Power Electronics Laboratory

Similar documents
Power Electronics Laboratory. THE UNIVERSITY OF NEW SOUTH WALES School of Electrical Engineering & Telecommunications

Chapter 2 Review of the PWM Control Circuits for Power Converters

Switch-Mode DC-AC Converters

Lecture 8 - Effect of source inductance on rectifier operation

Experiment 1. Speed control of a DC motor with an inner current loop

XIII International PhD Workshop OWD 2011, October Single-Stage DC-AC Converter Based On Two DC-DC Converters

Controller Design for Cuk Converter Using Model Order Reduction

16 DESEMBER AC to AC VOLTAGE CONVERTERS

INSTITUTE OF AERONAUTICAL ENGINEERING

Study of 1-phase AC to DC controlled converter (both fully controlled And half controlled)

Digital Load Share Controller Design of Paralleled Phase-Shifted Full-Bridge Converters Referencing the Highest Current

Multiple Input DC-DC Converters with Input Boost Stages

Describing Function Analysis of the Voltage Source Resonant Inverter with Pulse Amplitude Modulation

High Performance Control of a Single-Phase Shunt Active Filter

Experiment 2 IM drive with slip power recovery

Elimination of Harmonics and Dc Voltage Fluctuations Due to Non Linear Loads using Hysteresis Controlled Active Power Filter

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

Double Closed-loop Control System Design of PMSM Based on DSP MoupengTao1, a,songjianguo2, b, SongQiang3, c

UNIT IV CONTROLLER TUNING:

Minimization of EMC Filter for Interconnection Inverter by High Switching Frequency

R8CB05BO 10-PIN Green-Mode PFC/PWM Combo CONTROLLER

Hybrid Posicast Controller for a DC-DC Buck Converter

RF Microelectronics. Hanyang University. Oscillator. Changsik Yoo. Div. Electrical and Computer Eng. Hanyang University.

Improvement of Power Factor and Harmonic Reduction with VSC for HVDC System

SSM2040 Filter Analysis Part 1 - Ryan Williams

Investigating Converter Options for Automotive Grade Permanent Magnet Sychronous Generators

Research on a Low-Harmonic Nearest Level Modulation Method for Modular Multilevel Converters Pengfei Hu1, a, Xi Wang1, Lun Tang1,

Diode Rectifiers EE

Wireless Event-driven Networked Predictive Control Over Internet

Experiment 4: Three-Phase DC-AC Inverter

Half and Full-Bridge Modular Multilevel Converter Models for Simulations of Full-Scale HVDC Links and Multi-terminal DC grids

Experiment No. 2 Half Wave Rectifier using RC-Triggering

Diodes This week, we look at switching diodes, LEDs, and diode rectification. Be sure to bring a flash drive for recording oscilloscope traces.

Bidirectional step-up/step-down DC-DC converter with magnetically coupled coils

CM6805(A;B;C)/CM6806(A;B;C) (ABC0401A03A/03C/05A ; ABC0401A06A/01B) 10-PIN Green-Mode PFC/PWM Combo CONTROLLER for High Density AC Adapter

2013 Texas Instruments Motor Control Training Series. -V th. InstaSPIN Training

Principal Component Analysis-Based Compensation for Measurement Errors Due to Mechanical Misalignments in PCB Testing

Class DE Inverters and Rectifiers for DC-DC Conversion

Experiment #2 Half Wave Rectifier

EXPERIMENT 5 : THE DIODE

SINGLE PHASE CURRENT SOURCE INVERTER (C.S.I)

Experiment No. 1 Half Wave Rectifier using R-Triggering

DESIGN AND IMPLEMENTATION OF FULL BRIDGE MODULAR DC-DC CONVERTER FOR SOLAR CONVERSION SYSTEMS

Carrier-based Discontinuous PWM Modulation for Current Source Converters

Extension of the Nearest-Three Virtual-Space-Vector PWM to the Four-Level Diode-Clamped dc-ac Converter

CM6807(A;B;C) 10-PIN Green-Mode PFC/PWM Combo CONTROLLER for High Density AC Adapter

CHAPTER 3 DIODES. NTUEE Electronics L. H. Lu 3 1

Keywords Electric vehicle, Dynamic wireless power transfer, Efficiency maximization, Power control, Secondary-side control

CM6805(A;B)/CM6806A 10-PIN Green-Mode PFC/PWM Combo CONTROLLER for High Density AC Adapter

A Four Level Inverter Based Drive With a Passive Front End.

Week 8 AM Modulation and the AM Receiver

The use of power DC-DC converters and gyrator structures for energy processing in photovoltaic solar facilities 功率 DC-DC 转换器和回转器结构用于光伏太阳能设施中的能源加工

Lab 2: Linear and Nonlinear Circuit Elements and Networks

Experiment 1: Instrument Familiarization (8/28/06)

Control Scheme for Wide-Bandgap Motor Inverters with an Observer-Based Active Damped Sine Wave Filter

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

Dynamics and Control of Three-Phase Four-Leg Inverter

CHAPTER 3 APPLICATION OF THE CIRCUIT MODEL FOR PHOTOVOLTAIC ENERGY CONVERSION SYSTEM

ON-LINE PARAMETER ESTIMATION AND ADAPTIVE CONTROL OF PERMANENT MAGNET SYNCHRONOUS MACHINES. A Dissertation. Presented to

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

FAMILIARISATION WITH P.E. COMPONENTS

A Single-stage Three-phase DC/AC Inverter Based on Cuk Converter for PV Application

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

2.35 Tuning PID Controllers

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

A Single-phase Current Source PV Inverter with Power Decoupling Capability using an Active Buffer

Lab #2: Electrical Measurements II AC Circuits and Capacitors, Inductors, Oscillators and Filters

Experiment 3. Performance of an induction motor drive under V/f and rotor flux oriented controllers.

Experiment DC-DC converter

Clocking Techniques (II)

AC LAB ECE-D ecestudy.wordpress.com

Using Chaos to Detect IIR and FIR Filters

Experiment 1: Instrument Familiarization

Assuming continuous conduction, the circuit has two topologies switch closed, and switch open. These are shown in Figures 2a and 2b. L i C.

Electronic Circuits Laboratory EE462G Lab #4. DC Power Supply Circuits Using Diodes

Sample Exam Solution

Department of Electrical & Computer Engineering Technology. EET 3086C Circuit Analysis Laboratory Experiments. Masood Ejaz

A Single-stage Three-phase DC/AC Inverter Based on Cuk Converter for PV Application

A Circuit Level Fault Model for Resistive Shorts of MOS Gate Oxide

EXPERIMENT 5 : DIODES AND RECTIFICATION

ENG 100 Lab #2 Passive First-Order Filter Circuits

Wave-Induced Fluctuations in Underwater Light Field: Analysis of Data from RaDyO Experiments

Suppression of Short-circuit Current in Halt Sequence to StopTwo-level Inverter connected to PMSM during Regeneration Mode

A new method of converter transformer protection without commutation failure

VTU NOTES QUESTION PAPERS NEWS RESULTS FORUMS TESTING OF DIODE CLIPPING CIRCUITS

Dynamic Wireless Power Transfer System for Electric Vehicles to Simplify Ground Facilities - Real-time Power Control and Efficiency Maximization -

2 Dept. of Electrical and Electronic Engineering ( ) = d

LIST OF EXPERIMENTS. Sl. No. NAME OF THE EXPERIMENT Page No.

COVERTER FOR LED LIGHTING APPLICATIONS

Modeling, Simulation and Development of Supervision/Control System for Hybrid Wind Diesel System Supplying an Isolated Load

EE 171. MOS Transistors (Chapter 5) University of California, Santa Cruz May 1, 2007

Resonance in Circuits

SECONDARY TRANSMISSION POWER OF COGNITIVE RADIOS FOR DYNAMIC SPECTRUM ACCESS

The Nottingham eprints service makes this work by researchers of the University of Nottingham available open access under the following conditions.

Testing, Characterization, and Modeling of SiC Diodes for Transportation Applications

Universities of Leeds, Sheffield and York

Wavelet Transform Based Relay Algorithm for the Detection of Stochastic High Impedance Faults

Experiment 1.A. Working with Lab Equipment. ECEN 2270 Electronics Design Laboratory 1

Dev Bhoomi Institute Of Technology Department of Electronics and Communication Engineering PRACTICAL INSTRUCTION SHEET

Jawaharlal Nehru Engineering College

Transcription:

THE UNERSTY OF NEW SOUTH WALES School of Electrical Engineering & Telecommunications ELEC4614 Experiment : C-C Step-up (Boost) Converter 1.0 Objectives This experiment introuces you to a step-up C-C converter circuits. These are foun in many power supplies where a C supply at a voltage which is higher than the available C supply is require. Operation an steay-state characteristics of the step-up (boost) converter circuit will be stuie experimentally..0 Backgroun The boost converter circuit is shown in figure 1(a) in which the switch T is operate from a pulse-with moulator operating at a carrier frequency f s. The switch T has a uty cycle which ranges from 0 to 1. Figure 1(b) inicates relevant waveforms of the circuit when the switch T is turne ON an OFF at frequency f s, with a uty cycle. i i L i + v L + o i c C T o R (Loa) Figure 1(a) v L - o max i L i L i c - o R T T Figure 1(b) Experiment C-C Boost Converter 1 F. Rahman/March 009

We will assume that all the evices an components of the circuit are ieal, the inuctor current is continuous (always positive) an the output voltage is hel constant at o by the large output capacitor uring the switching intervals. Uner these circumstances the inuctor voltage v L, an inuctor an capacitor currents i L an i C, respectively, are as inicate in figure 1(b). The following equations then hol for the boost converter. o 1..(1) max.() (1 ) R Lf s min..(3) (1 ) R Lf s ( 1 ) R.(4) L, average where o = output C voltage, = supply C voltage, L = inuctance of the inuctor, H R = Loa resistance,. o o o ; ; an o o.(5) R 1 For a given switching frequency, the minimum inuctance L min for continuous conuction is given by, Lmin ( 1 ) R f s (6) The output voltage ripple across the filter capacitance C is given by o o RCf s.(7) 3.0 Switching losses Losses in the evices ue to overlap of the voltage an current transients at turn off an turn on affect the efficiency of the converter. The switching frequency f s is carefully selecte to avoi these losses becoming significant. f s also affects the physical sizes of the inuctor an capacitor. Experiment C-C Boost Converter F. Rahman/Feb, 011

4.0 iscontinuous conuction The relationship between the output voltage o an, although simple when the inuctor current is continuous uring the whole of switching perio, it is very steep when approaches 1. The ynamics of this converter are also not suitable for operation in continuous conuction moe. For the iscontinuous conuction moe, it can be shown that 1 o 1 R 1 Lf s.(8) Although this is a non-linear function, nevertheless, iscontinuous conuction moe is the preferre moe of operation of a boost converter. 4. Equipment 1 power GBT switch 1 3 phase ioe brige rectifier moule 1 L-C smoothing filter for the C supply 1 50 loa resistor for the boost converter 1 47-35 H inuctance boar for boost converter 1 four-channel oscilloscope 1 C voltmeter an ammeter moules solate transucer boars with 1/1A an 1/ sensors PC with SP boar an interface car 5. Experiment Familiarise yourself with the experimental set-up, especially the GBT, the rectifier ioe brige, the input C filter, the buck inuctor L, the buck ioe, the output filter capacitor C, an the loa resistor. The inuctor boar has inuctors in the range of -110 H which are connecte to taps. A SP boar resient in a PC generates the PWM switching pulses with which to turn the buck switch ON an OFF. The frequency of switching can be change only by running the appropriate Buck Converter for x khz programs from the esktop where x stans for the switching frequency. For each of these programs, the appropriate operator interface must also be run from the menu. The uty cycle for each of these switching frequencies can be selecte by a slier on the PC monitor. The C supply to the buck converter is obtaine from an AC supply via an auto-transformer (variac), a rectifier ioe brige followe by an LC filter. These are locate on the left-han sie of the equipment panel. For the whole of this experiment, must be set to 50. When the converter uty cycle or loa increases, will rop because of voltage rop in the variac. For each setting of or loa, you will nee to ajust the variac so that is always 50. PRECAUTONS!! 1. The experiment is pre-wire on the equipment panel. o not attempt to alter any connection of the power circuit while the C supply is on. The only alterations you will nee to make to the power circuit is the selection of tapings of the buck inuctor (using the blue wire) an connection/isconnection of the loa (using the re wire). Make sure that all power connections (screwe terminal blocks) are firm (tight) before the C supply is switche on. Any intermittent connection in any part of the circuit will estroy the GBT. Experiment C-C Boost Converter 3 F. Rahman/Feb, 011

. Also, make sure to ajust the variac to zero before you change the boost inuctor taps. You must not manually isconnect the boost inuctor while it still carrying current. Goals: n this experiment, you will run the boost converter with switching frequencies f s = 5, 10 an 0kHz; you will select boost inuctance L = 47, 141 an 35µH for each of these frequencies; you will vary the uty cycle from 0.1 to 0.9 in steps of 0. for each of these combinations, Finally you will take frequency response test ata by varying sinusoially, from 100Hz to 4kHz while the converter operates with f s = 0kHz an L = 141µH. ata obtaine from these tests will allow you unerstan the roles of L an f s on the continuous an iscontinuous moes of operation of the converter, an its control characteristics. 5.1 The power circuit for the boost converter is shown in figure. Before switching the C supply to the converter ON, run the SP program Boost Converter - 5kHz in irectory Elec4614_labs_boost on the esktop an run the Space control esk program using Open experiment uner the file menu to run the corresponing experiment file. Observe the PWM switching pulses for a switching frequency of f s = 5 khz. Ajust the uty cycle. Note own the range over which can be ajuste. Set initially to minimum. Connect the switching signal from the SP to the gate of the GBT using a BNC cable. Connect this signal also to channel 4 of the CRO an use it to trigger the CRO at all times. Set L to 35 H, an to minimum initially. Connect the boost converter loa (R 50 ). The C supply,, to the converter is obtaine from rectifier-filter circuit. Switch AC power to the variac (auto-transformer) supplying the rectifier an ajust it to obtain a C supply of 50. The C supply must be maintaine at 50 throughout the rest of this experiment by ajustment of the variac for each setting of or loa current. 5. Observe the inuctor an the capacitor currents, an voltages across these on CRO channels 1, an 3 of the CRO using the isolate sensors or clip-on probes. Blue wire LC filter L o Re wire 3- phase 415 50Hz Supply ariac L (47-35 H) BNC it C 1000 F o o 5 Ohm Loa Rectifier GBT gate river SP PC CRO solate sensor boars Experiment C-C Boost Converter 4 F. Rahman/Feb, 011

Figure The peak-peak ripple on the output voltage can be observe by using AC coupling on the CRO. 5.3 isplay the switching waveform at the top of the CRO. Using a suitable time base, isplay i L, v L, i c, v o, i T, an i, three at a time, below the trace of the switching waveform. Ajust from 0.1 to 0.9 an ientify vales of for which continuous an iscontinuous conuction of inuctor current i L take place. Note that the input current of the boost converter an the output C voltage o can become isastrously high when approaches unity. You may fin it necessary to maintain below about 0.7 in orer to prevent such situations. 5.4 Tabulate the C values of o,, L an the inuctor current ripple Δ L versus. ary from 0.1 to 0.9 in steps of 0.. Maintain = 50 throughout, by ajusting the variac. Note own the value of for which conuction of the inuctor current is at the bounary between continuous an iscontinuous conuction. Print the waveforms of i L, i, i c an v o for this conition of operation only. Mark the value of in the printout. Reuce to zero by ajusting the variac. 5.5 Select L = 141 H. Set = 50 by ajusting the variac. Repeat 5.3 an 5.4. 5.6 Select L = 47 µh, Set = 50 by ajusting the variac. Repeat 5.3 an 5.4. 5.7 Run SP program Boost Converter - 10kHz an repeat 5.3 5.6 for L = 141 an 47 µh. 5.8 Run SP program Boost Converter - 0kHz an repeat 5.3 5.6 for L = 141 an 47 µh. 5.9 Run SP program Boost Converter Frequency Response Test. n orer to carry out a frequency response test on the inuctor current an output voltage responses, you will vary the uty cycle sinusoially at some frequency an measure the variations in L an o. As the frequency of variation of increases, the variation of L an o will eventually fail to follow it. This is given by a cut-off frequency at which the amplitue of L an o falls to 0.707 of its amplitue when the frequency of variation is well below the cut off frequency. Set the frequency of initially at 100Hz on the PC monitor. Set L = 35µH an f s = 0 khz. Note own the amplitue of the inuctor current an loa output voltage o. ncrease the frequency of an take a few reaings of amplitue of L an o vs frequency of. You are expecte to ata well beyon the cut-off frequency. 6.0 Report 6.1 Plot graphs of o versus from the results of sections 5. an 5.8 an iscuss with reference to theoretical preictions an experimental results. 6. escribe how switching frequency f s an the values of L affect the current ripple in the boost inuctor using your experimental results to verify theory. 6.3 escribe how o changes with when the converter operates with iscontinuous conuction using your experimental results to verify theory. 6.4 Plot the frequency response ata for inuctor current L an o versus frequency of foun in 5.9. Comment on these results. Experiment C-C Boost Converter 5 F. Rahman/Feb, 011

6.5 You may substantiate your comments by using the simulation results. Computer moel of the buck converter coul be built using PSM in the School computing lab or in room 130. Such moels will give you all waveforms you observe uring your experiment. Experiment C-C Boost Converter 6 F. Rahman/Feb, 011