductivity transmitter

NOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900

INDUSTRIAL PRESSURE TRANSMITTER

ph or ORP Transmitter

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

Digital flow ELEMENT transmitter for continuous flow measurement

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Transcription:

Pressure OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 for further approvals see page 11 Applications Hydraulics and pneumatics Pumps and compressors Machine building Building services Special features Measuring ranges from 0 6 to 0 600 bar Non-linearity 0.5 % Standard industrial signals Electrical connection: Angular connector form A and C, circular connector M12 x 1, Metri-Pack series 150, cable outlet 2 m unshielded or shielded Many internationally customary process connections Pressure sensor model O-10 (T) Description The model O-10 pressure sensor has been developed for a wide variety of industrial applications. The large range of process and electrical connections as well as all commonly used pressure ranges and output signals set the model O-10 apart. For applications in which water is used as a medium we recommend a 5-fold overload safety in combination with a condensation-tight case. The model O-10 has been designed specifically for the demands of the global market. The pressure sensor offers international units and the corresponding approvals for the North American and Russian markets. It goes without saying that the model O-10 can be delivered with customer-specific labelling (e.g. company logo and instrument designation). Due to its specifications, its features and its price, the pressure sensor is ideally suited to OEM applications, with an annual quantity requirement of more than 1,000 units of each article number. Accordingly, the minimum order quantity is 50 units per article number. WIKA data sheet PE 81.65 03/2018 Page 1 of 12 Data sheets showing similar products: Pressure sensor for general industrial applications; model A-10; see data sheet PE 81.60

Versions Model O-10 (T) Standard version Model O-10 (5) With 5-fold overload safety and condensation-tight case For applications with water as a medium a 5-fold overpressure safety for protection against water hammer effects and a condensation-tight case is recommended. Measuring ranges, model O-10 (T) Gauge pressure bar 0... 6 1) 2) 0... 10 1) 2) 0... 16 0... 25 0... 40 0... 60 0... 100 0... 160 0... 250 0... 400 0... 600 psi 0... 100 1) 2) 0... 160 0... 200 0... 250 0... 300 0... 400 0... 500 0... 600 0... 750 0... 800 0... 1,000 0... 1,500 0... 2,000 0... 3,000 0... 4,000 0... 5,000 0... 6,000 0... 7,500 0... 8,000 Vacuum and +/- measuring range bar -1... +5 2) -1... +9 2) -1... +15-1... +24-1... +39-1... +59 psi -30 inhg... +100 2) -30 inhg... +160-30 inhg... +200-30 inhg... +300-30 inhg... +500 1) Measuring deviation of the zero signal ±0.7 % of span 2) Non-linearity ±0.6 % of span BFSL The given measuring ranges are also available in kg/cm 2, kpa and MPa. Other measuring ranges on request. Overload safety 2 times (3 times on request) Vacuum tightness Yes Measuring ranges, model O-10 (5) Gauge pressure bar 0... 6 0... 10 0... 16 0... 25 0... 40 psi 0... 100 0... 200 0... 500 Vacuum and +/- measuring range bar -1... +5 psi -30 inhg... +100 Other measuring ranges on request Overload safety 5 times Vacuum tightness Yes WIKA data sheet PE 81.65 03/2018 Page 2 of 12

Output signals, model O-10 (T) Signal type Signal Current (2-wire) 4... 20 ma Voltage (3-wire) DC 0.5... 4.5 V DC 0... 5 V DC 1... 5 V DC 0... 10 V Ratiometric (3-wire) DC 0.5... 4.5 V Other output signals on request Load in Ω Current output (2-wire): Voltage output (3-wire): Ratiometric output signal (3-wire): (power supply - 8 V) / 0.02 A > maximum output signal / 1 ma > 4.5 kω Output signals, model O-10 (5) Signal type Signal Current (2-wire) 4... 20 ma Voltage (3-wire) DC 0.5... 4.5 V DC 1... 5 V Ratiometric (3-wire) DC 0.5... 4.5 V Other output signals on request Load in Ω Current output (2-wire): Voltage output (3-wire): Ratiometric output signal (3-wire): (power supply - 8 V) / 0.02 A > maximum output signal / 1 ma > 4.5 kω WIKA data sheet PE 81.65 03/2018 Page 3 of 12

Voltage supply Power supply The power supply depends on the selected output signal. 4... 20 ma: DC 8... 30 V DC 0.5... 4.5 V: DC 8... 30 V DC 0... 5 V: DC 8... 30 V DC 1... 5 V: DC 8... 30 V DC 0... 10 V: DC 14... 30 V DC 0.5... 4.5 V (ratiometric): DC 4.5... 5 V The power supply for the pressure sensor must be made via an energy-limited electric circuit in accordance with section 9.4 of UL/EN/IEC 61010-1 or an LPS to UL/EN/IEC 60950-1 or class 2 in accordance with UL1310/UL1585 (NEC or CEC). The power supply must be suitable for operation above 2,000 m should the pressure sensor be used at this altitude. Total current consumption Current output: Corresponds to the value of the output signal current (4... 20 ma), maximum 25 ma Voltage output: 5 ma Reference conditions (per IEC 61298-1) Temperature 15... 25 C (59... 77 F) Atmospheric pressure 860... 1,060 mbar (12.5... 15.4 psi) Humidity 45... 75 % gauge Power supply Current output: Voltage output: Ratiometric output signal: DC 14 V DC 24 V DC 5 V Nominal position Calibrated in vertical mounting position with process connection facing downwards. Time response Settling time < 2 ms WIKA data sheet PE 81.65 03/2018 Page 4 of 12

Accuracy specifications, model O-10 (T) Non-linearity (per IEC 61298-2) ±0.5 % of span BFSL A different non-linearity applies to some measuring ranges, see Measuring ranges O-10 (T). Measuring deviation of the zero signal ±0.5 % of span A different measuring deviation applies to some measuring ranges, see Measuring ranges model O-10 (T). Accuracy at reference conditions ±1.2 % of span Temperature error at 0... 80 C (32... 176 F) ±1.5 % of span Long-term stability ±0.3 % of span/year Accuracy specifications, model O-10 (5) Non-linearity (per IEC 61298-2) ±0.5 % of span BFSL Measuring deviation of the zero signal ±1 % of span Accuracy at reference conditions ±2.0 % of span Temperature error at 0... 80 C (32... 176 F) Mean temperature coefficient of zero point Typical: 0.3 % of span/10 K Maximum: 0.6 % of span/10 K Mean temperature coefficient of span ±0.1 % of span/10 K Long-term drift ±0.2 % of span/year WIKA data sheet PE 81.65 03/2018 Page 5 of 12

Operating conditions, model O-10 (T) Ingress protection (per IEC 60529) For ingress protection see Electrical connections, model O-10 (T) The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress protection. Vibration resistance (per IEC 60068-2-6) 20 g (20... 2,000 Hz, 120 min.) Shock resistance (per IEC 60068-2-27) 40 g (6 ms), mechanical shock Service life 10 million load cycles Free-fall test Resistant to an impact onto concrete from 1 m Permissible temperatures Medium: -30... +100 C (-22... 212 F) Ambient: -30... +100 C (-22... 212 F) Storage: -30... +100 C (-22... 212 F) Operating conditions, model O-10 (5) Ingress protection (per IEC 60529) For ingress protection see Electrical connections, model O-10 (5) The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress protection. Vibration resistance (per IEC 60068-2-6) 20 g (20... 2,000 Hz, 120 min) Shock resistance (per IEC 60068-2-27) 40 g (6 ms), mechanical shock Service life 10 million load cycles Free-fall test Resistant to an impact onto concrete from 1 m Permissible temperatures Medium: -40... +100 C (-40... 212 F) Ambient: -25... +80 C (-13... 176 F) Storage: -25... +80 C (-13... 176 F) Other temperature ranges on request WIKA data sheet PE 81.65 03/2018 Page 6 of 12

Process connections Standard Thread size EN 837 G ⅛ B 2) G ¼ B G ¼ female G ⅜ B 1) 3) 4) DIN 3852-E G ¼ A M14 x 1.5 3) ANSI/ASME B1.20.1 ⅛ NPT 2) ¼ NPT 1) ¼ NPT female 1) 3) SAE J514 E 7/16-20 UNF-2A O-ring BOSS 9/16-18 UNF-2A O-ring BOSS 3) 1) Optional: Pressure port with a diameter of 6 mm / 0.6 mm / 0.3 mm on request. 2) Maximum measuring range from 0... 400 bar. 3) Minimum permissible medium temperature -30 C (-22 F), also for model O-10 (5) 4) Maximum overload safety 600 bar All process connections are available, as standard, with a pressure port of diameter 3.5 mm. Sealings Process connection per Standard Option DIN 3852-E NBR 1) FPM/FKM 2) SAE J514 E FPM/FKM 2) - 1) Minimum permissible medium and ambient temperature -30 C (-22 F) 2) Minimum permissible medium and ambient temperature -15 C (5 F) The sealings listed under Standard are included in the delivery. Materials Non-wetted parts Stainless steel 316L PBT GF 30 Cable material (cable outlet) PVC Wetted parts Stainless steel 316L 13-8 PH For sealing materials see Process connections Oil and grease free versions are available on request. WIKA data sheet PE 81.65 03/2018 Page 7 of 12

Electrical connections, model O-10 (T) Electrical connection Ingress protection Wire crosssection Cable diameter Angular connector DIN 175301-803 A IP65 - - - Angular connector DIN 175301-803 C IP65 - - - Circular connector M12 x 1 (4-pin) IP67 - - - Delphi connector Metri-Pack series 150 (3-pin) 1) IP67 - - - Cable lengths Cable outlet, unshielded 2) IP67 0.14 mm 2 3.4 mm 2 m, 5 m Cable outlet, shielded IP67 0.14 mm 2 4.3 mm 2 m, 5 m 1) for model O-10 (T) only possible from measuring range 0... 60 bar 2) to max. 80 C (176 F) permissible The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the appropriate ingress protection. Mating connectors are not included in the delivery, but they are available as accessories. Other connections on request. Short-circuit resistance S+ vs. 0V Reverse polarity protection UB vs. 0V Overvoltage protection DC 36 V Insulation voltage DC 750 V Electrical connections, model O-10 (5) Electrical connection Ingress protection Wire crosssection Cable diameter Circular connector M12 x 1 (4-pin) IP65 - - - Delphi connector Metri-Pack series 150 (3-pin) 1) IP67 - - - Cable lengths Cable outlet, unshielded 1) IP67 0.14 mm 2 3.4 mm 2 m, 5 m 1) to max. 80 C (176 F) permissible The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the appropriate ingress protection. Mating connectors are not included in the delivery, but they are available as accessories. Short-circuit resistance S+ vs. 0V Reverse polarity protection UB vs. 0V Overvoltage protection DC 36 V Insulation voltage DC 750 V WIKA data sheet PE 81.65 03/2018 Page 8 of 12

Connection diagrams 1) 3) Angular connector DIN 175301-803 A 2-wire UB 1 1 0V 2 2 S+ - 3 3-wire 1) 3) Angular connector DIN 175301-803 C 2-wire UB 1 1 0V 2 2 S+ - 3 3-wire 1) 2) 3) Circular connector M12 x 1 2-wire 3-wire Delphi connector Metri-Pack series 150 (3-pin) 1) 2) 3) 2-wire 3-wire UB 1 1 0V 3 3 S+ - 4 UB B B 0V A A S+ - C 1) 2) 3) Cable outlet, unshielded 1) 3) Cable outlet, shielded 2-wire 3-wire 2-wire 3-wire UB brown (BN) brown (BN) 0V green (GN) green (GN) S+ - white (WH) UB brown (BN) brown (BN) 0V blue (BU) blue (BU) S+ - black (BK) 1) Applies to model O-10 (T) 2) Applies to model O-10 (5) 3) Version with connected shield on request Legend UB Positive power supply terminal 0V Negative power supply terminal S+ Positive output terminal Dimensions in mm Angular connector DIN 175301-803 A Angular connector DIN 175301-803 C Circular connector M12 x 1 Weight: approx. 80 g Weight: approx. 80 g Weight: approx. 80 g WIKA data sheet PE 81.65 03/2018 Page 9 of 12

Delphi connector Metri-Pack series 150 with cable outlet Weight: approx. 80 g Weight: approx. 80 g G L1 G ¼ A DIN 3852-E 14 M14 x 1.5 DIN 3852-E 14 G L1 G ¼ B EN 837 13 G ⅜ B EN 837 16 G L1 9/16-18 UNF BOSS 13 7/16-20 UNF BOSS 12 G L1 G ⅛ B EN 837 10 G L1 L2 L3 D1 G ¼ 17 13 10 Ø 19 G L1 ⅛ NPT 10 ¼ NPT 13 G L1 L2 D1 ¼ NPT 17 14 Ø 19 For information on tapped holes and welding sockets, see Technical information IN 00.14 at www.wika.com. WIKA data sheet PE 81.65 03/2018 Page 10 of 12

Approvals Logo Description Country EU declaration of conformity EMC directive Pressure equipment directive RoHS directive UL (option) Safety (e.g. electr. safety, overpressure,...) EAC EMC directive GOST Metrology, measurement technology KazInMetr Metrology, measurement technology UkrSEPRO Metrology, measurement technology - CRN Safety (e.g. electr. safety, overpressure,...) European Union USA and Canada Eurasian Economic Community Russia Kazakhstan Ukraine Canada Manufacturer s information and certificates Logo Description - China RoHS directive - MTTF: > 100 years Approvals and certificates, see website Accessories and spare parts Mating connector Angular connector DIN 175301-803 A Order number without cable with 2 m cable with 5 m cable with cable gland, metric 11427567 11225793 11250186 with cable gland, conduit 11022485 - - Angular connector DIN 175301-803 C 1439081 11225823 11250194 Circular connector M12 x 1 (4-pin) straight 2421262 11250780 11250259 angled 2421270 11250798 11250232 Sealings for mating connectors Order number Angular connector DIN 175301-803 A 1576240 Angular connector DIN 175301-803 C 11169479 Only use the accessories and spare parts listed above, otherwise it could lead to the loss of the approval. WIKA data sheet PE 81.65 03/2018 Page 11 of 12

Ordering information Model / Measuring range / Output signal / Process connection / Electrical connection 09/2011 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 03/2018 EN WIKA data sheet PE 81.65 03/2018 Page 12 of 12 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de